HomeMy WebLinkAboutAPPROVED A5.0 WINDOW SCHEDULE (2)MATERIAL AREA
(S.F.)
MAS. OPNG.
W X H
V.I.F.
ALL HEIGHTS, DIMENSIONS AND LOCATIONS OF ALL NICHES, SHELVES AND CEILING DETAILS TO BE VERIFIED BY
CONTRACTOR/BUILDER.
NOTES
NOTES
A
B
WINDOW SCHEDULE
C
D
E
F
ALL BEAM HGTS ARE MEASURED FROM EL. +0'-0".
ALL CEILING HGTS ARE MEASURED FROM FINISH FLOOR OF EACH ROOM .(UNO)
ALL WINDOW HGTS ARE MEASURED FROM FINISH FLOOR OF EACH ROOM .
THIS RESIDENCE SHALL REQUIRE EXTERIOR IMPACT RESISTANT GLASS AND DOORS ACCORDING TO DADE COUNTY PRODUCT APPROVAL.
(UNLESS NOTED OTHERWISE)
TOP, BOTTOM AND SILL OF ALL NICHES AND ARCHES TO BE VERIFIED BY BUILDER.
TYPICAL NON-BEARING PARTITION - No. 25 Ga. CHANNEL SHAPED STUDS AT 24" O.C. WITH 1/2"
GYPSUM BOARD EACH SIDE. (16" O.C. @ WET AREAS) SEE DETAIL ON SHEET A5.2.
GLASS OR MIRRORS IMMEDIATELY SURROUNDING A BATHTUB OR SHOWER ENCLOSURE SHALL
BE SAFETY GLAZED WHERE LESS THAN 60" ABOVE FLOOR OF TUB OR SHOWER.
ALL GLASS SHOWER AND TUB ENCLOSURES TO BE TEMPERED PER FBC 2020
SEE STRUCTURAL DRAWINGS FOR DOOR & WINDOW PRESSURES. ALL EXTERIOR OPENINGS TO BE
IMPACT RESISTANT UNLESS NOTED OTHERWISE.
EMERGENCY EGRESS WINDOWS - AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE WITHOUT
THE USE OF TOOLS. EGRESS WINDOWS SHALL HAVE A MINIMUM NET OPENING OF 24" HIGH, 20" WIDE, AND
MIN. NET AREA OF 5.7 S.F. FOR 2nd FLOOR WINDOWS AND 5.0 S.F. FOR 1st FLOOR WINDOWS. THE SILL
HEIGHT SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR, LATCH AT 54" A.F.F. MAX.
NOTES
G
H
WINDOWS ON THE ZERO LOT LINE - WINDOWS ON THE PORTION OF THE HOME ON THE ZERO LOT LINE TO BE OBSCURE GLASS W/ WHITE INTERLAYER TO
ALLOW A MAX. OF 60% LIGHT TRANSMISSION- SEE MANUFACTURE'S SPECS. PROVIDED BY THE BUILDER.
ALUM.ALUM.2'-0" x 2'-0"4.0 FIXED GLASS24" X 24"
ALUM.ALUM.3'-0" X 6'-0"SINGLE HUNG18.037" X 72"
ALUM.ALUM.4'-0" x 6'-0"SINGLE HUNG24.049" X 72"
P.A. NO. -
I
J
K
L
M
O
WINDOW SIZE (WXH)MK WINDOW
TYPE FRAME
ALUM.ALUM.3'-0" X 6'-0"SINGLE HUNG18.037" X 72"
ALUM.ALUM.2'-0" x 2'-0"4.0 FIXED GLASS24" X 24"
ALUM.ALUM.2'-0" x 2'-0"4.0 FIXED GLASS24" X 24"
(1) MUNTIN ABV.
(1) MUNTIN ABV.
(1) MUNTIN ABV.
(1) MUNTIN ABV.
(1) MUNTIN ABV.
(1) MUNTIN ABV.
7'-6" x 6'-0"ALUM. 79" X 72"45.0 SINGLE HUNG ALUM.(3) PANELS
MUNTINS ABV.
