Loading...
HomeMy WebLinkAboutAPPROVED STRUCTURAL SET7'-7"7'-7"4 S2.0 4'-0"4'-8"4'-7 1/2"8'-0"7'-0 1/2" 1 1 SEE NOTE # 9 TE-1 TE-1TE-1TE-1 GROUND FLOOR ELEV.: 0'-0" (+6.10' N.A.V.D) 4" CONC. SLAB, SEE NOTE # 1 13'-5" 11'-2"3'-10"16'-7"5'-0"4'-5"4'-5"18'-0"2'-10"5'-11"33'-9 1/2"20'-2"15'-10 1/2"15'-0"10'-9"6'-10 1/2"5'-9 1/2"15'-10" 66'-0 1/2"2'-5"6'-0"2'-5"2'-6" 5'-3 1/2"2'-9"2'-9"10'-9"23'-7"17'-10 1/2"1'-2"4'-10"6'-10"8'-8"2'-9"2'-9"14'-8 1/2"4'-10"5'-4"4'-10"3'-2"1'-4"11'-3 1/2" 10'-8" 4"4" 4" 5'-0" 4" 4" 4" 2" SLOPE 2" MIN. 11'-2" 10'-3" 10 1 10 MC-1 9'-1"5'-7"6'-1"27'-6" 1 S2.0 2 S2.0 SEE NOTE # 3 (TYP.) C.J. MF-24 MF-24 MF-24MF-242 S2.0 SEE NOTE # 10 (TYP.) MF-24 MF-36MF-24 10 S2.0 x x x x x x x SEE NOTE # 14 (TYP.)1'-2"3'-6" F-60 6 S2.0 7 S2.0 F-40 TE-28 S2.0 F-40 7 S2.0 MF-24 F-60 6 S2.0TE-1TE-1TE-1TE-1 TE-1 5 S2.0 TE-15 S2.0 4 S2.1 x x x x x x x SEE NOTE # 14 (TYP.) 2 S2.0 MF-24 1 S2.0 TE-1 1 S2.1 2 S2.0MF-24MF-244 S2.0 MF-36 3 S2.0 MF-363 S2.0MF-24MF-24 1 S2.0 SEE NOTE # 3 (TYP.) C.J. SEE NOTE # 10 (TYP.) 11 S2.0MF-24TE-1TE-42 2 1 S2.1 2 S2.0 TE-1SEE NOTE # 13 (TYP.)TE-1SEE NOTE # 13 (TYP.) SEE NOTE # 13 (TYP.)MF-244'-10" 9 S2.04"4"3'-4"PAVERS ON SAND F-40 MC-1 F-40 F-40 MC-1 MC-1 F-40 MC-1MC-1MF-24MF-36 MF-36 SEE NOTE # 15 (TYP.) SEE NOTE # 15 (TYP.) 9 S2.0 F-40 F-40 5'-0"6'-3"7'-9"2'-5"3'-10"FOUNDATION PLAN NOTES: 1.THE NEW FLOOR SLAB SHALL BE 4" CONCRETE SLAB w/ 6 x 6 W1.4 x W1.4 W.W.F. ON 10 MIL VAPOR BARRIER OVER CLEAN COMPACTED, TERMITE TREATED, SUB GRADE (TYP.) 2.TOP OF FOOTING SHALL BE MIN. 12" BELOW ADJACENT FINISHED GRADE . SOIL BEARING CAPACITY = 2,500 PSF. SEE GEOTECHNICAL SOIL REPORT. 3.PROVIDE CONSTRUCTION / CONTRACTION JOINTS IN THE SLAB AT INTERVALS NOT TO EXCEED 12'-0"o.c. IN EACH DIRECTION. SEE DETAIL 3/S2.1. 4.ALL FOOTINGS ARE CENTERED BENEATH BEARING WALLS AND COLUMNS, TYPICAL OR UNLESS NOTED OTHERWISE. 5.COORDINATE TOP OF SLAB WITH FINAL FLOOR FINISHES, SLAB RECESSES, AND FLOOR SLOPES. SEE ARCHITECTURAL PLAN FOR FINISH ELEVATIONS. 6. INDICATES 8" CONCRETE MASONRY UNITS w/ (1) # 5 @ 32"o.c. (MAX.) IN GROUT FILLED CELL AT WALLS UNLESS NOTED OTHERWISE. INDICATES 8" CONCRETE MASONRY UNITS w/ (1) # 5 @ 48"o.c. (MAX.) IN GROUT FILLED CELL AT WALLS UNLESS NOTED OTHERWISE. INDICATES 8" CONCRETE MASONRY UNITS w/ (2) # 6 IN GROUT FILLED CELL AT WALLS UNLESS NOTED OTHERWISE. 7.PROVIDE #9 LADDER TYPE JOINT REINFORCING @ 16"o.c. (EVERY 2nd. COURSE) FOR CONCRETE MASONRY UNIT WALL. 8.COORDINATE THIS DRAWING w/ ARCHITECTURAL DRAWINGS FOR DOOR AND WINDOW ROUGH OPENINGS DIMENSIONS & LOCATIONS. 9.6" THICK, MECHANICAL CONCRETE PAD w/ (2) LAYERS OF 6 x 6 w1.4 x w1.4 w.w.F. ON 10 MIL VAPOR BARRIER OVER CLEAN COMPACTED, TERMITE TREATED, SUB GRADE. COORDINATE w/ MECHANICAL. TYPICAL. SEE DETAIL 6/S2.1. 10.PROVIDE (2) # 4 x 4'-0" CRACK BARS AT ALL RE-ENTRANT CORNERS. 11.ALL WINDOWS SILLS UP TO 7'-0" WIDE SHALL BE CAP w/ 8 x 8 CONCRETE REINFORCED WITH (2) # 5 MID EXTENDED 5" MIN. INTO ADJACENT GROUT FILLED CELLS. FOR WINDOWS WIDER THAT 7'-0", USE 8 x 12 CAP BEAM WITH (2) # 5 TOP AND BOTT AND ENCLOSED WITH # 3 @ 8"o.c. STIRRUPS. 12.ALL MASONRY WALLS, PIERS AND COLUMNS SHALL BE RUNNING BOND PERPENDICULAR. WALLS SHALL BE INTERLOCKED WITHIN THE RUNNING BOND PATTERN. 13.MONOLITHIC FOOTING TRANSFER BAR # 4 x 5'-0" @ 16"o.c. PLACE AT SLAB MID-DEPTH (TYP.). 14.PROVIDE DOUBLE LAYER OF 6 x 6 - W1.4 x W1.4 W.W.F. EXTENDING 3'-0" EACH SIDE. 15.PROVIDE 'U' OR 'Z' TYPE RIGID STEEL ANCHOR 16GA, 1-1/2" x 32" LONG @ 16"o.c., NON CONCURRENT w/ LADDER REINFORCEMENT (TYP.). 16.SEE SHEET S5.0 FOR COLUMN AND FOOTING SCHEDULE. SHEET NUMBER Distribution This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 07-06-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET KERVIN VENTURA 7522 WILES RD., SUITE B204, CORAL SPRINGS, FL. 33067 UNISONSTRUCTURALDESIGN@GMAIL.COM - TEL.: (305) 298-0467 PERMIT SET: 08-27-2021 NORTHFOUNDATION PLAN FOUNDATION PLAN SCALE: 1/4" = 1' S1.1 4 S3.0 1.8 SEE NOTE # 3 (TYP.)SEE NOTE # 3 (TYP.)0.6 1.8 0.8 2.0 2LB-1 (EL.: +9'-4")2BB-1 (EL.: +9'-4") 0.8 3.4 2.0 3.9 3.9 G.T.0.8 2.0 5.4 1 1 2.03.3G.T.0.8 6.2G.T.G.T.G.T.G.T.3.9 0.8 2.0 2BB-1 (EL.: +10'-8") 0.8 2.0 2B-2 (EL.: +9'-4") 4.4 2.0 3.9 2.04.4 2.5 2.0 5.4 G.T.G.T.G.T. G.T.G.T.4 S3.0 2.2 2.02BB-1(EL.: +9'-4")2B-4 (EL.: +8'-6")2B-2 (EL.: +9'-4") 2BB-1 (EL.: +9'-4")2B-1 (EL.: +9'-4")2BB-1 (EL.: +9'-4") 2BB-1 (EL.: +9'-4")2BB-1(EL.: +9'-4")2BB-4 (EL.: +13'-3")2BB-3 (EL.: +10'-2")2BB-1 (EL.: +9'-4") 2LB-1 (EL.: +9'-4") 2BB-1 (EL.: +9'-4") 1.2 2.0 2.0 4 S3.0 1.2 SEE DETAIL 3/S3.1 8.2 SEE DETAIL 3/S3.1 SEE DETAIL 2/S3.1 0.8 0.71.41.0 0.7 0.7 0.7 1.8 0.8 1.2 0.7 0.7 1.4 0.6 0.70.9 1.4 8.5 1 S3.0 2 S3.0 G.T.1.52.3 5.2 2.02.0 1.8 2.3 10 10 SEE DETAIL 1/S3.1 1 SEE NOTE # 9 (TYP.) SEE NOTE # 9 (TYP.) MC-1 MC-1 MC-1 MC-1 2.5 27'-6" 2BB-4 (EL.: +13'-3")2BB-2 (EL.: +13'-3")2BB-4 (EL.: +13'-3") SEE NOTE # 10 SEE NOTE # 10 8.0 2B-3 (EL.: +9'-4")2 2 SEE NOTE # 9 (TYP.) 4 S3.1 4 S3.0 5 S3.0 0.6 2BB-1 (EL.: +9'-4")2B-2 (EL.: +9'-4")2LB-1 (EL.: +9'-4")MC-1 5'-0"6'-3"7'-9"#.#1.0 ROOF FRAMING PLAN NOTES: 1.THE ROOF STRUCTURE IS 5/8" C.D.X. PLYWOOD ON PRE ENG. WOOD TRUSSES AT 24"o.c. PLYWOOD NAILING: SEE SHEET 'S6.0' FOR BLOCKED DIAPHRAGM DETAIL. 2.PRE ENG. WOOD TRUSSES SHALL BE DESIGNED FOR A SUPERIMPOSED LIVE LOAD OF 30 lbs/sqft AND A DEAD LOAD OF 25 lbs/sqft. AT ATTIC TRUSSES, DESIGN TRUSS BOTTOM CHORD FOR ADDITIONAL DEAD LOAD OF 10 lbs/sqft AND LIVE LOAD OF 20 lbs/sqft (UNINHABITABLE ATTIC w/ STORAGE). TRUSS DESIGN AND INSTALLATION SHALL COMPLY WITH THE FLORIDA BUILDING CODE. TRUSS DESIGNER SHALL SUBMIT SHOP DRAWINGS. TRUSS MANUFACTURER MUST SUPPLY ON TRUSS CALCULATIONS COMPONENTS AND CLADDING UPLIFT VALUES. INDICATE ALL REQUIRED CONNECTIONS, BRIDGING, CROSS BRACING AND LAY OUT AND SHALL BEAR THE SEAL OF A FLORIDA REGISTERED ENGINEER. ALL TRUSS TO TRUSS CONNECTIONS ARE THE RESPONSIBILITY OF THE TRUSS SPECIALTY ENGINEER. 3.PROVIDE PERMANENT BRACING OF TRUSSES IN ACCORDANCE WITH THE REQUIREMENTS OF 'BRACING WOOD TRUSSES: COMMENTARY AND RECOMMENDATIONS' PREPARED by 'TRUSS PLATE INSTITUTE, INC.' SEE DETAILS ON 'S6.0'. 4.THE TRUSS FRAMING LAYOUT SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED FOR THE TRUSS ENGINEER TO CLOSELY MATCH FINAL TRUSS DESIGN, WITHOUT ALTERING LOAD PATHS. IF TRUSS ENGINEER ENCOUNTERS PROBLEMS WITH OUR ROOF TRUSS LAYOUT, PLEASE CONTACT UNISON STRUCTURAL DESIGN, LLC. IMMEDIATELY TO DISCUSS POSSIBLE SOLUTIONS. 5.TRUSS MANUFACTURER TO COORDINATE VAULTED CEILINGS AND ATTIC SPACE WITH ARCHITECTURAL DWGS. 6. DESIGNATES UPLIFT IN KIPS (1.0k = 1,000 lbs). = 1.0 kip OF UPLIFT. SEE UPLIFT TIE-DOWN SCHEDULE ON SHEET 'S6.0' FOR APPROPRIATE TIE DOWNS. 7.WHERE BEAMS ARE NOT DESIGNATED OVER 8" CMU WALL OPENINGS PROVIDE 8x8 PRE CAST LINTEL ("PCL") w/ (1) #5, BOTTOM AND GROUT LINTEL AND C.M.U. ABOVE SOLID, OR REFER TO REINFORCED CAST-IN-PLACE CONCRETE LINTEL DETAIL ON '1/S5.1'. 8.PROVIDE 2x4 BLOCKING @ 32"o.c. ATTACHED TO TRUSS BOTT. CHORD w/ SIMPSON LUS24 HANGER AND ATTACHED TO WALL w/ SIMPSON HGAM10 CLIP w/ (4) 1/4"Ø x 2" LONG TAPCON AND (4) SDS 1/4"Ø x 2" SCREWS. 9.CONTRACTOR AND TRUSS MANUFACTURER TO COORDINATE ROOF HATCH RECESS LOCATION WITH RESPECT TO TRUSS LAYOUT. 