Loading...
HomeMy WebLinkAboutAPPROVED Lot 33 TF Eenrgys and Heat loads 9.23.2021FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 4 /4 6kwla�- Let" Project Name: 3902 DUNESIDE DR 08-23-21S Builder Name: ! Street: 3902 DUNESIDE DRIVE Permit Office: FORT PIERCE City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: 661100 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type%2311.5 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, Exterior R=4.1 2071.50 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 Cl. N/A R= ft2 11. Ceiling Types (1988.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1988.00 ft2 6. Conditioned floor area above grade (ft2) 1988 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(477.3 sqft.) Description Area 12. Ducts R ft2 a. Sup: LIVING ROOM, Ret: LIVING ROOM, AH: LIV 6 793 a. U-Factor: Sgl, U=1.10 477.33 ft2 SHGC: SHGC=0.32 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 46.5 SEER:18.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 6.166 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.320 a. Electric Heat Pump 46.5 HSPF:10.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1988.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1988.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.240 Total Proposed Modified Loads: 63.20 PASS Total Baseline Loads: 63.59 hereby certify that the plans and specifications covered by Review of the plans and 4'TVLE SIP this calculation are in compliance with the Florida Energy Code. specifications covered by this indicates compliances,,, w©f _ :g Digitally by Joe Spasovsld calculation � F signed DN:c=U5, o=International c°nsaltingEngineesandDeslg"' with the Florida Energy Code. Before is PREPARED BY: _ construction completed _ DATE: _ 00001047•cn=JoeSpaso; this building will be inspected for A. ,,i -e-, Date: 2021.09.02 09:18:03 -04'00 compliance with Section 553.908 * u I hereby certify that this building, as designed, is in compliance Florida Statutes. 1� -' ��► CDD with the Florida Energy,de. WE OWNER/AG T. BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH60 (R402.4.1.2). 8/25/2021 7:48 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 3902 DUNESIDE DR 08-23-2 Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1988 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 3902 DUNESIDE DRIV Permit Office: FORT PIERCE Cross Ventilation: No County: St. Lucie Jurisdiction: 661100 Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL VERO BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Entire House 1988 19880 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BATH 200 2000 No 0 1 Yes Yes Yes 2 HIS 42 420 No 0 1 Yes Yes Yes 3 HERS 40 400 No 0 1 Yes Yes Yes 4 MASTER BERDOO 247 2470 No 2 1 1 Yes Yes Yes 5 FOYER 149 1490 No 0 1 Yes Yes Yes 6 LIVING ROOM 390 3900 No 0 1 Yes Yes Yes 7 KITCHEN 356 3560 Yes 0 1 Yes Yes Yes 8 LAUNDRY 63 630 No 0 1 Yes Yes Yes 9 GUEST ROOM 216 2160 No 1 1 1 Yes Yes Yes 10 GUEST BATH 56 560 No 0 1 Yes Yes Yes 11 POWDER 51 510 No 0 1 Yes Yes Yes 12 OFFICE 178 1780 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BATH 39 ft 200 ft2 ___ 0 1 0 2 Slab -On -Grade Edge Insulatio HIS 7ft 42 ft2 ___ 0 1 0 3 Slab -On -Grade Edge Insulatio HERS 7ft 40 ft2 0 1 0 4 Slab -On -Grade Edge Insulatio MASTER BERDO 27 ft 247 ft2 ___ 0 1 0 5 Slab -On -Grade Edge Insulatio FOYER lift 149 ft2 ___ 0 1 0 8/25/2021 7:48 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio LIVING ROOM 37 ft 390 ft2 0 1 0 7 Slab -On -Grade Edge Insulatio KITCHEN 9 ft 356 ft2 0 1 0 8 Slab -On -Grade Edge Insulatio LAUNDRY 6ft 63 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio GUEST ROOM 14 ft 216 ft2 0 1 0 10SIab-On-Grade Edge Insulatio GUEST