Loading...
HomeMy WebLinkAboutENERGY CALCSFORM R405-2020 FLORIDA ENERGY -EFFICIENCY CODE: FOR'BUILDING CONSTRUCTION Florida. Department of -Business. and Professional. Regulation - Residential Performance Method Project Name: 8403 Coquina Avenue , Builder Name: 'Habitat for. Humanity Street: 8403 Coquina Avenue Permit Office: City, State, Zip: Ft. Pierce, FL, Permit Number::, Owner: Jurisdiction: 'Design Location: FL, Fort Pierce County.: St. Lucie(Florida.Climate Zone.2) 1. New construction.or' existing • _ _ New (From Plans) 10. Wall Types(1320.0 : sgft.) Insulation Area 2. Single family or multiple family Detached a.- Concrete Block -1nt Insul, Exterior R=4.'1 1092.00 ftZ b:' Concrete Block - Intansul, AdjacenR=4.1 228.00 ftZ 3. Number of.units, if multiple family 1 c.. N%A R= R 4. Number of Bedrooms 3 d: N/A ftZ 11. 'Ceiling Types(13370 sgft:) Insulation Area 5. Is this. a worst . case? No R=30.0 1337.0.0 ftZ ' � a. Under Attic (Vented) •6. Conditioned floor area above.grade (ftZ) .:. - - -1335 b. N/A R= • ftZ Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 7. Windows(85.9 sgft:) Description Area 12. Ducts, location & insulati on. level R ftZ a.: U-Factor:' . ON, U=0.66 85.94 ftZ a. a. Sup: Attic,: Ret: Attic, AH: Attic 6 267 SHGC: SHGC=0.25. b• -. b. U-Factor: N/A ftZ.. C. SHGC: 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: N/A. ftZ a. Central Unit 27.6 SEER:16.00 SHGC: . Area.Weighted Average Overhang Depth: . - 1.500 ft Area Weighted Average SHGC: 0.250 14. Heating Systems kBtu/h,r Efficiency 8. Skylights - Description Areaa. Electric Strip Heat 27:3 COP:1.00 U-Factoe(AVG) N/A" N/A ft?.. SHGC(AVG): NIA 15. 'Hot Water Systems 9. Floor Types Insulation Area . a: Electric Cap: 40 gallons' . a. Slab -On -Grade Edge insulation R= 0.0 1334.80 ftZ EF: 0.950 b. N/A R= ' ftZ b. Conservation features c. N/A R= .... ftZ None 16. Credits: CF, CV .42.34 Glass/Floor.Area: 0.064 Total ProposedTotal Baseline Loads: 42.35 . PASS:.. hereby certify:that the plans and specifications covered by Review of the plans and �t�Fa 3TgT this calculatioware in compliance with the Florida.Energy specifications. covered by this p� A Code. calculation indicates compliance1'',,j with the Florida Energy Code.rp � /fr A1rri�r s '• -r a,uu G, �GGT'i?.GLI1i Before construction is completed:. PREPARED BY: -- 11 'this building will be inspected for ' td �,•�1)o DATE: dull@ 2, 21 compliance with Section 553.908 a. . Florida Statutes.. hereby certify that this building, as designed, is in compliance t'Ob WTa� with the Florida Ener Ce OWNERIAGENT: ': �^ BUILDING OFFICIAL: DATE: O _L ly�2 DATE: .. :.. - Compliance requires certification by the air handler unit • manufacturer that the air handler enclosure qualifies as certified:facto .y-sealed in accordance with R403.3.2.1. Compliance with a -proposed duct leakage: 4n requires a. PERFORMANCE Duct Leakage Test Report confirming duct leakage to. outdoors; tested in accordance with ANSIIRESNETIICC :380, is notgreater than.. 0.000 Qnfor whole:house. : - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this. project .. requires a PERFORMANCE envelope leakage .test reportwith envelope leakage: no greater -than 7:00 ACH50 (11402.4.1.2). ftware Page 1 6/2/2021 4:59:31 PM' Energypauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant So FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 8403 Coquina Avenue Address type: Street Address Building Type: User Bedrooms: 3 Lot #: --- Owner: Conditioned Area: 1335 Block/SubDivision: - Total Stories: 1 PlatBook: - Builder Name: Habitat for Humanity Worst Case: No Street: 8403 Coquina Avenue Permit Office: Rotate Angle: 0 County: St. Lucie Jurisdiction: Cross Ventilation: Yes City, State, Zip: Ft. Pierce, Family Type: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban Year Construct: Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range _ FL, Fort Pierce FL VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1335 10680 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated 1 Bed 2 197 1576 No 1 1 Yes Yes Yes Yes Yes Yes _ _ 2 clst 2 21 168 No 0 0 Yes Yes Yes _ 3 Bath 2 117 936 No 1 1 Yes Yes Yes _ 4 Bed 3 191 1528 No 0 Yes Yes Yes 5 clst 3 18 144 No 0 Yes Yes Yes 6 Kit Din LR 497 3976 Yes Yes Yes Yes - 7 pnty 21 168 No 0 2 1 Yes Yes Yes _ g Bed 175 1400 No 0 Yes Yes Yes _ g clst 1 18 144 No 0 Yes Yes Yes _ 10 Bath 1 80 640 No FLOORS (Total Exposed Area = 1335 sq.ft.) F# Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet Floor Type 1 Slab -On -Grade Edge Ins Bed 2 33 196.5 ft 0.710 21 ft 0.710 - - 1.00 1.00 0.00 0.00 0.00 0.00 _ Slab -On -Grade Edge Ins clst 2 3 117 ft 0.710 - 1.00 0.00 0.00 -2 Slab -On -Grade Edge Ins Bath 2 9 190.5 ft 0.710 - 1.00 0.00 0.00 -3 4 Slab -On -Grade Edge Ins Bed 3 26.5 17.5 ft 0.710 - 1.00 0.00 0.00 _ 5 Slab -On -Grade Edge Ins clst 3 2.5 497 ft 0.710 - 1.00 0.00 0.00 _ 6 Slab -On -Grade Edge Ins Kit Din LR 42 21.3 ft 0.710 - 1.00 0.00 0.00 _ 7 Slab -On -Grade Edge Ins pnty 2.5 175 ft 0.710 - 1.00 0.00 0.00 r_ 8 Slab -On -Grade Edge Ins Bed 1 26.5 17.5 ft 0.710 - 1.00 0.00 0.00 9 Slab -On -Grade Edge Ins clst 1 .5 81.5 ft 0.710 - 1.00 0.00 0.00 _ 10 Slab -On -Grade Edge Ins Bath 1 17.5 6/2/2021 4:59:31 PM EnergyGaugee USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT / # Type 1 Gable or Shed / # Type 1 Full attic ,/ # Ceiling Type 1 Under Attic(Vented) _ Under Attic(Vented) -2 Under Attic(Vented) -3 4 Under Attic(Vented) _ _ 5 Under Attic(Vented) Under Attic(Vented) -6 7 Under Attic(Vented) _ _ 8 Under Attic(Vented) 19 Under Attic(Vented) 10 Under Attic(Vented) ROOF Materials, Roof Gable Area Area Roof Rad Solar SA - Emitt Emitt Deck Pitch Color . Barr Absor. Tested Tested Insul. (deg) Composition shingles 1407 ft2 222 ft2 Medium N 0.9 No 0.9 No 0 18.43 ATTIC Ventilation Vent Ratio (1 in) Area RBS IRCC Vented 300 1335 ft2 N N CEILING (Total Exposed Area = 1337 sq.ft.) t F amin Frac Truss Type /Adjacent # Ornt To Wall Type 1 N Exterior Cone. Blk - Int Ins _ E Exterior Cone. Blk - Int Ins -2. W Exterior Conc. Blk - Int Ins -3 4 E Exterior Conc. Blk - Int Ins _ 5 E Exterior Conc: Blk - Int Ins _ E Exterior Conc. Blk - Int Ins -6 7 S Exterior Conc. Blk - Int Ins - 8 E Exterior Conc. Blk - Int Ins - 9 S Exterior Cone. Blk - Int Ins 10 N Exterior Conc. Blk'- Int Ins _ 11 W Garage Conc. Blk - Int Ins _ 12 S Exterior Conc. Blk - Int Ins _ 13 W , Exterior Conc. Blk - Int Ins _ 14 N Garage Conc. Blk -'Int Ins _ 15 W Exterior Conc. Blk - Int Ins _ 16 S Exterior Cone. Blk - Int Ins -17 W Exterior Conc. Blk - Int Ins Space R-Value Ins. Type Area U-Fac or r g Bed 2 30.0 Blown 