10.PROVIDE (2) 2 x 12 PT LEDGER w/ 3/4" Ø SIMPSON TITEN HD @ 12"o.c. MAX., EMBEDDED INTO CONCRETE OR GROUT FILLED CELL. SHEET NUMBER Distribution This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 07-06-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET KERVIN VENTURA 7522 WILES RD., SUITE B204, CORAL SPRINGS, FL. 33067 UNISONSTRUCTURALDESIGN@GMAIL.COM - TEL.: (305) 298-0467 PERMIT SET: 08-27-2021 NORTHROOF FRAMING PLAN ROOF FRAMING PLAN SCALE: 1/4" = 1' S1.2 SEEPLAN8" MIN. 3'-0" DBL. MESH3'-0" DBL. MESH (1) #5 CONT. COMPACT CLEAN FILL. EL.: SEE PLAN TOP OF CONC. 8x12 MIN. CONT. THICKENED EDGE. SEE PLAN & SCHEDULE. SCALE: SECTION 3/4"=1'-0" 5 S2.0 SCALE: SECTION 3/4"=1'-0" 6 S2.048 BAR DIAMETER.3/4" RECESS3'-0" DBL. MESH 3/4"RECESS3'-0" DBL. MESH 3" CLR. TYP. SEE FTG. SCHD.3" CLR. TYP.SEE FTG. SCHD.3" CLR. TYP. SEE FTG. SCHD.SEE FTG. SCHD.3" CLR. TYP.x x x x x x x x x x x x x x #9 LADDER TYPE JOINT REINFORCING @ 16" o.c. VERTICAL SPACING. 8" CMU WALL REINFORCING BAR IN CONC. FILLED CELL (SEE PLAN FOR SIZE AND SPACING). CONCRETE SLAB ON GRADE. SEE PLAN AND PLAN NOTES. #4 x 5'-0" AT SLAB MID-DEPTH. COMPACT CLEAN FILL. CONTINUOUS MONOLITHIC FOOTING (SEE PLAN & SCHEDULE) 8" CMU WALL #9 LADDER TYPE JOINT REINFORCING @ 16" o.c. VERTICAL SPACING. # 6 BAR IN CONC. FILLED CELL @ 40"o.c. (MAX.) COMPACT CLEAN FILL. CONTINUOUS MONOLITHIC FOOTING (SEE PLAN & SCHEDULE) xx x x x xx xx xx x x x ELEV: SEE ARCH. DWGS. EXT. FIN. GRADE. EXT. FIN. GRADE. CONCRETE SLAB ON GRADE. SEE PLAN AND PLAN NOTES. # 4 x 5'-0" AT SLAB MID-DEPTH. SCALE: SECTION 3/4"=1'-0" 1 S2.0 SCALE: SECTION 3/4"=1'-0" 2 S2.0 3" CLR. TYP. SEE FTG. SCH. (TYP.)3" CLR. TYP.1 1/2" RECESS COMPACT CLEAN FILL. CONTINUOUS MONOLITHIC FOOTING (SEE PLAN & SCHEDULE) x x x x x x x x x x x x SEE ARCH FOR DOOR THRESHOLD EL.: SEE PLAN FIN. FLR. SLAB SCALE: SECTION 3/4"=1'-0" 3 S2.0 # 4 x 5'-0" AT SLAB MID-DEPTH. x x x x x CONCRETE SLAB ON GRADE. SEE PLAN AND PLAN NOTES. WINDOW OPENING UP TO 7'-0": 8" x 8" CONC. BEAM SILL w/ (2) #5 BAR CONT. EXTENDED 5" MIN INTO ADJACENT FILLED CELLS. WINDOW OPENING LARGER THAN 7'-0": 8" x12" CONC. BEAM SILL w/ (2) #5 TOP & BOTT. AND #3 @ 8"o.c. STIRRUPS EXTENDED 8" MIN INTO ADJACENT FILL CELLS OR COLUMN. TYP.SEE FTG.SCH. (TYP.)RECESS SEE ARCH. SCALE: SECTION 3/4"=1'-0" 10 S2.0 COMPACT CLEAN FILL. CONCRETE SLAB. SEE PLANS FOR SLAB THICKNESS AND REINFORCEMENTS. CONTINUOUS MONOLITHIC FOOTING (SEE PLAN & SCHEDULE) SEE ARCH. FOR STEP AND THRESHOLD. x x x x x x x x (1) #5 CONT. WELDED WIRE FABRIC REINF.xxxxxxxxxxxxxxxxxxxxx x x x x x x x x x x x x x x x x xxxxxxxxxxxxxxxxxxxxxxxxxSCALE: DETAIL 3/4"=1'-0" 9 S2.0 #9 LADDER TYPE JOINT REINFORCING @ 16" o.c. VERTICAL SPACING. REINFORCING BAR IN CONC. FILLED CELL (SEE PLAN FOR SIZE AND SPACING). 8" CMU WALL COMPACT CLEAN FILL. CONCRETE SLAB. SEE PLANS FOR SLAB THICKNESS AND REINFORCEMENTS. CONTINUOUS MONOLITHIC FOOTING (SEE PLAN & SCHEDULE) 3/4" RECESS WELDED WIRE FABRIC REINF. (1) #5 CONT.xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxEL.: SEE PLAN FIN. FLR. SLAB EL.: SEE PLAN FIN. FLR. SLAB EL.: SEE PLAN FIN. FLR. SLAB EL.: SEE PLAN FIN. FLR. SLAB3" CLR. TYP.SEE FTG. SCH. TYP.SEE FTG.SCH. (TYP.)3" CLR. TYP. 2"9"SEE PLAN (TYPICAL) SEE PLAN (TYPICAL) ISOLATED FOOTING (SEE PLAN & SCHEDULE) BASE PLATE SET ON 1-1/2" MIN. NON-SHRINK GROUT. 4" DEEP POCKET. FILL w/ GROUT AFTER COL. IS IN PLACE.xxxxxxxxxxxxxxxxxxxxxxxxxxxxSTEEL COLUMN. SEE PLAN AND SCHEDULE. COMPACT CLEAN FILL. TERMITE TREATED. 1/4" (TYP.) BASE PL. 12"x12" x 3/4" THK. w/ (4) 3/4" Ø ANCHOR BOLTS. TYP. x x x x x x x x xxxxxxxx2"2"2"8"8"2"1'-0" 1/4 4" ALTERNATIVE FOR EMBED PLATE DETAIL IN LIEU OF ANCHOR BOLTED PLATExxxxxxxBASE PL. 12"X12" x 3/4" THK W/ (4) 3/4" Ø WELDED HEADED STUDS (9" EMBED) 3'-0" DBL. MESH x x 3'-0" DBL. MESH3'-0" DBL. MESH 3'-0" DBL. MESH 3'-0" DBL. MESH SEE FTG. SCH. (TYP.)SEE FTG.SCH. (TYP.)3" CLR. TYP.3" CLR. TYP.48 BAR ØSCALE: SECTION 3/4"=1'-0" 7 S2.0 ISOLATED FOOTING (SEE PLAN FOR SIZE). CONCRETE SLAB ON 10 MIL POLYETHYLENE VAPOR BARRIER (SEE PLANS FOR SLAB THICKNESS & REINF.). COMPACT CLEAN FILL. CONCRETE COLUMN (SEE PLAN SCHEDULE) x x x x x x x x x x x x x x x x xxx x MONOLITHIC FTG. GOING THRU, NOT SHOWN FOR CLARITY EL: SEE PLAN FIN. FLR. SLAB #4 TRANSFER BAR AT SLAB MID-DEPTH, SEE PLAN SCALE: SECTION 3/4"=1'-0" 4 S2.0 3'-0" DBL. MESH SLOPE, SEE ARCH 8"8"8"8"9"4"(2) #5 TOP (3) #5 BOTT. COMPACT CLEAN FILL. TE-2: 12x16 CONT. THICKENED EDGE. SEE PLAN & SCHEDULE. DRIVEWAY, SEE ARCH GARAGE DOOR SCALE: SECTION 3/4"=1'-0" 8 S2.0 COORDINATE STEPS W/ ARCH. PLANS EL.: SEE PLAN FIN. FLR. SLAB 4"1'-0"MIN.1'-0"MIN.1'-0"MIN.PAVERS ON SAND, SEE ARCH 4"STEP60 BAR ØSEE FTG. SCH. (TYP.)SEE FTG.3" CLR. TYP.3" CLR. TYP. MASONRY COLUMN (SEE PLAN & SCHEDULE) #9 LADDER TYPE JOINT REINFORCING @ 16" o.c. VERTICAL SPACING.SCH. (TYP.)ELEV.: - 1'-4" TO. FTG. (U.N.O.) COMPACT CLEAN FILL. ELEV.: -0'-1.5" T.O.PAVERS CONTINUOUS FOOTING (SEE PLAN FOR SIZE). SAND SET PAVERS, SEE ARCHITECTURAL DRAWINGS.3/4"RECESS3'-0" DBL. MESH 3" CLR. TYP. SEE FTG. SCHD.3" CLR. TYP.SEE FTG. SCHD.8" CMU WALL #9 LADDER TYPE JOINT REINFORCING @ 16" o.c. VERTICAL SPACING. # 6 BAR IN CONC. FILLED CELL @ 40"o.c. (MAX.) COMPACT CLEAN FILL. CONTINUOUS MONOLITHIC FOOTING (SEE PLAN & SCHEDULE) xx x x x xx xx xx x x x ELEV: SEE ARCH. DWGS. CONCRETE SLAB ON GRADE. SEE PLAN AND PLAN NOTES. # 4 x 5'-0" AT SLAB MID-DEPTH. SCALE: SECTION 3/4"=1'-0" 11 S2.0 WINDOW OPENING UP TO 7'-0": 8" x 8" CONC. BEAM SILL w/ (2) #5 BAR CONT. EXTENDED 5" MIN INTO ADJACENT FILLED CELLS. WINDOW OPENING LARGER THAN 7'-0": 8" x12" CONC. BEAM SILL w/ (2) #5 TOP & BOTT. AND #3 @ 8"o.c. STIRRUPS EXTENDED 8" MIN INTO ADJACENT FILL CELLS OR COLUMN. TYP. EL.: SEE PLAN FIN. FLR. SLAB 1'-0"MIN.PAVERS ON SAND, SEE ARCH SHEET NUMBER Distribution This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 07-06-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET KERVIN VENTURA 7522 WILES RD., SUITE B204, CORAL SPRINGS, FL. 33067 UNISONSTRUCTURALDESIGN@GMAIL.COM - TEL.: (305) 298-0467 PERMIT SET: 08-27-2021 FOUNDATION SECTIONS S2.0 1'-6" (MAX.)1'-6" (TYP.)6"(TYP.)12 12 2'-0" (TYP.) FOUNDATION WALL CONTINUOUS WALL FOOTING. (REFER TO PLAN SCHEDULE) TYPICAL FOOTING STEP DETAIL 30" MIN.CORNER PERPENDICULAR 30" MIN. STRIP FOOTING REINFORCING CONTINUOUS THRU PADS CORNER BARS TO MATCH FOOTING REINFORCEMENT TYP. FOOTING CORNER / INTERSECTION DETAIL SCALE: DETAIL 3/4"=1'-0" 5 S2.1 SCALE: DETAIL 3/4"=1'-0" 2 S2.1 SCALE: SECTION 3/4"=1'-0" 3 S2.1 CONSTRUCTION JOINT DETAIL CONTRACTION JOINT DETAIL PREFAB 22 ga. GALV. STEEL FORM TO BE INSTALLED AS PER MANUFACTURER'S SPECS. 1/8" WIDE, 1/4 SLAB DEPTH SAW CUT WITHIN 18 hrs. CUT ALTERNATE WIRE AT CONTROL JOINT FILL SAWCUT WITH NON-SHRINK GROUT WELDED WIRE FABRIC t/2t/2t/2t/2SEEPLAN8" MIN. 3'-0" DBL. MESH (1) #5 CONT. COMPACT CLEAN FILL. EL.: SEE PLAN TOP OF CONC. 8x8 MIN. CONT. THICKENED EDGE. SEE PLAN & SCHEDULE. 3'-0" DBL. MESH SEEPLAN(1) #5 CONT. COMPACT CLEAN FILL. 8x8 MIN. CONT. THICKENED EDGE. SEE PLAN & SCHEDULE. 8" MIN. OPENINGS #5 INGROUTED CELLS EACH SIDE OF OPENING TYP. PRE CAST CONC. LINTEL. w/ (1) #5 SOLID GROUTED MASONRY WALL REINF. NOT SHOWN FOR CLARITY. SEE PLAN (IF REQ'D.) 8" MIN.FINISHED GRADE TYPICAL @ VENT OPENINGS AT FOUNDATON WALLS SEE FIRST FLOOR PLAN FOR LOCATIONS 1'-4"8"1'-0"TO GRADE MAX.CONC. FOOTING, SEE PLAN. SCALE: SECTION 3/4"=1'-0" 7 S2.16"48 BAR DIAMETER.SCALE: SECTION 3/4"=1'-0" 1 S2.1 2 LAYER W.W.F. @STEP x x x x x x x x x x x x x x x x x xxx x x x x x x x x x x x x x x x x x x x x x x xxx x x #9 LADDER TYPE JOINT REINFORCING @ 16" o.c. VERTICAL SPACING. 