HomeMy WebLinkAboutAPPROVED A5.1 EXTERIOR & INTERIOR DOOR SCHEDULE (2)MK MATERIAL
MAS. OPNG.
W X D
AREA
(S.F.)
DOOR TYPEDOOR
SIZE
NOTES
ALL GLASS IN EXTERIOR DOORS TO BE IMPACT RESISTANT AND TEMPERED
NOTE: SEE EXTERIOR ELEVATIONS ON STRUCTURAL PLANS FOR DOOR AND WINDOW DESIGN PRESSURES.
APPROVED PRODUCT APPROVALS FOR ALL EXTERIOR DOORS AND WINDOWS TO BE SUBMITTED WITH
PERMIT PLANS.
3080 W/ 2 LITES ALUM 44.80
EXTERIOR DOOR SCHEDULE
D-2
D-3
FRAME LOC .
EXTR
NOTES
D-4
D-5
18080 OVERHEADALUM144.0218" X 96"EXTRWD
3080
68" X 96"
24.0ALUM SWING ALUM EXTR
6080 SLIDINGALUM/GL 74" X 96"48.0 EXTRALUM
12080 146" X 96"96.00 ALUM EXTR
P.A. NO. -
D-1 SEE ELEVATION
40" X 96"
SWING / FRENCH
DOOR
ALUM/GL
(2) PANELS
(3) PANELS
ALUM
SEE ELEVATION
MATERIAL DOOR TYPE FRAME LOC .DOOR SIZE
2880 WD INT.WD
SOLID CORE
INTERIOR DOOR SCHEDULE
1
NOTES
2
3
4
SWING SELF-CLOSING TO BE MIN. 1-3/8" THICK SOLID
CORE OR 20 MIN. FIRE RATING
NOTES
ALL INTERIOR SWING DOORS TO BE HOLLOW CORE WITH RAISED PANELS U.N.O.
ALL GLASS IN INTERIOR DOORS AND ALL SLIDING GLASS DOORS TO BE TEMPERED.
ALL GLASS SHOWER AND TUB ENCLOSURES TO HAVE SAFETY GLASS PER FBCR.
ALL BATHROOMS TO HAVE MARBLE SADDLE TO COORDINATE W/ ADJACENT SELECTION.
ALL INT. SWING DRS. HAVE LEVER HANDLES, SATIN NICKEL COLOR- 'SCHLAGE' TORINO OR APPROVED EQUAL.
5
6
7
8
9
2680 WD INT.
3080 WD INTWD
2680 WD INTWD SWING
2880 WD INTWD SWING
2680 WD INTWD SWING
WD INTWD
BI-PASS
10 2480 WD INTWDSWING
SWING W/
CLOSER
11
2880 SWING
SWING
WD INTWD2880 SWING
3680 WD INTWDBARN PROVIDE SHOP DRAWINGS TO ARCHITECT FOR REVIEW
2480 WD INTWDSWING
WD
SLIDING
SHEET NUMBER
REVISIONS
This drawing is property of GMK, PALM BEACH,
FLORIDA. Any use of this drawing or the design
information hereon without written authorization of GMK
is strictly prohibited.
c 2021 GMK
PALM BEACH, FLORIDA
GMK
PLANNING - ZONING - DESIGN
G M KAGAN FAIA
205 WORTH AVENUE 201-111
PALM BEACH FL 33480
CELL: 203 988 1838
GMK@GMKPZD.COM
SOSNOWSKI RESIDENCE
Project Location:
3902 DUNESIDE DRIVE
FT PIERCE, FL 34949
CONSULTANTS
Project #: 2002
Architect: GERALD M. KAGAN
DATE : 08-25-2021
SHEET NAME:
SCALE: AS NOTED
PERMIT SET
INTERNATIONAL CONSULTING ENGINEERS &
DESIGN, LLC
4310 WEST BROWARD BLVD.
PLANTATION, FL 33317
T 561.707.6795 F 954.797.2847
CONTACT: JOE SPASOVSKI, P.E.
UNISONSTRUCTURALDESIGN
7522 WILES RD, SUITE B204
CORAL SPRINGS, FL 33067
PHONE: (954) 323-3746
MOBIL: (305) 298-0467
EMAIL:
UNISONSTRUCTURALDESIGN@GMAIL.COM
WEB:
UNISONSTRUCTURALDESIGN.COM
DATE : 10-06-2021
A5.1
EXTERIOR AND INTERIOR
DOOR SCHEDULE / DETAILS
INTERIOR DOOR JAMB DETAIL1SCALE: 3" = 1'-0"
INTERIOR DOOR HEAD DETAIL2SCALE: 3" = 1'-0"
DOOR NOTES:
1.ALL DOORS PER OWNER SELECTION. ALL DOORS SHALL BE ALUMINUM FRAME WITH CLEAR GLASS MIAMI DADE COUNTY APPROVED OR EQUAL. DOOR PERMIT IS REQUIRED
PRIOR TO ORDERING DOORS. SEE EXTERIOR ELEVATIONS
2.ALL EXTERIOR DOOR MASONRY OPENINGS SHALL BE COORDINATED BY DOOR COMPANY AND CONTRACTOR PRIOR TO PLACING EXTERIOR DOOR ORDER AND FRAMING OPENINGS.
