HomeMy WebLinkAboutAPPROVED A4.0 PARTITIONS SCHEDULESHEET NUMBER
REVISIONS
This drawing is property of GMK, PALM BEACH,
FLORIDA. Any use of this drawing or the design
information hereon without written authorization of GMK
is strictly prohibited.
c 2021 GMK
PALM BEACH, FLORIDA
GMK
PLANNING - ZONING - DESIGN
G M KAGAN FAIA
205 WORTH AVENUE 201-111
PALM BEACH FL 33480
CELL: 203 988 1838
GMK@GMKPZD.COM
SOSNOWSKI RESIDENCE
Project Location:
3902 DUNESIDE DRIVE
FT PIERCE, FL 34949
CONSULTANTS
Project #: 2002
Architect: GERALD M. KAGAN
DATE : 08-25-2021
SHEET NAME:
SCALE: AS NOTED
PERMIT SET
INTERNATIONAL CONSULTING ENGINEERS &
DESIGN, LLC
4310 WEST BROWARD BLVD.
PLANTATION, FL 33317
T 561.707.6795 F 954.797.2847
CONTACT: JOE SPASOVSKI, P.E.
UNISONSTRUCTURALDESIGN
7522 WILES RD, SUITE B204
CORAL SPRINGS, FL 33067
PHONE: (954) 323-3746
MOBIL: (305) 298-0467
EMAIL:
UNISONSTRUCTURALDESIGN@GMAIL.COM
WEB:
UNISONSTRUCTURALDESIGN.COM
DATE : 10-06-2021
A4.0
PARTITIONS SCHEDULE
INTERIOR
PROVIDE DUROCK AND ALL WET
WALLS.
REFER TO STRUCTURAL DWG'S
FOR MASONRY WALL
REINFORCMENT.
EXTERIOR
REFER TO STRUCTURAL DWG'S
FOR MASONRY WALL
REINFORCMENT.
INTERIOR
3- 5/8" METAL STUDS (20 GA)
AT 16" O.C.
3- 5/8" BOTTOM CHANNEL (20GA.)
SECURED TO SLAB W/ 14" O
TAPCONS X 2 -1/4" LG AT 16" O.C.
TYP.
TOP OF CONCRETE SLAB
3 58" TOP RUNNER (20 GA.)
CEMENTITIOUS BACKER
UNIT DUROCK FINISH ON
WET WALLS
3- 5/8" METAL STUDS (20 GA)
AT 16" O.C.
3 -5/8" BOTTOM CHANNEL (20GA.)
SECURED TO SLAB W/ 14" O
TAPCONS X 2 -1/4" LG AT 16" O.C.
TYP.
TOP OF CONCRETE SLAB
3 5/8" TOP RUNNER (20 GA.)
5
8" GYP. BOARD
SOUND
INSULATION
(OPTIONAL)
5
8" GYP. BOARD
SCHEDULED FINISH FLOOR
5
8" GYP. CEILING
CEMENTITIOUS BACKER
UNIT DUROCK FINISH ON
WET WALLS
3
4" STUCCO FINISH (T0
MATCH EXISTING) ON 8"
CMU WALL, PAINTED.
BASE AS
SELECTED
BY OWNER
/ID
5
8" GYP. CEILING
5
8" GYP. BOARD ON 1x2 FURRING
STRIPS AT 16" O.C.
3
4" FOIL BACKED RIGID
INSULATION R4.1 MIN.
(REFER TO ENERGY
CALCULATIONS). TYPICAL
ON ALL EXTERIOR WALLS.
3
4" FOIL BACKED RIGID
INSULATION R4.1 MIN.
(REFER TO ENERGY
CALCULATIONS). TYPICAL
ON ALL EXTERIOR WALLS.
3
4" STUCCO FINISH (T0
MATCH EXISTING) ON 8"
CMU WALL, PAINTED.
EXTERIOR
3 - 5/8" METAL STUDS (20 GA)
AT 16" O.C.
3- 5/8" BOTTOM CHANNEL (20GA.)
SECURED TO SLAB W/ 1/4" O
TAPCONS X 2-1/4" LG AT 16" O.C.
TYP.
