Loading...
HomeMy WebLinkAboutAPPROVED A5.1 EXTERIOR & INTERIOR DOOR SCHEDULE (2)MK MATERIAL MAS. OPNG. W X D AREA (S.F.) DOOR TYPEDOOR SIZE NOTES ALL GLASS IN EXTERIOR DOORS TO BE IMPACT RESISTANT AND TEMPERED NOTE: SEE EXTERIOR ELEVATIONS ON STRUCTURAL PLANS FOR DOOR AND WINDOW DESIGN PRESSURES. APPROVED PRODUCT APPROVALS FOR ALL EXTERIOR DOORS AND WINDOWS TO BE SUBMITTED WITH PERMIT PLANS. 3080 W/ 2 LITES ALUM 44.80 EXTERIOR DOOR SCHEDULE D-2 D-3 FRAME LOC . EXTR NOTES D-4 D-5 18080 OVERHEADALUM144.0218" X 96"EXTRWD 3080 68" X 96" 24.0ALUM SWING ALUM EXTR 6080 SLIDINGALUM/GL 74" X 96"48.0 EXTRALUM 12080 146" X 96"96.00 ALUM EXTR P.A. NO. - D-1 SEE ELEVATION 40" X 96" SWING / FRENCH DOOR ALUM/GL (2) PANELS (3) PANELS ALUM SEE ELEVATION MATERIAL DOOR TYPE FRAME LOC .DOOR SIZE 2880 WD INT.WD SOLID CORE INTERIOR DOOR SCHEDULE 1 NOTES 2 3 4 SWING SELF-CLOSING TO BE MIN. 1-3/8" THICK SOLID CORE OR 20 MIN. FIRE RATING NOTES ALL INTERIOR SWING DOORS TO BE HOLLOW CORE WITH RAISED PANELS U.N.O. ALL GLASS IN INTERIOR DOORS AND ALL SLIDING GLASS DOORS TO BE TEMPERED. ALL GLASS SHOWER AND TUB ENCLOSURES TO HAVE SAFETY GLASS PER FBCR. ALL BATHROOMS TO HAVE MARBLE SADDLE TO COORDINATE W/ ADJACENT SELECTION. ALL INT. SWING DRS. HAVE LEVER HANDLES, SATIN NICKEL COLOR- 'SCHLAGE' TORINO OR APPROVED EQUAL. 5 6 7 8 9 2680 WD INT. 3080 WD INTWD 2680 WD INTWD SWING 2880 WD INTWD SWING 2680 WD INTWD SWING WD INTWD BI-PASS 10 2480 WD INTWDSWING SWING W/ CLOSER 11 2880 SWING SWING WD INTWD2880 SWING 3680 WD INTWDBARN PROVIDE SHOP DRAWINGS TO ARCHITECT FOR REVIEW 2480 WD INTWDSWING WD SLIDING SHEET NUMBER REVISIONS This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 08-25-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET INTERNATIONAL CONSULTING ENGINEERS & DESIGN, LLC 4310 WEST BROWARD BLVD. PLANTATION, FL 33317 T 561.707.6795 F 954.797.2847 CONTACT: JOE SPASOVSKI, P.E. UNISONSTRUCTURALDESIGN 7522 WILES RD, SUITE B204 CORAL SPRINGS, FL 33067 PHONE: (954) 323-3746 MOBIL: (305) 298-0467 EMAIL: UNISONSTRUCTURALDESIGN@GMAIL.COM WEB: UNISONSTRUCTURALDESIGN.COM DATE : 10-06-2021 A5.1 EXTERIOR AND INTERIOR DOOR SCHEDULE / DETAILS INTERIOR DOOR JAMB DETAIL1SCALE: 3" = 1'-0" INTERIOR DOOR HEAD DETAIL2SCALE: 3" = 1'-0" DOOR NOTES: 1.ALL DOORS PER OWNER SELECTION. ALL DOORS SHALL BE ALUMINUM FRAME WITH CLEAR GLASS MIAMI DADE COUNTY APPROVED OR EQUAL. DOOR PERMIT IS REQUIRED PRIOR TO ORDERING DOORS. SEE EXTERIOR ELEVATIONS 2.ALL EXTERIOR DOOR MASONRY OPENINGS SHALL BE COORDINATED BY DOOR COMPANY AND CONTRACTOR PRIOR TO PLACING EXTERIOR DOOR ORDER AND FRAMING OPENINGS. 