HomeMy WebLinkAboutProject Summary-- wr-ightsofto Project Summary
Entire House
WebREPS, LLC
Job: p#1301.808-0102-000-0
Date: June 2, 2021
By: Josh Putman
Plan: 8403 Coquina Avenue
1892 Commerce Arenue, Vero Beach, FL 32960 Phone: 800-810-3280 Fax 888-971-2999 Email: sales@webrepshvac com ftb: www.webrepmuholesale.com License: CAC054709
Project Inf• •
For: Joseph Gianna, Habitat for Humanity
. Ft. Pierce, FL
Notes: 8403 Coquina Avenue Ft. Pierce Florida p#1301-608-0102-000-8
Design Information
Weather.
Winter Design Conditions
Outside db 42 OF
Inside db . 70 OF
Design TD. 28 OF.
Heating Summary
St Lucie County Intl, FL, US
Summer Design Conditions
Outside db
90
OF
Inside db
75
OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
56
grAb
Structure
13885 Btuh
Ducts _
3280 Btuh
Central vent (0 cfrn)
0 Btuh
(none)
Humidification
0 . Btuh
Piping
0 Btuh
Equipment load
17165 Btuh
Infiltration
Method
Simplified
Construction quality
Semi -tight.
0
Fireplaces
Heating Cooling
Area (ft�
1335 1335
Volume (ft')
10678 -10678
Air chang6ftur
0.'31 0.16
Equiv,AVF (cfm)
55 28
Heating Equipment Summary
Make Goodman
Trade Heat Strip
Model
AHRI ref
Efficiency
100 EFF
Heating input
8.0
kW .
Heating output
27297
Btuh
Temperature rise
27
OF
Actual airflow
920
clim
Airflowfactor
0.054
cfm/Btuh
Static pressure
0.60
in H2O
Space thermostat
Sensible Cooling Equipment Load Sizing
Structure
12772
Btuh
Ducts
5421
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower.
1707
Btuh
Use rhanufacturer's data
y
Rate/swingg multiplier
-�1.00
Equipmentsensible load -
19900
Btuh
Latent Cooling Equipment Load Sizing
Structure
5291
Btuh
Ducts
1416
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
6707
Btuh
Equipment Total Load (Sen+Lat)
26607
Btuh
Req. total capacity at 0:74 SHR
2.2
ton
Cooling Equipment
Summary
Make Goodman Mfg.
Trade GOODMAN.
Cond GSX160301 F .. -
.
Coil ASPT30C14A
AHRI ref 200825240
Efficiency 13.0 EER, 16 SEER
Sensible cooling
20424
Btuh
Latentcooling
7176
Btuh
Total cooling -
27600
Btuh
Actual airflow
920
cfm
Airflowfactor
0.051
cfm/Btuh
Static pressure
0.60
in H2O
Load sensible heat ratio
0.75
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
_ -, wrightsoft'
�- M� Right-Suite®Universal'202121.O.OTRSU2021-Jun-0216:56:29
16998 Pagel
ACCA,..abitatfor Humanity PSL)8403Coquina Atenue.rup Caic=MJ8 FrontDoorfaces: N
�0-
Job #: p#1301-008-0102-000-8
Performed by Josh Putman for.
Joseph Gianna
R. Pierce, FL
Sheet 1
WebREPS,. LLC
1892 Commerce Avenue
Vero Beach, FL32960
Phone:800-8103280 Fax:888.971-2999
www.webrepswholesale.com sales@webrepshvac.com
Scale:1 : 69
R4*aIkO Urivesal2021
21.0.07RSU16998
2021.1u)-M1aW36
PSW403CoqLi PvawrLp
Duct System Summary Job: p#1301-008-0102-000.8
wrightsofto y ry Date: June 2, 2021
Entire House By- Josh Putrnan
WebREPS, LLC Plan: 8403 Coquina Avenue
1892 Commerce Aoenue, Vero Beach, FL 32960 Phone: 800-810-3280 Fax 888-971-2999 '.Email: sales@webrepstmc.com Mb: www.webrepswholesale.corn License: CAC054709
e-roject intormation
For: Joseph Gianna, Habitat for Humanity
Ft. Pierce, FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual airflow
Total eftective length (TEL) .
