Loading...
HomeMy WebLinkAboutMidway MC LetterArchitectonic Inc 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1 St. Lucie County Building Department Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982 November 16, 2021 RE: Midway Medical Center, 356 Midway Rd., Fort Pierce, FL To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed windows are incompliance with the 2020 Florida Building Code, 165 mph wind zone, exposure “C”, risk category II. Exposure “C” Multiplier for 20’ mean roof height is 1.29 Wind Zone 4 30.5 x 1.29= -39.3 Wind Zone 5 36.7 x 1.29 = -47.4 Required Design Pressures: -47.4 Product Design Pressure: -70 Product: Window Craftsman, Inc., SH 300 Vinyl Windows, FL# 15749.2 Respectfully Submitted, _________________________________ Michael Seal, AIA AR96898 Architectonic, Inc.