HomeMy WebLinkAboutTruss Engineering4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946...
PH: 772-409-1010
FX: 772-409-1015
Juno uu,,ad www.AlTruss.com
OZOZ 1 j0
TRUSS ENGINEERING
BUILDER:
PROJECT:
COUNTY:
LOT/BLK/MODEL:
JOBM
M A S T E R M
HABITAT SLC .
8403 COQUINAAVE
ST LUCI E
8403 COQUINAAVE
CHHS10328
OPTIONS: NO OPTIONS
Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
These truss designs rely on lumber values established by others.
RE: Job 88836 , JOB #88836 A-1 Roof Trusses
4451 St Lucie Blvd
Site Information: Fort Pierce, FL 34946
Customer Info: HABITAT ST. LUCIE COUNTY Project Name: 8403 COQUINA AVE
Lot/Block: Model:
Address: 8403 COQUINA AVE, FORT PIERCE, FL. 34951vision:
City: County: EXEMPT State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City:
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading
Conditions):
Design Code: FBC 7th Ed. 2020 Res. / TPI 2014 Design Program: Alpine Engineered Products
Wind Code: ASCE 7-16 Wind Speed: 160
Roof Load: 40.0 psf Floor Load: 0.0 psf
This package includes 23 individual, dated Truss Design Drawings and 16 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules.
No.
Seq #
Truss Name
Date
No.
Seq #
Truss Name
Date
No.
Seq #
Truss Name
Date
1
2660
A01
9/27/21
13
2685
CO
9/27/21
25
STDL02
STD. DETAIL
9/27/21
2
2666
A02
9/27/21
14
2655
HJ7
9/27/21
26
STDL03
STD. DETAIL
9/27/21
3
2671
A03
9/27/21
15
2705
HJ7P
9127/21
27
STDL04
STD. DETAIL
9/27121
4
2676
A04
9/27121
16
2650
A
9127/21
28
STDL05
STD. DETAIL
9/27/21
5
2638
A05
9127121
17
2702
J1P
9/27/21
29
STDL06
STD. DETAIL
9/27/21
6
2649
A06
9/27/21
18
2647
J3
9/27/21
30
STDL07
STD. DETAIL
9/27121
7
2728
A07
9/27/21
19
2699
J3P
9/27/21
31
STDL08
STD. DETAIL
9/27/21
8
12723
A08
9/27/21
20
12644
J5
9/27/21
32
STDL09
STD. DETAIL
9127/21
9
2711
B01
6/27121
21
2696
J5P
9/27/21
33
STDL10
STD. DETAIL
9/27/21
10
2718
B02
9/27/21
22
2641
J7
9/27/21
34
STDL11 '
STD. DETAIL
9/27/21
11
2708
1 C01
9/27/21
23
2693
1 J7P
9/27/21
35
STDL12
STD. DETAIL
9/27/21
12
2690
1 CO2
9/27/21
24
STDL01
I STD.. DETAIL
9127/21
36
STDL13 I
STD. DETAIL
9/27/21
I he truss drawing(s) reterenced nave been prepared byPJpine Engineered Products, Inc. under my direct supervision based on the parameters provided byA 1 RoofTrusses, Ltd.
Truss Design Engineers Name: Ryan Bays
My license renewal date for the state of Florida is February 28,2023.
NOTE -The seal on these drawings indicate acceptance of professional engineering
responsibility soleyforthe truss components shown.
The suitability and use of components forany particularbuilding is the responsibility of the building
designer, perANSVrPl-1 Sec.2.
The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction /
documents (also referred to at times as'Structural Engineering Documents) provided bythe BulrJfig
Designer indicating the nature and characterofthe work
!!
The design criteria therein have been transferred to Ryan Bays PE by [Al Roof Trusses orspecitiic
location]. These TDDs (also referred to attunes as'Structural Delegated'
Engineering Documents) are specialty structural component designs and may be part of the pro
deferred or phased submittals. As a Truss Design Engineer (i.e., Specialty
Engineer), the seal here and on the TDD represents an acceptance of professional engineering
responsibility forthedesign of the single Truss depicted on the TDD only. The Building Designer is
responsible forand shall coordinate and review the TDDs for
.................
compatibility with theirwritten engineering requirements. Please review all TDDs and all related notes.
13
Ryan Bays, P.E.
4451 St Lucie Blvd. Suite 201
Fort Pierce, FL 34946
Byars M Bays
15:55:59."00'
Page 1 of 2
Job: Truss
CHHS10328 A01
io
=3;
N �
a-1Tc
i T
Truss type
HIPS
258# 189# g1 189#
i 189#i i 18
Cary my uU1Zf1LU141
2 Seal #: 2660
189# 189# 258#
i i 1 -- TO-318" =j
III1.5X3 =3X10 =H0308 1111.5X3
T
SEAT PLATE REQ. SEAT PLATE REQ.
28'
H H
�- 7'0-3/8" ZO-3/8" 2 2 V10-1/2" 2, 2, 2'0-318"
125E F 1� 149
492# 125# 125# 125#
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 10.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 10.00 Risk Category: II
EXP: C Kzt: NA
Des Ld. 40.00 Mean Height: 15.00 ft
NCBCLL: 0.00 TCDL: 5.0 psf
Soffit: 0.00 BCDL: 5.0 psf
Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 " C&C Dist a: 3.00 It
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2; T2 2x4 SP M-30;
Bot chord: 2x4 SP M-30;
Webs: 2x4 SP #3;
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 1 Row @12.00" o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
-(Lumber Dur.Fac.=1.25 / Plate Dur.Fac =1.25)
TC: From 61 plf at -1.00 to 61 plf at 7.00
TC: From 31 plf at 7.00 to 31 plf at 21.00
TC: From 61 plf at 21.00 to 61 plf at 29.00
BC: From 20 plf at 0.00 to 20 plf at 7.03
BC: From 10 plf at 7.03 to 10 plf at 20.97
BC: From 20 plf at 20.97 to 20 plf at 28.00
TC: 258 lb Conc. Load at 7.03,20.97
TC: 189 lb Conc. Load at 9.06,11.06,13.06,14.94
16.94,18.94
BC: 492 lb Conc. Load at 7.03,20.97
BC: 125 lb Conc. Load at 9.06,11.06,13.06,14.94
16.94,18.94
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 7.00 21.00
BC 112 0.15 27.85
Apply puriins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Pg: NA Ct: NA CAT: NA
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
Pf: NA Ce: NA
VERT(LL): 0.304 D 999 360
Loc R+ / R- / Rh / Rw / U / RL
B 2605 /- /- /- /1089 /-
Lu: NA Cs: NA
VERT(CL): 0.607 D 548 240
Snow Duration: NA
HORZ(LL): 0.061 F - -
F 2605 A /- /- /1089 /-
HORZ(TL): 0.122 F - -
Creep Factor: 2.0
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
Building Code:
FBC 7th Ed. 2020 Res.
Max TC CSI: 0.682
F Brg Width = 7.6 Min Req = 1.5
TPI Std: 2014
Max BC CSI: 0.976
Bearings B & F are a rigid surface.
Bearings B & F require a seat plate.
Rep Fac: No
Max Web CST: 0.450
FT/RT:10(0)/10(10)
Weight: 238.0 Ibs
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Plate Type(s):
VIEW Ver: 21.01.01A.0521.20
A- B 10 -7 D - E 1839 -4448
B: C 1451 -3517 E - F 1451 -3518
WAVE HS
Wind
C - D 1839 -4448 F - G 10 -7
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - K 3307 -1358 1- H 3329 -1359
K - J 3329 -1359 H - F 3308 -1358
J -1 3329 -1359
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp. Webs Tens. Comp.
C - K
354 -21 J - E 1180 -506
C - J
1181 -506 H - E 354 -21
D - J
354 -481
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. Ali notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C d.ht Q 2016 A-1 Rnnf Tni. sav - R"nrMnNinn of this dnntmant. in anv in=. Lc nmhihitad withrnR the written nennicdnn of A-1 Rnnf Tn,-.
Job: Truss Truss Type Qty Ply 09/27/2021 _=
CHHS10328 A02 I HIPS I 1 I 1 Seal #: 2666 AA_
fl
A
c) =4:
1 -,m,
SEAT PLATE REQ.
H
9'
10,
=3X4 =3X6 =3X4
Loading Criteria (psf)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
TCLL: 20.00
Wind Std: ASCE 7-16
Fig: NA Ct: NA CAT: NA
TCDL: 10.00
Speed: 160 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: C Kzt: NA
Des Ld: 40.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Building Code:
Soffit: 0.00
BCDL: 5.0 psf
FBC 7th Ed. 2020 Res.
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Rep Fee: Yes
Loc. from endwall: not in 9.00 ft
FT/RT:10(0)/10(10)
GCpi: 0.18
Plate Type(s):
Wind Duration: 1.60
1A tA,rC
Lumber
Top chord: 2x4 SP M-30; T2 2x4 SP #2;
Bot chord: 2x4 SP M-30;
Webs: 2x4 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 9.00 19.00
BC 89 0.15 27.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
28'
9'
SEAT PLATE REQ.
H
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
VERT(LL): 0.148 D 999 360
Loc R+ / R- / Rh / Rw / L1 / RL
VERT(CL): 0.295 D 999 240
B 1196 /- /- /737 /496 /124
HORZ(LL): 0.043 F - -
F 1196 /- /- /737 /496 /-
HORZ(TL): 0.086 F - -
Wind reactions based on MWFRS
Creep Factor: 2.0
B Brg Width = 7.6 Min Req = 1.5
Max TC CSI: 0.685
F Brg Width = 7.6 Min Req = 1.5
Max BC CSI: 0.971
Bearings B & F are a rigid surface.
Max Web CSI: 0.160
Bearings B & F require a seat plate.
Weight: 112.0 Ibs
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 21.01.01A.0521.20
A - B 19 0 D - E 2126 -2384
B - C 2129 -2555 E - F 2129 -2555
C- D 2126 -2384 F- G 19 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - J 2353 -1872 1 - H 2544 -2181
J -1 2544 - 2181 H - F 2353 -1876
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - J 420 -177 D - H 501 -193
J - D 501 -193 H - E 420 -177
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (.a. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerinc
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvdnht Q 2f11fi A-1 Rnnf Tnreses - RPnrMnnlim of this Annrment, in anv form. Ls nmhihired withrnrt tha written nenNssinn of A-1 Rnnf lrn—s.
