Loading...
HomeMy WebLinkAbout#42463 - McDuffie, Edward Reroofingform r FORT PIERCE ` BUILDING DE PA H'1'M£N"I' r�, wdre Reroofing Form Property Address: 4000 Greenwood Dr Fort Pierce 34982 Owners Name: Edward MCDuffie Description of Work: Re-Roof Shingle FLAT Roof Specifications: Owens Corning Tru Def Duration Roof Deck 1: Roof Dimensions: 4 Pitch -28 Squares Square Footage: 2800 Mean Roof Height: 15, Pitch/Slope: 4112 Rotten Wood: ❑ Yes IN No Roof Type: ❑ Gable q Hip DiFlat ❑Other. Roof Material: U Shingle ❑Metal ❑Tile E3 Mod. Bit. ❑Other: Underlayment: Waetherlock Felt (lb.): Roof Deck 2 (If applicable): Roof Dimensions: 4 Pitch-40 Squar Square Footage: 2800 Mean Roof Height: 15 Pitch/Slope: 0/12 Rotten Wood: ❑ Yes ® No Roof Type: ❑ Gable 19 Hip 93FIat []Other: Roof Material: IB Shingle ❑Metal ❑Tile IM Mod. Bit. []Other: Underlayment: Felt (Ib.J: "Florida Product Approval or Miami-Dade Notice of Acceptance is required for all products other than felt** 100 NORTH J5 1.FORT PIERCE.FLORIDA 34950-CITYOFFORTPIERCE.COM-TEL 772-467.3000-FAX.772.467.3849 '31 LUCIE Section D (Steep Slope Roof System) Roof System Manufacturer: Owens Corning Notice of Acceptance Number: FL10674-R16 Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): Zone 1:'7_Zone 2e:"7Zone 2nr108 Zone 2r:IO8 One 3e: 108 one 3r:128 \Tyl* od t: WeathN/Aer: N/Aails ner Type&Spacing: t 14 mg ankNiP.IrI Adhe"Tom: N/A �Cap sheet N/ARoof covering Asphalt Shingles Type&Stm Drip 3" X 3" Galy AIUm Edge: ST. LUCIE WORKS Section C (Low Slope Roof) Surfacing: Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment: manufacturer Zone 1':_..." oc @ Lap,#Rows 0 'o0 (If a component is not used,identify as"NA") Zone 1:_" oc @ Lap,# Rows 0 coo System Manufacturer: (, rtainte d Zone 2:— "oc @ Lap,#Rows 'ao Product Approval No.: FL2533-R24 Zone I " oc @ Lap,# Rows 0 moo Number of Fasteners Per Insulation Board: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': one 1: one 2: Zone 3: Zone 1':-34.6 Zone 1:6a•3Zone 2: Zone 3-1 08.4 Illustrate Components Noted and Details as Applicable: Max. Design Pressure,from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping, system: -�27.5 Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing,Coping, Etc. .. Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base Type: Wood Indicate: Component Material,Material'Thickness,Fastener 1/811 Type,Fastener Spacing or Submit Manufacturers Details that Gauge Thickness: Comply with RAS 111 and Chapter 16. Slope: Anchor/Base Sheet&No.df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: FT. Insulation Base Layer: Base Insultation Size and Thickness: Parapet Base Insulation Fastener/Bonding Material: Height Top Insulation Layer: FllntlaStic Top Insulation Size and Thickness: FllntlaStic FT. Top Insulation Fastener/Bonding Material: 15' Mean Base Sheet(s)&No.of Ply(s): FllntlaSfjC Roof Base Sheet Fastener/Bonding Material: Drip Edge:3"X 3"Galy Alum Height SA Ply Sheet(s)'&No.of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Fllntlastic Top Ply Fastener/Bonding Material: a SA