HomeMy WebLinkAboutOC DURATION ver 2020 .�
Business i Professional Regulation
L III Illy
DOS Home Log In User Reglstratlon HotToplcs Submit Surcharge Stabs&Facts Publications contact Us BCIS Site Map Links Search
F!Orda
Product Approval r 4
USER:Public User
PrQduct AQproydl Menu>2MgUq or Agollr_at€on Search Applicat9on List>Application Detail
FL# FL10674-R16
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Owens Coming
Address/Phone/Emall One Owens Corning Parkway
Toledo,CH 43659
(740)404-7829
g reg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeIer@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscarnig.com
Quality Assurance Representative
Address/Phone/Email
Category Roof mg
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professionaf Engineer
Evaluation Report-Hardcopy Recelved
Florlda Engineer or Architect Name who developed the Robert J.M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 01/01/2099
Validated By John W. Knezevich, PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R16 COI 2020 01 9 iVIEMINEN ,Lf
Referenced Standard and Year(of Standard) Standard Y r
ASTM D1970 2015
ASTM D3161 2016
ASTM D3462 2010
ASTM❑7158 2019
Equivalence of Product Standards
Certified By
Sections from the Code
Prodvd Approval Method Method 1 Option D
Date Submitted 12/11/2020
Data Validated 12/17/2020
Date Pending FBC ApPmval IZ/26/2020
Date Approved 02/09/2021
rlmpaa
of worse ts
Nodal,Numaer or Name Ilesurlpdon Owans Coming Psphalt Rooflng 3-tab,4-tab,laminated,starter and hip a ridge shingles
Shingles aM SWrtets
Use Installation Instrua]6.
tl for use In HVXZ:No FFL1067A R16 Il 2n2012 11 FINALER a ASPHALTd for user eutsltle XVHZ:VesResistant: N/A VerlFled By: Robert 1.M.Nleminen PE-59166
Pressure: N/A Created by Independent Third Parry:Yes
efer to ER,Section 5. Evaluation Reports
FL 0674 R16 A 2020 1 1 N R D PHALT
SHIN$HIN FSI�FL10UAA16 odf
Created Vy Independent Third Party:Yes
6a[k O
la-4e7-111d4
TM SOW of nmlaa is an W set mpi e[,4q T Ored anent::�tv�r"t`m-4nt:: E9fMe
under Flome law,a and addresses are pudlC records.[f you do not want your a-mail address released In response to a mails records mount,do not semi eiectronic
mail to Mk army.means,[on[M Me orm 1,lemon to by tndltbral mall.Hyou have any questions,please cmteR 850.451.1395. INrsuanp la hwd.r 0.553J5(1),
s,aReNve Cohen¢,1,2012,Il Randy emma u:n¢ees devoted under Cha ds,455,E5.must pmyhsu tM Oeramos n,with an amall address rNay have One.The emelle
prodded conymusetlt wIXflalnl WmmnsWuswwkh Me 0n made.Nowevxo the
pudrezxz a huhXcyoudocotnder oyapter 5peRamLWarts.P4aze
pmvlde the Capertment wish an snail addeefi¢wM[n cm be made available to Ne puEllc To de[¢eml�a dYru art a II¢n¢ee under gaptt,455,F.S.,Dlease dlckpas
sauce 4ppwvalfttepY:
Credit Card
Safe
NEMO l etc.
Certifilcate of Authorization#32455
353 Christian Street,Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
Owens Corning Evaluation Report 037940.02.12-1131
One Owens Corning Parkway FL30674-R36
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7929 Revision 11: 12/11/2020
SCOPE:
This Evaluation Report is issued under Rule 61G2D-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Cade. The product described herein has been evaluated for
compliance with the 7th Edition(2020)Florida Building Code sections noted herein.
DESOIipTIow Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review Of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION:Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by: on,
Robert J.M.Nieminen,P.E. Thehalk lm .l.ppeanng.s..1u,nmaglnoeen
1 s"G,,,f ' Nkminen,e.e On 12/11/1120.rundoesnnsemasan
Florida Registration No.59166 Florida DCA ANE19a3 ".{ "..... ekdranlulN signed do ent
QRTFIGTMM or INDEPENDENCE:
1. NEW ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being Issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building rotle evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,In anyway,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02010 NEMO ETC,LLC
ii
WNEMO j etc.
ROOFING SYSTEMS EVALUATION:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the 7ih Edition (2020) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Sectlon Prooerri iSgD9ird Year
1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015
1507.2.5,R905.2.4 Material standard ASTM 1)3462 2010
1507.2.7.1,11905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2019
3. REFERENCES:
En!hy, Examination Reference Date
Owens Corning Declaration Equivalency Declaration 08/06/2019
PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/207
UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA2020 04/18/2006
UL LLC(TST9628) Wind Resistance IICA34308 02/18/2012
UL LLC(TSf9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC 0 ST9628) Physical Properties Classification letter 10/02/2015
PRI(QUA9110) Quality Control Service Confirmation 04/05/2020
PRI(QUA9110) Quality Control Florida BCIS Current
DESCRIPTION:4. PRODUCT
TABU 1:AWMLTSHINGLE COMPONENTS
Type Product Plant(s) Material Description
Standard
Startef strip Shingle H-TX,OR
Accessory Starter Strip Plus MN,OR ASTM 13412 starter strips for asphalt of shingles
Starter SRS TORShleld Starter MN,OR
Strips Starter Shingle Roll NH ASTM D1970 mineral-surfaced,fiberglass-reinforced,
self-adhering SES modified bitumen starter
Supreme' GA,CA,CO,I-TX,W,OH, ASTM D3462 fiberglass reinforced 3-tab asphalt
TN,OR,It roof shingles
Berkshire' MN ASTM D3462 fiberglass reinforced,4-tab asphalt
roof shingles
Duration Premium CA,OR
Asphalt Duratlon'Premium COOL CA
Shingles TruDefinition'Duration' IN,CA,CO, -TX,F4 NJ,OH,
Tm Designer
ionrCollelod MN,OR,GA,IL,TN fiberglass reinforced,laminated
Oesignee Color Collection ASTM D3462 asphalt roof shingles
Oakridge' GA,IN,L, CO,R-TX, -TX,
F4 NI OH,TN
Tru=n,biori Otnd e' H-TX,I-TX
WeatherGuard'HP TN
NEMO ETC,LLC Evaluation Report 0 EnN10.OZ.12-R33
certiAraNgnuMwhmion x32455 7-EDITION(Z020)Pat NON-HVHZ EVALUATION FL10674-R16
Owens Coming Aspheft Roof Shingles Revision 11:12/11/3020
page 2 of 10
TABLE 1:ASPWSLT SHINGLE COMPONENTS WNEMOletc.
Type Product Plant(s) Material DescriptionStandard
Berkshire'Hip and Ridge MN
Shingles with Sealant
Hipand DuraRidge°Hip and Ridge MN fiberglass reinforced,hi
Ridge Shingles with Sealant ASTM D3462 r6 pand ridge
Shingles PmEdge- GA,CA,OH,OR asphalt roof shingles
WeatherGuard'HP Hip and TN
Ridge Shingles
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5_5 Wind Classification:Referto Section 6for installation requirementsto meetwind classifications
TABLE 2A:WIND CLASSIFICATIONS,ASPHALT SHINGLES
Product FBC Table 1507.2.7.1 or R905.2.6.1
Supreme
Berkshire'
Duration'Premium
Duration Premium COOL
TruDefinition'Duration ASTM D3161(F)&ASTM D7158(H)
TmDefinition'Duration'Designer Color Collection
Oakddge'
T.Definitlon'Oakridge'
WeatherGuam'HP
5.5.1 Classification by ASTM D710:
ASTM D7158,Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
Ni UC,LM Evaluation Report 037940.02.12-R11
Gotd Of Authonaaona321.35 7TM EOmON(20201 FBC NOWHVHZ EVALUATION FL30674-R16
Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020
Page 3 of 10
ONEM01I
TABIS 28:WIND CLASSIFICATIONS,STARTERSTRIPSAND HIP&RIME
TYPe Product FBC Table 1507.2.7.1 or R905.2.6.1
Starter Strip Shingle
Starter Strips Starter Strip Plus ASTM D3161,Class
SRS TopShield Starter
Berkshire'Hip and Ridge Shingles with Sealant
Hip&Ridge Duragidge•Hip and Ridge Shingles with Sealant
Shingk, PmEdge° ASTM D3161,Class
WeatherGuard'HP Hip and Ridge Shingles
5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations.
5k All components in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Page 1 of this Evaluation Report.
6.1 GENERAL:
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2A or R905.2.3.
6.1.3 Fasteners shall be In accordance with the shingle manufacturers published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6.2 Access0gn,STARTERS:
6.2.1 Installation of Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter shall comply with the Owens
Corning current published instructions,using minimum five(5)nails per strip.
