HomeMy WebLinkAboutAPPROVED P - 3902 DUNESIDE DR 09-01-21G-P-2W / D
STACKED36"FRIDGE24"
D.W.
U.C.
MICRO
(OPTIONAL)
WH
ELECT. RANGE
W/ HOOD
LAUNDRY
DINING
GUEST ROOM
OFFICE
HIS
COVERED
ENTRY
MASTER
BEDROOM
MASTER BATH
LIVING ROOM
FOYER
COVERED LANAI
GUEST BATH
PWDR
CLOSET
2 CAR GARAGE
KITCHEN
HERS
MATER HALL
POOL DECK
SCALE:1 WATER HEATER (WH) W/RECIRCULATION DIAGRAM
NOT TO SCALE
PROVIDE A WATER TIGHT,
GALVANIZED STEEL PAN, MIN.
2" DEEP x 24 GA., BELOW HOT
WATER HEATER (FURNISHED
AND INSTALLED BY PLUMBER)
TEMPERATURE
& PRESSURE
RELIEF VALVE
CW
FINISHED
FLOOR
HW TO FIXTURES
VACUUM RELIEF VALVE 6" ABOVE WATER
HEATER. WATTS #289 OR EQUAL
SHUT-OFF VALVE (TYPICAL)
CHECK VALVE (TYPICAL)
UNION (TYPICAL)
THERMAL EXPANSION TANKT/P
AQUASTAT
RECIRCULATING HW PUMP (RHWP)
BALANCING VALVE TO BALANCE SYSTEM
HW RETURN PIPING
DRAIN LINE PIPE FULL SIZE
DOWN INTO DRAIN PAN
DRAIN VALVE W/ 3/4"
THREADED OUTLET
GENERAL NOTES:
DRAIN VALVE SHALL CONFORM TO ASSE 1005.
THE VACUUM RELIEF VALVE SHALL COMPLY WITH ANSI Z21.22.
THE TEMPERATURE AND PRESSURE VALVE SHALL BE SELF
CLOSING (LEVERED) CONFORMING TO ANSI Z21.22.
INSTALL HEAT TRAP ON SUPPLY AND DISCHARGE PIPING
NEAR WATER HEATER. TRAP TO BE MINIMUM OF 18" DEEP
CENTER TO CENTER.
ALL WATER HEATERS AND HOT WATER PIPING MUST COMPLY
TO (2012) IECC STANDARDS, SECTION 404.4, 404.5, 404.6
CONCERNING HEAT TRAPS, PIPE INSULATION AND CONTROLS.
HWR
HEAT TRAP
HEAT TRAP
DRAIN LINE TO
EXTERIOR MIN. 12"
FROM BUILDING & 6"
ABOVE GRADE
W/ INSECT SCREEN.
SHEET NUMBER
Distribution
This drawing is property of GMK, PALM BEACH,
FLORIDA. Any use of this drawing or the design
information hereon without written authorization of GMK
is strictly prohibited.
c 2021 GMK
PALM BEACH, FLORIDA
GMK
PLANNING - ZONING - DESIGN
G M KAGAN FAIA
205 WORTH AVENUE 201-111
PALM BEACH FL 33480
CELL: 203 988 1838
GMK@GMKPZD.COM
SOSNOWSKI RESIDENCE
Project Location:
3902 DUNESIDE DRIVE
FT PIERCE, FL 34949
CONSULTANTS
Project #: 2002
Architect: GERALD M. KAGAN
DATE : 08-25-2021
SHEET NAME:
SCALE: AS NOTED
PERMIT SET
INTERNATIONAL CONSULTING ENGINEERS &
DESIGN, LLC
4310 WEST BROWARD BLVD.
PLANTATION, FL 33317
T 561.707.6795 F 954.797.2847
CONTACT: JOE SPASOVSKI, P.E.
4310 West Broward Blvd,Plantation FL 33317
Joe Spasovski, P.E.
Certificate of Authorization#30734FL P.E.#76217
SEAL
JO E S ASO
V
S
PLIC EN
S
E
No 76217
STATE OF
FLOR I D ARO
FE
S
S NAO E N GINEERL
P
I
K
I P-2
WATER FLOOR PLAN & DETAILS