Job: Truss
CHHS10328 A03
t russ I ype uty 1 rty
HIPS 1 1
Utf/L IF rLUL 1
Seal #: 2671
T
m
1 atTs•
SEAT PLATE REQ.
H
11'
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Sid: ASCE 7-16
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 40.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to h
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP M-30;
Webs: 2x4 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 11.00 17.00
BC 84 0.15 27.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
6' 111'
=5X6
=3X4=4X6=3X8
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
ding Code:
: 7th Ed. 2020 Res.
Std: 2014
Fac: Yes
2T:10(0)/10(10)
9 Type(s):
28'
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.149 1 999 360
VERT(CL): 0.298 1 999 240
HORZ(LL): 0.045 G - -
HORZ(TL): 0.089 G -
Creep Factor. 2.0
Max TC CSI: 0.445
Max BC CSI: 0.959
Max Web CSI: 0.406
Weiaht: 124.6 Ibs
Ver: 21.01.01 A.052120
T
A
1
SEAT PLATE REQ.
H
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1196 /- /- 1742 /495 /146
G 1196 /- /- /742 /495 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
G Brg Width = 7.6 Min Req = 1.5
Bearings B & G are a rigid surface.
Bearings B & G require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 19 0 E-F 1753 -2221
B - C 2119 -2748 F - G 2120 -2746
C- D 1758 -2232 G- H 19 0
D - E 1737 -2070
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - K 2572 -1903 J -1 2067 -1452
K - J 2067 -1452 I - G 2571 -1908
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - K 475 -532 I - E 415 -79
D - K 413 -69 1- F 479 -540
D -1 164 -158
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Luele Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cn-Mlit Q 2016 A-1 Rnnf Tnhecrs — Ran dadinn of this dnmmant. in am fnrm, is nmhibited without the writtan nehmissinn of A-1 Rnof Tnhxsac.
Job: Truss Truss Type Qty Ply 09/27/2021 =
CHHS10328 I A04 I HIPS 1 1 I Seal #: 2676 ,%'_
k. ,
li
SEAT PLATE REQ.
H
13' i2' -1- 13'
=5X6 =5X6
D E
1111.5X3 =3X4=3X4=4X6 III1.5X3
28'
SEAT PLATE REQ.
H
Loading Criteria (psf)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-16
Fig: NA Ct: NA CAT: NA
PP Deflection in loc Udefl L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
Pf: NA Ce: NA
VERT(LL): 0.161 K 999 360
Lac R+ / R- / Rh / Rw / Ll / RL
B 1196 /- /- [742 /494 /168
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(CL): 0.320 K 999 240
BCDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): 0.054 G - -
G 1196 /- /- /742 /494 /-
EXP: C Kzt: NA
Des Ld. 40.00
Mean Height: 15.00 ft
HORZ(TL): 0.108 G - -
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 5.0 psf
Building Code:
Creep Factor. 2.0
B Brg Width = 7.6 Min Req = 1.5
Soffit: 0.00
BCDL: &0 psf
FBC 7th Ed. 2020 Res.
Max TC CSI: 0.676
G Brg Width = 7.6 Min Req = 1.5
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to h
TPI Std: 2014
Max BC CSI: 0.970
Bearings B & G area rigid surface.
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Re Fac: Yes
P
Max Web CSI: 0.631
Bearings B & G require a seat plate.
Loc. from endwall: not in 9.00 ft
FT/RT:10(0)/10(10)
Weight: 126.0 Ibs
Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18
Plate Type(s):
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver• 21.01 01A 052120
A - B 19 0 E - F 1383 -1945
Wind Duration: 1.60
WAVE
Lumber
B - C 1742 -2696
F - G
1742 -2696
Top chord: 2x4 SP #2;
C- D 1383 -1945
G- H
19 0
Bot chord: 2x4 SP #2;
D - E 1357 -1786
Webs: 2x4 SP #3;
Maximum Bot Chord Forces Per
Ply (Ibs)
Purlins
Chords Tens.Comp.
Chords
Tens. Comp.
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
B - M 2501 -1529
K - J
2495 -1535
Chord Spacing(in oc) Start(ft) End(ft)
M - L 2501
2495 -1-153531
J - I
2495 -1535
TC 24 13.00 15.00
L - K
I - G
2501 -1533
BC 70 0.15 27.85
Apply purlins to any chords above or below fillers
Maximum Web Forces
Per Ply (Ibs)
at 24" OC unless shown otherwise above.
Webs Tens.Comp.
Webs
Tens. Comp.
Wind
M- C 273 0
E- K
393 -201
Wind loads based on MWFRS with additional C&C
C - L 556 -840
K - F
556 -839
member design.
D - L 393 -201
F - I
273 0
Wind loading based on both gable and hip roof types.
-WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvdnht A 2016 A-1 Rnnf Tniccr_c — R.—d-Im of thic dnn—M, in env form. is nmhWOM without thn wdnrn nr rtni. Unn of A-1 Rnnf Tnr. cea.
Job:
CHHS10328
Truss
A05
Truss Type
COMN
Qty I Ply 09/27/2021
13 1 Seal #: 2638
A
v
=4:
1 375176' �
SEAT PLATE REQ.
N
ling Criteria (psf)
Wind Criteria
L: 20.00
Wind Std: ASCE 7-16
L: 10.00
Speed: 160 mph
L: 0.00
Enclosure: Closed
iL: 10.00
Risk Category: II
EXP: C Kzt: NA
Ld: 40.00
Mean Height: 15.00 ft
�CLL: 10.00
TCDL: 5.0 psf
t: 0.00
BCDL: 5.0 psf
i Duration: 1.25
MWFRS Parallel Dist: h to 2h
:ing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 100 0.15 27.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
14'
14'
D=4X4
=3X4 =3X6 =3X4
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
28'
11
m
A
rn
A2' 1
SEAT PLATE RED.
PL1
Deft/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
VERT(LL): 0.157 D 999 360
Loc R+ / R- / Rh / Rw / Ll / RL
B 1196 /- /- /739 /254 /179
VERT(CL): 0.314 D 999 240
HORZ(LL): 0.049 F - -
F 1196 /- /- [739 /254 /-
HORZ(TL): 0.097 F - -
Wind reactions based on MWFRS
Creep Factor. 2.0
B Brg Width = 7.6 Min Req = 1.5
Max TC CSI: 0.655
F Brg Width = 7.6 Min Req = 1.5
Max BC CSI: 0.987
Bearings B & F are a rigid surface.
Max Web CSI: 0.298
Bearings B & F require a seat plate.
Weight: 114.8 Ibs
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 21.01.01A.0521.20
A: B 19 0 D - E 1473 -2358
13- C 1641 -2669 E - F 1641 -2669
C- D 1473 -2357 F- G 19 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - J 2480 -1436 1- H 1676 - 871
J -1 1676 - 871 H - F 2480 -1440
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - J 475 -458 D - H 728 - 366
J - D 727 -366 H - E 475 -458
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (I.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the
Ryan Bays, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field
491231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 SL Lurie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss
Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer Is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvrinht Q 2016 A-1 Rnnf Tnrsses - Renmdurlinn of this dnai t. in anw fnrm. is nrohihitrd Wthn t thn wretnn nenniccinn of A-1 Rnof Tn
Job:
CHHS10328
Truss
A06
Truss Type
COMN
Qlly I Ply 09/27/2021
3 1 I Seal #: 2649
li
=2
14'
D=4X4
=3X4=3X6=3X8
SEAT PLATE REQ.
k 16'11-13/16"
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
NCBCLL: mob
TCDL: 5.0 psf
Building Code:
Soffit: 0.00
BCDL: 5.0 psf
FBC 7th Ed. 2020 Res.
Load Duration: 1.25
MWFRS Parallel Dist: h to 2h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 3.00 It
Rep Fac: Yes
Loc. from endwall: not in 9.00 It
FT/RT:10(0)/10(10)
GCpi: 0.18
Plate Type(s):
Wind Duration: 1.60
IWAVE
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 27.85
Apply purlins to any chords above or below fillers
at 24" CIC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
SEAT PLATE REQ.
28'
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.040 G 999 360
VERT(CL): 0.091 G 999 240
HCRZ(LL): 0.012 B - -
HCRZ(TL): 0.028 G -
Creep Factor. 2.0
Max TC CSI: 0.645
Max BC CSI: 0.830
Max Web CSI: 0.862
Weight: 120.4 lbs
VIEW Ver: 21.01.01A.0521.20
14'
SEAT PLATE REQ.
11'0-3/16"
H
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /L1 /RL
B 666 /- /-
/469 /146 /179
1 1402 /- /-
[726 1275 /-
G 407 A A
/322 /117 /-
Wind reactions based on MWFRS
B Brg Width = 7.6
Min Req = 1.5
1 Brg Width = 7.6
Min Req = 1.7
G Brg Width = 7.6
Min Req = 1.5
Bearings B, I, & G are a
rigid surface.
Bearings B, I, & G require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 19 0
E- F 484 - 264
B - C 593 -1092
F - G 204 - 277
C-D 739 -1077
G-H 19 0
D - E 486 -182
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Camp.
B - K 985 -442 J -1 174 -76
K - J 174 -76 I - G 224 -162
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - K 511 -481 1 - E 253 -188
K - D 1089 -728 1 - F 483 -547
D -1 598 -866
"WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise staled on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvdoht Q 201a A-1 Roof Tnrcae.¢ — Renrndurlinn of thk dnn —f. in —form. is ..NNW without the written nermi.,<Ion of A-1 Ronf Tnrcaec.
Job: Truss Truss Type Qty Ply 09/27/2021
CHHS10328 I A07 COMN 11 I
1 I Seal #: 2728
a
v
la-1T• -3,
12'4" 1.3'4" 112'4"
=5X13 =5X6
D E
SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ.
