Loading...
HomeMy WebLinkAboutAPPROVED, DESIGN LOADPlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 – (772) 462-1553 Certification for Design Load Compliance Project Name: Project Address: Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: x This certification must be completed, signed, and sealed by the design professional of record. x Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) Code ϳƚŚ Edition with 20 Supplements using ASCE 7-1ϲ ϭ͘DESIGN CODE: F> Ϯ͘Structure Designed as (check one): Enclosed Partially Enclosed Open 3. Risk Category:III IIIIV Exposure Category:BC D 4. Design Wind Velocity mph ASD _LRFD End Zone Width: ft 5. Mean Roof Height ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sqft @ 15’MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: Zone 5:Garage: 7. Design Loads: Floor:PSF Roof/Dead: PSF Roof/Live:Balcony:PSF Dock: _PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided?Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Print Name Cert # & Co. Cert Auth. Signature, Date, and Seal Company Name & Address Revised ϭϬ/Ϯϭ20Ϯϭ;^^^Ϳ Karen Oxley Res - Window & Door Replacement 9650 S. Ocean Dr., Jensen Beach R-2 1 Building/Res 20 X XX 170 X 3.5 35 5 0 +53.1/57.7 +53.1/-71.2 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A NOT PART OF SCOPE N/A NOT PART OF SCOPE N/A N/A Jeffrey C. Friant, P.E. Specialty Engineering Serivces & Solutions, Inc. CA#32371 18540 126th Terrace N., Jupiter, FL 33478