Loading...
HomeMy WebLinkAboutAPPROVED MANUAL Jwrightsoft Project Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34M Phone, 77246"799 Email: QUICKCALCSCAOL.COM For. JANET BALBO 7912 HORNED LARK CIR., PORT ST. LUCIE, FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Job: Date: By. Summer Design Conditions 42 °F Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 9302 Bluh Ducts 1�0 Cvent (0 c fm) BBtuhEku (none) Humidification 0 Btuh Piping 0 Bluh Equipment load 10902 Btuh Infiltration Method Construction quality Fireplaces Simplified Average Heating Cooling Area (M 2 458 1,lolume (ft) 3588 3588 Air changeslhour 0,61 0.32 Equiv AVF (dm) 36 19 Heating Equipment Summary Make Carrier Trade Model 38MHRB012 AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 30 OF Backup. 10.6 HSPF 17900 Btuh @ 47" F 28 4 573 tiro 0.053 dm/Btuh 0 in H2O 90 OF 75 OF 15 M OF 50 % 61 grAb Sensible Cooling Equipment Load Sizing Structure 8515 Btuh 1 �0 CCeentral vent (0 dm) �h (none) Blower 0 Btuh Use manufacturers data n Rate/swing multiplier Equipment load 0.95 9958 Btuh sensible Latent Cooling Equipment Load Sizing Structure 799 Btuh Btuh Central vent (0 dim)5 0 Btuh (none) Equipment latent load 1394 Btuh Equipment Total Load (Sen+Lat) Req. total capacity at 0.70 SHR 11351 1.2 Btuh ton Cooling Equipment Summary Make Carrier Trade Cond 38MHRBQ12 Coil 4OMHH012 AHRI ref Efficiency Sensible cooling Latentowling Total cooling Actual airflow Air flow factor Static pressure Load sensible heat ratio 13.0 EER,19 SEER 8400 Btuh 3600 Btuh 12000 Btuh 573 drn 0.055 cfrn/Btuh 0 in H2O 0.88 Input = 3 kW. Output -10915 Btuh 100 AFUE BakfBaic vakm have been manualy ove"N*n Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrl htsoR* 2021-00-0107�816 AK-pla�--< — RigWSUiSOLAiversa1202121.0.08 RSU08101 Page 1 ...UICK1D00rrartWVdghsoll FNACIBALBO, JANETnp Cak:= MJB FrortDoor face& N - wrightsoft Right-J® Worksheet Job: Entire House Date' QUICK CALCS, INC. By. 317 ST. LUCIE LANE. FL PIERCE, FL 34946 Phone- 772466-6799 Email: QLACKCALCS@AOL.COM 1 Roan name EntireHouse ENCLOSED PORCH 2 EVosedYell 60.0 A 68.0 n 3 Room height 7.8 R 7.8 A hoaGaod 4 Roam dimensions 46.0 x 10.0 R 5 Roam area 460.0 R* 460.0 r TY construction U-%Wue Or HTM Area (IF) Load Area Load number (8tuh k`L F) or perimeter (it) (Btuh) or Perimeter (11) (Btuh) Had Cod Gross NJP)S Had Cad Gross NAS Heal Cad 6 1pr 12B-Oar 0.097 ne 2.72 Z34 78 15 41 35 78 15 41 35 —r ID-c2ow 0.570 ne 16.96 14.94 63 0 1005 941 63 0 1005 941 w 12B-Osw 0.097 se 2.72 Z34 16 16 42 36 16 16 42 36 1¢r 12B-09w OD97 w 272 Z34 78 27 74 64 78 27 74 64 11 10B-w OJBW MN 116.80 25.19 19 0 324 485 19 0 324 485 i�GG ID-c2ow O.570 sw 15.96 15.32 32 0 503 482 32 0 sw 482 1q! 12BAaw 0.097 nw 2.72 234 359 138 376 323 359 138 376 323 t—G ID-c2ow 0.570 nw 15.96 14.94 221 0 3519 3295 221 0 3619 3295 C 168-30md 0.032 0.90 1.60 460 400 412 736 460 460 412 736 F 22A-tpl 0.9m - 27.69 0.00 460 68 1883 0 460 68 1883 0 61 c) AED emmusion 118011 11801 Enuslopeloss(gain 8179 8199 8179 8199 12 a) 4iEltrabon 1123 315 1123 315 b) Roam w4lation 0 0 0 0 13 p9ernalgairs: Omipanlse 230 0 0 0 0 Apprancesaolher 0 0 SubbW (fines6 b 13) 9302 8515 9302 8515 Less exi wW load 0 0 0 0 Lesstransfer 0 0 0 0 Recisttibution 0 0 0 0 14 Subdel 9302 8515 9302 8515 15 Dudloads 17% 23% 16W 1967 1796 23% 1600 1967 TcCW room bad n:..e...:.� �.s..