8" CMU WALL REINFORCING BAR IN CONC. FILLED CELL (SEE PLAN FOR SIZE AND SPACING). CONCRETE SLAB ON 10 MIL POLYETHYLENE VAPOR BARRIER (SEE PLANS FOR SLAB THICKNESS & REINF.). #4 x 5'-0" @ 12"o.c. AT MID DEPTH. (1) #5 CONT. 8" (1) #5 CONT. CONTINUOUS MONOLITHIC FOOTING (SEE PLAN & SCHEDULE) COMPACT CLEAN FILL. EL.: SEE PLAN FIN. FLR. SLAB SCALE: SECTION 3/4"=1'-0" 4 S2.1 SCALE: SECTION N.T.S. 6 S2.1 ATTACHMENT TO UNIT: USE MANUFACTURER FASTENERS OR PROVIDE (2) #12-14 SELF DRILLING SCREWS PER ANGLE CONC. SLAB PER FOUNDATION PLAN MIN. 2'-0" SPACING BETWEEN UNITS (VERIFY W/ MANUFACTURER)6" MIN. OFFSET 6 " M I N .OF F S E T ATTACHMENT TO UNIT: USE MANUFACTURER FASTENERS OR PROVIDE (2) #12-14 SELF DRILLING SCREWS PER ANGLE AND 2-1/4"Ø x 2" LONG TAPCONS INTO CONC.. ANGLE CLIPS TO BE 14 GAUGE MIN. SHEET NUMBER Distribution This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 07-06-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET KERVIN VENTURA 7522 WILES RD., SUITE B204, CORAL SPRINGS, FL. 33067 UNISONSTRUCTURALDESIGN@GMAIL.COM - TEL.: (305) 298-0467 PERMIT SET: 08-27-2021 FOUNDATION DETAILS S2.1 EMBEDMENT LINE SCALE: SECTION 3/4"=1'-0" 1 S3.0 EL.: +13'-6" T.O. BOND BEAM BOND BEAM, SEE PLAN & SCHEDULE 5/8" CDX PLYWOOD ON PRE ENGINEERED WOOD TRUSSES @ 24"o.c.. BOND BEAM, SEE PLAN & SCHEDULE BOND BEAM, SEE PLAN & SCHEDULE SEE ARCH. GIRDER TRUSS EL.: +10'-2" T.O. BOND BEAM SCALE: SECTION 3/4"=1'-0" 4 S3.0 UPLIFT STRAP SEE PLAN 5/8" CDX PLYWOOD ON PRE ENGINEERED WOOD TRUSSES @ 24"o.c. 2"x6" PT SOLID BLOCKING w/ (2) 16d NAILS EA. END AND (3) 0.145"Ø, 1 -1/2" PENETRATION PINS TO CONCRETE SIMPSON HGAM10 CLIP W/ (4) 1/4"Ø 1 x 3/4" TAPCONS AND (4) 1/4"Ø x 1-1/2" SDS SCREWS 2x4 BLOCKING @ 32"o.c. ATTACHED TO BOTTOM CHORD W/ SIMPSON LUS 24 HANGER ATTACH BLOCKING TO WALL. 2x4 BLOCKING @ 32"o.c. SIMPSON LUS24 HANGER W/ (8) 10d TO TRUSS & BLOCKING. BOND BEAM, SEE PLAN & SCHEDULE BOND BEAM, SEE PLAN & SCHEDULE SIMPSON LUS24 HANGER W/ (8) 10d TO TRUSS & BLOCKING. SCALE: DETAIL N.T.S. 2 S3.0 SCALE: DETAIL N.T.S. 3 S3.0 SEE ARCH. DWGS. NOTE: REFER TO ARCHITECTURAL DRAWINGS FOR VENTING. CMU WALL, SEE PLAN. 2x CONT. FASCIA w/ (2) 16d NAILS. 5/8" CDX PLYWOOD ON PRE ENGINEERED WOOD TRUSSES @ 24"o.c.EMBEDMENT LINE SCALE: SECTION 3/4"=1'-0" 5 S3.0 SEE ARCH. DWGS. 5/8" CDX PLYWOOD ON PRE ENGINEERED WOOD TRUSSES @ 24"o.c. SEE ARCH. NOTE: REFER TO ARCHITECTURAL DRAWINGS FOR VENTING. 2x CONT. FASCIA w/ (2) 16d NAILS. DIAPHRAGM BOUNDARY NAILING w/ 10d. RING SHANK NAILS @ 4"o.c. 2x4 MIN. TOP CHORD2x SOLID BLOCKING (SNUG FIT) w/ (2) 12d TOE NAIL EACH END. SEE ARCH. DWGS. FOR REQ'D ROOF VENTING. UPLIFT TIE DOWN . SEE PLAN AND SCHEDULE. 8" CMU WALL SOLID GROUTED 2x4 SOLID BLOCKING w/ (2) 12d NAIL EA. END. # 4 HAIR PIN @ 16"o.c. MIN. (TYP.) 2"x6" PT SOLID BLOCKING w/ (2) 16d NAILS EA. END AND (3) 0.145"Ø, 1 -1/2" PENETRATION PINS TO CONCRETE 2x4 PT x CONT. w/ 1/4"Ø x 3-1/4" LG. TAPCONS @ 16"o.c. UPLIFT STRAP SEE PLAN 5/8" CDX PLYWOOD ON PRE ENGINEERED WOOD TRUSSES @ 24"o.c. 2x CONT. FASCIA w/ (2) 16d NAILS. DIAPHRAGM BOUNDARY NAILING w/ 10d. RING SHANK NAILS @ 4"o.c. SEE ARCH. DWGS. 2x4 PT x CONT. w/ 1/4"Ø x 3-1/4" LG. TAPCONS @ 16"o.c. BOND BEAM. SEE PLAN AND SCHEDULE. 2x4 PT x CONT. w/ 1/4"Ø x 3-1/4" LG. TAPCONS @ 16"o.c.CONC. BEAM. SEE PLAN AND SCHEDULE. 2x6 PT SOLID BLOCKING (SNUG FIT) w/ (1) 12d TOE NAIL EACH END, AND (3) 0.145"Ø PINS TO CONC. 2x6 PT SOLID BLOCKING (SNUG FIT) w/ (1) 12d TOE NAIL EACH END, AND (3) 0.145"Ø PINS TO CONC. 2x SOLID BLOCKING (SNUG FIT) w/ (2) 12d TOE NAIL EACH END. SEE ARCH. DWGS. FOR REQ'D ROOF VENTING. DIAPHRAGM BOUNDARY w/ 10d NAILS @ 4"o.c UPLIFT TIE DOWN (BEYOND) AT EACH TRUSS. SEE PLAN AND SCHEDULE. 5/8" CDX PLYWOOD ON PRE ENGINEERED WOOD TRUSSES @ 24"o.c. SEE ARCH. DIAPHRAGM BOUNDARY NAILING w/ 10d. RING SHANK NAILS @ 4"o.c. 2x SOLID BLOCKING (SNUG FIT) w/ (2) 12d TOE NAIL EACH END. SEE ARCH. DWGS. FOR REQ'D ROOF VENTING. DIAPHRAGM BOUNDARY w/ 10d NAILS @ 4"o.c UPLIFT TIE DOWN (BEYOND) AT EACH TRUSS. SEE PLAN AND SCHEDULE. SHEET NUMBER Distribution This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 07-06-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET KERVIN VENTURA 7522 WILES RD., SUITE B204, CORAL SPRINGS, FL. 33067 UNISONSTRUCTURALDESIGN@GMAIL.COM - TEL.: (305) 298-0467 PERMIT SET: 08-27-2021 ROOF SECTIONS S3.0 TOP OF BOTTOM CHORD MEMBER 6"==2x6 MINIMUM VERTICAL WEB 5" 2 1/2" PL. 1/4" THK. EACH FACE. 1/4"TYP. 2 1/2" PRE ENG. GIRDER. (MINIMUM 3 PLY)6"6"(4) 3/4"Ø THRU BOLTS INTO VERTICAL WEB.2"1/2" PLATE w/ (3) 3/4"Ø x 7" LONG WELDED HEADED STUD2 1/2"7"2 1/2"7 1/2"7"SCALE: DETAIL 3/4"=1'-0" 3 S3.1 COORDINATE WIDTH w/ TRUSS MANUFACTURER 3"4"2"1'-1"3"4"2"1'-1"2-1/2"2-1/2"4"4"GIRDER TRUSS STEEL 1/4" SIDE PLATES w/ (3) 3/4"Ø THRU BOLTS. TYP.1/4" TYP.1/4" STEEL COLUMN. SEE PLAN AND SCHEDULE. H H SECTION H-H STEEL 1/2" CAP PLATE SCALE: SECTION 3/4"=1'-0" 1 S3.1 SCALE: DETAIL 3/4"=1'-0" 2 S3.1COORDINATEWIDTH w/ TRUSSMANUFACTURERTYP.1/4" PLAN NOTE: MINIMUM 2 PLY G.T. 5" 1/4"3"9"2"1/2"PLATE 1/4" WELDED BUCKET w/ (3) 3/4"Ø THRU BOLTS PLATE 1/2" BOTTOM PLATE2"6"COORDINATE WIDTH OF BUCKET W/ FRAMING MEMBER 2"3"3"PRE ENG. GIRDER TRUSS VERIFY BTM. CHORD SIZE TOP OF BOTTOM CHORD MEMBER BOLTS INTO VERTICAL WEB WALL GIRDER w/ MIN. 2"x6" VERTICAL WEB MEMBER(S). AT BRACKET LOCATION TYP.1/4" 1/4" NOTE: MINIMUM 2 PLY G.T. HSS - COLUMN SEE PLAN & SCHEDULE AH UNIT MOUNTING DETAIL TRUSS BOTTOM CHORDPROVIDE 3/4" CDX PLYWOOD SERVICE FLOORING TO SERVICE AHU PLYWOOD BEARS OVER TOP OF BOTTOM CHORDS AND FASTENED w/ 8d's @ 6"o.c. AIR HANDLING UNIT WEIGHT= 400 lbs MAX. UNISTRUT CHANNEL P3000 1/2"1/2" STEEL ANGLE 3x3x1/4 x8" W/ (3) 3/8"Ø THROUGH BOLTS TRUSS BOTTOM CHORD AHU HANGER: 3/8"Ø HEADED RODS AT UNDERSIDE. THREADED END AT TOP, SECURE WITH NUT (WELDED OR OTHERWISE LOCKED TO ROD) 4 TOTAL TO SECURE TO 2 TRUSSES. SCALE: DETAIL 3/4"=1'-0" 4 S3.1SCALE: SECTION 3/4"=1'-0" 4 S3.0 UPLIFT TIE-DOWN, SEE PLAN AND SCHEDULE CONT. 2x12 PT. LEDGER FASTENED w/ 3/4"Ø x 8" LG. SIMPSON TITEN HD SPACED @ 12"o.c. MAX. INTO GROUNT FILL CELL AND AT 6"o.c. FROM ENDS 5/8" CDX EXT. RATED PLYWOOD ON PRE-ENG. WOOD TRUSSES @ 24"o.c. 2x4 PT FASTENED w/ 1/4"Ø x 3-1/4" TAPCONS @ 12"o.c. SHEET NUMBER Distribution This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 07-06-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET KERVIN VENTURA 7522 WILES RD., SUITE B204, CORAL SPRINGS, FL. 33067 UNISONSTRUCTURALDESIGN@GMAIL.COM - TEL.: (305) 298-0467 PERMIT SET: 08-27-2021 TRUSS DETAILS S3.1 TYPICAL DUR-O-WALL DETAILTYPICAL TIE BEAM DROP AT OPENINGS 8" 8"EXTEND DROP OF TIE BEAM 8" BEYOND SIZE OF OPENING AT EACH END OPENING FOR WINDOW, DOOR OR SLIDING DOOR. SEE FLOOR PLAN & ELEVATIONS ADD 2#5 REINFORCEMENT BARS FOR EVERY 12" OF DROP STIRRUPS (REFER TO TIE BEAM SCHEDULE) DROP TIE BEAM @ WINDOW AND DOOR OPENINGS UNLESS NOTED OTHERWISE 9 GAUGE DUR-O-WALL HORIZONTAL REINFORCEMENT EVERY OTHER COURSE (LADDER TYPE) REINFORCED FILLED CELL SEE PLAN FOR SIZE AND SPACING. 