HomeMy WebLinkAboutAPPROVED Lot 33 Tf Window loads Calc 9.23.2021Digitally signed by Kervin Ventura t Kervin DN: c=US, L�. .�. , Planning & Development Services Department o=UNISON Building & Code Regulations Division STRUCTURAL �_/_�y� DESIGN LLC, 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 4E]]��''�1 l } dnQualifier-A0141 ODOOOOO179322DF Certification for Design Load Compliance ra 43800011 EA1, 7th Edition cn=Kervin Ventura Date: 2021.08.30 Project Name: S OS no WSKC Qe-gt Jew-e 11:04:28-04'00' Project Address:Mn X)vnstd•c irija . Forf Rcrc.c r FL 3 `fgyg Permit #: Occupancy Type:JZ 3ConstructionType: 1% Q INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally signed electronic version. • If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still required • All digital files must be in an unlocked Portable Document Format (PDF) version * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2 o ZD Code 7th Edition using ASCE 7-16 2. Structure Designed as (check one): Enclosed Partially Enclosed Open 3. Risk Category: 1 1✓11 III IV Exposure Category: B C VS4. Design Wind Velocity 1:? 0 mph_IL/ASD LRFD End Zone Width: $ • —Ift 5. Mean Roof Height 13 ft Roof Pitch: S :12 Parapet: MIA ft 6. Components & Cladding Design Pressures Used: f -F4 5•OV ♦4S•A ♦ 0 _ SCE $�'ruGc• �tG+1 $ Zone 4: y9• Zone 5: GI'y Garage: 4}•� 6a. Roofs Maximum +/- pressures: + 34*?. psf - S14 psf Or define individual zones on the plans 7. Design Loads: Floor: 3!110 PSF Roof -Dead: 25 PSF Roof -Live: 30 Balcony+/- 30%e PSF SeC S{f v Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF RkA SS'0 8. Were Shear Walls Considered For Structure? Yes ✓ Not Applicable Pleqse Explain: 9. Is a Continuous Load Path Provided? ✓ Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? es No Assumed DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply witNOA ,4Rpljy]u� ��!!ftqctural portions of the current Florida Building Code as adopted. Sign;3Lj*qDate, andS'eal ��:� STATE OF io ,n •. � to. Revised 14 R 10.•'��`�� iS��NA� ,�?% -Print Name Cert # & Co. CertofAuthorization Wmoo or az W;lct i2�1, siti& 6 Zoy, Cyr so�rlitts FL Company Name & Address 330G ?