Heating
0.60 in H2O
0.24 in H2O
0.36 in H2O
0.226 / 0.134 in H2O
0.084 in/100ft
920 dim
427 ft
Supply Branch Detail Table
. Cooling
0.60 in H2O
0.24 in H2O
0.36 'in H2O
0.226 / 0.134 in H2O
0.084 in/100ft
920 . cfm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Mat
Actual
L-n (ft)
Ftg.Egv
Ln (ft)
Trunk
Bath 1
h 1805
97
43
0.093
6.0
Ox 0
VI Fx
18.2
225.0
st2
Bath 2
c 1357
59
69
0.089
5.0
Ox 0 ..
VIFx
24.6
230.0' .
st4
Bed 1
h 2653
142
141
0.093
7.0
Ox 0
VIFx
17.1
225.0
s12
Bed 2
h 3515
188
122
0.086
8.0
Ox 0
VIFx
32.7
230.0
st4
Bed 3
h 2897
155
116
0.084
7.0
Ox 0
VI Fx
32.8
235.0
st4
Kit Din LR
c 2124
70
107
0.100
6.0
Ox 0
VIFx
20.5
205.0
st3
Kit Din LR-A'
c 2124
.70
107
0.099
6.0
Ox 0
VIFx
18.0
210.0
st3
Kit Din LR-B
c 2124
' 70
107
0.096
6.0
Ox 0
VIFx
25.7
210.0
st3
Kit Din LR-C
c 2124
70
107
0.101
6.0
Ox0
VIFx
13.2
210.0
st3
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FIR
(fpm)
(in)-
(in)
Material
Trunk
st1
PeakAVF
920
920
0.084
613
15.0
12 x 18
RectFbg
st2
PeakAVF
239
184
0.093
684
8.0
0 x 0
VinlFlx
st1
st4
PeakAVF
403
306,
0.084
513
12.0
0 x .0
VinlFlx
st3
st3
PeakAVF
681
736
0.084
688
14.0
0 x 0
VinlFlx
st1
wrightsoftm - 2021-Jun-0216:56:29
Right Suite® Universal2021 21.0.07 RSU16998 Page 1
ACCA...abitatforHumanity PSLt8403Coquina Auenue.rup Calc=W8 FrontDoorfaoes: N
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
M
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mal
Trunk
rb4
Ox 0
920
920
1592 ,
0.084
521
18.0
Ox 0
VIFx
rt1
TableReturn Trunk Detail
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm), FR (fpm) (in) (in) Material Trunk
rt1 PeakAVF 920 920 0.084 409 15.0 18 x 18 RectFbg
2021-Jun-0216:56:29
WY ghtsoft- Ftight-Suite®Universal 202121.0.07RSU16998 Paget
ACCK ...abitatfor Humanity PSL\8403 Coquina aenue.rup Calc= MJ8 Front Door faces: N
(qJ f I Planning & Development Services Department
• Building & Code Regulations Division
-- • -- 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 4E
Certification for Design Load Compliance
Project Name: 8403 Coquina Ave
Project Address:
Permit #:
8403 Coquina Avenue Fort Pierce, FL 34951
Occupancy Type: R-3 Construction Type: VB
ST. Liar. :- u itYPermitting
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving he folloRiErEIVE a
o New Residences (single or multi -family) OCT ®°� 202)
o Residential Addition
o Any accessory structure requiring a building permit
ST. Lucie County, Permitting
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior. structu ra I elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida BUILDING Code Sixth Edition with 20 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 6 ft
5. Mean Roof Height 15 ft Roof Pitch: 4 :12 Parapet: NSA ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: 53.3 Zone 2: 70.4 Zone 3: 95.9 Zone 4: 33.2 Zone 5: 40.9 Garage:
7. Design Loads: Floor: NSA PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: NSA PSF
Dock: NSA PSF Deck: NSA PSF Stairs: NSA PSF Fence: NSA PSF Railings: NSA PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces s eCi liiii��.r����
Ryan M Bays
`�` �.• �� C ENS ' • '%� Print Name Cert # & Co. Cert Auth.
/.
No. •91 ?%^ Whole House Engineering
fo
OR
MA�..E�%
111nrr111 ii11+�►0.
4451 St Lucie Blvd Suite 201, Fort Pierce, FL 34946
Company Name & Address
L.-DIgyId%NWBE by Pyan M Bays
DN: 99
E.flyw..Bgs@ W HEn9l n eering_ne1,
Ryan M Bays =LX-L fml PlerceW-
I �Reaspn: I a�n approving Nls tlocumenl
DM6. 2621 0526 09 ":2B-04'Da'