Loading...
HomeMy WebLinkAboutAPPROVED A5.0 WINDOW SCHEDULE (2)MATERIAL AREA (S.F.) MAS. OPNG. W X H V.I.F. ALL HEIGHTS, DIMENSIONS AND LOCATIONS OF ALL NICHES, SHELVES AND CEILING DETAILS TO BE VERIFIED BY CONTRACTOR/BUILDER. NOTES NOTES A B WINDOW SCHEDULE C D E F ALL BEAM HGTS ARE MEASURED FROM EL. +0'-0". ALL CEILING HGTS ARE MEASURED FROM FINISH FLOOR OF EACH ROOM .(UNO) ALL WINDOW HGTS ARE MEASURED FROM FINISH FLOOR OF EACH ROOM . THIS RESIDENCE SHALL REQUIRE EXTERIOR IMPACT RESISTANT GLASS AND DOORS ACCORDING TO DADE COUNTY PRODUCT APPROVAL. (UNLESS NOTED OTHERWISE) TOP, BOTTOM AND SILL OF ALL NICHES AND ARCHES TO BE VERIFIED BY BUILDER. TYPICAL NON-BEARING PARTITION - No. 25 Ga. CHANNEL SHAPED STUDS AT 24" O.C. WITH 1/2" GYPSUM BOARD EACH SIDE. (16" O.C. @ WET AREAS) SEE DETAIL ON SHEET A5.2. GLASS OR MIRRORS IMMEDIATELY SURROUNDING A BATHTUB OR SHOWER ENCLOSURE SHALL BE SAFETY GLAZED WHERE LESS THAN 60" ABOVE FLOOR OF TUB OR SHOWER. ALL GLASS SHOWER AND TUB ENCLOSURES TO BE TEMPERED PER FBC 2020 SEE STRUCTURAL DRAWINGS FOR DOOR & WINDOW PRESSURES. ALL EXTERIOR OPENINGS TO BE IMPACT RESISTANT UNLESS NOTED OTHERWISE. EMERGENCY EGRESS WINDOWS - AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS. EGRESS WINDOWS SHALL HAVE A MINIMUM NET OPENING OF 24" HIGH, 20" WIDE, AND MIN. NET AREA OF 5.7 S.F. FOR 2nd FLOOR WINDOWS AND 5.0 S.F. FOR 1st FLOOR WINDOWS. THE SILL HEIGHT SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR, LATCH AT 54" A.F.F. MAX. NOTES G H WINDOWS ON THE ZERO LOT LINE - WINDOWS ON THE PORTION OF THE HOME ON THE ZERO LOT LINE TO BE OBSCURE GLASS W/ WHITE INTERLAYER TO ALLOW A MAX. OF 60% LIGHT TRANSMISSION- SEE MANUFACTURE'S SPECS. PROVIDED BY THE BUILDER. ALUM.ALUM.2'-0" x 2'-0"4.0 FIXED GLASS24" X 24" ALUM.ALUM.3'-0" X 6'-0"SINGLE HUNG18.037" X 72" ALUM.ALUM.4'-0" x 6'-0"SINGLE HUNG24.049" X 72" P.A. NO. - I J K L M O WINDOW SIZE (WXH)MK WINDOW TYPE FRAME ALUM.ALUM.3'-0" X 6'-0"SINGLE HUNG18.037" X 72" ALUM.ALUM.2'-0" x 2'-0"4.0 FIXED GLASS24" X 24" ALUM.ALUM.2'-0" x 2'-0"4.0 FIXED GLASS24" X 24" (1) MUNTIN ABV. (1) MUNTIN ABV. (1) MUNTIN ABV. (1) MUNTIN ABV. (1) MUNTIN ABV. (1) MUNTIN ABV. 7'-6" x 6'-0"ALUM. 79" X 72"45.0 SINGLE HUNG ALUM.(3) PANELS MUNTINS ABV. ALUM.ALUM.2'-6" X 6'-0"SINGLE HUNG15.031" X 72"(1) MUNTIN ABV. ALUM.ALUM.2'-6" X 6'-0"SINGLE HUNG15.031" X 72"(1) MUNTIN ABV. 7'-6" x 6'-0"ALUM. 79" X 72"45.0 SINGLE HUNG ALUM. (3) PANELS MUNTINS ABV. ALUM.ALUM.3'-0" X 6'-0"SINGLE HUNG18.037" X 72"(1) MUNTIN ABV. ALUM.ALUM.3'-0" X 6'-0"SINGLE HUNG18.037" X 72"(1) MUNTIN ABV. ALUM.ALUM.2'-0" x 2'-0"4.0 FIXED GLASS24" X 24"(1) MUNTIN ABV. ALUM.ALUM.4'-8" x 5'-6" V.I.F.25.66 FIXED GLASS57" X 24"(1) MUNTIN ABV. VERIFY GLASS FIN.1 1 SHEET NUMBER REVISIONS This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 08-25-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET INTERNATIONAL CONSULTING