16'11-13/16" 11'0-3116"
1 28' 1'
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 10.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 10.00 Risk Category: II
Des Ld: 40.00 EXP: C Kzt: NA
Mean Height: 15.00 ft
NCBCLL: 10.00 TCDL: 5.0 psf
Soffit: 0.00 BCDL: 5.0 psf
Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h
Spacing: 24.0 " C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP M-30; B2 2x4 SP #2;
Webs: 2x4 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 12.33 15.67
BC 94 0.15 27.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss passed check for 20 psf additional bottom
chord live load in areas with 42"-high x 24"-wide
clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
)w Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
NA Ct: NA CAT: NA
PP Deflection in loc L/defl L/#
NA Ce: NA
VERT(LL): 0.190 M 999 360
NA Cs: NA
VERT(CL): 0.367 M 555 240
tw Duration: NA
HORZ(LL): 0.048 D - -
HORZ(TL): 0.095 D - -
Iding Code:
Creep Factor. 2.0
7th Ed. 2020 Res.
Max TC CSI: 0.5"
Std: 2014
Max BC CSI: 0.982
Fac: Yes
Max Web CSI: 0.711
RT:10(0)/10(10)
Weight: 128.8 lbs
to Type(s):
VIEW Ver: 21.01.01A.0521.20
vF
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 953 /- /-
/669 /392 /161
J 689 /- P
/472 /264 P
G 795 P P
/453 /332 P
Wind reactions based on MWFRS
B Brg Width = 7.6
Min Req = 1.5
J Brg Width = 7.6
Min Req = 1.5
G Brg Width = 7.6
Min Req = 1.5
Bearings B, J, & G are a rigid surface.
Bearings B, J, & G require
a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 19 0
E- F 782 - 924
B - C 1423 -2071
F - G 1096 -1557
C-D .941 -1172
G-H 19 0
D - E 948 -1046
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B-N 1917 -1238 K-J 1026 -617
N - M 1908 -1237 J -1 1425 - 913
M - L 1046 - 630 I - G 1431 - 912
L - K 1026 - 617
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
N-C 317 -4 E-J 479 -610
C - M 653 -937 J - F 542 -734
D-M 215 0 F-I 243 0
L - E 598 - 390
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes an this Truss Design Drawing (TDD) and the Speclalty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the content of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lucle Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnmvrinht iA 2016 A-1 Rnnf Tnrc"e-" - Rxnrndnrlinn of thin dnnrmnnt, to env In- is nmhihRed Wthmd tha "mdxn nnnniw- of A-1 Ranf Tnrcaac:
Job:
CHHS10328
v
of
in
1 .155 66• -2
Truss
A08
d7
Truss Type
COMN
SEAT PLATE REQ.
16'11-13/16"
=5X6
D
-.3X8 =3X6 014X4=3X4
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
Snow Criteria (Pg,Pf in.PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
TCDL: 5.0 psf
Soffit: 0.00
BCDL: 5.0 psf
FBC 7th Ed. 2020 Res.
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Rep Fac: Yes
Loc. from endwall: not in 9.00 ft
FT/RT:10(0)/10(10)
GCpi: 0.18
Plate Type(s):
Wind Duration: 1.60
IWAVE
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Pull
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 10.33 17.67
BC 75 0.15 27.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Qty Ply 09/27/2021
1 1 Seal #: 2723
7'4" + 10'4"
=3X4 =5X6
E F
v
A1)
SEAT PLATE REQ. SEAT PLATE REQ.
11'0-3/16"
28' i1
Defl/CSI Criteria
PP Deflection in loc Udefi L/#
VERT(LL): 0.036 C 999 360
VERT(CL): 0.076 H 999 240
HORZ(LL): 0.011 B - -
HORZ(TL): 0.028 B -
Creep Factor. 2.0
Max TC CSI: 0.642
Max BC CSI: 0.868
Max Web CSI: 0.849
Weight: 130.2 Ibs
VIEW Ver: 21.01.01A.0521.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /Ll /RL
B 693 /- /-
/497 /263 /139
K 1285 /- /-
/627 /593 /-
H 490 /- /-
/381 /135 /-
Wind reactions based on
MWFRS
B Brg Width = 7.6
Min Req = 1.5
K Brg Width = 7.6
Min Req = 1.5
H Brg Width = 7.6
Min Req = 1.5
Bearings B, K, & H are a rigid surface.
Bearings B, K, & H require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 19 0
E- F 226 . -265
B - C 810 -1205
F - G 242 - 323
C - D 502 - 739
G - H 187 - 604
D - E 524 - 654
H -1 19 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - M 1109 -662 K - J 528 -224
M - L 482 -180 J - H 546 -120
L - K 482 -180
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
C - M
433 -499
E - K
1092 -1124
D - M
343. - 84
F - J
389 - 67
M - E
949 - 835
J - G
510 - 589
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering Q.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the Ryan Bays, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fart Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1.
Convdnht 0 2016 A-1 Roof Tnreses - Reomdadinn of this domiment. in anv form, is omhibited without the watlten nermicsion of A-1 Roof T -ec.
Job:
CHHS10328
Truss Truss Type Qty Ply
B01 HIPM 1 11
09/27/2021
Seal #: 2711
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacinq: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
258# gg# 189#
i 1 + 311 f
7,i 4 4'
SEAT PLATE REQ. SEAT PLATE REQ.
11'4"
�- TO-3/8" 2'0-3/8' 2'
492# 125 125#
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2 _
C&C Dist a: 3.00 It
Loc. from endwall: not in 4.50 It
GCpi: 0.18
Wind Duration: 1.60
Special Loads
-(Lumber Dur.Fac.=1.25
/ Plate Dur.Fac. 1.25)
TC: From 61 plf at
-1.00 to
61 plf at 7.00
TC: From 31 plf at
7.00 to
31 pif at 11.33
BC: From 20 plf at
0.00 to
20 plf at 7.03
BC: From 10 plf at
7.03 to
10 plf at 11.33
TC: 258 lb Conc. Load at 7.03
TC: 189 lb Conc. Load at 9.06,11.06
BC: 492 lb Conc. Load at 7.03
BC: 125 lb Conc. Load at 9.06,11.06
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 7.00 11.33
BC 83 0.15 11.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
Snow Criteria (Pg,Pf in PSF)
Fig: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.034 F 999 360
VERT(CL): 0.068 F 999 240
HORZ(LL): 0.013 E - -
HORZ(TL): 0.026 E - -
Creep Factor: 2.0
Max TC CSI: 0.888
Max BC CSI: 0.970
Max Web CSI: 0.729
Weight: 53.2 Ibs
VIEW Ver: 21.01.01A.052120
TT
N
1l
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /LI /RL
B 856 P P P /368 /-
G 1327 /- A A /545 A
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
G Brg Width = 7.6 Min Req = 1.6
Bearings B & G are a rigid surface.
Bearings B & G require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 19 -14 C-D 11 -22
B - C 660 -1628
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - F 1482 -581 F - E 1527 -586
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - F 718 -86 D - E 252 -344
C - E 655 -1715
'*WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the [Be, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1.
rnnvdaht W 21116 A-1 Rnnf Tninnes - Renroduntion of thin damunnnt. in arm fnon. is nrohihitad withnut the written -Minn of A-1 Roof Trimes.
Job: Truss Truss Type Qty Ply 09/27/2021
CHHS10328 B02 HIPM 11 1 �._
Seal #: 2718
9' 2'4" -.I
3-15116'
1115X6(R)
SEAT PLATE REQ. SEAT PLATE REQ.
11'4"
F— 1' --
II
m -
io
A
1�
1
_oading Criteria (psf)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
rCLL: 20.00
Wind Std: ASCE 7-16
Pg: NA Ct: NA CAT: NA
PP Deflection in loc Udefl U#
Gravity Non -Gravity
rCDL: 10.00
Speed: 160 mph
Pf- NA Ce: NA
VERT(LL): 0.041 B 999 360
Loc R+ / R- / Rh / Rw / LI / RL
B 530 /- /- /387 /201 /175
3CLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(CL): 0.082 B 999 240
3CDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): 0.017 B - -
G 450 /- /- /290 /206 P
)es Ld: 40.00
C Kzt. NA
HORZ(TL): 0.033 B -
Wind reactions based on MWFRS
Building Code:
VCBCLL: 10.00
Mea
Mean Height: 15.00 ft
Creep Factor: 2.0
B Br Width = 7.6 Min Re
9 q = 1.5 -
Soffit: 0.00
TCDL: 5.0 psf
FBC 7th Ed. 2020 Res.
Max TC CSI: 0.397
G Br Width = 7.6 Min Re 1.5
9 q =
-oad Duration: 1.25
BCDL: 5.0 psf
p
MWFRS Parallel Dist: h/2 to h
TPI Std: 2014
Max BC CSI: 0.367
Bearings B & G are a rigid surface.
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Rep Fac: Yes
Max Web CSI: 0.280
Bearings B & G require a seat plate.
Loc. from endwall: not in 9.00 ft
FT/RT:10(0)/10(10)
Weight: 51.8 Ibs
Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18
Plate Type(s):
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 21.01.01A:0521.20
A - B 19 0 C - D 426 -409
B - C 382 -536
Wind Duration: 1.60
WAVE
Lumber
Top chord: 2x4 :SP 2400f-2.OE + SP M-31:;
Bot chord: 2x4 :SP 2400f-2.0E + SP M-31:;
Maximum Bot Chord Forces Per Ply (Ibs)
Webs: 2x4 SP #3;
Chords Tens.Comp. Chards Tens. Comp.
B- F 442 -484 F- E 1 -2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Maximum Web Forces Per Ply (Ibs)
Chord Spacing(in cc) Start(ft) End(ft)
Webs Tens.Comp. Webs Tens. Comp.
TC 24 .11.33
75 0 15
BC 75 .15 11.33
C - F 608 - 351 D - E 607 - 539
Apply purlins to any chords above or below fillers
F - D 736 -764
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
-WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. NI notes set out in the TDD and the practices and 4451 St. Lurie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI-1.
Cnn,ni.M Q 201e A-1 Rmf T.,--- R—duntinn of this dnnrment. in env fern. is nmhihitxd withmd the written nenni-inn of A-1 Rnnf Tnresec.
Job: Truss Truss Type
CHHS10328 I C01 I HIPM
3-IR6'
T
Qty Ply
1 1
259# gq
+ 18 i-71
- -f"- 2'7-5/8" I-�{
m1.riX4
SEAT PLATE REQ. SEAT PLATE REQ.
