Loading...
HomeMy WebLinkAboutPermit Info Sheet �. LLI-cLL -� ST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code-Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required I Roof System i the Permit Application See List Below Form Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 2,4,5,6,7 Asphaltic Shingles A,B,D 1�2,4,5,6,7 -- Concrete or Clay Tile A,B,D,E 1,2,3,4,5A7 Metal Roofs A,8,D t,2,3,4,51617 Wood Shingles and A,B,D 1,2,4,5,6,7 Shakes Other As Applicable JA3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable). 1. Fire Directory Listing Page 2 From Product Approval: Front Page Specific System DeScnption Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128 4 Other Component of Product Approval 5 Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) -7 Any Required Roof Testing/Calculation Documentation I Form Rooflnfofeb2l Rev Feb 18,2021 ST. LUCIE WORKS Section A (General Information) Master Permit No Process No Contractors Name Collins Roofing Inc, License 0 CCC-058011 4215 Garrison Join Address Ldl1� " ROOF CATEGORY V.-Slope chanicafly Fastened Tile ❑Mortar/Adhesive Set Tiles ❑Asphaltic Shingles 1; eta$Panel/Shingles OWood Shrngkes/Shakes 0 Prescriptive BUR-RAS 15G ROOF ROOF TYPE 0 New roof ❑ Repair ❑ Maintenance VReroofing ❑Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) 360 4 Steep Sloped Roof Area(SF) 2500 Total(SF) 2860 Section 8(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. I I I I I i i p i � I S !s LUCIE WORKS ORKS White Granular Surfaces Section C (Low Slope Roof) Surfacing Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment manufacturer Zone 1':—"oc @ Lap,#Rows—®—oc (if a component is not used,identify as"NA") Zone 1!—" oc @ Lap, ff Rows—.._ —"oc System Manufacturer. Polyglass Zone 2:— oc @Lap,#Rows—�—`ac Product Approval No: FL 1654 R27 Zone 3:—" oc @ Lap, lit Rows—®—oo Number of Fasteners Per Insulation Board. Design Wind Pressures,From RAS 128 Or Calculations Zone 1' Zone 1: Zone 2: Zone 3: 53 -53.3 -74 4 -95.8 Zone]' one L Zone 2 _Zone 3: Illustrate Components Noted and Details as Applicable- Max. Design Pressure,from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping, system: Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing,Coping, Etc. Deck. Type Plywood Indicate Mean Roof Height, Parapet Height, Height of Base ; Flashing,Component Material,Material'Thickness,Fastener Gauge Thickness 5/8 Type,Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. Slope: 1-112 1 1Z Anchor/Base Sheet&No.df Ply(s) h Anchor/Base Sheet Fastener/bonding Material: FT._ Insulation Base Layer Base Insuitation Size and Thickness: Parapet Base Insulation Fastener/Bonding Material. Height Top Insulation Layer: Top insulation Size and Thickness: 8 FT. Top Insulation Fastener/Bonding Material: Mean Base Sheet Polyglass SA-V& 1s}&No.of Piy(s) — Roof Base Sheet Fastener/Bonding Material: Height Sell-Adhesive {. Ply Sheet(s)'&No of Piy(s): E Ply Sheet Fastener/Bonding Material k i II Top Ply- TORCH APPLIED - POLYGLASS i I Top Ply Fastener/Bonding Mwer4 SELF ADHESIVE TORCH APPLIED ST. LUCIE WORKS Section D(Steep Slope Roof System) Extreme Metal Fab Roof System Manufacturer Notice of Acceptance Number. FL 17023 Mimmum Design Wind Pressures,If Applicable(From RAS 127 or Calculations) 817 Zone 139—Zone 2e.31ELZone 2n7.4.5—Zone 2r7-4 S-7one 3e Zone 3r. Deck Type: 51B" Plywood ment Temh Type Undedayment= Hi (Self Adhesive Underla i RoofSiope: � 9 p Y MULE HIDE SHUR � 4 _ 12 GUARD_ Insulation: NIA Fire Barrier. N/A Ridge Ver-Adation? Fastener Type &Spacing; I#104.5"-12"x12" Pattern 16" o c (Wood Zac) NIA Adhesive Type: NIA _I Type Cap Shee t NIA ��Rocf Height. 15 ft Roof Covering: 26 Ga 5V Metal Roof Panels Type&Size Drip 2"x2" Galy. Steel Edge: