Loading...
HomeMy WebLinkAboutOC TRI BUILT ver2020 BusinessaProfessional Regulation BCIS Home Log In user Reglstration Hot Topics Submit Surcharge Stats&Facts Publications contact us @CIS Site Map j Links Search ba Product Approval r 4USER:Public User rryductAflpmu Menu>Product or Agkgotion Search a 6ppEicati9nL1st>AppllcaUon betall FL# FL34539 Application Type New Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Beacon Sales Acquisitions,Inc.c/o Owens Coming Roofing and Asphalt LLC Address/Phone/Email 1 Owens Corning Parkway Toledo,OH 43657 (740) 587-3562 greg.keeIer0owenscorning.com Authorized Signature Greg Keeler g reg,keeler*owe nscorning.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect blame who developed the Zachary R. Priest Evaluation Report Florida license PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration pate 12/31/2024 Validated By Steven M. llrich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL34539 RO COI OCR2000.1 2020 FBC Eval TRI-BUILT Granular rLdf Referenced Standard and Year(of Standard) Standard Year_ ASTM ❑ 1970 2015 ASTM D 226 2009 Equivalence of Product Standards Certified By Sections From the Cade Product Approval Method Method 1 Option D Date Submitted 10/14/2020 Data Validated 10/15/2020 Date Pending FBC Approval 10/25/2020 Date Approved 12/16/2020 9u..am of Products M. Model,Number or Name Descefptlon 34539.1 TM-BUILT Granular Underlayny nt A seN-adh..d undedayment used as an s ternaltve to A lei D 226,Type 11 roofing felt. Limits of Use Installation Instroctlona Approved for use in FMNI:No Approved for use outside NVN2:Yes Granular.pdt Impact Resistant: N/A Verified By: Zachary R.Priest PE-74021 Design Pressure:N(A Created by Independent Third Party:Yes Other: See evaluation report for IImRs of use. Evaluation Reports F 46 9 RO AE OCR20001 2020 FBC Ev I TRI-BUILT arle_41ill Created by Independent Third Party:Yes Back peat Un[ac[Ilz;: ,y M ^E`en=�3]393 Pnane:B50 71B]O The SWt¢af F4Ma18M NJEEn grykyec ?00'ISnI�j�±M ngWa.::PrF+en hzwneM _ ^M StTe Under Honda law,email addresser are oubllc records.Iryou do not wancy0ur a-mall aJtlress rebeead io rapanee to a aub4cncmtls repues,do not rand ele@ond mall b Nrs entlly.Instead,cdn the owe by prom or by traditional malls!you have any qumdons,Please contact 850.407.1395.ePorsuant to del 455.D5(1). Ronda Stables.eneMw October1.212, Incesees licensed under ddapmr 45S.M.musty the0eeama¢ntw an ameY editions N tie)""one.T'R ama0s pNWded may be used for oTtlal communotbn with the Ikensee.Hmmvor email addressb are public reroN.1r you do not alum to au any a ph onal addRss.Plane Piv,Me the deWnmem whin an smell adel wraith On be made avallable to the purl k.ID determine Hyou an a Ikensee under Chapter 455.FS.,please darkfal Poor..,,ro alAcepb: ME ® Eil® Credit Card Safe ® CREEK Certificate OfAuf17520 Erin bur 20024 t752A Edinburgh 3647 Tampa,FL 3384] TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING COM r EMON(2020) Manufacturer: BEACON SALES ACQUISITIONS,INC. Issued October 14,2020 o'o OWENS CORNING ROOFING AND ASPHALT LLC 1 Owens Coming Parkway Toledo,OH 43657 (800)438-7465 wenagmTnscoming corn Manufacturing Location: Houston,TX Brentwood,NH Quality Assurance: PRI Construction Materials Technologies,LLC (QUA9110) SCOPE Category: Roofing Subcategory: Undedayments Coda Sections: ifiWAA,1507AAA Properties: Physical properties REFERENCES Entity Report No Stan am Year PRI Construction Materiels Technologies(TST8049) OCF-294-02-01 ]CC-ES AC 188, 2012 ICGESAC48 2012 PRI Construction Marshals Techndaglas(TST6049) 0CF-338-02-01 ASTM D 1970 2015e 'Delenninetl M to squholent to ASTM D 226-09,Tyme II PRWUCT DESCRIPTION TRI-BUILT Granular A self-adhered undenayment used as an alternative to ASTM D 226,Type II roofing felt. Underlayment The undedayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-fit z 65-R. Sea manufacturer's installation instructions for further detail. OCR20001 FLU539 page 1 of 3 This evaluator report Is provided tar Stela d Florida product approval uMer Rule 61GM0 . The manufechaer shot Iw.liry CREFJ( Technical Services,LLC of any product changes or qm ty assurance changes throughput No duration for which this report is valid. This evduatbn report does not espress nor Imply warranty,installation,recommended use,or other R."atdodes died,are net imedficeey adilm need herein. ® CREEK CORNING ROOFING MD ASPHALT INC. rile OWENS COBEAC RO,FlS ACOASIONS, LLC TECHNICAL SERVICES, LLC TRI-BUILT Granular Underlayment APpucitTIGN Roof Deck: The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Deck