4.EXTERIOR WINDOWS TO BE FLASHED WITH LIQUID WATERPROOFING BY KEMPER, TREMCO OR APPROVED EQUAL AROUND PERIMETER OF ALL WINDOW BUCKS. MEMBRANE TO EXTEND 12" MIN. FROM HEADER, JAMBS
AND SILL ON BOTH SIDES.
5. BUCKS:
A)SHALL BE PRESSURE TREATED.
B)FASTEN BUCK TO STRUCTURE PER STRUCTURAL DWG'S.
C)JOINT BETWEEN STRUCTURE AND WOOD BUCK SHALL BE CAULKED CONTINUOUSLY (AT HEAD AND JAMB).
D)JAMB BUCKS SHALL BE KEPT 12" OFF SILL BUCK IN ORDER TO AVOID WICKING OF MOISTURE FROM SILL BUCKS TO JAMB BUCKS.
6.SILL FLASHING AT WINDOWS AND DOORS: FULL DEPTH COPPER PAN W/ MULTI-STEPS, BREAKS IN THE PAN, SOLDERED SEAMS AND EXPANDED COPPER LATH. EXTEND MIN. 4" UP AND BULL IN. THE PANS ARE NOT
SIMPLE "L", FLASHING WITH THE CORNERS TURNED.
8. PROVIDE PEEL AND STICK FLASHING ABOVE AND BELOW COPPER FLASHING.
9. PROVIDE 1/4" BACKER ROD AND SEALANT BETWEEN BUCK AND DOOR OR WINDOW FRAME TO SEAL PASSAGE OF WATER FROM EXTERIOR INTO INTERIOR OF RESIDENCE. IF BRICKMOLD IS PRE-APPLIED, THEN THE
BACKER ROD AND SEALANT SHALL BE BETWEEN THE BRICKMOLD AND THE STUCCO OR STONE RETURN. DOOR COMPANY SHALL PRODUCE SHOP DRAWINGS FOR ARCHITECTS REVIEW PRIOR TO THEIR FABRICATION.
10. ALL EXTERIOR GLASS DOORS SHALL HAVE CATEGORY II SAFTEY-PLUS IMPACT GLASS.
11. ALL IMPACT RESISTANT GLASS TO BE CLEAR, LOW-E INSULATED GLASS. PROVIDE FINISH SAMPLES FOR OWNER/ARCHITECT APPROVAL.
12. INTERIOR DOORS TO BE PAINT GRADE WOOD UNLESS OTHERWISE NOTED. CONTRACTOR TO VERIFY ALL DOOR WIDTHS, WALL THICKNESS AND SWINGS IN FIELD PRIOR TO ORDERING.
13. ALL INTERIOR DOOR FRAMES TO BE PAINT GRADE WOOD WITHOUT FINGER JOINTS. VERIFY ALL FRAME WIDTH WITH WALL THICKNESS.
14. ALL DOOR HARDWARE HEIGHT TO BE 36" A.F.F. AND TO BE SELECTED BY OWNER/ARCHITECT, GENERAL CONTRACTOR TO COORDINATE WITH OWNER.
GLASS NOTE:
DOOR SCREW SIZE AND LOCATIONS AS PER APPROVED SHOP DWG'S AND APPROVED NOA'S.
*ALL DIMENSIONS SHALL BE VERIFIED IN FIELD PRIOR TO COMMENCE WORK.
**WINDOW AND DOOR INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS SET FORTH IN THE APPROVED NOA'S.
WOOD DOOR AS SCHEDULED
DOOR HINGE AS SCHEDULED
WOOD FRAME AS SCHEDULED
HD WD BLOCKING
RM01 14" REVEAL MOLDING,
"Z" FRY REGLET DRMZ-25-25
SEE PLAN FOR PARTITION
TYPE
14"1"1"14"
ALIGN
14"ALIGN
14"112"14"112"
SEE PLAN FOR PARTITION TYPE
MTL SUTD BOX BEAM AND FRAMING
HD WOOD BLOCKING
RM01 14" REVEL MOLDING, "Z" FRY REGLET
DRMZ-25-25
WOOD FRAME AS SCHEDULED
WOOD DOOR AS SCHEDULED14"1"ALIGN14"112"14"ALIGN2 10/05/21 BDC COMMENTS
2
3 10/21/21 BDC COMMENTS
3