9 GAUGE DUR-O-WALL HORIZONTAL REINFORCEMENT EVERY OTHER COURSE (LADDER TYPE) 8"x8"x16" CONCRETE MASONRY UNITS 8"x8"x16" CONCRETE MASONRY UNITS SCALE: DETAIL 3/4"=1'-0" 1 S4.0 SCALE: DETAIL 3/4"=1'-0" 2 S4.0 TIE BEAM ELEVATION CHANGE TIE BEAM. SEE PLAN & SCHEDULE. TIE BEAM. SEE PLAN & SCHEDULE. TIE BEAM REINF. w/ HOOKS. FILLED CELL REINF.SEE PLAN. TIE BEAM REINF. w/ HOOKS. (4) #5 Z-BARS w/ 30" HOOKS. #3 TIES @ 8"o.c. SCALE: DETAIL 3/4"=1'-0" 3 S4.0 14'-0"o.c. (MAX.) DISCONTINUE JOINT REINF. REINFORCED CELL JOINT REINF. ℄ CONTROL JOINT 14'-0"o.c. (MAX.) MASONRY PRIVACY WALL CONTROL JOINT DETAIL. PLAN VIEW SCALE: DETAIL 3/4"=1'-0" 4 S4.0 (2) VERT. BARS 8" CMU2 1/2"TYP.SEE NOTE BELOW. NOTE: REINFORCING INDICATED AS TWO BARS PER CELL SHALL BE POSITIONED EACH FACE USING DUR-O-WAL 'DA816' REBAR POSITIONER OR APPROVED EQUAL. POSITIONER TO BE PLACED AT TOP OF FIRST COURSE EA. FLOOR , BELOW THE LAST COURSE EA. FLOOR AND AT MAXIMUM SPACING OF 200 x BAR DIAMETER (INCHES) DOUBLE REINFORCED MASONRY WALL DETAIL VARIES #9 LADDER TYPE CMU HORIZONTAL JOINT REINF. SHALL EXTEND INTO CONCRETE COLUMN A MINIMUM OF 6" (TYP. AT ALL LOCATIONS) CMU WALL VERTICAL REINF. PER COLUMN SCHEDULE CMU WALL TIES PER COLUMN SCHEDULE LAP SPLICE = 48 BAR DIAMETER CONCRETE COLUMN DETAIL VERTICAL REINFORCING IN GROUT FILLED CELL. SEE PLAN & NOTES. RUNNING BOND MASONRY CONSTRUCTION BLOCK UNITS SHALL TIE ALTERNATELY AT WALL INTERSECTION #9 LADDER REINFORCING AT EVERY OTHER COURSE RUNNING BOND MASONRY CONSTRUCTION BLOCK UNITS SHALL TIE ALTERNATELY AT WALL INTERSECTION SCALE: DETAIL 3/4"=1'-0" 5 S4.0 SCALE: DETAIL 3/4"=1'-0" 6 S4.0 SCALE: DETAIL 3/4"=1'-0" 7 S4.0 SCALE: DETAIL 3/4"=1'-0" 9 S4.0SCALE: SECTION 1/2"=1'-0" 8 S4.0 LAP REINF. WITH WALL ABOVE. (IF WALL ABOVE EXISTS) CONC. TIE BEAM TYP. SEE PLAN FOR REINF. CONC. TIE BEAM / TOP OF FOUNDATION (TYP.) REINF. SEE PLAN. HOOK REINF. INTO FOUNDATION IF NO WALL BELOW. OTHERWISE REINF. FROM WALL BELOW. NOTES: 1.PROVIDE TRUSS TYPE 9 GAGE WIRE HORIZONTAL JOINT REINF. @16"o.c. EVERY OTHER COURSE. 2.PROVIDE MATCHING VERTICAL BAR FOR FULL HEIGHT AT WALL ENDS. 3.ALL CELLS WITH REINFORCEMENT MUST BE GROUTED SOLID. SHEET NUMBER Distribution This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 07-06-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET KERVIN VENTURA 7522 WILES RD., SUITE B204, CORAL SPRINGS, FL. 33067 UNISONSTRUCTURALDESIGN@GMAIL.COM - TEL.: (305) 298-0467 PERMIT SET: 08-27-2021 CMU DETAILS S4.0 MARK 'W' X 'D' SIZE F O O T I N G S C H E D U L E REINFORCING REMARKS TE-1 8" x 12" x CONT.(1) # 5 MID DEPTH F-40 4'-0" x 4'-0" x 14"(6) # 5 TOP & BOTT. EA. WAY F-60 6'-0" x 6'-0" x 16" NOTES: FOOTING INDICATED IN FLOOR PLAN w/ "M" MEANS THAT FOOTING CAN BE POURED MONOLITHICALLY w/ SLAB ON GRADE. TE-2 12" x 16" x CONT.(3) # 5 BOTTOM, (2) # 5 TOP MF-18 (2) # 5 CONT. BOTT., & (2) # 4 CONT. TOP18" x 16" x CONT. (7) # 5 TOP & BOTT. EA. WAY - - - - MF-24 (3) # 5 CONT. BOTT., & (2) # 4 TOP PLUS # 4 @ 12" TRANSV. BOTTOM. - - MF-36 - 20 BAR DIAMETERS TYP. COLUMN REINFORCING DETAIL TERMINATE VERTICAL COLUMN REINFORCING WITH HOOK WHERE APPLICABLE TIE SPACING SEE SCHEDULE SPLICE LENGTH SEE ACI 318 SPLICE LENGTH SEE ACI 318 DOWELS SHALL BE SAME SIZE & NUMBER AS COL. REINF. SEE SCHEDULE VERT. COLUMN REINFORCING SEE SCHEDULE VERT. COLUMN REINFORCING SEE SCHEDULE FOUNDATIONFOUNDATION SLAB SLABSEE PLAN SEE PLAN SEE PLAN SCALE: DETAIL 3/4"=1'-0" 3 S5.0 O T H E R B A R ST O P B A R S LAP LD LT2 CLASS #3 SIZE BAR LD LD LT2 LD LD LT2 LT2 #4 #5 #6 LD LT2 LT2 LD LT2 #8 #9 #7 f'c = 4000 PSI, NORMAL CONC. 1 2 1 2 CATEGORYCATEGORY 18 28 14 21 24 36 18 28 25 37 19 28 32 48 25 37 31 46 24 36 40 60 31 46 37 55 28 43 48 72 37 55 54 81 42 62 70 105 54 81 62 92 47 71 80 120 62 92 69 104 53 80 90 135 69 104 TYPICAL TENSION EMBEDMENT DETAIL CONCRETE FACE OF BAR SIZE 23"16"# 8 # 9 26" 18" # 6 # 7 # 4 # 5 20" 17" 12" 14" 12" TOP 14" BOT 10" 8" f'c = 3000 psi 17"20" 14"12" 15"21"20" 14" 10" 12"17" 14" 16" 13" BOT 7" 9" 10" TOP 13" 9" TOP 12" 9" 11" BOT 6" 8" f'c = 5000 psif'c = 4000 psi 12 BARDIAMETERTENSION EMBEDMENT LAP SPLICE SCHEDULE TENSION EMBEDMENT LENGTH (with std. hook) SCHEDULE SCALE: DETAIL 3/4"=1'-0" 1 S5.0 FASTEN WINDOW or DOOR FRAME w/ TAPCONS THRU FRAME AND PT. BUCK INTO CMU or CONC. IN ACCORDANCE w/ FINAL MANUFACTURERS PRODUCT NOTICE OF ACCEPTANCE. REINFORCED CMU OR CONCRETE POURED JAMB OR HEADER. BED OF CAULKING. FASTEN WINDOW FRAME w/ TAPCONS THRU FRAME AND PT. BUCK INTO CMU OR CONC. IN ACCORDANCE w/ FINAL MANUFACTURERS PRODUCT NOTICE OF ACCEPTANCE. 2 x 4 or 2 x 6 PT. BUCK FASTENED w/ 1/4"Ø x 3-1/4" LG TAPCONS @ 12"o.c. AND 4" FROM CORNERS. VERIFY FASTENERS w/ FINAL PRODUCT NOTICE OF ACCEPTANCE. REINFORCED CMU OR CONCRETE POURED JAMB OR HEADER. 2 x 4 or 2 x 6 PT. BUCK FASTENED w/ 1/4"Ø x 3-1/4" LG TAPCONS @ 12"o.c. AND 4" FROM CORNERS. VERIFY FASTENERS w/ FINAL PRODUCT NOTICE OF ACCEPTANCE. GARAGE DOOR JAMB REINFORCED CMU OR CONCRETE POURED JAMB OR HEADER. GARAGE DOOR 2 x 6 PT. BUCK FASTENED w/ 1/2"Ø EXP. BOLTS @ 12"o.c. AND 4" FROM CORNERS, 5-1/2" EMBED. VERIFY FASTENERS w/ FINAL PRODUCT NOTICE OF ACCEPTANCE. FASTEN DOOR FRAME IN ACCORDANCE w/ FINAL MANUFACTURERS PRODUCT NOTICE OF ACCEPTANCE. WINDOW or DOOR JAMB / HEAD SCALE: TYPICAL BUCK DETAIL 3/4"=1'-0" 2 S5.0 WINDOW SILL GENERAL NOTES: 1. DESIGN CRITERIA: THE FLORIDA BUILDING 2020 7TH EDITION. ASCE 7-16 A. DESIGN LOADS:SUPER IMPOSED ROOF LL 30 PSF DL 25 PSF FIRST FLOOR LL 40 PSF DL 35 PSF GARAGE FLOOR LL 50 PSF BALCONY (UNDER 100sqft) LL 60 PSF DL 30 PSF B. WIND LOADS: ASCE 7-16 BASIC WIND SPEED, V= 170 MPH RISK CATEGORY II EXPOSURE CATEGORY 'D' INTERNAL PRESSURE COEFFICIENT GCpi = ± 0.18 Kd (DIRECTIONAL FACTOR) = 0.85 2. FOUNDATION: a) ALL EARTHWORK SHALL BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OUTLINED IN THE GEOTECHNICAL REPORT. SOIL BEARING CAPACITY = 2500 PSF. b) TOP SOIL AND ALL ORGANIC AND DELETERIOUS MATERIAL SHALL BE COMPLETELY REMOVED AT LEAST FIVE FEET BEYOND THE EXTERIOR OF EACH BUILDING. CLEAN WELL GRADED SAND SHALL BE USED FOR BACK FILL, INSTALLED IN MAXIMUM OF 9" LIFTS. EACH LIFT OF FILL SHALL BE COMPACTED TO 98% OF MODIFIED PROCTOR DENSITY DETERMINED IN ACCORDANCE WITH ASTM D-1557. THE SOIL REPORT WAS PREPARED BY: COMPANY NAME: GFA INTERNATIONAL. ADDRESS: ............. 3902 DUNESIDE DRIVE, FT. PIERCE, FL 34949. REPORT DATE: ..... JANUARY 8, 2014. 3. STRUCTURAL STEEL: a) SHALL CONFORM TO ASTM DESIGNATIONS A-36, A-325, A-500 AS APPLICABLE AND AISC 360-16 SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. BOLTS AND WELDING MATERIALS SHALL CONFORM TO APPLICABLE PROVISIONS OF AISC SPECIFICATIONS, AND AWS RECOMMENDATIONS. b) FIELD CONNECTIONS SHALL BE WELDED OR BOLTED AS SPECIFIED. SHOP WELDING OR WHERE FIELD WELDING IS REQUIRED SHALL BE CERTIFIED WELDERS ONLY. ALL STRUCTURAL STEEL SHALL RECEIVE ONE SHOP COAT OF RUST INHIBITIVE PRIMER PAINT UNLESS NOTED OTHERWISE. c) THE FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW AND ACCEPTANCE PRIOR TO FABRICATION. d) ANCHOR BOLTS SHALL BE SIZED TO PROVIDE A MINIMUM 8" EMBEDMENT INTO FOOTING. e) ALL FIELD WELDS AND SHOP WELDS SHALL BE DONE BY A CERTIFIED AWS WELDER, AS PER FBC. f) STRUCTURAL SHAPES:W - beams . . . . . . . . . . Fy = 50 ksi HSS - rectangle . . . . . . . . Fy = 46 ksi HSS - round . . . . . . . . . . Fy = 42 ksi L - angles . . . . . . . . . Fy = 36 ksi C - channels . . . . . . . Fy = 36 ksi 4. CONCRETE: a) ALL CONCRETE UNLESS OTHERWISE SHOWN: f'c = 3,000 PSI FOR SLAB ON GRADE, FOOTINGS, TIE BEAMS AND TIE COLUMNS. f'c = 4,000 PSI FOR COLUMNS AND WALLS. f'c = 5,000 PSI FOR ELEVATED BEAMS, SLABS AND STAIRS (5 BAG PER YARD MINIMUM, #57 COARSE AGG.) WITH A MAXIMUM 0.40 WATER / CEMENT RATIO. b) SUBMIT MIX DESIGN FOR ACCEPTANCE PRIOR TO CONCRETE PLACEMENT. c) CONCRETE EXPOSED TO WEATHER SHALL HAVE A MAXIMUM 0.40 WATER / CEMENT RATIO, AND ALSO HAVE A CORROSION ADMIXTURE. d) NON-METALLIC, NON-SHRINK GROUT SHALL BE 7,000 PSI COMPLYING WITH CE-CRD-C621. 