HomeMy WebLinkAboutAPPROVED Therma-Tru Product Evaluation ReportR W R W Building Consultants, Inc.
B Consulting and Engineering Services for the Building Industry
C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197
Florida Board of Professional Engineers Certificate of Authorization No. 9813
Product
Category
Sub Category
Manufacturer
Product Name
Therma Tru Corporation
"Classic Craft" and "Classic Craft Rustic Series"
Exterior
Swinging
Exterior Door
118 Industrial Drive
Opaque Fiberglass Door
Doors
Assemblies
Edgerton, OH 43517
Inswing / Outswing
Phone 419.298.1740
"Impact"
Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID It
1998) for Therma Tru Corporation based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval,
Department of Business & Professional Regulation.
RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein.
Limitations:
1. This product has been evaluated and is in compliance with the 5th Edition (2014) Florida Building Code (FBC) excluding the "High
Velocity Hurricane Zone".
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in wind-borne debris regions this product complies with section 1609.1.2 of the FBC as an impact resistant product and does
not require the use of an external impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in
ASTM E 1996 and Section 1609.1.2.2 of the FBC.
4. For 2X stud framing construction, anchoring of these units shall be the same as that shown for 2X buck masonry construction.
5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered
architect.
6. See drawing FL-6993.1 for size and design pressure limitations.
Supporting Documents:
1. Test Report No.
TEL 2005-02-21-004
TEL 06-1031-4
2. Drawing No.
No. FL 6993.1
3. Calculations
Anchoring
Test Standard
ASTM E330-02
ASTM E 1886/1996-02
ASTM E331-02
Prepared bV
RW Building Consultants, Inc. (CA #9813)
Prepared by
RW Building Consultants, Inc. (CA #9813)
4. Quality Assurance
Certificate of Participation issued by National Accreditation and Management
Institute, certifying that Therma Tru Corporation is manufacturing products
within a quality assurance program that complies with ISO/IEC 17020 and
Guide 53.
Sheet 1 of 1
Testing Laboratory Signed by
Testing Evaluation Lab.,lnc. Wendell W. Haney, P.E.
Testing Evaluation Lab.,lnc. Wendell W. Haney, P.E.
Signed & Sealed by
Lyndon F. Schmidt, P.E.