� I 10MI nz 104821 "1 I I 10N2I C71 10482I "I Calculations approved byACCAto meet all requirements of Manual J 8th Ed. i'� wriQhstaa4TC 2021-Oct-01072816 PogFF.Sd1e®Uriuersa12021 Z1A.08 RS1108101 Pagel LACKrpoamerftWrigftDfI NACOALSO.JANETnp Cak=MA Frorttborfaoes: N FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: JANET BALSO Builder Name: Street: 7912 HORNED LARK CIR. Permit Office: City, State, Zip: PORT ST. LUCIE, FL, Permit Number: Owner: JANET BALSO Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing Addition 10. Wall Types(544.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Frame - Wood, Exterior R=11.0 544.00 fr b. NIA R= ff 3. Number of units, if multiple family 1 c. NIA R= ft- 4. Number of Bedrooms 0 d. NIA R= ft- 5. Is this a worst case? No 11. Ceiling Types(458.0 sgft.) Insulation Area 6. Conditioned floor area above grade (W) 458 a. Under Attic (Vented) R=30.0 458.00 ft` Conditioned floor area below grade (ft2) 0 b. NIA c. NIA R= fe R= fe 7. Windows(334.4 sgft.) Description Area 12. Ducts, location & insulation level R ft a. U-Factor. Sgl, U=0.60 334.36 ftz a. SHGC: SHGC=0.30 b. b. U-Factor: NIA ft2 C. SHGC: 13. Cooling Systems kBtulhr Efficiency c. U-Factor: NIA fe a. Central Unit 12.0 SEER:19.00 SHGC: Area Weighted Average Overhang Depth: 2,000 ft Area Weighted Average SHGC: 0.300 14. Heating Systems kBtulhr Efficiency 8. Skylights Description Area a. Electric Heat Pump 12.0 HSPF:10.60 U-Factor:(AVG) NIA NIA fe SHGC(AVG): NIA 9. Floor Types Insulation Area 15. Water Systems -None required a. Slab -On -Grade Edge Insulation R= 0.0 2 458.00 ft aHott @ Ca NIA p' b. NIA R= x ft2 b. Conservation features c. 16. Credits None Glass/Floor Area.0,730 Total Proposed Modified Loads: 14.06 Total Baseline Loads: 14.32 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this I tiE SrArF Code. calculation indicates compliance' %,, Os• with the Florida Energy Code. F m'n� „4 PREPARED BY: Before construction is completed this building will be inspected for DATE: 10-1-2021 compliance with Section 553.908 I hereby that this building, designed, is in Florida Statutes. * ¢ � certify as compliance QQ WE with the Florida Ener y Code OWNER/AGENT: da. BUILDING OFFICIAL: DATE: 10 • 1 - L1 DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Proposed Qn of NAN exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405.2.3 - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 10/1/20217;26:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: JANET BALBO Building Type: User Owner: JANET BALSO BuilderName: Permit Office: Jurisdiction: FamilyType: Detached New/Existing: Addition YearConstruct: Comment: Bedrooms: 0 CondilionedArea: 458 Total Stories: i Worst Case: No RotateAngle: 0 Cross Ventilation: No Whole House Fan: No Terrain: Suburban Shielding: Suburban Addresstype: Street Address Lot#: --- BlocklSubDivision: -- PlatBook: --- Street: 7912 HORNED LARK CIR. County: St. Lucie City, State, Zip: PORT ST. LUCIE, FL, CLIMATE Design Location Design Temp Tmy Site 97.6% 2.5% Int Design Temp Heating Design Dailytemp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 458 3664 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated 1 ENCLOSED PORCH 458 3664 No 0 Yes Yes Yes FLOORS (Total Exposed Area = 458 sq.ft.) # FloorType Space ExposedPerim PerimeterR-Value Area U-Factor JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edge Ins ENCLOSED PORCH 68 0 458 ft 0.473 — 0.00 1.00 0.00 ROOF V# Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 483 ft' 0 ft' Medium N 0.6 No 0.7 No 0 18.43 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 458 ft' N N CEILING (Total Exposed Area = 458 