3 5/8" TOP RUNNER (20 GA.)
5
8" GYP. BOARD
CEMENTITIOUS BACKER
UNIT DUROCK FINISH ON
WET WALLS
6" METAL STUDS (20 GA)
AT 16" O.C.
3-5/8" BOTTOM CHANNEL (20GA.)
SECURED TO SLAB W/ 1/4" O
TAPCONS X 2 -1/4" LG AT 16" O.C.
TYP.
TOP OF CONCRETE SLAB
3 5/8" TOP RUNNER (20 GA.)
SCHEDULED FINISH FLOOR.
TOP OF CONCRETE SLAB
SCHEDULED
FINISH FLOOR.
5
8" GYP. CEILING 5
8" GYP. CEILING
MTL FRAMING
GWB CEILING
GLASS SHOWER ENCLOSURE AS
SCHEDULED
SLOPE EDGE SLIGHTLY TO
DRAIN WATER
GLAZING CHANNEL - SECURE TO
BLOCKING/SUBFLOOR
SEALANT TO MATCH
ADJACENT FINISH, TYP.
STONE/TILE AS SCHEDULED
BLOCKING AS REQUIRED
WATERPROOFING MEMEBRANE
THINSET MORTAR
5
8" CEMENT BOARD
3- 5/8" METAL STUDS
SLOPE TO DRAIN
V.I.F.2"
PARTITION SCHEDULE GENERAL NOTES
1.SEE PARTITION NOTES AND DRYWALL NOTES ON SHEET
A4.0
2.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
CROSS REFERENCING WALL CONSTRUCTION TYPES WITH
ALL WALL FINISHES. REFER TO INTERIOR ELEVATIONS AND
FINISH SCHEDULE FOR ADDITIONAL INFORMATION IF
APPLICABLE.
3.G.C. SHALL PROVIDE BLOCKING WHERE REQUIRED AT ALL
MOUNTING LOCATIONS (SHELF SUPPORTS, HANG RODS,
ETC.). COORDINATE WITH PLANS AND DETAILS. ALL WOOD
STUD BLOCKING TO BE FIRE RETARDANT TREATED.
4.G.C. IS RESPONSIBLE FOR COORDINATING WALL THICKNESS
WITH PLAN DIMENSIONS TO ACHIEVE ALL HOLD AND
MINIMUM CLEARANCES.
5. G.C. SHALL COORDINATE DOOR FRAMES SIZES AND
INSTALLATION REQUIREMENTS WITH WALL THICKNESS.
6. G.C. SHALL PROVIDE SOUND ATTENUATION
BLANKET/INSULATION AT LOCATIONS AS PER DETAILS.
7.G.C. SHALL PROVIDE PROPER STUD THICKNESS AT
PARTITIONS BEHIND PLUMBING FIXTURES, AND AT
PARTITIONS WITH SLIDING DOORS AS NOTED ON PLANS.
8. AT WALL RECEIVING CERAMIC TILE OR STONE FINISH
PROVIDE 5/8" CEMENT BOARD BACKER IN LIEU OF GWB AS
NOTES ON PLANS.
CONCRETE MUD-SET PAN SLOPED AT 1/4" PER FOOT TO
DRAIN. PROVIDE WATERPROOFING MATERIAL
40 MILLS SARLOY VINYL
WATERPROOFING
MEMBRANE, EXTEND VINYL
10" UP WALL
5/8" CEMENT BACKER BOARD W/
THIN SET CEMENT BED;
TO A HEIGHT OF NO LESS THAN
70" ABOVE THE COMPARTMENT
FLOOR AT THE DRAIN. AS PER
SECTION 1204.3 OF F.B.C.
4" RECESSED SHOWER
FRAMELESS, CATEGORY II SAFETY, GLASS SHOWER
SYSTEM. REFER TO MANUFACTURER FOR SPECIFICATIONS AND
INSTALLATION DETAILS. PROVIDE FINISH SAMPLES FOR
OWNER/ARHICTECT APPROVAL.
DRAINAGE
PER OWNER
SELECTION
DETAILS. REFER
TO PLUMBING
DWG'S.
8" CMU WALL OR PARTITION
WALL, REFER TO FLOOR
PLANS.