5. CONCRETE CONSTRUCTION: ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE STANDARD: "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-14). STRENGTH DESIGN METHOD. 6. CONCRETE COVER: a) FOOTINGS AND FOUNDATION PADS PLACED AGAINST THE GROUND 3". b) CONCRETE SURFACE AFTER REMOVAL OF FORMS EXPOSED TO WEATHER OR GROUND: No. 5 OR SMALLER 1-1/2" No. 6 OR LARGER 2" c) CONCRETE NOT EXPOSED TO WEATHER OR GROUND: SLABS AND WALLS 3/4" BEAMS AND GIRDER TIES 1-1/2" COLUMN TIES 1-1/2" 7. REINFORCING STEEL: a) REINFORCING STEEL SHALL BE NEW BILLET BARS CONFORMING TO: ASTM A-615 GRADE 60 (#3 THRU #11) fy = 60000 PSI b) ALL TERMINATING TOP REINFORCING BARS SHALL END WITH A HOOK. 8. DETAILING AND FABRICATION OF REINFORCING: a) UNLESS OTHERWISE NOTED, SHALL FOLLOW ACI-315. b) SUBMIT SHOP DRAWINGS FOR REVIEW AND ACCEPTANCE PRIOR TO FABRICATION. 9. PLACING AND SUPPORTS OF REINFORCING BARS: SHALL FOLLOW CRSI "RECOMMENDED PRACTICE FOR PLACING REINFORCING BARS, INCLUDING 1983 SUPPLEMENT" AND ACI-315. 10. CORNER BARS: PROVIDE #5 x 3'-0" x 3'-0" CORNER BARS AT EXTERIOR CORNERS OF BEAMS AND WALLS. ONE FOR EACH HORIZONTAL LAYER OF REINFORCING 11. WELDED WIRE MESH: A. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 OR A-497 AS APPLICABLE. B. PROVIDE SUPPORTS FOR WELDED WIRE MESH @ 3'-0"o.c. EACH WAY, MAX. 12. CONCRETE MASONRY UNITS: a) THE LOAD BEARING MASONRY WALLS ARE DESIGNED IN ACCORDANCE WITH THE SPECIFICATIONS FOR THE DESIGN AND CONSTRUCTION OF LOAD BEARING CONCRETE MASONRY BY THE NATIONAL CONCRETE MASONRY ASSOCIATION AND BUILDING CODE REQUIREMENTS FOR CONCRETE MASONRY STRUCTURES - ACI 530-14. b) MINIMUM COMPRESSIVE STRENGTH OF LOAD BEARING MASONRY UNITS SHALL BE 1900 PSI (ASTM C90-90, GRADE N) MASONRY CEMENT (MORTAR) SHALL COMPLY WITH ASTM C91 AND SHALL ACHIEVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI (ASTM C270, TYPE M). f'm = 1,500 PSI. c) MASONRY SHALL BE PLACED PRIOR TO PLACING CONCRETE COLUMNS. d) ALTERNATE HORIZONTAL JOISTS SHALL BE REINFORCED WITH #9 GAUGE GALVANIZED LADDER TYPE REINFORCING CONFORMING TO ASTM A82 CONTINUOUS IN ALL 8" CONCRETE MASONRY WALLS. THESE SHALL LAP INTO THE CONCRETE COLUMNS. e) AT ALL WALL ENDS, INTERSECTIONS, CORNERS AND ON EACH SIDE OF WALL OPENINGS, IF A COLUMN IS NOT SHOWN PROVIDE 1 #5 VERTICAL AND GROUT THE REINFORCED CELL OF THE BLOCK. USE DOWELS AND MAINTAIN CONTINUITY WITH THE STRUCTURE ABOVE. TERMINATE BAR WITH A STANDARD HOOK INSIDE THE CONCRETE BEAM AT TOP OF THE WALL. f) PROVIDE CLEAN OUT OPENINGS FOR EACH GROUTED CELL. g) SUBMIT CERTIFICATION OF COMPLIANCE WITH ASTM SPECIFICATIONS FOR THE CMU, MASONRY CEMENT, AND REINFORCING PRIOR TO DELIVERY TO THE SITE. H. ALL LAP SPLICES 48 BAR DIAMETER. i) PROVIDE COURSE GROUT IN ACCORDANCE w/ ASTM C476 f'c = 2500 PSI SLUMP ± 8" 17. OPENINGS IN STRUCTURAL MEMBERS: a) HOLES AND OPENINGS REQUIRED ARE SHOWN ON THESE DRAWINGS. b) NO OTHER OPENINGS OR HOLES IN ANY STRUCTURAL MEMBER ARE PERMITTED WITHOUT WRITTEN AUTHORIZATION OF THE ARCHITECT OR ENGINEER. c) ALL ROUGH OPENINGS AROUND OR AFFECTED BY MECHANICAL, ELECTRICAL, OR PLUMBING EQUIPMENT; OR WINDOWS, DOORS OR OTHER ARCHITECTURAL FEATURES SHALL BE VERIFIED WITH THE ACTUAL PURCHASED ITEM PRIOR TO PROCEEDING WITH THE STRUCTURAL WORK AFFECTED. NOTIFY THE ARCHITECT IF DIMENSIONAL REQUIREMENTS VARY FROM THOSE INDICATED. 19. CURING COMPOUND PROVIDE CURING COMPOUND FOR ALL SLABS " AQUA KURE " BY LAMBERT CORPORATION OR ACCEPTED EQUAL. 20. FORM WORK ALL FORM WORK AND SHORING SHALL BE DESIGNED IN ACCORDANCE WITH ACI 347 (GUIDE TO FORM WORK FOR CONCRETE) THE CONTRACTOR SHALL ENGAGE A PROFESSIONAL ENGINEER EXPERIENCED AT FORM WORK DESIGN TO PREPARE DRAWINGS AND CALCULATIONS FOR SUBMISSION AND APPROVAL BY THE COUNTY PRIOR TO THE PLACEMENT OF CONCRETE. 21. SHOP DRAWINGS: SHOP DRAWINGS SUBMITTED FOR STRUCTURAL REVIEW SHALL CONSIST OF TWO SETS OF PRINTS AND ONE SET OF REPRODUCIBLE. DRAWINGS SHALL BEAR THE CONTRACTORS APPROVAL STAMP ACCEPTING RESPONSIBILITY FOR DIMENSIONS, QUANTITY AND COORDINATION WITH ALL DISCIPLINES. NO CHANGES OR DEVIATIONS FROM THE CONTRACT DOCUMENTS ARE ACCEPTED UNLESS EACH IS CLEARLY IDENTIFIED AS SUCH, AND EACH IS SPECIFICALLY ACCEPTED OR REJECTED. ANY ACCEPTED CHANGE OR DEVIATION FOR REVISION OF THE PERMITTED CONSTRUCTION DOCUMENTS OR VALUE ENGINEERING COST SAVINGS IS SUBJECT TO A REDUCTION OF THE CONTRACT LUMP SUM. ONLY ONE MARKED UP SET WITH THE STRUCTURAL ENGINEERS COMMENTS WILL BE RETURNED TO THE CONTRACTOR. ALLOW TWO WEEKS TIME FOR SHOP DRAWING REVIEW BY UNISON STRUCTURAL DESIGN SHOP DRAWINGS SHALL BE SUBMITTED AT TIME OF PERMITTING. 22. SPECIAL INSPECTIONS: a) SPECIAL INSPECTIONS SHALL BE PROVIDED FOR STEEL FRAMING AS PER SECTION 2218.2 OF THE FLORIDA BUILDING CODE. b) SPECIAL INSPECTIONS SHALL BE PROVIDED VERIFYING THE SOIL COMPACTION AS PER SECTION 1820.3.1 OF THE FLORIDA BUILDING CODE. c) SPECIAL INSPECTIONS SHALL BE PROVIDED FOR THE REINFORCED CONCRETE MASONRY UNITS AS PER SECTION 2122.4 OF THE FLORIDA BUILDING CODE. 13. PRE ENGINEERED WOOD TRUSSES: a) SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION AND THE DESIGN SPECIFICATION FOR METAL PLATE CONNECTED WOOD TRUSSES. b) TRUSSES SHALL BE BRACED DURING ERECTION AND PERMANENTLY IN ACCORDANCE WITH THE TRUSS PLATE INSTITUTES PUBLICATION BRACING WOOD TRUSSES: COMMENTARY AND RECOMMENDATIONS (BWT- 76). c) THE JOIST DESIGN SHALL COMPLY THE FLORIDA BUILDING CODE. d) THE JOIST DESIGNER SHALL SUBMIT COMPUTATIONS AND DRAWINGS INDICATING LAYOUT AND ALL REQUIRED CONNECTIONS, BRIDGING, AND CROSS BRACING BEARING THE SEAL OF A FLORIDA REGISTERED ENGINEER. 14. WOOD CONSTRUCTION: ALL TIMBER CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF "THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION" LATEST EDITION. WOOD COLUMNS AND BEAMS SHALL BE SOUTHERN PINE, NO. 2 GRADE, SURFACE DRY WITH 19% MAXIMUM MOISTURE CONTENT. Fb = 1200 PSI MINIMUM, E = 1,600,00 PSI, Fv = 95 PSI. STUDS AND GENERAL ROUGH CARPENTRY SHALL BE HEM FIR OR SOUTHERN PINE CONSTRUCTION GRADE. Fb = 825 PSI, E = 1,200,000 PSI, Fv = 90 PSI OR APPROVED BY THE ENGINEER IN ADVANCE. CROSS BRIDGING SHALL BE PROVIDED OR APPROVED BY THE ENGINEER IN ADVANCE. CROSS BRIDGING SHALL BE PROVIDED OR APPROVED BY THE ENGINEER IN ADVANCE. CROSS BRIDGING SHALL BE PROVIDED AT 10'-0" o.c. MAXIMUM FOR ALL JOISTS AND RAFTERS MORE THAN 8" IN DEPTH USE 2" X 3" OR AN APPROVED BRIDGING. 2 x SOLID BLOCKING SHALL BE PLACED BETWEEN JOISTS OR RAFTERS AT ALL SUPPORTS. PLYWOOD SHALL BE EXTERIOR TYPE WITH EXTERIOR GLUE (CDX) DFPA TRADEMARK STAMPED AND CONFORMING TO PS-1-83. ALL STRUCTURAL LUMBER AND FASTENINGS SHALL CONFORM TO THE "NATIONAL DESIGN SPECIFICATION FOR STRESS-GRADE LUMBER CUT AND ITS FABRICATION". FOLLOW MINIMUM RECOMMENDED FASTENING SCHEDULE, FLORIDA BUILDING CODE UNLESS OTHERWISE NOTED ON THE PLAN. WORKMANSHIP SHALL BE FIRST CLASS IN ALL RESPECTS AND MEET THE REQUIREMENTS OF A STANDARD GOOD PRACTICE NORMAL TO THE TRADE. PLYWOOD MAY BE NAILED WITH THE USE OF AIR POWERED GUNS EXCEPT WHERE NOTED OR SHOWN OTHERWISE. THE NAIL SHALL BE DRIVEN BUT IN NO CASE SHALL THE DRIVING OF THE NAILS BREAK OR SPLIT THE FACE PLY OF THE PLYWOOD SHEET. PLYWOOD SHEETS WITH BROKEN OR SPLIT FACES SHALL BE REMOVED AND NEW SHEETS PLACED AS DIRECTED, ALL AT THE EXPENSE OF THE CONTRACTOR. LIGHT GAUGE STRUCTURAL CONNECTORS SPECIFIED ON THE DRAWINGS ARE AS SHOWN ON DRAWINGS. EQUIVALENT APPROVED CONNECTORS WITH IDENTICAL DIMENSIONS WHERE NECESSARY AND EQUAL OR GREATER LOAD CAPACITIES ARE ACCEPTABLE AS ALTERNATES. 