FiwtleYymanr 0M Wwedraw+ -we 6,Iaawae
Dft
w.a4xrtw'
axurma
0ep adsa atr aNww
„a
r•—r man.,.. t._,.ti«..aw
frsa So,
sft� adcesim BivlrgaAmre
IVai=dala .... IaNRe6Wxp6rNs (eL'lbxdabp,aw
an:Mrw�'
d�nevM Snrlx Sob ah6Nk overhanpa.aysa,Mnkes,.�- surnsrovra..in+w.a,.w,aax lu-are'
Figure 1:Minimum Nailing,Starter Strip Figure 2:Minimum Nailing,Starter Strip Plus
NEMO ETC,LLC Evaluation Repon 03794O.M.17 R11
Cen,ftPore ofAurhomoven A32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10674 R16
Owens corning Asphaft Roof Shingles Rewion 11:12/31/2020
Page 4 of 10
ONEMOletc.
6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
Dad
Drip edge Underlayment
Drip edge
Starter Shingle Roll adhered
direclly to underlaymeM and
primed dnp edge
Self-sealing adhesive
positoned along eaves
Figure 3:Starter Shingle Roll
6.3 ASPHM.TSHINGLES:
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions:
➢ Berkshire'shingles require minimum five(5)nails per shingle.
➢ WeatherOuard'HP shingles require minimum six(6)nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Supreme:
Normal Minunund Araepare Na I Mnn d A.par
Wind Arctic High Mind tleeve aY Wind Araea High Wind de.—
Areapar.whh"n.J. Arwa vlenma/ucrtaa A.Pnn,vfineup nn hin Areee win./aorta
+" fAl s t z• Ip x Y� r IN Y f' r Iel t'
+* tt tt
S Exposure sEurEe"—
Ewpvn.— Expo thin
Figure 4:Minimum Nailing,Supreme Figure 5:Minimum Nailing,Supreme
(Standard Size) (Metric Size)
NEMO ETC,LLC E.I..Bpn Report 032a.0.0Z.12-Fill
Gaud eAurhorecmn a32455 ]TM EDMON(2020)Fa[NON-HVHZ EVALUATION 1`1.10614R%
Owem coming Asphah Roof Shingles; Revision 11:12/11/20M
Page 5of 10
ONEMIDIetc.
6.3.1.2 Berkshire-:
seaee 9nv s.,Lnv nav
wheaaeM�m 11.m,a.,draaa,
t• Aw 9Vf' 9V(' eyf
Figure 6: S.Nail Pattern,Berkshire Figure 2: 6-Nail Pattern,Berkshire
SeahM ship
W:ha W Mh&b,
Y' I.
a�
�' nspnarc rwrny amrem
N.am Ale[kae rmb
Figure B: Mansard or Steep Slope Pattern,Berkshire
NEMO ETC,LEE Evaluation Report O31900.0Z.12-1111
Certifimfa oJAuthonzatmn#32455 pa EDITION(2020)FBC NON-HVHZ EVALUATION FL10674-R36
Owens Corning Asphalt Roof Shingles Revision 11:1ZI11/2020
Page 6 of 30
6.3.1.3 Duration- Premium TrvDefinitlon° Duration ONEMOjetc.Durations Premium COOL&TruDeFlnition Duration' Designer Col
Collection:
4-Nall Fastening Pattern
Nsl.ltpbal
H —� I iR t
sm, ee.s
sIarR
Figure 9:Standard 4-Nail Pattern,Duration
6-Nall Fastening Pattern
sumN iwta5l !WaMawm
Has,Twom
r ' it
_i_�_eef>ua Wwaif' � — tiao�®4 _ ♦iae[vsfaw,w�
Figure 10: ENail Pattern,Duration
Fastening For Slopea Greater Than 21:12
6u1Bxawufhs mine a—.
xep.Typl.
1^ 1x^ � 1Y 1^
6.141. y9^
F1 �;La
x.
Four 11 1p u,ofpsplielt RooN,p Cement
Figure 11: Mansard or Steep Slope Pattern,Duration
NEMO ETC,LLC Evaluation Report 037M.02.12•R31
Cettfiwreo/pulM1oruatbn#32455 Tm EDITION(2020)FBC NON-HVHZ EVALUATION F110671R16
OwensW Ing Asphalt Root Shingles Revision 11:12/11/20M
Page 7 of 10
ONEMOletC.
