Loading...
HomeMy WebLinkAboutAPPROVED A4.0 PARTITIONS SCHEDULESHEET NUMBER REVISIONS This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 08-25-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET INTERNATIONAL CONSULTING ENGINEERS & DESIGN, LLC 4310 WEST BROWARD BLVD. PLANTATION, FL 33317 T 561.707.6795 F 954.797.2847 CONTACT: JOE SPASOVSKI, P.E. UNISONSTRUCTURALDESIGN 7522 WILES RD, SUITE B204 CORAL SPRINGS, FL 33067 PHONE: (954) 323-3746 MOBIL: (305) 298-0467 EMAIL: UNISONSTRUCTURALDESIGN@GMAIL.COM WEB: UNISONSTRUCTURALDESIGN.COM DATE : 10-06-2021 A4.0 PARTITIONS SCHEDULE INTERIOR PROVIDE DUROCK AND ALL WET WALLS. REFER TO STRUCTURAL DWG'S FOR MASONRY WALL REINFORCMENT. EXTERIOR REFER TO STRUCTURAL DWG'S FOR MASONRY WALL REINFORCMENT. INTERIOR 3- 5/8" METAL STUDS (20 GA) AT 16" O.C. 3- 5/8" BOTTOM CHANNEL (20GA.) SECURED TO SLAB W/ 14" O TAPCONS X 2 -1/4" LG AT 16" O.C. TYP. TOP OF CONCRETE SLAB 3 58" TOP RUNNER (20 GA.) CEMENTITIOUS BACKER UNIT DUROCK FINISH ON WET WALLS 3- 5/8" METAL STUDS (20 GA) AT 16" O.C. 3 -5/8" BOTTOM CHANNEL (20GA.) SECURED TO SLAB W/ 14" O TAPCONS X 2 -1/4" LG AT 16" O.C. TYP. TOP OF CONCRETE SLAB 3 5/8" TOP RUNNER (20 GA.) 5 8" GYP. BOARD SOUND INSULATION (OPTIONAL) 5 8" GYP. BOARD SCHEDULED FINISH FLOOR 5 8" GYP. CEILING CEMENTITIOUS BACKER UNIT DUROCK FINISH ON WET WALLS 3 4" STUCCO FINISH (T0 MATCH EXISTING) ON 8" CMU WALL, PAINTED. BASE AS SELECTED BY OWNER /ID 5 8" GYP. CEILING 5 8" GYP. BOARD ON 1x2 FURRING STRIPS AT 16" O.C. 3 4" FOIL BACKED RIGID INSULATION R4.1 MIN. (REFER TO ENERGY CALCULATIONS). TYPICAL ON ALL EXTERIOR WALLS. 3 4" FOIL BACKED RIGID INSULATION R4.1 MIN. (REFER TO ENERGY CALCULATIONS). TYPICAL ON ALL EXTERIOR WALLS. 3 4" STUCCO FINISH (T0 MATCH EXISTING) ON 8" CMU WALL, PAINTED. EXTERIOR 3 - 5/8" METAL STUDS (20 GA) AT 16" O.C. 3- 5/8" BOTTOM CHANNEL (20GA.) SECURED TO SLAB W/ 1/4" O TAPCONS X 2-1/4" LG AT 16" O.C. TYP. 3 5/8" TOP RUNNER (20 GA.) 5 8" GYP. BOARD CEMENTITIOUS BACKER UNIT DUROCK FINISH ON WET WALLS 6" METAL STUDS (20 GA) AT 16" O.C. 3-5/8" BOTTOM CHANNEL (20GA.) SECURED TO SLAB W/ 1/4" O TAPCONS X 2 -1/4" LG AT 16" O.C. TYP. TOP OF CONCRETE SLAB 3 5/8" TOP RUNNER (20 GA.) SCHEDULED FINISH FLOOR. TOP OF CONCRETE SLAB SCHEDULED FINISH FLOOR. 5 8" GYP. CEILING 5 8" GYP. CEILING MTL FRAMING GWB CEILING GLASS SHOWER ENCLOSURE AS SCHEDULED SLOPE EDGE SLIGHTLY TO DRAIN WATER GLAZING CHANNEL - SECURE TO BLOCKING/SUBFLOOR SEALANT TO MATCH ADJACENT FINISH, TYP. STONE/TILE AS SCHEDULED BLOCKING AS REQUIRED WATERPROOFING MEMEBRANE THINSET MORTAR 5 8" CEMENT BOARD 3- 5/8" METAL STUDS SLOPE TO DRAIN V.I.F.2" PARTITION SCHEDULE GENERAL NOTES 1.SEE PARTITION NOTES AND DRYWALL NOTES ON SHEET A4.0 2.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CROSS REFERENCING WALL CONSTRUCTION TYPES WITH ALL WALL FINISHES. REFER TO INTERIOR ELEVATIONS AND FINISH SCHEDULE FOR ADDITIONAL INFORMATION IF APPLICABLE. 3.G.C. SHALL PROVIDE BLOCKING WHERE REQUIRED AT ALL MOUNTING LOCATIONS (SHELF SUPPORTS, HANG RODS, ETC.). COORDINATE WITH PLANS AND DETAILS. ALL WOOD STUD BLOCKING TO BE FIRE RETARDANT TREATED. 4.G.C. IS RESPONSIBLE FOR COORDINATING WALL THICKNESS WITH PLAN DIMENSIONS TO ACHIEVE ALL HOLD AND MINIMUM CLEARANCES. 