BATH 6ft 56 ft2 ___ 0 1 0 11SIab-On-Grade Edge Insulatio POWDER 5 ft 51 ft2 0 1 0 12SIab-On-Grade Edge Insulatio OFFICE 39 ft 178 ft2 ___ 0 1 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2154 ft2 0 ft2 Medium N 0.9 No 0.9 No 20 22.62 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1988 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER BATH 0 Blown 200 ft2 0.1 Wood 2 Under Attic (Unvented) HIS 0 Blown 42 ft2 0.1 Wood 3 Under Attic (Unvented) HERS 0 Blown 40 ft2 0.1 Wood 4 Under Attic (Unvented) MASTER BERDO 0 Blown 247 ft2 0.1 Wood 5 Under Attic (Unvented) FOYER 0 Blown 149 ft2 0.1 Wood 6 Under Attic (Unvented) LIVING ROOM 0 Blown 390 ft2 0.1 Wood 7 Under Attic (Unvented) KITCHEN 0 Blown 356 ft2 0.1 Wood 8 Under Attic (Unvented) LAUNDRY 0 Blown 63 ft2 0.1 Wood 9 Under Attic (Unvented) GUEST ROOM 0 Blown 216 ft2 0.1 Wood 10 Under Attic (Unvented) GUEST BATH 0 Blown 56 ft2 0.1 Wood 11 Under Attic (Unvented) POWDER 0 Blown 51 ft2 0.1 Wood 12 Under Attic (Unvented) OFFICE 0 Blown 178 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belowo It Ornt Tn Wall Type Space e Et In Ft In Area P-\/,ql,le Fraction Ahqnr 1 N Exterior Concrete Block - Ext lnslAASTER BA 4.1 12 3 9 0 110.3 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Ext InsMASTER BA 4.1 12 3 9 0 110.3 ft2 0 0 0.6 0 3 W Exterior Concrete Block - Ext InskfiASTER BA 4.1 18 11 9 0 170.3 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Ext Insul HIS 4.1 7 9 9 0 69.8 ft2 0 0 0.6 0 8/25/2021 7:48 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo Space Et In Et In Area P-\/.qllle PraCtinn AhSnr w 5 S Exterior Concrete Block - Ext Insul HERS 4.1 7 9 9 0 69.8 ft2 0 0 0.6 0 6 N Exterior Concrete Block - Ext InsAAASTER BE 4.1 17 9 9 0 159.8 ft2 0 0 0.6 0 7 E Exterior Concrete Block - Ext Ins1AASTER BE 4.1 12 3 9 0 110.3 ft2 0 0 0.6 0 _ 8 W Exterior Concrete Block - Ext Insul FOYER 4.1 12 3 9 0 110.3 ft2 0 0 0.6 0 9 N Exterior Concrete Block - Ext Insk VING ROO 4.1 22 3 9 0 200.3 ft2 0 0 0.6 0 -10 E--- -Exterior Concrete-Block--Ext-Ins1JVING ROO _ -4.1 --- 18 11 9 --- 0 -170.3 ft2 - 0--- 0-- O:6 - 0 -- 11 E Exterior Concrete Block - Ext InsuKITCHEN 4.1 10 0 9 0 90.0 ft2 0 0 0.6 0 12 S Exterior Concrete Block - Ext InsuLAUNDRY 4.1 6 8 9 0 60.0 ft2 0 0 0.6 0 _ 13 S Exterior Concrete Block - Ext lnsBUEST ROO 4.1 15 7 9 0 140.3 ft2 0 0 0.6 0 14 S Exterior Concrete Block - Ext lnsGUEST BAT 4.1 6 8 9 0 60.0 ft2 0 0 0.6 0 15 S Exterior Concrete Block - Ext InsuPOWDER 4.1 5 7 9 0 50.3 ft2 0 0 0.6 0 16 N Exterior Concrete Block - Ext Insul OFFICE 4.1 13 4 9 0 120.0 ft2 0 0 0.6 0 17 E Exterior Concrete Block - Ext Insul OFFICE 4.1 15 7 9 0 140.3 ft2 0 0 0.6 0 18 S Exterior Concrete Block - Ext Insul OFFICE 4.1 14 5 9 0 129.8 ft2 0 0 0.6 0 19 W Garage Frame - Wood LAUNDRY 11 10 10 100.0 ft2 0.23 0.6 0 _20 W Garage Frame - Wood KITCHEN 11 14 10 140.0 ft2 0.23 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Wood KITCHEN None .46 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Tinted) Yes 1.1 0.32 N 4.0 ft2 2 ft 0 in 0 ft 6 in None None 2 W 3 Metal Single (Tinted) Yes 1.1 0.32 N 26.0 ft2 2 ft 0 in 0 ft 6 in None None 3 N 6 Metal Single (Tinted) Yes 1.1 0.32 N 36.0 ft2 2 ft 0 in 0 ft 6 in None None 4 E 7 Metal Single (Tinted) Yes 1.1 0.32 N 45.0 ft2 2 ft 0 in 0 ft 6 in None None 5 W 8 Metal Single (Tinted) Yes 1.1 0.32 N 45.3 ft2 7 ft 0 in 4 ft 0 in None None 6 W 8 Metal Single (Tinted) Yes 1.1 0.32 N 15.0 ft2 7 ft 0 in 1 ft 6 in None None 7 W 8 Metal Single (Tinted) Yes 1.1 0.32 N 13.0 ft2 7 ft 0 in 4 ft 0 in None None 8 N 9 Metal Single (Tinted) Yes 1.1 0.32 N 30.0 ft2 2 ft 0 in 1 ft 6 in None None 9 E 10 Metal Single (Tinted) Yes 1.1 0.32 N 97.0 ft2 2 ft 0 in 0 It 6 in None None 