6.3.1.4 TruOefin t on Oakridge° Oakridee°:
4 Ndl Palm 6 Not Phone
Es4uema coop Haws E,,ma ron 6 dews
6gffE,ow. gags 55%'EBPasure� Naps 55°%Exp95un
F+Panviu+Ae56/BPW9 CYws Evpos(cbnes rr%PW8 F av'newas
h35/BPulg. Cbra EvpoYCNnb56/BPWB.
Figure 1L Standard 4-Nail Pattern,Oakritlge Figure 23:&Nall Pattern,Oakddge
F.Welry for Slope°G.A.Than 21:12
auYY69 rew"N"" ena
Ree,NWaa
1Y 12•
6N° S�as�
•�2"
rw,1"epoY IX IapeeN RwaM Gmenl
Figure 14:Mansard or Steep-Slope Pattern,OaUdge
6.3.1.5 WeatherGuard°HP:
6 Net Ieme tie,We
Fa¢ can 6 davaa W 6)Ar ITIran,honnm
of Shnille
Clore a81t$roAo.M le
55ta'fap4a¢a Farever" pale iMeia ah leja
&podd6n de 5 5�G pig.
t�52pdg tall,��— —NJ ip WL
Ll
Four 1 Sp.e o5 Aspraa Pool Came.
556e'EVrcva s5a'E (;tWrO punts de BemRrm de redo de arfat6 dB l pugeda
Egpa5M4e6sepop Gooaali sS�wq
Figure 15:5-Nail Pattern,W eadeerGuard HP Figure 1&Mansard or Steepolope Pattern,WeatherGuard HP
NEMO ETC,LLC Evaluation Report 037940.0L12-a11
EertfhNotedAuthorlBarbn#32455 ]r"EDITION(20203 HIC NON-HVHZ EVALUATION 0.10624-936
Owens Corning Mohair Roof Shingles Revision 11:12/11/2020
Page a of 10
ONEMOjetc.
6.4 Hip AND RIME SHINGIES:
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
➢ Berkshire'Hip and Ridge Shingles with Sealant and DuraRidgeg Hip and Ridge Shingles with Sealant require
minimum two(2)nails per shingle.
➢ WeatherGuard'HP Hip and Ridge Shingles and PrOEdge4 require minimum four(4)nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.4.1.1 Berkshire-Hip and Ridge with Sealant and D Rid eg Hip and Ridge Shingles ith Sealant.
Fig. A Fig. B
Prevailing wick Direction Top View
� Direction dei vienlo predominance t. Vista superior t
Nail
2W' cl—
Nells�y.. °�� • orwmearWq sveuw.
LYmoa --
\
° I
yam�'.-r'r'D,Itl9n--aaii N L
EaNiuonlelpld I
I II a I�
I
......__ __.... � 12'
Figure 12:Isometric Vlew,Berkshire and DuraRidge Figure IS:Plan View,Berkshire and Duralkidge
6.4.1.2 WeatherGuard•Hp HIP and Ridge Shingles-
Fig.A 44 Fig.C Hip S Ridge Shingle Fastening
ProwlbawM � F
~—alttclbn A To 4Yw
44
\Y 'o NOW Wlb
A �
./� A l l i I p I•
I
+ h 1
S' )
Expoauro
a' ®eowro
12,
Figure 19:Isometric View,WeatherGuard HP Hip and Ridge Figure 20:Plan View,WeatherGuard HP Hip and Ridge
NEMO ETC,LLC Evaluation Report 03790.02.1I-1111
os(ssw ofAuthwaatbng32Q Pa EDITION(2020)FIRE NON-HVHI EVALUATION FUD670-1136
awens Coming Asphalt Roof Shingles Revision 11:12/11/20M
Page 9 of 10
*NEMO etc.
6.4.1.3 ProEdgee:
Prevailing Standard _—[P
Wind Direction _ Feateniag .{
A- ` g'Exposure
Petlam N r
Ut 8aawnt
Faten1'1 {� Is EyoRt
town,Lips," Il
FMtmen with
Real CemsM
Figure 21:Isometric View,PmEdge Figure 22: Plan View,PonEdge
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contactthe named OA entity formanufacturtngfactlittes Covered by FAG Rule 616Z(1-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALITY
PRI Construction Materials Technologies,LLC—QUA9110; 813 621-5777;bw'IsonCaloricmtcom
- END OF EVALUATION REPORT-
MEMO ETC,LLC Evaluation Report 031940.01.12-031
cewgwte alautM1wlmrbn M240 7e EDITION 12020)FEE NON-WtlHZ EVALUATION FL10614416