197'Oft2 0.053 0.10 Wood Wood clst 2 30.0 Blown 21.Oft2 0.053 0.10 0.10 Wood Bath 2 30.0 Blown 117.0ft' 0.053 0.10 Wood Bed 3 30.0 Blown 191.Oft2 0.053 0.10 ood clst 3 30.0 '30.0 Blown Blown 18.0ft2 497.0ft2 0.053 0.053 0.10 Wood Kit Din LR prity 30.0 Blown 21.0ft2 ' 0.053 0.10 Wood Bed 1 30.0' Blown 175.0ft2 0.053 0.10 Wood Wood clst 1 30.0 Blown 18.0ft2 0.053 0.10 0.10 Wood Bath 1 30.0 Blown 82.0ft2 0.053 WALLS (Total Exposed Area = 1320 sq.ft.)' Cavity Width Height In Area U- Sheath Frm. Factor R Value Frac. Solar Below Absor. Grade Space R-Value Ft In Ft , sq.ft. Bed 2 4.1 13.0 6 8.0 0 108.0 0.149 0. 0 0 0.40 0 % 0.40 0 % Bed 2 4.1 13.0 6 8.0 8.0 ' 0 0 108.0 , 48.0 0.149 0 0.149 0 0 0.40 0 % Bed 2 4.1. 4.1 6.0 0 3.0 0 8.0 0 24.0 0.149 ' 0 0 0.40 .0 % clst 2 Bath 2 4.1 9.0 0 8.0 0 72.0 0.149. 0 0 O 0.40 0 0.40 Bed 3 4.1 13.0 6 8.0 0 0 108.0 104.0 0.149 0 0.149 0 0 0 40 0 %° Bed 3 4.1 4.1 13.0 0 2.0 6 8.0 8.0 0 20.0 0.149 0 0.40 0 % clst 3 Kit Din LR 4.1 13.0 6 8.0 0 108.0 0.149 0 0 0 0.40 0 %' 0.40 % Kit Din LR 4.1 14.0 0 8.0 0 112.0 116.0 0.149 0 0.149 0 0 0.40 0 Kit Din LR 4.1 14.0 6 6 8.0, 8.0 0 0 20.0 0.149 0 0 0.40 0 % pnty Bed 1 4.1 4.1 2.0 12.0 6 8.0 0 100.0 0.149 0 0 0 0.40 0 % 0.40 0 0 Bed 1 4.1 14.0 0 8.0 0 0 112.0 20.0 0.149 0 0.149 0 0 0.40 0° o clst.1 4:1 2.0 6 11.0 '6 8.0 8.0 0 92.0 0.149 0 • 0 0.40 0 % Bath.1 4.1 4.1 6.0 0 8.0 0 48.0•. 0.149 0. ' 0 0.40 0 Bath 1 DOORS (Total ExposedArea = 42 sq.ft.) Width Height U-Value Ft In Ft In Area Storms # Omt Adjacent To , Door Type Space ' Kit Din LR None 0.39 3.00 0 7.00 0 21.0ft2 1 N Exterior Wood Kit Din LR None 0.39 3.00 0 7.00 0 21.0ft2 '- 2 N Exterior Wood Page 3 6/2/2021 4:59:31 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 86 sq.ft.) -Overhang-- Wall ✓# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening 1 N 1 None Double (Clear) Yes 0.66 0.25 Y N 18.7ft2 1.0 ft 6 in 1.0 ft 0 in 1.0 ft 6 in 1.0 ft 0 in Drapes/blinds Exterior 50% Drapes/blinds Exterior 50% _ _ 2 S 7 None Double (Clear) Yes 0.66 0.25 Y N 16.9ft2 0.25 Y N 24.0ft2 1.0 ft 6 in 1.0 ft 0 in Drapes/blinds Exterior 50% _ 3 S 9 None Double (Clear) Yes 0.66 0.25 Y N 10.0ft2 1.0 ft 6 in 1.0 ft 0 in Drapes/blinds Exterior 50% _ 4 N 10 None Double (Clear) 13 None Double (Clear) Yes 0.66 Yes 0.66 0.25 Y N 16.4ft2 1.0 ft 6 in 1.0 ft 0 in Drapes/blinds Exterior 50% 5 W INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00036 1246 68.36 128.34 0.1263 7.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 383 1112 383 ft2 64 ft 8 ft 1 MASS # Mass Type Area Thickness Furniture Fraction Space 1 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 0.30 Bed 2 clst 2 2 Default(8 Ibs/sq.ft.) 0 ft2 O ft O ft 0.30 Bath 2 -3 Default(B Ibslsq.ft.) 0 ft2 0 ft 0.30 Bed 3 -4 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 clst 3 _ 5 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 Kit Din LR _ 6 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 pntY _ 7 Default(8 Ibs/sq.ft.) 0 ft2 ft 0.30 Bed 1 8 Default(8 Ibs/sq.ft.) 0 ft2 O 0.30 cast 1 ,-, 9 Default(8 Ibs/sq.ft.) 0 ft2 � 0.30 Bath 1 10 Default(8lbs/sq.ft.) HEATING SYSTEM Subtype AHRI # Efficiency Capacity -Geothermal HeatPump-- Ducts Block # System T Y Type kBtu/hr Entry Power Volt Current None COP:1.00 27.3 0.00 0.00 0.00 sys#1 1 1 Electric Strip Heat COOLING