10 E 11 Metal Single (Tinted) Yes 1.1 0.32 N 49.0 ft2 25 ft 0 in 0 ft 6 in None None 11 S 12 Metal Single (Tinted) Yes 1.1 0.32 N 4.0 ft2 2 ft 0 in 0 ft 6 in None None 12 S 13 Metal Single (Tinted) Yes 1.1 0.32 N 36.0 ft2 2 ft 0 in 0 ft 6 in None None 13 S 14 Metal Single (Tinted) Yes 1.1 0.32 N 4.0 ft2 2 ft 0 in 0 ft 6 in None None 14 S 15 Metal Single (Tinted) Yes 1.1 0.32 N 4.0 ft2 2 ft 0 in 0 ft 6 in None None 15 N 16 Metal Single (Tinted) Yes 1.1 0.32 N 45.0 ft2 13 It 0 in 0 ft 6 in None None 16 E 17 Metal Single (Tinted) Yes 1.1 0.32 N 24.0 ft2 2 ft0 in 0 ft6 in None None 8/25/2021 7:48 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 489 ft2 489 ft2 64 It loft 4.1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000444 2319.3 127.25 238.89 .1381 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Singl HSPF:10 46.5 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 18 46.5 kBtu/hr 1550 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None 11:2 DUCTS / V # --- Supply — Location R-Value Area -- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 LIVING ROO 6 793 ft2 LIVING ROO 793 ft2 Default Leakage LIVING RO (Default) (Default) 1 1 8/25/2021 7:48 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb Mar Apr May X Jun X Jul X Aug Se Oct Nov Dec Heatin�X Jan f X Feb Mar ki Apr May 4 Jun 4 i Jul r Au4 Sep Oct Nov Dec Ventin [[ Jan [ Feb Mar [X A r [ Ma [ Jun [ Jul Aug [ Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ftZ ft 0.3 HIS Default(8 Ibs/sq.ft. f12 ft 0.3 HERS Default(8 Ibs/sq.ft. f12 ft 0.3 MASTER BERD00 Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. f12 ft 0.3 LIVING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 GUEST ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 GUEST BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 POWDER Default(8 Ibs/s .ft. ft2 ft 0.3 OFFICE 8/25/2021 7:48 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (W 7. Windows- Description a. U-Factor: Sgl, U=1.10 SHGC: SHGC=0.32 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 3902 DUNESIDE DRIVE, FORT PIERCE, FL, New (From Plans) 10. Wall Type and Insulation Insulation Area a. Concrete Block - Ext Insul, Exterior R=4.1 2071.50 ft2 Detached b. Frame - Wood, Adjacent R=11.0 240.00 ft2 1 c. N/A R= ft2 2 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area No a. Roof Deck (Unvented) R=20.0 1988.00 f12 1988 b. N/A R= ft2 c. N/A R= ft2 Area 12. Ducts, location & insulation level R ft2 477.33Area ft2 a. Sup: LIVING ROOM, Ret: LIVING ROOM, AH: LIV 6 793 ft2 13. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 46.5 SEER:18.00 ft2 6.166 ft. 0.320 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1988.00 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: Q �., _ City/FL Zip: 2zlSy kBtu/hr Efficiency 46.5 HSPF:10.00 Cap: 50 gallons EF: 0.95 Pstat �14E STq?� `Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/25/2021 7:48 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction: 661100 Permit #: Job Information Builder: l- Community: Lot:?, j NA � x4k Address: 3902 DUNESID DRIVE City: FORT PIERCE State: FL Zip: Air Leakage Test ReSUItS Passing results must meet either the Performance, Prescriptive, or ERI Method O PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2, O PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on Farm R405-2020 (Performance) or R406-2020 (ERI), section labeled as infiltration, sub -section ACH50. ACH(50) specified on Form R405-2020-Energy Calc (Performance) or R406-2020 (ERI): 7.000 x 60 _ 19880 = Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans ❑ PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 8/25/2021 7:49:05 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1