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 40.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Special Loads
-(Lumber Dur.Fac.=1.25 / Plate Dur.Fac. 1.25)
TC: From 61 plf at -1.00 to
61 plf at
7.00
TC: From 31 plf at 7.00 to
31 plf at
9.64
BC: From 20 plf at 0.00 to
20 plf at
7.03
BC: From 10 plf at 7.03 to
10 plf at
9.64
TC: 259 lb Conc. Load at 7.03
TC: 189 lb Conc. Load at 9.06
BC: 491 lb Conc. Load at 7.03
BC: 125 lb Conc. Load at 9.06
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 7.00 9.64
BC 82 0.15 9.64
Apply puriins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
7'03/8" 2'0-3/8°
491# 12
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.032 B 999 360
VERT(CL): 0.063 B 999 240
HORZ(LL): 0.012 B - -
HORZ(TL): 0.024 B -
Creep Factor: 2.0
Max TC CSI: 0.836
Max BC CSI: 0.966
Max Web CSI: 0.337
Weight: 44.8 Ibs
Ver: 21.01.01 A.0521.20
09/27/2021
Seal #: 2708
T T
N
f`
fflV
1 N
1
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 672 /- P P /372 P
G 1128 P P P /761 P
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
G Brg Width = 7.6 Min Req = 1.5
Bearings B & G are a rigid surface.
Bearings B & G require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 19 -14 C-D 5 -6
B - C 674 -1065
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - F 949 -594 F - E 992 -619
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - F 693 -400 D - E 139 -195
C - E 825 -1326
"WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1.
Cnnvriaht Q 201e A-1 Ronf Tnt. caa - RanrnAj 11nn M this dmunent. in am fnnn. is nrohihit"d "rith-1 thx written i-nksinn of A-1 Rnnf Tnissas.
Job: Truss Truss Type Qty Ply 09/27/2021
CHHS10328 CO2 I HIPM 11 11 I Seal #: 2690 �-
ling Criteria (psf)
_. 20.00
L: 10.00
_. 0.00
L: 10.00
Ld: 40.00
CLL: 10.00
t: 0.00
Duration: 1.25
:inq: 24.0 "
N
CQ
Cl)
1 3-15 -
SEAT PLATE REQ.
'— 1' --
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP M-30;
Bot chord: 2x6 SP #2;
Webs: 2x4 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 108 0.15 9.64
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
Left bottom chord exposed to wind.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf. NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
C t94X4
)F
SEAT PLATE REQ.
9'7-5/8"
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / Ll / RL
E 462 /- /- /483 /245 /175
HORZ(LL): 0.027 B -
F 380 /- 1- /369 /180 /-
HORZ(TL): 0.046 B -
Wind reactions based on MWFRS
Creep Factor: 2.0
E Brg Width = 7.6 Min Req = 1.5
Max TC CSI: 0.656
F Brg Width = 7.6 Min Req = 1.5
Max BC CSI: 0.995
Bearings E & F are a rigid surface.
Max Web CSI: 0.539
Bearings E & F require a seat plate.
Weight: 42.0 Ibs
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 21.01.01A.0521.20
A-B 19 0 B-C 19 -139
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 53 -78
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
C - D 345 - 233
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Foil Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Convrinht Q 2016 A-1 Roof Tni¢crtc - Ronrod-lion of thL% doniment. in anv form. Lc nmhibited without tha written n—nicdon of A-1 Roof Tni—n.
Job: Truss Truss Type
CHHS10328 I CO3 I MONO
Qty Ply 09/27/2021
3 I 1 Seal #: 2685
3-15/16"
r
SEAT PLATE REQ. SEAT PLATE REQ.
9'7-5/8"
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: .00 40
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Soffit: 0.00
BCDL: 5.0 psf
Load -Duration: 1.25
MWFRS Parallel Dist: h/2 to h
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP M-30;
Bot chord: 2x6 SP #2;
Webs: 2x4 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 103 0.15 9.64
Apply purins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
Left bottom chord exposed to wind.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.027 B -
HORZ(TL): 0.048 B -
Creep Factor: 2.0
Max TC CSI: 0.685
Max BC CSI: 0.997
Max Web CSI: 0.581
Weight: 42.0 Ibs
Ver: 21.01.01 A.0521.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /Ll /RL
E 462 P P /483 /244 /186
F 380 P P /393 /196 P
Wind reactions based on MWFRS
E Brg Width = 7.6 Min Req = 1.5
F Brg Width = 7.6 Min Req = 1.5
Bearings E & F are a rigid surface.
Bearings E & F require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 19 0 B-C 33 -128
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 41 -62
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
C - D 374 -228
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the Ryan Bays, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lurie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1.
Cnnvriaht t) 2n16 A-1 Ronf Tniesas — Renrodnntinn of thk dmirnent. in anv fnnn. is nmhibbed vrithmd tha wri tnn narmisv'nn of A-1 Ranf Tnrssx.
Job: Truss Truss Type
CHHS10328 HJ7 HIP_
Qty Ply 09/27/2021 _<
3 1 Seal #: 2655
-2#
f 138#a
2.83 v
:3X4C
=2X4(A1)B
3-1T6• A
1111.SX3
SEAT PLATE REQ.
�--- 1'5"
9'10-1/16"
257#
�__ 2'8-11/16"
1'S-1 /�- 2'9-15/16" 2'9-15l16"
20# 101 179#
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 40.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP M-30;
Webs: 2x4 SP #3;
Special Loads
-(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From -0 plf at -1.41 to
61 plf at 0.00
TC: From 2 plf at 0.00 to
2 plf at 9.84
BC: From 2 plf at 0.00 to
2 plf at 9.84
TC: -2 lb Conc. Load at 1.46
TC: 138 lb Conc. Load at 4.29
TC: 257 lb Conc. Load at 7.12
BC: 20 lb Conc. Load at 1.46
BC: 101 lb Conc. Load at 4.29
BC: 179 lb Conc. Load at 7.12
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 116 0.15 9.84
Apply purins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.029 G 999 360
VERT(CL): 0.059 G 999 240
HORZ(LL): 0.006 F - -
HORZ(TL): 0.013 F -
Creep Factor. 2.0
Max TC CSI: 0.481
Max BC CSI: 0.578
Max Web CSI: 0.425
Weight: 40.6 Ibs
VIEW Ver: 21.01.01A.0521.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / Ll / RL
H 341 /- /- P /191 P
E 367 /- P P /130 /-
D 68 /- P P /42 P
Wind reactions based on MWFRS
H Brg Width = 10.0 Min Req = 1.5
E Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing H is a rigid surface.
Bearing H requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Camp.
A-B 10 -7 C-D 33 -45
B - C 438 -1037
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-G 1004 -415 F-E 0 0
G - F 985 -416
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
G- C 237 0 C- F 438 -1036
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terns are as defined In TPI-1.
C nvrinht Q 2016 A-1 Rnnf Tn - - Reomdunlinn of thie d-ment. in anv form. K omhihffed without the written ne,nniccinn of A-1 Rmf Tnrcce-c.
Job: Ifuss Iruss type
CHHS10328 HJ7P HIP_
city I Ply 09/27/2021
1 1 Seal #: 2705
a1T6•
-2#
SEAT PLATE REQ.
138#+ 257#
_ 2'8-11/16" �{
1'5" 1 910-1/16"
1'5-1/�-- - --i 2'9-15/16" 2'9-15/16" -- j
20# 101 179#
ling Criteria (psf)
Wind Criteria
L: 20.00
Wind Std: ASCE 7-16
L: 10.00
Speed: 160 mph
L: 0.00
Enclosure: Closed
,L: 10.00
Risk Category: II
EXP: C Kzt: NA
Ld- 40.00
Mean Height: 15.00 ft
CLL: 10.00
TCDL: 5.0 psf
t: 0.00
BCDL: 5.0 psf
I Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
;ing: 24.0 "
C&C Dist a: 3.00 It
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Special Loads
-(Lumber Dur.Fac.=1.25 / Plate Dur.Fac =1.25)
TC: From -0 plf at -1.41 to
61 plf at 0.00
TC: From 2 plf at 0.00 to
2 plf at 9.84
BC: From 2 plf at 0.00 to
2 plf at 9.84
TC: -2 lb Conc. Load at 1.46
TC: 138 lb Conc. Load at 4.29
TC: 257 lb Conc. Load at 7.12
BC: 20 lb Conc. Load at 1.46
BC: 101 lb Conc. Load at 4.29
BC: 179 lb Conc. Load at 7.12
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 74 0.15 9.84
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc L/defi L/#
VERT(LL): -0.046 G 999 360
VERT(CL): 0.064 G 999 240
HORZ(LL): -0.011 F - -
HORZ(TL): 0.015 F - -
Creep Factor. 2.0
Max TC CSI: 0.487
Max BC CSI: 0.969
Max Web CSI: 0.425
Weiaht: 40.6 Ibs
Ver: 21.01.01 A.0521.20
C
TT
M
N
ll
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / LI / RL
H 341 /- P P /259 P
E 366 P P /- /274 /-
D 69 P P P /45 P
Wind reactions based on MWFRS
H Brg Width = 10.0 Min Req = 1.5
E Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing H is a rigid surface.
Bearing H requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 10 -7 C-D 31 -45
B - C 780 -1038
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-G 1005.-748 F-E 0 0
G - F 985 -732
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
G - C 240 -195 C - F 770 -1037
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TOD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Ryan Bays, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
491231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lurie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Onnvriaht Q 2016 A-1 Rmf Tnrc _c - Ranmfurlinn of thin dmunent. in anv fnnn. is ninhiNded without thx wriltnn navnicdnn of A-1 Rmf Tn-
Job:
CHHS10328
Truss
J1
Truss Type
JACK
Qty I Ply
6 1
09/27/2021
Seal #: 2650
�c
ling Criteria (psf)
L: 20.00
L: 10.00
L: 0.00
IL: 10.00
Ld: 40.00
iCLL: 10.00
t: 0.00
i Duration: 1.25
:ing: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
3-15//116" A
i Criteria
I Std: ASCE 7-16
A: 160 mph
sure: Closed
Category: II
C Kzt: NA
'I Height: 15.00 ft
L: 5.0 psf
L: 5.0 psf
=RS Parallel Dist: 0 to h/2
Dist a: 3.00 ft
from endwall: Any
GCpi: 0.18
1 Duration: 1.60
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 10 0.15 1.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
12
4 �
2X4(A1) B
SEAT PLATE REQ.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
I/CSI Criteria
Deflection in loc Udefi U#
2T(LL): NA
:ZT(CL): NA
RZ(LL): 0.000 D - -
RZ(TL): 0.000 C - -
ep Factor. 2.0
(TC CSI: 0.189
( BC CSI: 0.022
( Web CSI: 0.000
ight: 5.6 Ibs
Ve r: 21.01.01 A.0521.20
♦ Maximum Reactions (Ibs)
Gravity
Loc R+ / R- / Rh
Non -Gravity
/Rw /U /RL
B 155 /- /- /147 /95 /32
D 10 /0 /- /15 /10 /-
C - /-12 /- /26 /25 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Camp.