ALUM.ALUM.2'-6" X 6'-0"SINGLE HUNG15.031" X 72"(1) MUNTIN ABV.
ALUM.ALUM.2'-6" X 6'-0"SINGLE HUNG15.031" X 72"(1) MUNTIN ABV.
7'-6" x 6'-0"ALUM. 79" X 72"45.0 SINGLE HUNG ALUM.
(3) PANELS
MUNTINS ABV.
ALUM.ALUM.3'-0" X 6'-0"SINGLE HUNG18.037" X 72"(1) MUNTIN ABV.
ALUM.ALUM.3'-0" X 6'-0"SINGLE HUNG18.037" X 72"(1) MUNTIN ABV.
ALUM.ALUM.2'-0" x 2'-0"4.0 FIXED GLASS24" X 24"(1) MUNTIN ABV.
ALUM.ALUM.4'-8" x 5'-6" V.I.F.25.66 FIXED GLASS57" X 24"(1) MUNTIN ABV.
VERIFY GLASS FIN.1 1
SHEET NUMBER
REVISIONS
This drawing is property of GMK, PALM BEACH,
FLORIDA. Any use of this drawing or the design
information hereon without written authorization of GMK
is strictly prohibited.
c 2021 GMK
PALM BEACH, FLORIDA
GMK
PLANNING - ZONING - DESIGN
G M KAGAN FAIA
205 WORTH AVENUE 201-111
PALM BEACH FL 33480
CELL: 203 988 1838
GMK@GMKPZD.COM
SOSNOWSKI RESIDENCE
Project Location:
3902 DUNESIDE DRIVE
FT PIERCE, FL 34949
CONSULTANTS
Project #: 2002
Architect: GERALD M. KAGAN
DATE : 08-25-2021
SHEET NAME:
SCALE: AS NOTED
PERMIT SET
INTERNATIONAL CONSULTING ENGINEERS &
DESIGN, LLC
4310 WEST BROWARD BLVD.
PLANTATION, FL 33317
T 561.707.6795 F 954.797.2847
CONTACT: JOE SPASOVSKI, P.E.
UNISONSTRUCTURALDESIGN
7522 WILES RD, SUITE B204
CORAL SPRINGS, FL 33067
PHONE: (954) 323-3746
MOBIL: (305) 298-0467
EMAIL:
UNISONSTRUCTURALDESIGN@GMAIL.COM
WEB:
UNISONSTRUCTURALDESIGN.COM
DATE : 10-06-2021
A5.0
WINDOW SCHEDULE / DETAILS
GLASS NOTE:
WINDOW SCREW SIZE AND LOCATIONS AS PER APPROVED SHOP DWG'S AND APPROVED NOA'S.
*ALL DIMENSIONS SHALL BE VERIFIED IN FIELD PRIOR TO COMMENCE WORK.
**WINDOW AND DOOR INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS SET FORTH IN THE APPROVED NOA'S.
OTHER WINDOW NOTES:
1.ALL WINDOWS AS MANUFACTURED BY "FLEETWOOD" OR OWNER APPROVED EQUAL. ALL WINDOWS SHALL BE ALUMINUM FRAME WITH CLEAR GLASS MIAMI DADE COUNTY APPROVED OR EQUAL. WINDOW PERMIT IS
REQUIRED PRIOR TO ORDERING WINDOWS.
2.CONTRACTOR TO VERIFY ALL DIMENSIONS ON SITE PRIOR TO ORDERING WINDOWS. ALL WINDOW MASONRY OPENINGS SHALL BE COORDINATED BY WINDOW COMPANY AND CONTRACTOR PRIOR TO PLACING WINDOW
ORDER AND FRAMING OPENINGS.
3. WINDOW COMPANY SHALL PRODUCE SHOP DRAWINGS FOR ARCHITECTS REVIEW PRIOR TO THEIR FABRICATION.
4.EXTERIOR WINDOWS TO BE FLASHED WITH LIQUID WATERPROOFING BY KEMPER, TREMCO OR APPROVED EQUAL AROUND PERIMETER OF ALL WINDOW BUCKS. MEMBRANE TO EXTEND 12" MIN. FROM HEADER, JAMBS AND
SILL ON BOTH SIDES.