4.EXTERIOR WINDOWS TO BE FLASHED WITH LIQUID WATERPROOFING BY KEMPER, TREMCO OR APPROVED EQUAL AROUND PERIMETER OF ALL WINDOW BUCKS. MEMBRANE TO EXTEND 12" MIN. FROM HEADER, JAMBS AND SILL ON BOTH SIDES. 5. BUCKS: A)SHALL BE PRESSURE TREATED. B)FASTEN BUCK TO STRUCTURE PER STRUCTURAL DWG'S. C)JOINT BETWEEN STRUCTURE AND WOOD BUCK SHALL BE CAULKED CONTINUOUSLY (AT HEAD AND JAMB). D)JAMB BUCKS SHALL BE KEPT 12" OFF SILL BUCK IN ORDER TO AVOID WICKING OF MOISTURE FROM SILL BUCKS TO JAMB BUCKS. 6.SILL FLASHING AT WINDOWS AND DOORS: FULL DEPTH COPPER PAN W/ MULTI-STEPS, BREAKS IN THE PAN, SOLDERED SEAMS AND EXPANDED COPPER LATH. EXTEND MIN. 4" UP AND BULL IN. THE PANS ARE NOT SIMPLE "L", FLASHING WITH THE CORNERS TURNED. 8. PROVIDE PEEL AND STICK FLASHING ABOVE AND BELOW COPPER FLASHING. 9. PROVIDE 1/4" BACKER ROD AND SEALANT BETWEEN BUCK AND DOOR OR WINDOW FRAME TO SEAL PASSAGE OF WATER FROM EXTERIOR INTO INTERIOR OF RESIDENCE. IF BRICKMOLD IS PRE-APPLIED, THEN THE BACKER ROD AND SEALANT SHALL BE BETWEEN THE BRICKMOLD AND THE STUCCO OR STONE RETURN. DOOR COMPANY SHALL PRODUCE SHOP DRAWINGS FOR ARCHITECTS REVIEW PRIOR TO THEIR FABRICATION. 10. ALL EXTERIOR GLASS DOORS SHALL HAVE CATEGORY II SAFTEY-PLUS IMPACT GLASS. 11. ALL IMPACT RESISTANT GLASS TO BE CLEAR, LOW-E INSULATED GLASS. PROVIDE FINISH SAMPLES FOR OWNER/ARCHITECT APPROVAL. 12. INTERIOR DOORS TO BE PAINT GRADE WOOD UNLESS OTHERWISE NOTED. CONTRACTOR TO VERIFY ALL DOOR WIDTHS, WALL THICKNESS AND SWINGS IN FIELD PRIOR TO ORDERING. 13. ALL INTERIOR DOOR FRAMES TO BE PAINT GRADE WOOD WITHOUT FINGER JOINTS. VERIFY ALL FRAME WIDTH WITH WALL THICKNESS. 14. ALL DOOR HARDWARE HEIGHT TO BE 36" A.F.F. AND TO BE SELECTED BY OWNER/ARCHITECT, GENERAL CONTRACTOR TO COORDINATE WITH OWNER. GLASS NOTE: DOOR SCREW SIZE AND LOCATIONS AS PER APPROVED SHOP DWG'S AND APPROVED NOA'S. *ALL DIMENSIONS SHALL BE VERIFIED IN FIELD PRIOR TO COMMENCE WORK. **WINDOW AND DOOR INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS SET FORTH IN THE APPROVED NOA'S. WOOD DOOR AS SCHEDULED DOOR HINGE AS SCHEDULED WOOD FRAME AS SCHEDULED HD WD BLOCKING RM01 14" REVEAL MOLDING, "Z" FRY REGLET DRMZ-25-25 SEE PLAN FOR PARTITION TYPE 14"1"1"14" ALIGN 14"ALIGN 14"112"14"112" SEE PLAN FOR PARTITION TYPE MTL SUTD BOX BEAM AND FRAMING HD WOOD BLOCKING RM01 14" REVEL MOLDING, "Z" FRY REGLET DRMZ-25-25 WOOD FRAME AS SCHEDULED WOOD DOOR AS SCHEDULED14"1"ALIGN14"112"14"ALIGN2 10/05/21 BDC COMMENTS 2 3 10/21/21 BDC COMMENTS 3