A-B 19 0 B-C 21 -9
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
•'WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engtneedng (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
CCnvrinht Q 2016 A-1 RonfTnre ¢—Re—ch,ntinn of this dnannent. in anv In— is nmhihitad vrilhnut the written—issinn of A-1 RnnfTnisses.
Job:
CHHS10328
1 russ
J1P
I russ I ype
JACK
city Pry
2 1
09/2 f/2021
Seal #: 2702
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00 '
Des Ld: 40.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
SDacina: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
3-15 1/ 6" A
nd Criteria
nd Std: ASCE 7-16
eed: 160 mph
closure: Closed
;k Category: II
P: C Kzt: NA
an Height: 15.00 ft
DL: 5.0 psf
:DL: 5.0 psf
VFRS Parallel Dist: 0 to h/2
.0 Dist a: 3.00 ft
;. from endwall: Any
GCpi: 0.18
nd Duration: 1.60
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc)- Start(ft) End(ft)
BC 10 0.15 1.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Left bottom chord exposed to wind.
12
4 �
2X4(A1) B
C
--m
7-15 .
11-11/16"
D
SEAT PLATE REQ.
3w Criteria (Pg,Pf in PSF)
NA Ct: NA CAT: NA
NA Ce: NA
NA Cs: NA
)w Duration: NA
Iding Code:
7th Ed. 2020 Res.
Std: 2014
t Fac: Yes
RT:10(0)/10(10)
e Type(s):
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.000 D -
HORZ(TL): 0.000 C -
Creep Factor. 2.0
Max TC CSI: 0.189
Max BC CSI: 0.023
Max Web CSI: 0.000
Weight: 5.6 Ibs
VIEW Ver: 21.01.01A.0521.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /L1 !RL
B 155 /- A /159 /107 /32
D 10 /0 A /8 !- /-
C - /-12 /- /20 /21 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 19 0 B-C 19 -8
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"). GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (rDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss. Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lurie Blvd, Suite 201
guidelines of the Building Component Safety Information (BBC[) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1.
Cnmvrinht Q 2016 A-1 Rnnf TnLG50.Q — R—nd. 1- of this dnarment. in anv fnrm. is nmhihited withmd thn writtm nn n c Inn of A-1 Rmf Tnresrs.
Job:
CHHS10328
Truss Truss Type Qty Ply 09/27/2021 _-
J3 I JACK 16 I 1 I Seal #: 2647 A10-
ling Criteria (psf)
_. 20.00
L: 10.00
_. 0.00
L: 10.00
Ld: 40.00
CLL: 10.00
t: 0.00
I Duration: 1.25
:ina: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
3-15 [16"
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 34 0.15 3.00
Apply puriins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
12
4
SEAT PLATE REQ.
3'
C
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Pg: NA Ct: NA CAT: NA
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
Pf: NA Ce: NA
VERT(LL): NA
Loc R+ / R- / Rh / Rw / U / RL
B 203 /- /- /167 /80 /67
Lu: NA Cs: NA
VERT(CL): NA
Snow Duration: NA
HORZ(LL): 0.001 B -
D 51 !- /- /28 P /-
HORZ(TL): 0.002 B -
C 69 P /- /43 /52 P
Building Code:
Creep Factor. 2.0
Wind reactions based on MWFRS
FBC 7th Ed. 2020 Res.
Max TC CSI: 0.191
B Brg Width = 7.6 Min Req = 1.5
TPI Std: 2014
Max BC CSI: 0.100'
D Brg Width = 1.5 Min Req = -
Rep Fac: Yes
Max Web CSI: 0.000
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
FT/RT:10(0)/10(10)
Weight: 11.2 Ibs
Bearing B requires a seat plate.
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
WAVE
VIEW Ver: 21.01.01A.0521.20
Chords Tens.Comp. Chords Tens. Comp.
A-B 19 0 B-C 22 -72
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field # 91231
use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer Is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cn vnnht ,t) 2n1 a A-1 Ronf Tmsses — Renroduntinn of this dnniment. in anv fnnn. is nmhihited wilhout the written nannissinn of A-1 Ronf Tni eec
Job:
CHHS10328
Truss Truss Type Qty Ply 09/27/2021
J3P JACK 2 I 1 I Seal #: 2699
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 34 0.15 3.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Left bottom chord exposed to wind.
12
4 F-,�
SEAT PLATE REQ.
3'
C
T
co
LO
I
M
r
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Pg: NA Ct: NA CAT: NA
PP Deflection in loc Udefl U#
Gravity. Non -Gravity
Pf: NA Ce: NA
VERT(LL): NA
Loc R+ / R- / Rh ! Rw / U / RL
B 203 /- /- /209 /119 /67
Lu: NA Cs: NA
VERT(CL): NA
Snow Duration: NA
HORZ(LL): 0.001 B - -
D 51 /- /- f79 /42 /-
HORZ(TL): 0.002 B - -
C 69 /- /- /49 /50 b
Building Code:
Creep Factor: 2.0
Wind reactions based on MWFRS
FBC 7th Ed. 2020 Res.
Max TC CSI: 0.191
B Brg Width = 7.6 Min Req = 1.5
TPI Std: 2014
Max BC CSI: 0.097
D Brg Width = 1.5 Min Req = -
Rep Fac: Yes
Max Web CSI: 0.000
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
FT/RT:10(0)/10(10)
Weight: 11.2 Ibs
Bearing B requires a seat plate.
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
WAVE
VIEW Ver: 21.01.01A.0521.20
Chords Tens.Comp. Chords Tens. Camp.
A -B 19 0 B-C 22 -74
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
**WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Crnvdrht*201a A-1 Rmf Tmcses— Renmdudion of this darnrment. in anv from. is nmhibhed without the written nermissirn of A-1 Rrnf Tn, -c.
Job: Truss Truss Type Qty Ply 09/27/2021
CHHS10328 J5 JACK 6 1 Seal #: 2644 �=
3-15 16" i
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld- 40. 00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
SDacina: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
11 C
SEAT PLATE REQ.
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: 11
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 58 0.15 5.00
Apply puriins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
51
Defl/CSI Criteria
PP Deflection in loc Udefl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.006 B -
HORZ(TL): 0.011 B -
Creep Factor. 2.0
Max TC CSI: 0.455
Max BC CSI: 0.275
Max Web CSI: 0.000
Weight: 16.8 Ibs
Ver: 21.01.01 A.0521.20
fi
Xo
to
T
i1
T
co
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- ! Rh / Rw / LI / RL
B 278 /- /- /216 /104 /103
D 90 /- /- /52 /- /-
C 129 /- /- /83 /96 /-
Wind reactions based on MWFRS
B Brig Width = 7.6 Min Req = 1.5
D Brg Width =1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 19 0 B-C 41 -94
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C nvrinht a 201E A-1 Roof Tnrecr_c — R—Mnotmn of this doormen. in anv form. is nmhibitM without the written nermisclnn of A-1 Roof Tnmes.
Job: Truss Truss Type
CHHS10328 I J5P JACK
Uty I-ly UV/Z11ZUZ1
2 1 Seal #: 2696
J
3-15 16" i
17
SEAT PLATE REQ.
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
TCDL: 5.0 psf
Soffit: 0.00
BCDL: 5.0 psf
FBC 7th Ed. 2020 Res.
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Rep Fac: Yes
Loc. from endwall: not in 4.50 ft
FT/RT:10(0)/10(10)
GCpi: 0.18
Plate Type(s):
Wind Duration: 1.60
WAVE
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 58 0.15 5.00
Apply purlins to any chords above or below fillers
at 24" CC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Left bottom chord exposed to wind.
C
51 J
Defl/CSI Criteria
PP Deflection in loc Udefl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.006 B - -
HORZ(TL): 0.011 B - -
Creep Factor. 2.0
Max TC CSI: 0.476
Max BC CSI: 0.306
Max Web CSI: 0.000
Weiaht: 16.8 Ibs
EW Ver: 21.01.01A.0521.20
T
to
LO
11
T
i
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 278 /- /- /289 /155 /103
D 90 P /- /145 /79 /-
C 129 /- /- /93 /92 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 19 0 B-C 41 -99
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TOD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Ryan Bays, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 91231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C ovrinht W 2016 A-1 Ronf Tn4 -- R.—cludian of this d—iment. in nnv fnnn. Ls nrohihited without the written nlWnn of A-1 Ronf Tri—,
Job: Truss Truss Type Qty Ply 09/27/2021
CHHS10328 R I EJAC 111 I
1
x ', r I Seal #: 2641
A_
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
SEAT PLATE REQ.
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18.
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP M-30;
Bot chord: 2x4 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
71
Defl/CSI Criteria
PP Deflection in loc Udefi U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.015 B -
HORZ(TL): 0.029 B -
Creep Factor. 2.0
Max TIC CSI: 0.561
Max BC CSI: 0.588
Max Web CSI: 0.000
Weight: 22.4 Ibs
VIEW Ver: 21.01.01A.0521.20
C
TT
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 357 /- /- /269 /130 /139
D 125 /- /- /73 /- /-
C 189 /- /- /123 /140 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 19 0 B-C 60 -137
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 491231
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
r—naht Q 2016 A-1 Roof Tnlsses — Renrndnrlinn of this dnarmont. in anv form. is—hihited Wthmd the written nennicsinn of A-1 Roof Tnisses.
Job: Truss Truss Type Qty Ply
CHHS10328 I RP I EJAC 12 1
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.11 "
SEAT PLATE REQ.