5. BUCKS:
A) SHALL BE PRESSURE TREATED.
B) FASTEN BUCK TO STRUCTURE PER STRUCTURAL DWG'S.
C) JOINT BETWEEN STRUCTURE AND WOOD BUCK SHALL BE CAULKED CONTINUOUSLY (AT HEAD AND JAMB).
D) JAMB BUCKS SHALL BE KEPT 12" OFF SILL BUCK IN ORDER TO AVOID WICKING OF MOISTURE FROM SILL BUCKS TO JAMB BUCKS.
6.PROVIDE A WATER-STOP AT THE EXTERIOR FACE OF ALL CONCRETE WINDOW SILLS, MIN. 34" TO 2 18" (ACTUAL) OR AS SHOWN ON THE DWG'S.
7.SILL FLASHING AT WINDOWS AND DOORS: FULL DEPTH COPPER PAN W/ MULTI-STEPS, BREAKS IN THE PAN, SOLDERED SEAMS AND EXPANDED COPPER LATH. EXTEND MIN. 4" UP AND BULL IN. THE PANS ARE NOT SIMPLE "L",
FLASHING WITH THE CORNERS TURNED.
8. PROVIDE LEAD COPPER COATING.
9. PROVIDE PEEL AND STICK FLASHING ABOVE AND BELOW COPPER FLASHING.
10. PROVIDE 14" BACKER ROD AND SEALANT BETWEEN BUCK AND DOOR OR WINDOW FRAME TO SEAL PASSAGE OF WATER FROM EXTERIOR INTO INTERIOR OF RESIDENCE. IF BRICKMOLD IS PRE-APPLIED, THEN THE BACKER
ROD AND SEALANT SHALL BE BETWEEN THE BRICKMOLD AND THE STUCCO OR STONE RETURN.
11. WINDOWS SHALL HAVE COUNTY APPROVED IMPACT GLASS. CONTRACTOR TO SUBMIT PRODUCT APPROVALS.
12. ALL IMPACT RESISTANT GLASS TO BE CLEAR, LOW-E INSULATED GLASS. PROVIDE FINISH SAMPLES FOR OWNER/ARCHITECT APPROVAL.
13. PROVIDE SAFETY TYPE GLAZING CAT II WITHIN 60" OF BATHTUB/ SHOWER.
14. ALL EGRESS WINDOWS TO COMPLY WITH NFPA 101 OF F.B.C.; EGRESS WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS, KEYS OR SPECIAL EFFORTS PROVIDING A CLEAR OPENING OF NOT
LESS THAN 20" IN WIDTH AND 24" IN HEIGHT. BOTTOM OF OPENING SHALL BE NO MORE THAN 44" ABOVE FINISH FLOOR LEVEL AS PER FLORIDA BUILDING CODE RESIDENTIAL EDITION 2017.
15. THE MODE OF OPERATION MUST NOT REQUIRE THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT TO MAKE AVAILABLE THE REQUIRED CLEAR OPENING, AND NO PART OF THE OPERATION MECHANISM SHALL BE
PLACED HIGHER THAN 54" ABOVE FINISHED FLOOR.
VULKEN WATERPROOFING
350/350S OR APPROVED
EQUAL ON ALL WINDOWS
AND DOORS. (TYP.)
ALUM. SINGLE HUNG WINDOW
WITH IMPACT RATED GLASS
CONTRACTOR TO PROVIDE
SHOP DWG'S AND
APPROVED NOA FOR
REVIEW AND APPROVAL.
CORNER BEAD & BACK
BEDDING.
"J" BEAD
1X WOOD BUCK
5
8" GYPBOARD ON 1x2
FURRING STRIPS AT 16" O.C.
4"
4"
3
4" SMOOTH STUCCO
FINISH, 3 COAT.
STUCCO CORNER
BEAD & BACK
BEDDING, TYP.