5. G.C. SHALL COORDINATE DOOR FRAMES SIZES AND INSTALLATION REQUIREMENTS WITH WALL THICKNESS. 6. G.C. SHALL PROVIDE SOUND ATTENUATION BLANKET/INSULATION AT LOCATIONS AS PER DETAILS. 7.G.C. SHALL PROVIDE PROPER STUD THICKNESS AT PARTITIONS BEHIND PLUMBING FIXTURES, AND AT PARTITIONS WITH SLIDING DOORS AS NOTED ON PLANS. 8. AT WALL RECEIVING CERAMIC TILE OR STONE FINISH PROVIDE 5/8" CEMENT BOARD BACKER IN LIEU OF GWB AS NOTES ON PLANS. CONCRETE MUD-SET PAN SLOPED AT 1/4" PER FOOT TO DRAIN. PROVIDE WATERPROOFING MATERIAL 40 MILLS SARLOY VINYL WATERPROOFING MEMBRANE, EXTEND VINYL 10" UP WALL 5/8" CEMENT BACKER BOARD W/ THIN SET CEMENT BED; TO A HEIGHT OF NO LESS THAN 70" ABOVE THE COMPARTMENT FLOOR AT THE DRAIN. AS PER SECTION 1204.3 OF F.B.C. 4" RECESSED SHOWER FRAMELESS, CATEGORY II SAFETY, GLASS SHOWER SYSTEM. REFER TO MANUFACTURER FOR SPECIFICATIONS AND INSTALLATION DETAILS. PROVIDE FINISH SAMPLES FOR OWNER/ARHICTECT APPROVAL. DRAINAGE PER OWNER SELECTION DETAILS. REFER TO PLUMBING DWG'S. 8" CMU WALL OR PARTITION WALL, REFER TO FLOOR PLANS. SHOWER FINISH BY OWNER. SLOPE TO DRAIN 1/4"/FT 4"EXTERIOR PARTITION STUCCO / DUROCKP2SCALE: 1 1-1/2" = 1'-0"3/4" FURRING STRIPS INTERIOR PARTITION GYP. / GYP. SCALE: 1 1-1/2" = 1'-0"P3 3 5/8" MTL. STUD INTERIOR PARTITION GYP. / DUROCK SCALE: 1 1-1/2" = 1'-0" INTERIOR PARTITION GYP. / DUROCK P4.1 SCALE: 1 1-1/2" = 1'-0"P4 3 5/8" MTL. STUD 6" MTL. STUD. INTERIOR PARTITION DUROCK / DUROCK SCALE: 1-1/2" = 1'-0"P5 INTERIOR PARTITION GYP. SCALE: 1-1/2" = 1'-0"P6 3 5/8" MTL. STUD EXTERIOR PARTITION STUCCO / GYP.P1 SCALE: 1 1-1/2" = 1'-0"3/4" FURRING STRIPS TYPICAL SHOWER DETAIL1SCALE: 1 1/2" = 1'-0"TYPICAL SHOWER KNEE WALL SCALE: 1-1/2" = 1'-0"P7 3 5/8" MTL. STUD STONE/TILE AS SCHEDULED SCHEDULED FINISH FLOOR 6" MTL. STUD INTERIOR NOTE: EXTERIOR WALLS TO RECEIVE WATERPROOFING EQUAL TO THEROSEAL" MASTERSEAL 583" OR APPROVED EQUAL. PROVIDE DUROCK AND ALL WET WALLS. REFER TO STRUCTURAL DWG'S FOR MASONRY WALL REINFORCMENT. CEMENTITIOUS BACKER UNIT DUROCK FINISH ON WET WALLS 3 4" STUCCO FINISH (T0 MATCH EXISTING) ON 8" CMU WALL, PAINTED. 3 4" FOIL BACKED RIGID INSULATION R4.1 MIN. (REFER TO ENERGY CALCULATIONS). TYPICAL ON ALL EXTERIOR WALLS. EXTERIOR EXTERIOR PARTITION STUCCO / DUROCKP8SCALE: 1 1-1/2" = 1'-0"3/4" FURRING STRIPS 3- 5/8" METAL STUDS (20 GA) AT 16" O.C. INSULATION BASE AS SELECTED BY OWNER /ID BASE AS SELECTED BY OWNER /ID BASE AS SELECTED BY OWNER /ID BASE AS SELECTED BY OWNER /IDBASE AS SELECTED BY OWNER /ID BASE AS SELECTED BY OWNER /ID SOUND INSULATION (OPTIONAL) R- VALUES CHART PER R103.2 FBC-ENERGY CONSERVATION 7TH ED 2020 WALL TYPE AND INSULATION INSULATION R- VALUE CONCRETE BLOCK - EXT INSUL, EXTERIOR R = 4.1 FRAME - WOOD, ADJACENT R = 11.0 CEILING TYPE AND INSULATION LEVEL INSULATION R- VALUE ROOF DECK ( UNVENTED) (ICYNENE SPRAY INS.) R = 20.0 DUCT WORK INSULATION R- VALUE R = 6.0 COOLING SYSTEMS a. CENTRAL UNIT 46.5 KBTU/HR 10.000 EFFICIENCY HEATING SYSTEMS a. ELECTRIC HEAT PUMP 46.5 KBTU/HR 10.000 EFFICIENCY HOT WATER SYSTEMS a. ELECTRIC 46.5 KBTU/HR 10.000 EFFICIENCY WINDOWS U - FACTOR Sgl, U = 1.10 SHGC:SHGC = 0.32 2 10/05/21 BDC COMMENTS 2 NOTE: SEE ENERGY CALCULATIONS PROVIDED BY MEP ENGINEER 2 2 2 2 3 10/21/21 BDC COMMENTS 3