15. DIMENSIONED LUMBER, HEAVY TIMBER, & ROUGH CARPENTRY: a) SHALL COMPLY WITH THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION. fb =1200 PSI MINIMUM. SOUTHERN PINE #2 b) FOR MINIMUM NAILING REQUIREMENTS NOT SPECIFIED ON DRAWINGS, REFER TO F.B.C. FASTENING SCHEDULE AND HIGH VELOCITY HURRICANE ZONE FOR APPLICABLE INCREASES. c) ALL FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE STAINLESS STEEL. 16. PLYWOOD: a) SHALL COMPLY WITH THE PLYWOOD DESIGN SPECIFICATION BY THE AMERICAN PLYWOOD ASSOCIATION. b) PLYWOOD SHEATHING SHALL BE 5/8", APA RATED SHEATHING, EXTERIOR, 48/24 PANEL IDENTIFICATION. UNLESS NOTED OTHERWISE. c) PROVIDE BLOCKING AT ALL PLYWOOD PANEL JOINTS. INSPECTION PLANS a. SPECIAL INSPECTOR STATEMENT OF INTENT AND INSPECTION PLAN FOR REINFORCED UNIT MASONRY INSPECTION. STRUCTURAL ENGINEER SHALL INSPECT THE ENTIRE “REINFORCED UNIT MASONRY” SYSTEM FOR THIS BUILDING, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1.MASONRY UNITS, MORTAR, GROUT AND REINFORCING STEEL MEET SPECIFICATIONS. 2.DOWELS PROPERLY PLACED, WITH ADEQUATE LAPPING. 3.STEEL AND COLUMNS TIES IN COLUMNS, PILASTERS, AND BEAM ELEVATION TRANSITIONS PROPERLY PLACED, LAPPED AND TIED. 4.MASONRY FIELD WORK: HEAD AND BED JOINTS, HORIZONTAL JOINT REINFORCING INSTALLED CORRECTLY, CELLS FREE OF EXCESSIVE MORTAR FINS, WALLS LEVEL AND PLUMB WITHIN TOLERANCES. 5.VERIFY GROUT SLUMP, PROPER CONSOLIDATION OF GROUT, AND PROPER LOW OR HIGH-LIFT GROUTING PROCEDURES WERE FOLLOWED. 6.CORRECT EMBEDMENT OF REINFORCING STEEL, BOLT, TIES, ETC. 7.COMPLIANCE WITH ACI 530/ASCE 5 AND COMMENTARIES; THE APPROVED PLANS AND FBC 2122, R4407.5. 8.VERIFY SPOT SURVEY AND ELEVATION CERTIFICATE HAVE BEEN APPROVED BY THE CITY OF FORT LAUDERDALE, PRIOR TO TIE BEAM INSPECTIONS. 9.INSPECTION REPORT LOGS WILL BE MAINTAINED AT JOB SITE FOR STEEL INSPECTIONS. 10. CITY INSPECTIONS: CONTRACTOR SHALL CALL FOR FOUNDATION, SLAB, COLUMN AND BEAM INSPECTIONS. SPOT SURVEY MUST BE APPROVED BY THE CITY OF FORT LAUDERDALE PRIOR TO PLACING TIE BEAM CONCRETE. THIS INSPECTION PLAN TO BE FOLLOWED UP BY AN INSPECTION CERTIFICATE FOR REINFORCED UNIT MASONRY THAT ATTESTS TO THE ABOVE, WHICH SHOULD BE SUBMITTED TO THE BUILDING INSPECTOR AT THE TRUSS INSPECTION AND MUST BE SUBMITTED PRIOR TO THE FRAMING INSPECTION. b. SPECIAL INSPECTOR STATEMENT OF INTENT AND INSPECTION PLAN FOR STRUCTURAL STEEL AND CONNECTION INSPECTION. STRUCTURAL ENGINEER SHALL INSPECT THE ENTIRE “STRUCTURAL STEEL AND CONNECTIONS” SYSTEM FOR THIS BUILDING, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1.INSPECT STRUCTURAL STEEL PRIOR TO CONCEALMENT TO VERIFY GRADE, SIZES, CONNECTIONS, STRAIGHTNESS AND FINISH. CHECK WITH CONTRACT DOCUMENTS AND REVIEWED SHOP DRAWINGS. 2.INSPECT SETTING OF ANCHOR BOLTS, EMBEDS AND OTHER MISCELLANEOUS STRUCTURAL ITEMS PRIOR TO CONCRETING. VERIFY SIZE, QUANTITY AND FINISH. 3.INSPECT CONNECTIONS FOR THE FOLLOWING: 3.1. BOLTED CONNECTIONS: TYPE, SIZE AND NUMBER OF BOLTS. CHECK THAT BOLTS ARE CLEAN & LUBRICATED AND HAVE PROPER WASHERS AND THAT THEY CONFORM TO THE SPECIFICATIONS. 3.2. WELDED CONNECTIONS: VISUAL EXAMINATION OF ALL FIELD WELDS. VERIFY THAT WELDERS ARE AWS CERTIFIED. VERIFY THAT WELDS ARE CLEAN, FREE FROM SLAG AND RUST PROTECTION HAS BEEN APPLIED AS PER SPECIFICATIONS. THIS INSPECTION PLAN TO BE FOLLOWED UP BY AN INSPECTION CERTIFICATE FOR REINFORCED UNIT MASONRY THAT ATTESTS TO THE ABOVE, WHICH SHOULD BE SUBMITTED TO THE BUILDING INSPECTOR AT THE TRUSS INSPECTION AND MUST BE SUBMITTED PRIOR TO THE FRAMING INSPECTION. SEE ADD'L SECTIONS & DETAILS FOR BASE & CAP PLATE's INFO. COLUMN SYMBOLS # # # # # COLUMN BELOW COLUMN CONTINUOUS COLUMN ABOVE COLUMN ABOVE COLUMN BELOW TYPEMARK 'W' x 'D' SIZE C O L U M N S C H E D U L E REINFORCING VERTICAL SPACING TIE REMARKS 1 STEEL CONC. HSS 4" x 4" x 3/8"10 1. THE SCHEDULED SIZES ARE MINIMUM STRUCTURAL SIZES FOR REINFORCING STEEL FABRICATION ADDITIONAL CONCRETE MAY BE REQUIRED FOR ARCHITECTURAL PURPOSES OR TO REACH WINDOW OR DOOR JAMB. ALL OVERALL COLUMN SIZES SHALL BE VERIFIED WITH ARCHITECTURAL PLANS PRIOR TO FORMING. BASE PLATE 12"x12"x3/4" w/ (4) 3/4"Ø ANCHOR BOLTS. (1) # 3 @ 8"o.c. COLUMN SCHEDULE NOTES: (4) # 6 - "D""W"1 8 x 18 MC-1 CMU 12 x 12 (1) # 3 @ 8"o.c.(4) # 6 - 1'-0"1'-0"114"112"112"MC-1 - 24" x 16" x CONT. 36" x 16" x CONT.(4) # 5 CONT. BOTT., & (3) # 4 TOP PLUS # 4 @ 12" TRANSV. BOTTOM. 2 CONC. (1) # 3 @ 8"o.c.(4) # 6 -8 x 24 2 STANDARD HOOK SHEET NUMBER Distribution This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 07-06-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET KERVIN VENTURA 7522 WILES RD., SUITE B204, CORAL SPRINGS, FL. 33067 UNISONSTRUCTURALDESIGN@GMAIL.COM - TEL.: (305) 298-0467 PERMIT SET: 08-27-2021 COLUMNS SCHEDULE S5.0 8" MIN. BEARING TYP.D 19"W 1" CLR.2" COVERS3/3S2/3 S3/3S1/3 S1/3 S2/3 S3 MIN. *24D S1 C STANDARD 90HOOKD A G S2 2" FOR FIRST TIE MIN. *30D 2" COVERCANTILEVER2" COVER18"o.c.(MAX.)18"o.c.(MAX.)18"o.c.(MAX.)2" FOR FIRST TIE DOUBLE LAYER BOTTOM BAR PLACING DIAGRAM TOP BARS BTM. BARS BTM. BARS A CONCRETE BEAM BAR PLACING DIAGRAM E D A E F G B GREATER SPAN GREATER SPAN ADDITIONAL (2) #5 BARS BTM. BARS ADDITIONAL (2) #5 BARS DEEP BEAM ADDITIONAL REINF. BARS DESIGNATED "G" ARE TOP CONTINUOUS THRU SPAN WITH 90 DEG. STANDARD HOOK AT DISCONTINUED END. LAP SPLICE "G" BARS ONLY, AS NECESSARY AND WITHIN CENTER THIRD OF SPAN (30 DIAMETER) "E" BARS ARE OVER RIGHT SUPPORT AS MEMBER IS READ FROM LEFT TO RIGHT. "A" BARS (BOTTOM) ARE CONTINUOUS. * SEE REINFORCING LAP SPLICING SCHEDULE. BEAM SCHEDULE NOTES: 1.THE TOP ELEVATIONS AND DEPTHS INDICATED IN THIS SCHEDULE ARE FOR DETERMINATION OF THE STRUCTURAL ELEVATIONS AND DEPTHS OF BEAMS. ADDITIONAL CONCRETE MAY BE REQUIRED TO REACH TOP OF SLAB ELEVATIONS OR BOTTOM OF BEAM ELEVATIONS REQUIRED FOR ARCHITECTURAL REASONS. ALL BEAM BOTTOM ELEVATIONS SHOULD BE VERIFIED WITH THE ARCHITECTURAL DRAWINGS PRIOR TO FORMING. IF THE REQUIRED RISE EXCEEDS 8", ADD .3) #5 AT 12"o.c. HORIZONTAL IF THE REQUIRED DROP EXCEEDS 6", ADD .3) #4 AT 12"o.c. HORIZONTAL AND #3 STIRRUPS @ 12"o.c. VERTICAL. 2.ARCHED BEAM PROFILE SEE ARCHITECTURAL DRAWINGS. SEE STRUCTURAL DETAIL FOR ADDITIONAL REINFORCING. 3.BEAM DECORATIVE PROFILE SEE ARCHITECTURAL DRAWINGS 4.FOR BEAMS EQUAL OR DEEPER THAN 19" DEEP, SEE "DEEP BEAM ADDITIONAL REINFORCING" DETAIL ABOVE. 5.FOR TIE BEAMS AT CORNERS, INTERSECTIONS, AND BENDS PROVIDE (4) #3 STIRRUPS AT 12"o.c. B E A M S C H E D U L E #3 (UNLESS NOTED OTHERWISE) MARK REINFOR.NOTE-1 WIDTH 'B' ELEVATION NOTE-1 'A''D' DEPTH BOTTOMSIZE 'G''C' & 'E'SPACING STIRRUPS REMARKS REINFORCING TOP 2B-1 _ 2B-2 2B-3 8 20+ 9'-4"_(2) # 7 BOT (2) #6 (2) #5 REINFORCING PROVIDE 8" MINIMUM BEARING AT EACH SIDE OF OPENING WIDTH 7'-0" TO 12'-0"16"(2) #5 CLEAR SPAN FT. 3'-0" TO 7'-0" DEPTH 12"(2) #5 TOP #3 @ 6"o.c. TIES #3 @ 5"o.c. (MIN.) CAST IN PLACED REINFORCED CONCRETE LINTEL SCHEDULE MID REINFORCING PROVIDE 8" MINIMUM BEARING AT EACH SIDE OF OPENING WIDTH 8" OR 12" 4'-1" TO 7'-6"16"(2) #5 CLEAR SPAN FT. UP TO 4'-0" DEPTH 8" TOP(MIN.) PRE CAST LINTEL SCHEDULE 24"7'-7" TO 12'-0" BOTT. (2) #5 (2) #5 (2) #6(2) #5(2) #5 SCALE: DETAIL 3/4"=1'-0" 2 S5.1 TYPICAL TIE BEAM DROP AT OPENINGS 8" 8"EXTEND DROP OF TIE BEAM 8" BEYOND SIZE OF OPENING AT EACH END OPENING FOR WINDOW, DOOR OR SLIDING DOOR. SEE FLOOR PLAN & ELEVATIONS ADD 2#5 REINFORCEMENT BARS FOR EVERY 12" OF DROP STIRRUPS (REFER TO TIE BEAM SCHEDULE) DROP TIE BEAM @ WINDOW AND DOOR OPENINGS UNLESS NOTED OTHERWISE SCALE: DETAIL 3/4"=1'-0" 3 S5.1 8" OR 12" 8" OR 12" 8" OR 12" 8" OR 12" (2) #812'-0" TO 16'-0"20"(2) #7 #3 @ 6"o.c.8" OR 12" (2) #816'-0" TO 20'-0"24"(2) #7 #3 @ 8"o.c.8" OR 12" TYPICAL TIE BEAM OR BOND BEAM. SEE PLAN & SCHEDULE FOR REINF BLOCK COURSES OVER PRECAST LINTEL W/ #4 @32"o.c. ALTERNATIVE: GC MAY ELECT TO POUR THIS BEAM FULL HEIGHT WITHOUT AN INTERMEDIATE BLOCK LAYER OR PRECAST LINTEL. PROVIDE (2) #5 TOP AND BOTTOM AND (1) INTERMEDIATE HORIZONTAL LAYER OF (2) #5 MUST BE PROVIDED PER EVERY 16" OF CONCRETE DEPTH. #3 TIES @12"o.c. MUST BE PROVIDED FULL HEIGHT. PRE CAST LINTEL SEE SCHEDULE BELOW TYP. PRE CAST LINTEL ('PCL') OVER OPENINGS 8" MIN. BEARING TYP. TIE BEAM DROP OVER OPENINGS TYP. TIE BEAM REINF. W/ (2) #5 TOP AND BOTT., STIRRUPS(4) #3 @12"o.c. EA. END AND BALANCE @48"o.c. ADDITIONAL (2) #5 @16"o.c. MAX.VERTICAL SPACED, ONE EACH FACE (2) #5 BOTTOM STIRRUPS #3 @12"o.c. SEE PLAN SCALE: DETAIL 3/4"=1'-0" 1 S5.1 # 6 DOWELS w/ STD. HOOKS LAP 30" SEE ARCH B.O. LINTEL OPENING KNOCK-OUTBLOCK COURSEPRE CAST LINTEL w/ (1) # 6 CONCRETE COLUMN PROVIDE 2" BEARING _ _ (2) # 7 (4) @ 4"o.c. EA. END, BAL. @ 8" o.c. TIE BEAM ELEVATION CHANGE TIE BEAM. SEE PLAN & SCHEDULE. TIE BEAM. SEE PLAN & SCHEDULE. TIE BEAM REINF. w/ HOOKS. FILLED CELL REINF.SEE PLAN. TIE BEAM REINF. w/ HOOKS. (4) #5 Z-BARS w/ 30" HOOKS. #3 TIES @ 8"o.c. SCALE: DETAIL 3/4"=1'-0" 6 S5.1 SCALE: PLAN DETAIL 3/4"=1'-0" 5 S5.1 NOTE: PROVIDE CORNER BARS FOR BEAMS AND WALLS TO MAINTAIN CONTINUITY. CORNER BARS @ CORNERSCORNER BARS @ INTERSECTION (1) #5 x 3'-0" x 3'-0" CORNER BAR AT EACH LAYER OF REINFORCING, EXTERIOR FACE. (1) #5 x 3'-0" x 3'-0" CORNER BAR AT EACH LAYER OF REINFORCING, EACH FACE. BB- BOND BEAM @ CORNER REINFORCEMENT LAYOUT.BB-(1) #6 x 3'-6" x 3'-6" CORNER BAR, TOP AND BTM. (2 TOTAL). BB- BOND BEAM @ INTERSECTION REINFORCEMENT LAYOUT.BB-(1) #6 x 3'-6" x 3'-6" CORNER BAR, TOP AND BTM., ALTERNATE DIRECTION. (2 TOTAL). BB- BOND BEAM ELEVATION CHANGE BOND BEAM. SEE PLAN & SCHEDULE. BOND BEAM. SEE PLAN & SCHEDULE. BOND BEAM REINF. BOND BEAM REINF. (1) #5 w/ 30" HOOK TYPICAL. (1) #5 w/ 30" HOOK TYPICAL. FILLED CELL REINF., SEE PLAN. OPENINGOPENING 2LB-1 8 16 12 8 16 16 (3) # 6 (3) # 6_ _ _ _ 2BB-1 8 16 (2) # 5 EACH COURSE _ _ _ 2BB-2 + 13'-3" 2BB-3 8 24+ 10'-2"(2) # 5 EACH COURSE _2BB-4 8 16 (2) # 5 EACH COURSE+ 13'-3" BOND BEAM SEE SCHEDULESEE SCHEDULE REFER TO ARCH. DWGS. PRE CAST LINTEL LINTEL BEAM SEE SCHEDULE BB REFER TO ARCH. DWGS. PRE CAST LINTEL IF APPLICABLE SEE SCHEDULE REFER TO ARCH. DWGS. PRE CAST LINTEL 2BB-22'-4"ADD'L. # 4 @ 16"o.c. TO VERT. REINF. (2) # 5 EACH COURSE (2) # 5 EACH COURSE1628 + 9'-4" + 9'-4" + 9'-4" + 9'-4" (2) # 7 (2) # 7 SEE SCHEDULE REFER TO ARCH. DWGS. PRE CAST LINTEL 8x8 w/ (2) # 6 BOTTOM. 2LB-1 # 4 @ 16" o.c. ADDIT'L. TO VERT. REINF. SHOWN IN PLAN. (2) # 5 BOND BEAM & LINTEL ADD'L. # 4 @ 16"o.c. REINF. 2B-4 8 10 __+ 8'-6"(2) # 5 (2) # 5 (4) @ 4"o.c. EA. END, BAL. @ 8" o.c. @ 5"o.c. EA. END. (4) @ 4"o.c. EA. END, BAL. @ 8" o.c. SHEET NUMBER Distribution This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 07-06-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET KERVIN VENTURA 7522 WILES RD., SUITE B204, CORAL SPRINGS, FL. 33067 UNISONSTRUCTURALDESIGN@GMAIL.COM - TEL.: (305) 298-0467 PERMIT SET: 08-27-2021 BEAM SCHEDULE AND DETAILS S5.1 C:\Users\USD400\Documents\Sylvia Backup 09.03.19\Projects\GMK\210068 - 3902 Duneside\Struct\S5.0_3902 Duneside.dwg, 8/30/2021 10:03:25 AM 20'-0" (MAX.)± 45°8'-0" (MAX.)8'-0" (MAX.)8'-0" (MAX.)8'-0" (MAX.)2"4" COORDINATE WIDTH w/ TRUSS SUPPLIER. 4"4" 4" MIN.9"COORDINATE WIDTH w/ TRUSS SUPPLIER. 4"COORDINATEw/ TRUSS SHOP DRAWINGS.2"9"9" MIN.9"9"9"COORDINATEw/ TRUSS SHOP DRAWINGS.1 1 2 "4" 4" 1 1 2 "234"112" PLYWOOD EDGE w/ 10d RING SHANK NAILS @ 6"o.c. 2"x4" BLOCKING AT ALL PLYWOOD EDGES TYPICAL. TRUSSES @ 24"o.c. DIAPHRAGM BOUNDARY w/ 10d RING SHANK NAILS @ 4"o.c. DIAPHRAGM BOUNDARY w/ 10d RING SHANK NAILS @ 4"o.c DIAPHRAGM BOUNDARY w/ 10d RING SHANK NAILS @ 4"o.c 2"x4" BLOCKING. SEE DETAIL "B" PLYWOOD EDGE w/ 10d RING SHANK NAILS @ 6"o.c. 5/8" PLYWOOD SHEATHING INTERMEDIATE SUPPORT w/ 10d RING SHANK NAILS @ 6"o.c. 2"x4" BLOCKING AT ALL PLYWOOD EDGES TYPICAL. SEE DETAIL "B". DIAPHRAGM BOUNDARY w/ 10d RING SHANK NAILS @ 4"o.cINTERMEDIATE SUPPORT w/ 10d RING SHANK NAILS @ 6"o.c. ALL PLYWOOD EDGES w/ 10d RING SHANK NAILS @ 6"o.c. SCALE: DETAIL - PLAN 3/4"=1'-0" 6 S6.0 TYP. 2x4 CONTINUOUS LATERAL BRACE 24" o.c. (OVERLAP @ SPLICES) TYP. BOTTOM CHORD BRACING SCALE: DETAIL N.T.S. 8 S6.0 NOTE: BOTTOM CHORD LATERAL BRACE SPACED 8'-0" (MAX.) , LOCATED AT OR NEAR A PANEL POINT. 2x4 CONT. BOTTOM CHORD LATERAL BRACE @ 8'-0"o.c. MAX. w/ (2) 16d NAILS, EA. TRUSS. TRUSS BOTTOM CHORD NOTE: DIAGONALS FROM BRACED BAY. REPEAT AT ENDS AND AT APPROXIMATELY 20'-0" INTERVALS. 24" OVERLAP 24" OVERLAP (2) 16d NAILS EACH MEMBER 2x4 DIAGONALS BOTTOM CHORD LATERAL BRACE @ 20'-0" INTERVALS w/ (2) 16d NAILS, EA. TRUSS. SCALE: SECTION 3/4"=1'-0" 7 S6.0 TYP. 2"x4" CROSS BRACING @ 20'-0" MAX. 2x4 CONT. LATERAL WOOD BRACING NAILED TO BOTTOM CHORD MAXIMUM 8'-0"o.c. SPACING AND AS REQUIRED BY TRUSS MANUFACTURER PRE-FAB WOOD ENGINEERED 2x4 ON FLAT CROSS-BRACING TO BRACE TRUSS WEB AT INTERVAL NOT EXCEEDING 20'-0".BRACE AT 45 ANGLE (2) 16d NAILS EACH MEMBER SCALE: DETAIL N.T.S. 5 S6.0 23 3 1 2 2 1 1 10d @ 4" O.C. 10d @ 4" O.C. 10d @ 4" O.C. 10d @ 6" O.C. NAILING SCHEDULE CORNER NAILING BOUNDRY NAILING EDGE NAILING INTERMEDIATE NAILING 4 2 3 1 PROVIDE 1/8" SPACING AT PANEL EDGES APA 40/20 19/32" EXPOSURE 1 PLYWOOD SHEATHING PRE-ENG. WOOD TRUSSES @ 24" O/C (SEE ROOF PLAN) PROVIDE 2x4 BLOCKING @ ALL PLYWOOD SEAMS BETWEEN 1ST (6) TRUSSES OR 12 FT NAIL SEAM w/ 10d @ 4"o.c. EACH SIDE OF SEAM WOOD FASCIA (SEE TYP. WALL SECTION) w/ (2) 16d TO EACH TRUSS END BOND BEAM OR TIE BEAM (SEE TYP. WALL SECTION) LATERAL BRACING IF REQUIRED (SEE TYP. WALL SECTION) 1/16" SPACE AT PANEL ENDS ALL NAILS SHALL BE RING SHANK NAILS SCALE: DETAIL 3/4"=1'-0" 1 S6.0 UPLIFT SCHEDULE 2 BOLTS 9,200 lbs UPLIFT CAPACITY 11/16" Ø HOLES 1/4" THK. A36 STEEL 1/4" THK. A36 STEEL 7-1/2" WIDE 3/4"Ø SIMPSON TITEN HD 5-1/2" EMBED. SEE PLAN & SCHEDULE FOR QUANTITY OF BOLTS. CONCRETE COLUMN, CONCRETE BEAM OR REINFORCED CMU. 4 BOLTS 14,260 lbs 1/4" 1/4" PL. 1/4" thk. EA. FACE w/ (3) 3/4"Ø THRU BOLTS 6 BOLTS 18,600 lbs NUMBER OF 3/4"Ø BOLTS DETAIL "B" TRUSSES @ 24"o.c. DETAIL "A" PLAN PLAN DESIGNATION NET UPLIFT (kips) (1.0 k = 1,000 lbs) UPLIFT TIE-DOWN UPLIFT TIE-DOWN SCHEDULE AT EXISTING CONCRETE BEARING CONDITION FOR HIGHER UPLIFT CAPACITY. SEE CUSTOM WELDED BUCKET DETAILS HIGHER NOTES: 1.REFER TO "SIMPSON" STRONG-TIE PRODUCT INFORMATION, CATALOGUE FOR INSTALLATION SPECIFICATIONS. 2.FOR HIGHER CAPACITY, SEE PLAN FOR DESIGNATED SECTION / DETAIL MARKING FOR SPECIFIED CONNECTION. 