P.T. WOOD BUCK
BED IN SEALANT.
STRUCTURAL
SEALANT BEAD AND
BACKER ROD PER
MANUFACTURERS
SPECIFICATIONS.
STUCCO CORNER
BEAD & BACK
BEDDING, TYP.
"NEOLITH CALACATTA"
WINDOW SILL OR
APPROVED EQUAL BY
OWNER.
VULKEN
WATERPROOFING
350/350S OR APPROVED
EQUAL ON ALL
WINDOWS AND DOORS.
(TYP.)
ALUM. WINDOW WITH IMPACT RATED
GLASS . CONTRACTOR TO PROVIDE
SHOP DWG'S AND APPROVED NOA
FOR REVIEW AND APPROVAL.
P.T. WOOD BUCK
BED IN SEALANT.
STRUCTURAL
SEALANT BEAD AND
BACKER ROD PER
MANUFACTURERS
SPECIFICATIONS.
CORNER BEAD & BACK
BEDDING.
5
8" GYPBOARD N 3/4"
FURRING STRIPS AT 16" O.C.
"NEOLITH CALACATTA"
WINDOW SILL OR
APPROVED EQUAL BY
OWNER.
VULKEN
WATERPROOFING
350/350S OR
APPROVED EQUAL ON
ALL WINDOWS AND
DOORS. (TYP.)
ALUM. SINGLE HUNG
WINDOW WITH IMPACT RATED GLASS .
CONTRACTOR TO PROVIDE SHOP
DWG'S AND APPROVED NOA FOR
REVIEW AND APPROVAL.
"NEOLITH CALACATTA"
WINDOW SILL OR
APPROVED EQUAL BY
OWNER.
CORNER BEAD & BACK
BEDDING.
5
8" GYPBOARD ON 1x2
FURRING STRIPS AT 16" O.C.
P.T. WOOD BUCK
BED IN SEALANT.
STRUCTURAL
SEALANT BEAD AND
BACKER ROD PER
MANUFACTURERS
SPECIFICATIONS.
NOTE:
ALL PT WOOD BUCKING TO BE SET IN FULL
SEALANT. SECURE ALL WINDOW/DOOR
BUCKS IN ACCORDANCE WITH N.O.A FOR
WINDOW/DOOR ASSEMBLY
4"4"
VULKEN WATERPROOFING
350/350S OR APPROVED
EQUAL ON ALL WINDOWS
AND DOORS. (TYP.)
ALUM. SINGLE HUNG
WINDOW WITH
IMPACT RATED GLASS .
CONTRACTOR TO PROVIDE
SHOP DWG'S AND
APPROVED NOA FOR
REVIEW AND APPROVAL.
CORNER BEAD & BACK
BEDDING.
3
4" SMOOTH STUCCO
FINISH, 3 COAT.
STUCCO CORNER
BEAD & BACK
BEDDING, TYP.
P.T. WOOD BUCK
BED IN SEALANT.
STRUCTURAL
SEALANT BEAD AND
BACKER ROD PER
MANUFACTURERS
SPECIFICATIONS.
"J" BEAD
STUCCO CORNER
BEAD & BACK
BEDDING, TYP.
1X WOOD BUCK
5
8" GYPBOARD ON 1x2
FURRING STRIPS AT 16" O.C.
"NEOLITH CALACATTA"
WINDOW SILL OR
APPROVED EQUAL BY
OWNER.
WINDOW SCHEDULE / DETAILS1SCALE: N.T.S
TYPICAL FIXED WINDOW HEAD/SILL DETAIL3SCALE: N.T.S
TYPICAL FIXED WINDOW JAMB DETAIL4SCALE: N.T.S
TYPICAL SINGLE HUNG WINDOW HEAD/SILL DTL1SCALE: N.T.S
TYPICAL SINGLE HUNG WINDOW JAMB DETAIL2SCALE: N.T.S
1 08/25/21 CLIENT CHANGES
2 10/05/21 BDC COMMENTS
2
3 10/21/21 BDC COMMENTS
3