1rmim
71
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 It
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP M-30;
Bot chord: 2x4 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 7.00
Apply purlins to any chords above or below fillers
at 24" CC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Left bottom chord exposed to wind.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf. NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.017 B -
HORZ(TL): 0.029 B -
Creep Factor. 2.0
Max TC CSI: 0.589
Max BC CSI: 0.669
Max Web CSI: 0.000
Weight: 22.4 Ibs
VIEW Ver: 21.01.01A.0521.20
09/27/2021
Seal #: 2693 v
C
T
CD
ti
1
T
co
1
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /Ll /RL
B 357 /- /- /373 /193 /139
D 125 A /- /205 /113 /-
C 189 /- A /138 /135 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 19 0 B-C 60 -145
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Ryan Bays, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field
# 91231
use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
FortPierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Com iaht Q 2m1e A-1 Rmf Tnrcv_e — Ranmdiidinn of thie dwinnent. in am fnrm. k nmhihhpd mthm! the written nermWginn of A-1 Rmf Tniecac.
10/2$/2020 HIP/ KING JACK (TYPICAL) STDL 01.0
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
(772)409-1010
ATTACH END JACKS USING (4)
0.131" O TOE NAILS'ATTOP
CHORD & (3) 0.131" O TOE
NAILS AT BOTTOM CHORD.
ATTACH KING JACK USING
(3) 0.131" 0 TOE NAILS AT
TOP CHORD & BOTTOM
CHORD.
ATTACH CORNER JACKS USING
(2) 0.131" 0 TOE NAILS AT TOP &
BOTTOM CHORDS (TYP).
CORNERSET GENERAL SPECIFICATIONS:
MAX LOAD: 55 PSF ROOF LOAD, 175 MPH, ASCE 7-16, EXP. B & C, UP TO 60'
MEAN ROOF HEIGHT & EXPOSURE D UP TO 30' MEAN ROOF HEIGHT.
Ryan Bays, P.E.
# 91231
4451 St Lucie Blvd, Suite 201
Fort Pierce, FL 34946
5/28/2020 HIP/ KING JACK (HVHZ) STUL b2.2
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL. 34946
(772)409-1010
ATTACH KING & END JACK
WITH (1) THJA26 HANGER
OR EQUIVALENT AT
BOTTOM CHORD
ATTACH KING & END JACKS
WITH (1) LSTA12 TWIST STRAP
AT TOP CHORD WITH (10) 1 Od
NAILS PER STRAP (MIN.) & (3)
0.131" 0 TOE NAILS.
ATTACH CORNER JACKS &
STD. JACKS WITH (1) LSTA12
TWIST STRAP AT TOP CHORD
& BOTTOM CHORD WITH (10)
1 Od NAILS PER STRAP
MINIMUM (TYP).
HIGH VELOCITY HURRICANE ZONE CORNERSET SPECIFICATIONS:
MAX LOAD: 55 PSF ROOF LOAD, 175 MPH, ASCE 7-16, EXP. B & C, UP TO 60'
MEAN ROOF HEIGHT & EXPOSURE D UP TO 30' MEAN ROOF HEIGHT.
NOTE: IN ADDITION TO STRAPPING TOE- NAIL
BOTH CHORDS OF CORNER JACKS TO CARRYING
MEMBER PER THE FOLLOWING SCHEDULE:
• 2X4: (2) 0.131" 0 TOE NAILS
• 2X6: (3) 0.131" O TOE NAILS
LSTA12 TWIST STRAP WITH 1 OD NAILS,
MIN. (10). SEE MFR'S
RECOMMENDED CONNECTION.
HIP, OR KING JACK (TYP.)
JACK, OR CORNER JACK (TYP.)
IMPORTANT NOTE:
CONNECTION DESIGNED IN ACCORDANCE WITH FBC 2321.6-
2321.7 PROVIDING METAL STRAPPING (FLORIDA APPROVED
PRODUCT) TO RESIST MIN. 700LB UPLIFT AT ALL CONNECTIONS
IN HIGH VELOCITY HURRICANE ZONE.
Ryan Bays, P.E.
# 91231
4451 St Lucie Blvd, Suite 201
Fart Pierce, FL 34946
v iv
v FEBRUARY 17, 2017 ALTERNATE GABLE END BRACING DETAIL STDTL03
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
rrzsos-1o10
ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD
1'-3'MAX.
DIAG. BRACE
AT 1/3 POINTS
IF NEEDED
IT IS �THE'RESPONSIBILITY OF THE BLDG.
DESIGNER OR THE PROJECT ENGINEER/ARCHITECT
TO DESIGN THE CEILING DIAPHRAGM AND ITS
ATTACHMENT TO THE TRUSSES TO RESIST ALL
OUT OF PLANE LOADS THAT MAY RESULT FROM
THE BRACING OF THE GABLE ENDS.
HORIZONTAL BRACE
(SEE SECTION A -A)
TRUSSSES III
24' O.C.
2X6 DIAGONAL BRACE SPACED 4B'
O.C. ATTACHED TO VERTICAL WITH
(4) - 16d NAILS, AND ATTACHED TO
BLOCKING WITH (5) - 10d COMMONS.
NAIL DIAGONAL BRACE TO
PURLIN WITH TWO 16d NAILS.
2X4 PURLIN FASTENED TO FOUR
TRUSSES WITH (2) - 16d NAILS
EACH. FASTEN PURLIN TO BLOCKING
W/ (2) - 16d NAILS (MINJ.
' PROVIDE 2X4 BLOCKING BETWEEN
THE TRUSSES SUPPORTING THE
\BRACE AND THE TWO TRUSSES ON
\ EITHER SIDE AS NOTED. TOENAIL
BLOCKING TO TRUSSES WITH (2) -
10d NAILS AT EACH END. ATTACH
DIAGONAL BRACE TO BLOCKING WITH
(5) - 10d COMMON WIRE NAILS.
END WALL
CEILING SHEATHING
BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES'
STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED:
METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE
OF THE STRUCTURAL GABLE AND FASTEN PER THE
FOLLOWING NAIL SCHEDULE.
METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL
MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING
NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG
SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL
NAILING SCHEDULE:
- FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE
7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131'
X 3') NAILS SPACED 6' O.C.
- FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-98, 02' 05), 150
MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d
(.131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM).
MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI
BRACING METHODS SHOWN ON PAGE 1 ARE VALID
AND ARE TO BE FASTENED TO THE SCABS OR
VERTICAL STUDS OF THE STANDARD GABLE TRUSS
ON THE INTERIOR SIDE OF THE STRUCTURE.
UKAL
TRUSS
ZTI In
STRUCTURAL / AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING
GABLE TRUSS / MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF
THE BOTTOM CHORD'TO RESIST ALL OUT OF PLANE LOADS.
THE BRACING SHOWN IN THIS DETAIL IS FOR
VERTICAL/STUDS ONLY.
NOTE: THIS DETAIL IS TO BE USED ONLY FOR
STRUCTURAL GABLES WITH INLAYED /
STUDS. TRUSSES WITHOUT INLAYED
STUDS ARE NOT ADDRESSED HERE.
STANDARD GABLE /
TRUSS
Ryan Bays, P.E.
# 91231
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
12/23/19 PIGGY -BACK TRUSS STDTLb4 Al
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34945
772-409-1010
PIGGY -BACK DETAIL (TYPICAL)
180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-16 PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
OR...
160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-16 PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
IMPORTANT NOTE:
TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY
BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL
PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY
RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS.
MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C.
DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA,
STEEPLE, CHIMNEY OR DRAG STRUT LOADS.
**REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE
TRUSS SPECIFICATIONS **
PIGGY -BACK TRUSS. (REFER
TO ACTUAL TRUSS DESIGN
DRAWINGS FOR ADDITIONAL
INFORMATION.)
2'-0"
MAX
OPTION NO. 1 - TEE-LOK
3" x 8" TEE-LOK MULTI -USE CONNECTION PLATES SPACED
AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO
PIGGY -BACK TRUSS AT 4'-0" O.C. STAGGERED FROM
EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH
6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE
MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8"
TEE-LOK MULTI -USE CONNECTION PLATE (MINIMUM OF 2
PLATES).
OPTION NO.2 - APA RATED GUSSET:
8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS
EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d
COMMON (0.113" x 2") NAILS PER GUSSET: 4 (EACH) AT
CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP
CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C.
FRONT TO BACK FACES. MINIMUM TWO (2 EA.)
CONNECTIONS AT EACH TRUSS.
OPTION NO.3 - 2X4 VERTICAL WOOD SCAB:
2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE.
ATTACH AT 8'-0" O.C. w/6 (EACH) 1 Od BOX NAILS (0.128"
x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND
3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE
STAGGERED 4'-0" O.C. FRONT TO BACK FACES.
MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS.
OPTION #1: TEE-LOK MULTI -USE
CONNECTION PLATE.
OPTION #2: APA RATED GUSSET.
OPTION #3: 2X4 VERT. SCAB.
ATTACH EACH PURLIN TO TOP
CHORD OF BASE TRUSS. PURLIN
& CONNECTIONS BY OTHERS.
BASE TRUSS. (REFER TO TRUSS
DESIGN DRAWINGS FOR
ADDITIONAL INFORMATION.)
PURLINS SPACED ACCORDING
TO MAX. SPACING OF TOP
CHORD OF BASE TRUSS.
SPACING IS NOT TO EXCEED 24"
O.C. & PURLINS TO BE LOCATED
AT JOINT OF EACH BASE TRUSS.
** IMPORTANT NOTE **
THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES
SPACED AT 24" O.C. OR LESS.
Ryan Bays, P.E.
4 91231
4451 St Lucie Blvd, Suite 201
Fort Pierce, FL 34946
`i 2%23719 PIGGY -BACK TRUSS (2-PLY BASE TRUSS) STDTL04.2
A-1 ROOF TRUSSES
4461 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
PIGGY -BACK DETAIL (TYPICAL)
180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-16 PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
OR...
160 MPH,WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-16 PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
IMPORTANT NOTE:
TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY
BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL
PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY
RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS.
MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C.
DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA,
STEEPLE, CHIMNEY OR DRAG STRUT LOADS.
"REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE
TRUSS SPECIFICATIONS.'