3. A34 CLIPS SHALL BE FASTEN TO CONCRETE w/ (3) 3/16"Ø x 1" LG. TAPCONS, MIN. 1" SPACING. "SIMPSON" COMBINATION *A34 (LATERAL ONLY) PLUS SINGLE HTSM16 w/ (4)1 4"Ø x 21 4" TITEN TO CONCRETE AND (8)10d x 3" TO TRUSS. (FULL UPLIFT) UNITY EQUATION STRAP CAPACITY = 1175 lbs APPROVAL No. FL10446.3 FL1423.11 "SIMPSON" COMBINATION *A34 (LATERAL ONLY) PLUS MGT w/ (1) 5 8"Ø ATR - 12" EMBED INTO CONCRETE AND (22) 10d x 3" TO GIRDER. (FULL UPLIFT) UNITY EQUATION STRAP CAPACITY = 3965 lbs APPROVAL No. FL10446.3 FL1423.15 "SIMPSON" COMBINATION *A34 (LATERAL ONLY) PLUS DOUBLE HTSM16 w/ (8) 14"Ø x 2-14" TITEN TO CONCRETE AND (16)10d x 3" TO TRUSS (FULL UPLIFT) UNITY EQUATION STRAP CAPACITY = 2350 lbs No. FL10446.3 FL1423.11 "SIMPSON" COMBINATION *A34 (LATERAL ONLY) PLUS HGT w/ (2) 3 4"Ø ATR - 12" EMBED INTO CONCRETE AND (16) 10d x 3" TO GIRDER (FULL UPLIFT) UNITY EQUATION STRAP CAPACITY = 10,980 lbs APPROVAL No. FL10446.3 FL10866.10 10.9 11.0 * 3.9 2.4 4.0 2.3 1.2 1.1 0.1 NOTES: 1.REFER TO "SIMPSON" STRUCTURAL CONNECTORS PRODUCT INFORMATION, CATALOGUE FOR INSTALLATION SPECIFICATIONS 2.FOR HIGHER CAPACITY, SEE PLAN FOR DESIGNATED SECTION / DETAIL MARKING FOR SPECIFIED CONNECTION. PLAN DESIGNATION NET UPLIFT (kips) (1.0 k = 1,000 lbs) "SIMPSON" SINGLE STRAP. HETAL20 w/ (14) 10d x 1-12" EMBEDDED STRAP. UNITY EQUATION CAPACITY = 1152 lbs APPROVAL No. FL11473 UPLIFT TIE-DOWN "SIMPSON" DOUBLE STRAP. HETAL20 w/ (14) 10d x 1-12"PLUS HETA20 w/ (9) 10d x 1-12" EMBEDDED STRAP. UNITY EQUATION CAPACITY = 2962 lbs APPROVAL No. FL11473 "SIMPSON" COMBINATION HETAL20 w/ (14) 10d x 1-12" (LATERAL ONLY) PLUS MGT w/ (1) 5/8"Ø ATR - 12" EMBED INTO CONCRETE AND (22) 10d x 3" TO GIRDER UNITY EQUATION STRAP CAPACITY = 3965 lbs . (2 PLY MINIMUM) APPROVAL No. FL11473 FL11470 "SIMPSON" COMBINATION HETAL20 w/ (14) 10d x 1-12" (LATERAL ONLY) PLUS HGT-3 w/ (2) 3 4"Ø ATR - 12" EMBED INTO CONCRETE AND (16) 10d x 3" TO GIRDER (FULL UPLIFT) UNITY EQUATION STRAP CAPACITY = 9035 lbs (3 PLY MINIMUM) APPROVAL No. FL11473 FL10456 FL10866 FOR HIGHER UPLIFT CAPACITY. SEE CUSTOM WELDED BUCKET DETAILS UPLIFT TIE-DOWN SCHEDULE AT CONCRETE BEARING CONDITION (WET POUR) HIGHER 9.3 9.0 4.0 3.9 3.0 2.9 1.2 1.1 0.1 SIMPSON HUS210 HANGER w/ (30) 16d x 3" TO HEADER AND (10) 16d x 3" TO JOIST (2,845 lbs MAX.) APPROVAL No. FL10655 SIMPSON HUS26 HANGER w/ (14) 16d x 3" TO HEADER AND (10) 16d x 3" TO JOIST (1,550 lbs MAX.) APPROVAL No. FL10655 SIMPSON LUS26 HANGER w/ (8) 10d x 1-12" (930 lbs MAX.) APPROVAL No. FL10655 ATTACHED TO GROUTED CMU SIMPSON MBHA HANGER w/ (2) 3/4"Ø ATR- 8" EMBED TO CMU AND (18) 10d x 3" TO JOIST (3,145 lbs MAX.) APPROVAL No. FL10866 PLAN DESIGNATION NET UPLIFT (kips) (1.0 k = 1,000 lbs) UPLIFT TIE-DOWN UPLIFT TIE-DOWN SCHEDULE AT WOOD LEDGER BEARING CONDITION NOTES: 1.REFER TO "SIMPSON" STRONG-TIE PRODUCT INFORMATION, CATALOGUE FOR INSTALLATION SPECIFICATIONS 2.FOR HIGHER CAPACITY, SEE PLAN FOR DESIGNATED SECTION / DETAIL MARKING FOR SPECIFIED CONNECTION. 3.3" MIN. WIDTH (DOUBLE PLY) WOOD LEDGER. SINGLE PLY WOOD LEDGER - 1/2 THE SPECIFIED CAPACITY. - 3.1 2.9 2.8 1.6 1.5 1.0 0.9 0.1 SIMPSON H10 CLIP W/ (18) 10d x 1-12" (990 lbs MAX.) APPROVAL No. FL10456 (2) SIMPSON H10 CLIP w (36) 10 x 1-12". (1,980 lbs MAX.) OR (2) SIMPSON HTS20 STRAP w/ (48) 10d x 1-12". (2,900 lbs MAX.) APPROVAL No. FL10456 (1) SIMPSON HTS20 STRAP w/ (24) 10d x 1-12" (1,450 lbs MAX.). APPROVAL No. FL10456 OR (2) SIMPSON H10 CLIP w/ (36) 10 x 1-12". (1,980 lbs MAX.) PLAN DESIGNATION NET UPLIFT (kips) (1.0 k = 1,000 lbs) UPLIFT TIE-DOWN - UPLIFT TIE-DOWN SCHEDULE AT WOOD BEAM BEARING CONDITION NOTES: 1.REFER TO "SIMPSON" STRONG-TIE PRODUCT INFORMATION, CATALOGUE FOR INSTALLATION SPECIFICATIONS 2.FOR HIGHER CAPACITY, SEE PLAN FOR DESIGNATED SECTION / DETAIL MARKING FOR SPECIFIED CONNECTION. - - 2.9 1.5 1.4 0.9 0.8 0.1 A4 B4 C4 - - A3 B3 C3 - D3 A1 B1 C1 D1 A2 B2 C2 D2 5/8" CDX PLYWOOD ON PRE-ENGINEERED WOOD TRUSSES SCALE: SECTION DETAIL 3/4"=1'-0" 2 S6.0 2x SOLID BLOCKING w/ (2) 12d TOE NAILS EACH END UPLIFT TIE-DOWN. SEE PLAN & SCHEDULE 5/8" CDX PLYWOOD ON PRE ENGINEERED WOOD TRUSSES @ 24"o.c. SEE ARCH EMBEDMENT LINE 2x CONT. FASCIA w/ (2) 16d NAILS. DIAPHRAGM BOUNDARY NAILING w/ 10d. RING SHANK NAILS @ 4"o.c. SEE ARCH. DWGS. CMU WALL, SEE PLAN. UPLIFT STRAP SEE PLAN 5/8" CDX PLYWOOD ON PRE ENGINEERED WOOD TRUSSES @ 24"o.c. 2"x8" SOLID BLOCKING w/ (2) 16d NAILS EA. ENDS 5/8" CDX PLYWOOD ON PRE ENGINEERED WOOD TRUSSES @ 24"o.c. SIMPSON HGAM10 CLIP W/ (4) 1/4"Ø 1 x 3/4" TAPCONS AND (4) 1/4"Ø x 1-1/2" SDS SCREWS 2x4 BLOCKING @ 32"o.c. ATTACHED TO BOTTOM CHORD W/ SIMPSON LUS 24 HANGER ATTACH BLOCKING TO WALL. 2x4 BLOCKING @ 32"o.c. SIMPSON LUS24 HANGER W/ (8) 10d TO TRUSS & BLOCKING.BOND BEAM, SEE PLAN & SCHEDULE BOND BEAM, SEE PLAN & SCHEDULE SIMPSON LUS24 HANGER W/ (8) 10d TO TRUSS & BLOCKING. SCALE: DETAIL N.T.S. 3 S6.0 SCALE: DETAIL N.T.S. 4 S6.0 BOND BEAM. SEE PLAN AND SCHEDULE 2x6 PT SOLID BLOCKING (SNUG FIT) w/ (1) 12d TOE NAIL EACH END, AND (3) 0.145"Ø PINS TO CONC. 2x4 PT x CONT. w/ 1/4"Ø x 3-1/4" LONG TAPCONS @ 16"o.c. SHEET NUMBER Distribution This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 07-06-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET KERVIN VENTURA 7522 WILES RD., SUITE B204, CORAL SPRINGS, FL. 33067 UNISONSTRUCTURALDESIGN@GMAIL.COM - TEL.: (305) 298-0467 PERMIT SET: 08-27-2021 ROOF DETAIL S6.0 R O O F U P L I F T D I A G R A M + 34.2 - 61.4 - 54.4 + 23.4 - 45.1 + 29.5 + 18.7 - 38.1 AREA (A) Kd = .85 V= 170 MPH EXPOSURE "D" RISK CATEGORY: II INTERNAL PRESSURE COEFFICIENT = ± 0.18 PRESSURES INDICATED IN THIS TABLE ARE CALCULATED SERVICE PRESSURES (0.6W) IN ACCORDANCE WITH ASCE 7-16 USE THIS TABLES FOR PRODUCTS WITH NOA ≤ 19 sqft ZONE 20 sqft < A ≤ 49 sqft 50 sqft < A ≤ 99 sqft 100 sqft < A 3ZONE 2e12r a = 5.1' 2H - 98.1 - + 9.6 3H - 120.9 + 9.6 + 9.6 - + 9.6 + 9.6 + 9.6 - - - 92.8 ZONE ZONE ZONEZONE - 91.0 - 75.7 - 63.9 - 54.9 - 108.0 + 34.2 + 23.4 + 29.5 + 18.7 + 34.2 + 23.4 + 29.5 + 18.7 + 34.2 + 23.4 + 29.5 + 18.7 - 84.7 - 75.7 - 63.9 - 54.9 - 84.7 - 75.7 - 63.9 - 54.9 - 84.7 - 102.1 R O O F U P L I F T D I A G R A M 3 3 3 3 3 33 3 3 3 3 3H 3H 3H 3H 3H 3H 3H 3H 3H 3H 2e 2e 2e 2e 2e 2H 2H 3H2H 2H 2e 2e2H 2H 2H 2H 2H 2e 2H 2H 2e 2r 2r 1 2r 1 2e 2r 2e a = 5.1'(TYP.)a = 5.1' (TYP.) a = 5.1' (TYP.)a = 5.1'(TYP.)WALL & WINDOW PRESSURE DIAGRAM 5 5 5 5 5 5 5 4 4 4 4 4 4 4 55 5 4 4 54 5 a = 5.1'(TYP.)a = 5.1' (TYP.) ZONE #5ZONE #4 20 sqft < A ≤ 49 sqft 50 sqft < A ≤ 99 sqft AREA (A) 100 sqft < A WALL ELEVATION ZONES DIAGRAM Kd = .85 FULL BLDG. HEIGHTUNLESS NOTED OTHERWISE≤ 19 sqft W A L L & W I N D O W P R E S S U R E S C H E D U L E PRESSURES INDICATED IN THIS TABLE ARE CALCULATED SERVICE PRESSURES (0.6W) IN ACCORDANCE WITH ASCE 7-16 V= 170 MPH EXPOSURE "D" RISK CATEGORY: II INTERNAL PRESSURE COEFFICIENT = ± 0.18 USE THIS TABLES FOR PRODUCTS WITH NOA ZONE 4 ZONE 5ZONE 5 - 49.8 - 47.7 - 45.0 - 42.9 + 43.8 + 45.9 + 41.1 + 39.0 a = 5.1'a = 5.1' a = 5.1' - 61.4 - 57.3 - 51.8 - 47.7 + 43.8 + 45.9 + 41.1 + 39.0 SHEET NUMBER Distribution This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 07-06-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET KERVIN VENTURA 7522 WILES RD., SUITE B204, CORAL SPRINGS, FL. 33067 UNISONSTRUCTURALDESIGN@GMAIL.COM - TEL.: (305) 298-0467 PERMIT SET: 08-27-2021 WIND PRESSURE S6.1 + 43.8 - 47.7 + 41.1 - 51.8 + 41.1 - 45.0 + 45.9 - 49.8 + 43.8 - 47.7 + 45.9 - 49.8 + 43.8 - 47.7 + 43.8 - 47.7 + 45.9 - 49.8 + 45.9 - 49.8 + 43.8 - 57.3 + 41.1 - 45.0 + 43.8 - 47.7 + 45.9 - 61.4 + 45.9 - 61.4 + 45.9 - 61.4 + 45.9 - 49.8 + 45.9 - 61.4 + 45.9 - 49.8 + 45.9 - 61.4 SHEET NUMBER Distribution This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 07-06-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET KERVIN VENTURA 7522 WILES RD., SUITE B204, CORAL SPRINGS, FL. 33067 UNISONSTRUCTURALDESIGN@GMAIL.COM - TEL.: (305) 298-0467 PERMIT SET: 08-27-2021 SCALE: FRONT ELEVATION 3/16" = 1'-0" 1 S7.0 SCALE: REAR ELEVATION 3/16" = 1'-0" 3 S7.0 SCALE: LEFT SIDE ELEVATION 3/16" = 1'-0" 4 S7.0 SCALE: RIGHT SIDE ELEVATION 3/16" = 1'-0" 2 S7.0 ELEVATIONS WIND PRESSURE S7.0