SHOWER FINISH
BY OWNER.
SLOPE TO DRAIN 1/4"/FT
4"EXTERIOR PARTITION STUCCO / DUROCKP2SCALE: 1 1-1/2" = 1'-0"3/4" FURRING STRIPS
INTERIOR PARTITION GYP. / GYP.
SCALE: 1 1-1/2" = 1'-0"P3 3 5/8" MTL. STUD
INTERIOR PARTITION GYP. / DUROCK
SCALE: 1 1-1/2" = 1'-0"
INTERIOR PARTITION GYP. / DUROCK
P4.1
SCALE: 1 1-1/2" = 1'-0"P4 3 5/8" MTL. STUD
6" MTL. STUD.
INTERIOR PARTITION DUROCK / DUROCK
SCALE: 1-1/2" = 1'-0"P5 INTERIOR PARTITION GYP.
SCALE: 1-1/2" = 1'-0"P6 3 5/8" MTL. STUD
EXTERIOR PARTITION STUCCO / GYP.P1 SCALE: 1 1-1/2" = 1'-0"3/4" FURRING STRIPS
TYPICAL SHOWER DETAIL1SCALE: 1 1/2" = 1'-0"TYPICAL SHOWER KNEE WALL
SCALE: 1-1/2" = 1'-0"P7 3 5/8" MTL. STUD
STONE/TILE AS SCHEDULED
SCHEDULED
FINISH FLOOR
6" MTL. STUD
INTERIOR
NOTE:
EXTERIOR WALLS TO RECEIVE
WATERPROOFING EQUAL TO
THEROSEAL" MASTERSEAL 583" OR
APPROVED EQUAL.
PROVIDE DUROCK AND ALL WET
WALLS.
REFER TO STRUCTURAL DWG'S
FOR MASONRY WALL
REINFORCMENT.
CEMENTITIOUS BACKER
UNIT DUROCK FINISH ON
WET WALLS
3
4" STUCCO FINISH (T0
MATCH EXISTING) ON 8"
CMU WALL, PAINTED.
3
4" FOIL BACKED RIGID
INSULATION R4.1 MIN.
(REFER TO ENERGY
CALCULATIONS). TYPICAL
ON ALL EXTERIOR WALLS.
EXTERIOR
EXTERIOR PARTITION STUCCO / DUROCKP8SCALE: 1 1-1/2" = 1'-0"3/4" FURRING STRIPS
3- 5/8" METAL STUDS
(20 GA)
AT 16" O.C.
INSULATION
BASE AS
SELECTED
BY OWNER
/ID
BASE AS
SELECTED
BY OWNER
/ID
BASE AS
SELECTED
BY OWNER
/ID
BASE AS
SELECTED
BY OWNER
/IDBASE AS
SELECTED
BY OWNER
/ID
BASE AS
SELECTED
BY OWNER
/ID
SOUND
INSULATION
(OPTIONAL)
R- VALUES CHART PER R103.2 FBC-ENERGY
CONSERVATION 7TH ED 2020
WALL TYPE AND INSULATION INSULATION R- VALUE
CONCRETE BLOCK - EXT INSUL, EXTERIOR R = 4.1
FRAME - WOOD, ADJACENT R = 11.0
CEILING TYPE AND INSULATION LEVEL INSULATION R- VALUE
ROOF DECK ( UNVENTED) (ICYNENE SPRAY INS.) R = 20.0
DUCT WORK INSULATION R- VALUE
R = 6.0
COOLING SYSTEMS
a. CENTRAL UNIT 46.5 KBTU/HR
10.000 EFFICIENCY
HEATING SYSTEMS
a. ELECTRIC HEAT PUMP 46.5 KBTU/HR
10.000 EFFICIENCY
HOT WATER SYSTEMS
a. ELECTRIC 46.5 KBTU/HR
10.000 EFFICIENCY
WINDOWS
U - FACTOR Sgl, U = 1.10
SHGC:SHGC = 0.32
2 10/05/21 BDC COMMENTS
2
NOTE: SEE ENERGY CALCULATIONS PROVIDED BY MEP ENGINEER
2
2
2
2
3 10/21/21 BDC COMMENTS
3