In-Place Density Test Report
Client:D. R. Horton America's Builder UES Technician:Nakia Sutton
6123 Lyons Road
Coconut Creek, FL 33073
Date Tested:11/30/2021
Project:CMT CREEKSIDE
Yorktown Drive & Okeechobee Road,Fort Pierce, St Lucie County, FL
Type of Test:
Area Tested:Lot 19 - 9617 Potomac Dr, Fort Pierce Field:ASTM D-6938 Nuclear Gauge Method
Material:Fill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 North side 109.0 11.7 103.2 10.2 95 Pass
2 South side 109.0 11.7 103.4 10.8 95 Pass
3 East side 109.0 11.7 103.6 10.4 95 Pass
4 West side 109.0 11.7 103.8 10.6 95 Pass
Remarks:Tests performed along outside perimeter of structure.
Permit # 2105-0879
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Alex Albandoz, P.E.
STATE OF FLORIDA
Professional Engineer No. 92555
This item has been digitally signed and sealed by Alex Albandoz,
P.E. on the date adjacent to the seal. Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.