ENGINEERS & DESIGN, LLC 4310 WEST BROWARD BLVD. PLANTATION, FL 33317 T 561.707.6795 F 954.797.2847 CONTACT: JOE SPASOVSKI, P.E. UNISONSTRUCTURALDESIGN 7522 WILES RD, SUITE B204 CORAL SPRINGS, FL 33067 PHONE: (954) 323-3746 MOBIL: (305) 298-0467 EMAIL: UNISONSTRUCTURALDESIGN@GMAIL.COM WEB: UNISONSTRUCTURALDESIGN.COM DATE : 10-06-2021 A5.0 WINDOW SCHEDULE / DETAILS GLASS NOTE: WINDOW SCREW SIZE AND LOCATIONS AS PER APPROVED SHOP DWG'S AND APPROVED NOA'S. *ALL DIMENSIONS SHALL BE VERIFIED IN FIELD PRIOR TO COMMENCE WORK. **WINDOW AND DOOR INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS SET FORTH IN THE APPROVED NOA'S. OTHER WINDOW NOTES: 1.ALL WINDOWS AS MANUFACTURED BY "FLEETWOOD" OR OWNER APPROVED EQUAL. ALL WINDOWS SHALL BE ALUMINUM FRAME WITH CLEAR GLASS MIAMI DADE COUNTY APPROVED OR EQUAL. WINDOW PERMIT IS REQUIRED PRIOR TO ORDERING WINDOWS. 2.CONTRACTOR TO VERIFY ALL DIMENSIONS ON SITE PRIOR TO ORDERING WINDOWS. ALL WINDOW MASONRY OPENINGS SHALL BE COORDINATED BY WINDOW COMPANY AND CONTRACTOR PRIOR TO PLACING WINDOW ORDER AND FRAMING OPENINGS. 3. WINDOW COMPANY SHALL PRODUCE SHOP DRAWINGS FOR ARCHITECTS REVIEW PRIOR TO THEIR FABRICATION. 4.EXTERIOR WINDOWS TO BE FLASHED WITH LIQUID WATERPROOFING BY KEMPER, TREMCO OR APPROVED EQUAL AROUND PERIMETER OF ALL WINDOW BUCKS. MEMBRANE TO EXTEND 12" MIN. FROM HEADER, JAMBS AND SILL ON BOTH SIDES. 5. BUCKS: A) SHALL BE PRESSURE TREATED. B) FASTEN BUCK TO STRUCTURE PER STRUCTURAL DWG'S. C) JOINT BETWEEN STRUCTURE AND WOOD BUCK SHALL BE CAULKED CONTINUOUSLY (AT HEAD AND JAMB). D) JAMB BUCKS SHALL BE KEPT 12" OFF SILL BUCK IN ORDER TO AVOID WICKING OF MOISTURE FROM SILL BUCKS TO JAMB BUCKS. 6.PROVIDE A WATER-STOP AT THE EXTERIOR FACE OF ALL CONCRETE WINDOW SILLS, MIN. 34" TO 2 18" (ACTUAL) OR AS SHOWN ON THE DWG'S. 7.SILL FLASHING AT WINDOWS AND DOORS: FULL DEPTH COPPER PAN W/ MULTI-STEPS, BREAKS IN THE PAN, SOLDERED SEAMS AND EXPANDED COPPER LATH. EXTEND MIN. 4" UP AND BULL IN. THE PANS ARE NOT SIMPLE "L", FLASHING WITH THE CORNERS TURNED. 8. PROVIDE LEAD COPPER COATING. 9. PROVIDE PEEL AND STICK FLASHING ABOVE AND BELOW COPPER FLASHING. 10. PROVIDE 14" BACKER ROD AND SEALANT BETWEEN BUCK AND DOOR OR WINDOW FRAME TO SEAL PASSAGE OF WATER FROM EXTERIOR INTO INTERIOR OF RESIDENCE. IF BRICKMOLD IS PRE-APPLIED, THEN THE BACKER ROD AND SEALANT SHALL BE BETWEEN THE BRICKMOLD AND THE STUCCO OR STONE RETURN. 11. WINDOWS SHALL HAVE COUNTY APPROVED IMPACT GLASS. CONTRACTOR TO SUBMIT PRODUCT APPROVALS. 12. ALL IMPACT RESISTANT GLASS TO BE CLEAR, LOW-E INSULATED GLASS. PROVIDE FINISH SAMPLES FOR OWNER/ARCHITECT APPROVAL. 13. PROVIDE SAFETY TYPE GLAZING CAT II WITHIN 60" OF BATHTUB/ SHOWER. 14. ALL EGRESS WINDOWS TO COMPLY WITH NFPA 101 OF F.B.C.; EGRESS WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS, KEYS OR SPECIAL EFFORTS PROVIDING A CLEAR OPENING OF NOT LESS THAN 20" IN WIDTH AND 24" IN HEIGHT. BOTTOM OF OPENING SHALL BE NO MORE THAN 44" ABOVE FINISH FLOOR LEVEL AS PER FLORIDA BUILDING CODE RESIDENTIAL EDITION 2017. 