SYSTEM F#System Subtype/Speed AHRI # Efficiency CapacityAir FlowSHR Duct Block Type kBtu/hnrrn.fm r Ae n 1)7 R 0 0.74 sys#1 1 1 Central Unit 5puv5mgie - 6/2l2021 4:59:31 PM 9Y 9 Ener Gau eo USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric None Garage 0.95 (0.93) 40.00 gal 61.gal 120 deg Standard None 83 Recirculation Recirc Control Loop Branch , Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow ' Eff 1 No NA` NA NA No NA NA NA None DUCTS Duct --Supply Retum---- Air ' CFM 25 CFM 25 HVAC # # ' Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6.0 267 ft' Attic 6.0 67 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [ ] Jan [I Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar ( ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [I Feb [X] Mar [X] Apr (I May [ ] Jun []Jul [ ] Aug [ ] Sep [X] Oct (X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours 11 12 Schedule Type 1 2 3 4 5 6 7 8 9 10 _Cooling (WD) PM 80 80 80 80 78 78 78 78 78 78 78 78 _Cooling (1NEH) PM 80 80 80 80 78 78 78 78 78 78 78 78 _ Heating (WD) PM 68 68 68 68 68 68 68 68 68 68 68 68 _Heating (WEH) AM 68. 8 68 668 68 6 8 68 66 8 8 68 68 6/2/2021 4:59:31 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 J T 0 7 NZI FORM R405 2020 ER ENERGY PERFORMANCE LEVEL (EPL) DISPLsty-- F Ong ESTIMATED ENERGY PERFORMANCE INDEX*: =100 The lower the EnergyPerformance Index, the more efficient the home. 8403 Coquina Avenue,Ft. Pierce FL, 1. New construction or existing New (From Plans) A0. Wall Types(1320.0 :sgft.) Insulation Area ft2 a. Concrete Block - Int Insul, Exterior R=4.1 1092.00 2: Single family. or multiple: family Detached b. Concrete Block - Int:lnsul, AdjacenR=4.1 228.00 ft2: 3. Number of units, if multiple family 1 c. N/A R=• ft2. 4. Number of Bedrooms 3 d. N/A 11. Ceiling:Types(1337.0 sqft.) R= ft2 Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1337.00 ft2 6. Conditioned floor area above grade (ft2) 1335 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 Conditioned c. N/A R= 7. Windows** Description_ Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Dbl, U=0:66 85.94 ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 267 SHGC: SHGC=0.25 b• b. U-Factor: N/A ft2 SHGC: C. 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 27.6 SEER:16.00 SHGC: Area Weighted Average Overhang Depth: 1.500 ft Area Weighted Average SHGC; 0.250 14. Heating.Systems kBtu/hr Efficiency 8. 'Skylights Description Area:. a. Electric Strip Heat 27.3 COP.1.00 U-Factor:(AVG) N/A N/A ft2 SHGC(AVG); N/A 15. Hot Water Systems 9. Floor Types Ansulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R= 0.0 1334.80 ft2 EF: 0.950 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 16. Credits CF, CV I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be.completed based on installed Code compliant features. Builder Signature: Tt (/: Uate: _WLG�� Z Address of New Home: 8403 Coquina Avenue City/FL Zip: Ft. Pierce,FL, *Note: This is not.a Building Energy Rating: if your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating, For information about -the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida'Building Code, Energy Conservation, if not: DEFAULT. IRM 6/2/2021 4:59:56 PM EnergyGauge® USA 7.0,00 - FlaRe92020 FBC 7th Edition (2020) Compliant Software Page 1 of 1