sq.ft.) # Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type 1 UnderAttic(Vented) ENCLOSED PORCH 30.0 Blown 458.0ft' 0.053 0.10 Wood 10/1/2021 7.26.47 AM EnergyGauge® USA 7.0,00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS (Total Exposed Area = 544 sq.ft.) V# Adjacent Omt To Wall Type Cavity Width Space R-Value Ft In Height Area U- Sheath Frm. Solar Below Ft In sq.ft. Factor R-Value Frac. Absor. Grade _ 1 2 -3 4 NE Exterior Frame - Wood SE Exterior Frame - Wood SW Exterior Frame -Wood NW Exterior Frame - Wood ENCLOSED PORCH 11.0 10.0 0 ENCLOSED PORCH 11.0 2.0 0 ENCLOSED PORCH 11.0 10.0 0 ENCLOSED PORCH 11.0 46.0 0 8.0 0 80.0 0.102 0 0.25 0.40 0 % 8.0 0 16.0 0.102 0 0.25 0.40 0 % 8.0 0 80.0 0.102 0 0.25 0.40 0% 8.0 0 368.0 0.102 0 0.25 0.40 0 % WINDOWS (Total Exposed Area = 334 sq.ft.) V# Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area -Overhang----- Depth Separation InteriorShade Screening _ 1 NE i Metal Single(Clear) 2 SW 3 Metal Single(Clear) - 3 SW 3 Metal Single(Clear) 4 NW 4 Metal Single(Clear) Yes 0.60 0.30 N N 63 0ft Yes 0.60 0.30 N N 19 4ft2 Yes 0.60 0.30 N N 31 5ft2 Yes 0.60 0.30 N N 220 5ft2 2.0 fk 0 in 1.0 ft 4 in Drapes/blinds Exterior100% 2 0 It 0 in 1.0 ft 4 in None None 2.0 ft 0 in 1.0 It 4 in Drapesiblinds Exterior100% 2.0 ft 0 in 1.0 It 4 in Drapes/blinds Exterior100% INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse ProposedACH(50) 0.00025 305 16.75 3145 00902 5.0 All MASS # Mass Type Area Thickness Furniture Fraction Space 1 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 ENCLOSED PORCH HEATING SYSTEM # System Type/FI.Addition SubtypelSpeed AHRI # Efficiency Capacity-GeothermalHeatPump- Ducts Block kBtulhr Entry Power Volt Current 1 Electric Heat Pump/Replace Split/Single HSPF: 10.60 12.0 0.00 0.00 0.00 Sys#0 1 COOLING SYSTEM # System Type/FI.Addition Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block kBtulhr cfm 1 Central Unit/Replace Split/Single SEER:19.0 12.0 0 0.70 Ductless 1 HOT WATER SYSTEM # SystemType Subtype Location EF(UEF) Cap Use SetPnt FixtureFlow Pipe Ins. Pipelength Recirculation RecircControl System Type Loop Branch Pump DWHR length length power Facilities Equal DWHR Other Credits Connected Flow Eft 10/i12021 7:26:47 AM EnergyGaugeg USA 7.0.00 - FlaRes2020 FBC 71h Edition (2020) Compliant Software Page 3 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT DUCTS Supply--- ----Return Air CFM 25 CFM 25 HVAC # VDuct # Location R-Value Area Location R-Value Area LeakageType Handler TOT OUT ON RLF Heat Cool TEMPERATURES ProgramableThermostat: N Ceiling Fans: N Cooling [ ] Jan [ ] Feb []Mar [ ] Apr [) May (X) Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [) Apr [I May []Jun []Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting I] Jan [ ] Feb [X] Mar [X] Apr [] May [ ] Jun []Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Coaling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 10/1/2021 7:26:47 AM EnergyGaugeO USA 7 0 00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Pane 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 7912 HORNED LARK CIR.,PORT ST. LUCIE,FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) 7. Windows— Description a. U-Factor; Sgl, U=0.60 SHGC: SHGC=0.30 b. U-Factor: NIA SHGC: c. U-Factor: NIA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description U-Factor:(AVG) NIA SHGC(AVG), WA 9. Floor Types Insulation a. Slab -On -Grade Edge Insulation R= 0 0 b. NIA R= c. NIA R= Addition 10. Wall Types(544,0 sgft.) Insulation Area Detached a. Frame - Wood, Exterior R=11.0 544.00 ft2 b. NIA R= ftz 1 c. NIA R= ft2 0 d. NIA R= ftz No 11. Ceiling Types(458.