15. THE MODE OF OPERATION MUST NOT REQUIRE THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT TO MAKE AVAILABLE THE REQUIRED CLEAR OPENING, AND NO PART OF THE OPERATION MECHANISM SHALL BE PLACED HIGHER THAN 54" ABOVE FINISHED FLOOR. VULKEN WATERPROOFING 350/350S OR APPROVED EQUAL ON ALL WINDOWS AND DOORS. (TYP.) ALUM. SINGLE HUNG WINDOW WITH IMPACT RATED GLASS CONTRACTOR TO PROVIDE SHOP DWG'S AND APPROVED NOA FOR REVIEW AND APPROVAL. CORNER BEAD & BACK BEDDING. "J" BEAD 1X WOOD BUCK 5 8" GYPBOARD ON 1x2 FURRING STRIPS AT 16" O.C. 4" 4" 3 4" SMOOTH STUCCO FINISH, 3 COAT. STUCCO CORNER BEAD & BACK BEDDING, TYP. P.T. WOOD BUCK BED IN SEALANT. STRUCTURAL SEALANT BEAD AND BACKER ROD PER MANUFACTURERS SPECIFICATIONS. STUCCO CORNER BEAD & BACK BEDDING, TYP. "NEOLITH CALACATTA" WINDOW SILL OR APPROVED EQUAL BY OWNER. VULKEN WATERPROOFING 350/350S OR APPROVED EQUAL ON ALL WINDOWS AND DOORS. (TYP.) ALUM. WINDOW WITH IMPACT RATED GLASS . CONTRACTOR TO PROVIDE SHOP DWG'S AND APPROVED NOA FOR REVIEW AND APPROVAL. P.T. WOOD BUCK BED IN SEALANT. STRUCTURAL SEALANT BEAD AND BACKER ROD PER MANUFACTURERS SPECIFICATIONS. CORNER BEAD & BACK BEDDING. 5 8" GYPBOARD N 3/4" FURRING STRIPS AT 16" O.C. "NEOLITH CALACATTA" WINDOW SILL OR APPROVED EQUAL BY OWNER. VULKEN WATERPROOFING 350/350S OR APPROVED EQUAL ON ALL WINDOWS AND DOORS. (TYP.) ALUM. SINGLE HUNG WINDOW WITH IMPACT RATED GLASS . CONTRACTOR TO PROVIDE SHOP DWG'S AND APPROVED NOA FOR REVIEW AND APPROVAL. "NEOLITH CALACATTA" WINDOW SILL OR APPROVED EQUAL BY OWNER. CORNER BEAD & BACK BEDDING. 5 8" GYPBOARD ON 1x2 FURRING STRIPS AT 16" O.C. P.T. WOOD BUCK BED IN SEALANT. STRUCTURAL SEALANT BEAD AND BACKER ROD PER MANUFACTURERS SPECIFICATIONS. NOTE: ALL PT WOOD BUCKING TO BE SET IN FULL SEALANT. SECURE ALL WINDOW/DOOR BUCKS IN ACCORDANCE WITH N.O.A FOR WINDOW/DOOR ASSEMBLY 4"4" VULKEN WATERPROOFING 350/350S OR APPROVED EQUAL ON ALL WINDOWS AND DOORS. (TYP.) ALUM. SINGLE HUNG WINDOW WITH IMPACT RATED GLASS . CONTRACTOR TO PROVIDE SHOP DWG'S AND APPROVED NOA FOR REVIEW AND APPROVAL. CORNER BEAD & BACK BEDDING. 3 4" SMOOTH STUCCO FINISH, 3 COAT. STUCCO CORNER BEAD & BACK BEDDING, TYP. P.T. WOOD BUCK BED IN SEALANT. STRUCTURAL SEALANT BEAD AND BACKER ROD PER MANUFACTURERS SPECIFICATIONS. "J" BEAD STUCCO CORNER BEAD & BACK BEDDING, TYP. 1X WOOD BUCK 5 8" GYPBOARD ON 1x2 FURRING STRIPS AT 16" O.C. "NEOLITH CALACATTA" WINDOW SILL OR APPROVED EQUAL BY OWNER. WINDOW SCHEDULE / DETAILS1SCALE: N.T.S TYPICAL FIXED WINDOW HEAD/SILL DETAIL3SCALE: N.T.S TYPICAL FIXED WINDOW JAMB DETAIL4SCALE: N.T.S TYPICAL SINGLE HUNG WINDOW HEAD/SILL DTL1SCALE: N.T.S TYPICAL SINGLE HUNG WINDOW JAMB DETAIL2SCALE: N.T.S 1 08/25/21 CLIENT CHANGES 2 10/05/21 BDC COMMENTS 2 3 10/21/21 BDC COMMENTS 3