shall be installed in accordance with FBC requirements. Roof docks shall have no more than 118"gap at abutting joints. Min.slope: 2:12 or in accordance in with FBC Application: Prior to beginning installation, the undedayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The undedayment installation shall comply with FBC Table 1507.1.1.i. The undedayment shall be Installed with the roll length parallel to the save,starting at the save fold the undedayment away from save onto Itself. The undedayment shall be installed direct-to-decking with the lower release backer removed and pressed firmly Into place to ensure complete contact with the deck. Repeat with upper release backer. Overlap successive courses with minimum W side laps and minimum 6'staggered end laps. In steep-slope applications (>6:12), it is permissible to nail the undedayment 12- inches on-center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlaynamt). For valley applications, the roll shall be applied centered along the valley prior to Installing the underlayment at the eave and overlapped a minimum of 6-inches. For save protection, the undedayment should extend to a point 18-inches beyond the interior wall. Min.Application Temperature: 40°F;Contact the manufacturer when installing at temperatures below the minimum application temperature. Allowable roof coverings: Mechanical attachment of asphalt shingles and slate shingles shall be permitted In accordance with the FBC. OCR20001 FL3409 Page 2 of 3 TNs evaluation report Is provid MbrS of Florida product approval under RNe 61G2o-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality easurance changes throughout the duration for wrich thin report Is wild. This evaluation report does not express an,Imply wam,rty,insrallalon,recommended use,m other product etdb.M that are not specifically addressed herein. d CREEK COMING ACQUISITIONS,INC. Go OWENS CORNING ROOFING AND ASPHNS,LLC TECHNICAL SERVICES,LLC TRMILT Granular Underlayment LIMITATIONS 1) This evaluation report is not for use in me HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance In not within scope of this evaluation. 4) Installation of the evaluated product shall rwmpty with this report,fire FBC,and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 51 Deck substrates shaft be clean,dry,and free item any hregularmes and debris. All fasteners In the deck shall be checked for protrusion and corrected prior to undedaymenl application. 6) The undedayment may be used as described in other current FBC product approval documents. 7) Roof coverings shall not be adhered directly to the underayment. Roof coverings shall be mechanically fastened through the undedaymenl to the roof deck. 6) The undedaymenl shall not be installed over existing roof coverings. S) The undedayment shall be insiaged starting at the save in horizontal layers such that the laps shed water from the deck. The first layer shall cover the entire bottom edge of the deck. End laps shall be staggered a minimum of 24-inches from the preceding course. ,0) The undedayment shall be exposed on the roof dock for a maximum duration of 30 days. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G203. COMPLIANCE STATEMENT The products evaluated hemin by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,7"Edition 12020)as evidenced in the referenced documents submitted by the named manufacturer. �p`ttpP�' rR,rle�aap 2020.10.14 Np 74D2, � 15:45:22 '9 •, STATE OF :•w� ��,�•;.n e,�•���r Zachary R.Priest,P.E. �p'`G��p Florida Registration No.74021 ,S,.�NAi Ep``1% Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREED(TeuMiul Smicas.LLC does not have,rarest X acquire,a Murcial interest in any cwrers,manuf rriera ng or disMb,Nng pWuds uMerrs evelua0w,. CREEKTepM,lcgs ices,LLCis Mtowned,cpemled,wcmtmHedbyanycompanymmufaduMgordis111buNngpro taunderthlsevaluatm, Zachary R.Press,P.E.does Mhave.nwvAAcquire,aMencialImmre Inanympmymenuhcwnngordl#lbufirgpmdMInunder NisevaluaY . Zadlary R.Pocat P.E.does not(lave,nonml act,".a financial interest a any dharenliry Involved In the approval pmcue mina product. END OF REPORT OCR20031 FL3463a Page 3 of 3 This evaluation report is previded for State of Florida product approval under Rule 61G203. The manufacturer shall nasty CREEK Technical Services,LLC of any product changes or quality assurance changes throughout are duration for which this report is valid. This evaluation re"dons rot express net imply warmnty,irlslallatlon,recommended use,or other product aadbules that are not specifically addressed herein.