PIGGY -BACK TRUSS.
ATTACH 2X4 #2 SYP SCAB
TO ONE SIDE OF THE
PIGGY -BACK W/ (0.131" X
3") NAILS @ 4" O.C. ALONG
BOTTOM CHORD.
OPTION #2: APA RATED GUSSET:
8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS
EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d
COMMON (0.113" x 2") NAILS PER GUSSET: 4 (EACH) AT
CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP
CHORD. GUSSETS MAY BE STAGGERED AT 4-0" O.C.
FRONT TO BACK FACES. MINIMUM TWO (2 EA.)
CONNECTIONS AT EACH TRUSS.
OPTION #3: 2X4 VERTICAL WOOD SCAB:
2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE.
ATTACH AT 8'-0" O.C. w/6 (EACH) 1 Od BOX NAILS (0.128"
x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND
3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE
STAGGERED 4'-0" O.C. FRONT TO BACK FACES.
MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS.
OPTION #1: TEE-LOK MULTI -USE
CONNECTION PLATE.
ATTACH EACH PURLIN TO TOP
CHORD OF BASE TRUSS. PURLIN
& CONNECTIONS BY OTHERS.
2-PLY BASE TRUSS. (REFER TO
TRUSS DESIGN DRAWINGS FOR
ADDITIONAL INFORMATION.)
PURLINS SPACED ACCORDING
TO MAX. SPACING OF TOP -
CHORD OF BASE TRUSS.
SPACING IS NOT TO EXCEED 24"
O.C. & PURLINS TO BE LOCATED
AT JOINT OF EACH BASE TRUSS.
Ryan Bays, P.E.
1191231
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
J U LY 17, 2017
TRUSSED VALLEY SET DETAIL - SHEATHED STDTL05
w
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
VALLEY TRUSS
(TYPICAL)
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6" O.C.
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 4.5" SDS25412 SIMPSON OR
EQUIVALENT.
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND
SECURE TO BASE TRUSSES AS PER DETAIL W.
5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
6. NAILING DONE PER NOS - 01.
GABLE END, COMMON
7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
TRUSS, OR GIRDER
TRUSS
DETAIL A
BASE TRUSSES
_t CNU, UUMMUN
3S, OR GIRDER TRUSS
TRUSS CRITERIA:
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-16: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6112
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
ATTACH 2X4 CONTINUOUS #2 MAX SPACING = 24" O.C. (BASE AND VALLEY)
SYP TO THE ROOF W/TWO MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
SIMPSON SDS25412 (1/4" X 4.5")
OR EQUIVALENT WOOD SCREWS
INTO EACH BASE TRUSS.
Ryan Bays, P.E.
# 91231
4451 St. Lude Blvd, Suite 201
Fort Pierce, FL 34946
i=EbROARY 5, 2018 1 TRUSSED VALLEY SET DETAIL
STDTL06
GENERAL SPECIFICATIONS:
s:
1. NAIL SIZE = 3" X 0.131" = 10d
�. 2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT.
3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL
"A
4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN
DRAWINGS.
5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT
TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING.
A-1 ROOF TRUSSES
445�7772-409-11010
T. U1CIE BLVD. 6. NAILING DONE PER NDS - 01.
FORERCE, FL BLVD.
GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
ERCEFILTRUSS, OR GIRDER
TRUSS 7
SECURE
W/(
VALLEY TRUSS y II I '� II II II II ASE Tii SSES
(TYPICAL)
vL— r /-%rL— r%
(NO SHEATHING) N.T.S.
P 12
SEE DETAIL "A"
BELOW (TYP.)
GABLE END, COMMON
TRUSS, OR GIRDER
VALLEY TRUSS TRUSS
(TYPICAL)
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-16, 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6112
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
ATTACH 2X4 CONTINUOUS #2
MAX TOP CHORD TOTAL LOAD = 50 PSF
SYP TO THE ROOF W/ TWO
MAX SPACING = 24" O.C. (BASE AND VALLEY)
SIMPSON SDS25300 (1/4" X 3")
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
OR EQUIVALENT WOOD
SCREWS INTO EACH BASE
TRUSS.
Ryan Bays, RE
# 91231
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34M
J U LY 17, 2017
1 1 \V VV1.._✓ V /—% ..LLL 1 <7L_ 1 ✓L I P-%IIL
(HIGH WIND VELOCITY)
STDTL07
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34945
772-449.1010
ATTAC
WIND DESIGN PER ASCE 7-98, ASCE 7-1
WIND DESIGN PER ASCE 7-16: 170 MPI
MAX MEAN ROOF HEIGHT = 30 FEET
CATERGORY II BUILDING
EXPOSURE B OR C
WIND DURATION OF LOAD INCREASE:'
MAX TOP CHORD TOTAL LOAD = 50 PSI
MAX SPACING = 24" O.C. (BASE AND VA
SUPPORTING TRUSSES DIRECTLY UNG— ,, 11— . I
DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' 10" ON AFFECTED
TOP CHORDS.
NOTES:
1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES.
2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER.
NON -BEVELED
BOTTOM CHORD
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE APPLIED
TO EITHER FACE.
CLIP MAY BE APPLIED
TO THIS FACE UP TO A
MAXIMUM 6/12 PITCH
NON -BEVELED
BOTTOM CHORD
000
CLIP MUST BE APPLIED TO J
THIS FACE WHEN PITCH
EXCEEDS 6/12 (MAXIMUM
12/12 PITCH) Rya , P.E.
4912
4451 St. Lucie Blvd, Sure
Fort Pierce, FL 34946
FEBRUARY 17, 2017 1 STANDARD GABLE END DETAIL I STDTL08
i
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TYPICAL 2X4 L-BRACE
NAILED TO 2X4 VERTICALS
W/lOd NAILS, 6' O.C.
VER7
STUD
SECTION B-B
TRUSS GEOMETRY AND CONDITIONS
SHOWN ARE FOR ILLUSTRATION ONLY.
DIAGONAL BRACE 4' - 0' D.C. MAX.
SEE INDIVIDUAL ENGINEERING DRAWINGS
FOR TRUSS DESIGN CRITERIA.
12
Q VARIES TO COMMON TRUSS
3X4 =
* DIAGONAL BRACING ** L - BRACING REFER
REFER TO SECTION A -A TO SECTION B-B 24' MAX.
NOTE:
1. MINIMUM GRADE' OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS.
2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO
BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT.
3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG.
ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF
SYSTEM.
4. 'L' BRACES SPECIFIED ARE TO. BE FULL LENGTH, SPF OR.SP #3 OR
BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C.
S. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM
AT4'-0'D.C.
6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN
WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE ,LOCATED AT
THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE
STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A)
7 GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240
VERTICAL
2X6 SP OR SPF
STUDP2X4
#2 DIAGONAL
BRACE
(4) - 16d
NAILS16d
NAILS
SPACED E' O.C.
(2) 10d NAILSINTO
2X62X6
SP OR
SPF #2
2X4 SP OR
SPF #2LHORIZONTAL
NAILED TO
RTICALS
SECTION A -A
W/(4) - 10d NAILS
PROVIDE 2X4 BLOCKING BETWEEN
THE FIRST TWO TRUSSES AS NOTED.
TOENAIL BLOCKING TO TRUSSES
WITH (2) - 10d NAILS AT EACH END.
ATTACH,OIAGONAL BRACE TO
BLOCKING WITH (5) - 10d NAILS
(4) Bd NAILS MINIMUM,
PLYWOOD SHEATHING TO
2X4 STD SPF BLOCK
B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. DIAL. BRACE
S. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS
TRUSSES. IF NEEDED
10. 10d AND 16d NAILS ARE 0131'X3.0' AND 0131'X3.5' COMMON WIRE NAILS
RESPECTIVELY.
11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12
BY SPIB/ALSC.
MINIMUM STUD
SIZE SPECIES
AND GRADE
STUD
SPACING
WITHOUT
BRACE
2X4
L - BRACE
DIAGONAL
BRACE
(2) DIAGONAL
BRACES AT
1/3 POINTS
MAXIMUM STUD LENGTH
2X4SP,#31STUD
12"O.C.
3-8-10
5-6-11
6-6-11
11-1-13
2X4 SP 431 STUD
16" O.C.
3-3-10
4-9-12
6-6-11
9-10-15
2X4 SP #31 STUD
24" O:C.
2-8-6
3-11-3
54-12
8-1-2
2X4 SP #2
12" O.C.
3-10-15
5-6-11
6-6-11
11-8-14
2X4 SP #2
16" O.C.
3-6-11
4-9-12
6-6-11
10-8.0
2X4 SP #2
24" O.C.
1 3-1-4 1
3-11-3
1 6-2-9
1 9-3.13
DIAGONAL BRACES OVER 6' - 3- REQUIRE A 2X4 T-BRACE ATTACHED TO ONE
EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO
BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE
WITH 10d NAILS G' D.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER
SOX OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2.
ROOF
SHEATHING'
NAILS lOd
TRUSSES @ 24' O.C.
2X6 DIAGONAL BRACE
SPACED 48. O.C. ATTACHED
TO VERTICAL WITH (4) -
16d NAILS, AND ATTACHED
TO BLOCKING WITH (5) -
10d NAILS.
HORIZONTAL BRACE
(SEE SECTION A -A)
END WALL
Ryan Bays, P.E.
# 91231
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
MAX MEAN ROOF HEIGHT = 30 FEET
EXPOSURE B OR C
ASCE 7-16190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING.
DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS.
-BRAC
DETA
r I T WIITH 2XIBRACEEON Y IL
FEBRUARY 17, 2017 STDTL09 �
i
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
gOTES:
r—BRACING / I —BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACIN[
IS IMPRACTICAL. T—BRACE / I —BRACE MUST COVER SOX OF WEB LENGTH.
THIS DETAIL NOT TO BE USED TO CONVERT T—BRACE / I —BRACE WEBS TC
:ONTINUOUS LATERAL BRACED WEBS.
NAILING PATTERN
T-BRACE SIZE
NAIL SIZE
NAIL SPACING
2X4 OR 2X6 OR 2X8
10d
6' O.C.