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 458.00 ft3 458 b. NIA R= ft2 0 c. NIA R= ft2 Area 12. Ducts, location & insulation level R ft2 334.36 ft2 a. b. ft2 C. 13. Cooling Systems kBtulhr Efficiency ftz a. Central Unit 12.0 SEER:19.00 2.000 ft 0.300 14. Heating Systems kBtulhr Efficiency Area a. Electric Heat Pump 12.0 HSPF:10.60 NIA 42 Area 15. Hot Water Systems - None required 458.00 ft2 a. 2u@ Cap: NIA ft2 b. Conservation features 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card wil! be completed based on installed Code compliant features. Builder Signature: Date: 3O -k - 7 i Address of New Home: 7912 HORNED LARK CIR. City1FL Zip: PORT ST. LUCIE,FL, 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating For information about the Morida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/1120217:26:47 AM EnergyGauge® USA 7.0 00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA" Project Name: JANET BALBO Builder Name: Street: 7912 HORNED LARK CIR. Permit Office: City, State, Zip: PORT ST. LUCIE, FL, Permit Number: Y Owner: JANETBALBO Jurisdiction: t� Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) i U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeableinsulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceilinglsoffil shall be aligned with The insulation in any dropped oeiling/soffit Ceilinglattic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame wells The junction of the top plate and the top of exterior walls shall be shall be insulated by completely tilling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior thermal envelope insulation far framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and anddoors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier, Rim joists shall be insulated. Floors The air barriershall be installed alany exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation andcantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl spacewalls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped, shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narroweavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conformstothe available cavity spaces. Garageseparation Air sealing shall be provided between the garage and conditionedspaces. Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exteriorwalls, or insulation that on installation readily conformsto available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exteriorwalls adjacent to showers Exterior walls adjacent to showers and tubs shall onexteriorwall and tubs shall separate them from the showers and tubs. beinsulated. Electricallphonebox The air barrier shall be installed behind electrical or onexteriorwalls communication boxes or air -sealed boxesshall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering orceiling penetrated bythe boot. k,onceaied .+n n..l.l..... Wrien required to oe seaiee, concealed fire sprnnkiers snaii on y 6........1..41.................1_.f..-.i".,.l... r.._ n . C--I '- Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 10/1/2021 7:26:47 AM EnergyGauge® USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 ir- Performed for. JANET BW_BO M2 HORNED LARK CIR PORT ST. LUCIF. FL A r17714. QUICK CALLS, INC. 317 ST. LUCIE LANE FT. PIERCE, FL 34946 Phone: 772A6E6799 QUICKCALCS cQAOL.COM Page 1 R#t&AOUrwasal2021 21.00B RSU08101 2021-Oct 01072@41 V*UttscRWCIMALBO. JANETnp