NOTE: NAIL ALONG ENTIRE LENGTH OF T—BRACE / ]—BRACE (ON
TWO—PLY TRUSSES NAIL TO BOTH PLIES)
NAILS
BRACE
SIZE FOR ONE -PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T—BRACE
2X4 1—BRACE
2X6
2X6 T—BRACE
2X6 I —BRACE
2X8
2X8 T—BRACE
2X8 I —BRACE
BRACE
SIZE FOR TWO-PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T—BRACE
2X4 I —BRACE
2X6
2X6 T—BRACE
2X6 I —BRACE
2X8
2X8 T—BRACE
2X8 I —BRACE
T—BRACE / I —BRACE MUST BE SAME SPECIES
AND GRADE (OR BETTER) AS WEB MEMBER.
NAILS
WEB
NAILS
NAILS
WEB
I -BRACE T-BRACE
Ryan Bays, P.E.
# 91231
4451 St. Lucie Blvd, Suite 201
SECTION DETAILS Fort Pierce, FL34945
r FEBROARY 17, 2017
LATERAL BRACING RECOMMENDATIONS I STDTL10
i
A44=
A 1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS,
2XG 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET
ALONG A FLOOR TRUSS.
NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE
TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY
OF THE METHODS ILLUSTRATED BELOW.
NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE
BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE, BOTTOM CHORD, IS CONTINUOUS
FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY
CONNECTED, BY OTHERS, AT THE ENDS.
USE METAL FRAMING
ANCHOR TO ATTACH
TO TOP CHORD
BLOCKING BEHIND THE VERTICAL
WEB IS RECOMMENDED WHILE
NAILING THE STRONGBACK
INSERT WOOD SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (00 NOT
ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS)
WEB WITH (3) — 10d SCAB WITH (3) IOd
NAILS (0.131' X 3') NAILS (0.131' X 7). r ATTACH TO VERTICAL
NAILS (01313WITH )X 3')
ATTACH 2X4 VERTICAL
TO FACE OF TRUSS.
FASTEN TO TOP AND
BOTTOM CHORD WITH
(2) — 10d NAILS (0.131'
X 3') IN EACH CHORD
USE METAL FRAMING ATTACH TO VERTICAL L ATTACH TO VERTICAL L
ANCHOR TO ATTACH WEB WITH (3) — 10d SCAB WITH (3) — 10d
TO BOTTOM CHORD NAILS (0131' X 3') NAILS (0.131' X 3')
TRUSS 2X6 4' — 0' WALL
STRONGBACK (TYPICAL SPLICE) (BY OTHERS)
ATTACH TO CHORD
WITH (2) #12 X 3' "
WOOD SCREWS
(0.216' DIA.)
INSERT SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (00 NOT
USE DRYWALL TYPE SCREWS)
THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT,
DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' — 0' LONG SCAB
CENTERED ON THE SPLICE AND JOINED WITH (12) — 10d NAILS (0.131' X 3')
EQUALLY SPACED.
BLOCKING
(BY OTHERS)
ALTERNATE METHOD OF SPLICING: Ryan Bays, P.E.
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' — 0' AND FASTEN WITH (12) — #91231
10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY 4451 St Lucie Blvd, Suite 201
WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). Fort Pierce, FL 34946
FEBRUARY 17, 2017 LATERAL TOE -NAIL DETAIL STDTL11 a {
�e
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772.409-1010
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45° WITH THE MEMBER
AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN
THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS
SHOWN).
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL
BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO
SPECIES FOR MEMBERS OF DIFFERENT SPECIES.
TOE -NAIL SINGLE SHEAR VALUES
PER NOS 2001 (LB/NAIL)
DIA
SP
DF
HF
SPF
SPF-S
.131
88.0
80.6
69.9
68.4
59.7
o0
.135
93.5
85.6
74.2
72.6
63.4
.162
108.8
99.6
86.4
84.5
73.8
ri
128
74.2
67.9
58.9
57.6
50.3
c>
Z
0
.131
75.9
69.5
60.3
59.0
51.1
.14B
81.4
74.5
64.6
63.2
52.5
N
ri
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
THIS DETAIL IS ONLY APPLICABLE TO
THE THREE END DETAILS SHOWN BELOW.
VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY.
SIDE VIEW
(2X4) 3 NAILS
EXAMPLE: NEAR SIDE
(3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD
NEAR SIDE
FOR LOAD DURATION INCREASE OF 1.15: NEAR SIDE
3 (NAILS) X 84.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY
ANGLE MAY
VARY FROM
30' TO 60°
45.00'
ANGLE MAY
VARY FROM
30° TO 60°
45.00'
SIDE VIEW
(2XG) 4 NAILS
NEAR SIDE
NEAR SIDE
NEAR SIDE
NEAR SIDE
ANGLE MAY
VARY FROM
30' TO 60°
45.000
Ryan Bays, .E.
1e 91231P
4451 Lucie Blvd, Suite 201
Fort ' roe. FL 34946
FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL I STDTL12
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
THIS DETAIL SHALL BE USED FOR A CONNECTION
RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER
IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS.
TOE -NAIL WITHDRAWAL VALUES
PER NOS 2005 (LB/NAIL)
DIA.
SP
OF
HF
SPF
SPF-S
L7
.131
59
46
32
30
20
Z
O
J
.135
60
48
33
30
20
U7
.162
72
58
39
37
25
J
2
O
.128
54
42
28
27
19
F-
Z
Z
OJ
.131
55
43
29
28
19
LLI
.148
62
48
34
31
21
--I
Lo
J_
N
Q
M
Z
.120
51
39
27
26
17
0
Z
.128
49
38
26
25
17
O
J
.131
51
39
27
26
17
M
.148
1 57
44
31
28
20
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE
MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION.
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE
FOR WIND OOL OF 1.33:
3 (NAILS) X 37 (LB/NAIL) X 1.33 (DOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
FOR WIND DOL OF 1.60:
3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LBS) BUILDING
DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION.
*+�+ USE (3) TOE -NAILS ON 2X4 BEARING WALL
*+� USE (4) TOE -NAILS ON 2X6 BEARING WALL
NEAR SIDE
FAR S'
)E
TOP PLATE
OF WALL
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
IL
NAIL
3rsLP.E.
# 91231
4451 St. Lucie Blvd, Suite 201
_ Fort Pierce, FL 34946
SIDE VIEW
END VIEW
FEBRUARY 5, 2016
TYP 2x2 NAILER ATTACHMENT I STDTL13 'w
,= 2x2 NAILER ATTACHMENT
GENERAL SPECIFICATIONS
A-1 ROOF TRUSSES
FORT PIERCE,IFLB34946 MAX LOAD: 55 psf Roof Load, 170 mph, ASCE
772-409-1010
7-10, 29'-0" Mean Height, Exp. B, C or D.
lw-]:qw
Ryan Bays, P.E.
# 91231
4451 St Lucie Blvd, Suite 201
Fort Pierce, FL 34946
April 11, 2016 I TYPICAL ALTERNATE BRACING DETAIL I STDTLI4
FO EXTERIOR FLAT GIRDER TRUSS
-
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
(4) 12d
TRUSS 2411 O.C.
UPLIFT CONNECTION
(SEE ROOF TRUSS)
EXTERIOR FLAT
GIRDER
12
VARIES
(4) 12d
MAX 3011 (21-611)
2x6 #2 SP (Both Faces)
24" O.C.
SIMPSON H5
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
FEBRUARY 17, 2017 I STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND I STDT05
DAMAGED OR MISSING CHORD SPLICE PLATES
Art ROOF TRUSSES
4451 ST. LUGIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TOTAL NUMBER
OF NAILS EACH
SIDE OF BREAK
X
(INCHES)
MAXIMUM FORCE (LBS) 15% LOAD DURATION
SP
OF
SPF
HF
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
20
30
24"
1706
2559
1561
2342
1320
1980
1352
2028
26
39
30"
2194
3291
2007
3011
1697
2546
1738
2608
32
48
36"
2681
4022
2454
3681
2074
3111
2125
3187
38
57
42"
3169
4754
2900
4350
2451
3677
2511
3767
44
66
48"
3657
5485
3346
5019
2829
4243
2898
4347
s DIVIDE EQUALLY FRONT AND BACK
ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF
THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X41 THREE
ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' DIA. X 3').
STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' D.C. SPACING IN
THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE.
THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS)
THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C
`! BREAK
•10d NAILS NEAR SIDE
+lOd NAILS FAR SIDE
6' MIN
TRUSS CONFIGURATION
AND BREAK LOCATIONS
FOR ILLUSTRATIONS ONLY
THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO
THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT
AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE).
DO NOT USE REPAIR FOR JOINT SPLICES
NOTES:
1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR
DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE
TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN
THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF
SUPPORTING THE LOADS INDICATED.
2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR
AND HELD IN PLACE DURING APPLICATION OF REPAIR.
3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID Ryan Bays, P.E.
UNUSUAL SPLITTING OF THE WOOD. #91231
4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID 4451 St Lucie Blvd, Suite 201
LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. Fort Pierce, FL 34946
S. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY.
G. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS.
I. FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS
STDTL16
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34M
772-409-1010
TRUSS CRITERIA:
LOADING: 40-10-0-10
DURATION FACTOR: 115
SPACING: 24' O.C.
TOP CHORD: 2X4 OR 2X6
PITCH: 4/12 - 12/12
HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL
END BEARING CONDITION
NOTES:
1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, DF) TO ONE FACE OF TRUSS
WITH TWO ROWS OF 10d, COMMON WIRE NAILS (.14B' DIA. X 3') SPACED 6' D.C.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO
AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
2X SC
NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED
WHEN OVERHANG HAS BEEN BROKEN OFF.
IMPORTANT
THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24'
D.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD
LOADS NOT EXCEEDING 50 PSF.
TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.
REFER TO INDIVIDUAL TRUSS DESIGN
FOR PLATE SIZES AND LUMBER GRADES
Ryan Bays, P.E.
# 91231
4451 St Lucie Blvd, Suite 201
Fort Pierce, FL 34946
RE: Job CHHS10328
No.
Seq #
Truss Name
Date
37
STDL14
STD. DETAIL
9/27/21
38
STDL15
STD. DETAIL
9/27/21
39
STDL16
STD. DETAIL
9/27/21
i M 1r
Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
These truss designs rely on lumber values established by others.
Page 2 of 2