Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method. Project Name: TNT Builders - Seagull Model Builder Name: Street: Permit Office: St. Lucie County City, State, Zip: Port St. Lucie, FL , 34983 Permit Number: Owner: Bella Vista Contractors Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41730.6 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1497.30 ft2 b. Frame - Wood, Adjacent R=11.0 233.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Types (1843.0 sqft.) Insulation Area a. Under Attic (Vented) R=19.0 1843.00 ft 6. Conditioned floor area above grade (ft2) 1843 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(122.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: AHU, AH: AHU R ft2 6 80 a. U-Factor: Sgl, U=0.65 122.00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 35.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Heat Pump 27.0 HSPF:9.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1843.0 sgft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 1843.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits CF, Pstat Glass/Floor Area: 0.066 Total Proposed Modified Loads: 53.55 PASS Total Baseline Loads: 54.50 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by thisp Code. calculation indicates compliancefi,,``'f 1&kJo with the Florida Energy Code. PREPARED BY.QBX6 Before construction is completed DATE: 4-7- '02 this building will be inspected for compliance with Section 553.908 . herebycertify that this ddin as des d, is in com liance fY 9, p Florida Statutes. with the Florida Ener e. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE C®0 4/6/2021 6:09 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHF-GKLI51 REPORT PROJECT Title: TNT Builders - Seag User Bedrooms: 3 Address Type: Street Address Building Type: TNT Builders Conditioned Area: 1843 Lot # Owner Name: 1 Total Stories: 1 Block/Subdivision: # of Units: Worst Case: Yes PlatBook: Builder Name: St. Lucie County Rotate Angle: 90 Street: Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: Detached Whole House Fan: No City, State, Zip: Port St. Lucie , Family Type: New (From Plans) FL, 34983 New/Existing: Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1843 17324.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Bedroom 3 173 1626.2 No 0 1 1 Yes Yes Yes 2 Bedroom 2 150 1410 No 1 1 1 Yes Yes Yes 3 Hall 30 282 No 0 1 No Yes Yes 4 Bath 54 507.6 No 0 1 Yes Yes Yes 5 Laundry 64 601.6 No 1 1 No Yes Yes 6 AHU 16 150.4 No 0 1 No Yes Yes 7 Hall 40 376 No 0 1 No Yes Yes 8 Dining 100 940 No 2 1 Yes Yes Yes 9 Kitchen 170 1598 Yes 2 1 No Yes Yes 10 Family 218 2030.4 No 2 1 Yes Yes Yes 11 Bedroom 4 130 1222 No 1 1 1 Yes Yes Yes 12 Living Room 232 2180.8 No 2 1 Yes Yes Yes 13 Master Bedroom 263 2472.2 No 2 1 Yes Yes Yes 14 WIC 1 54 507.6 No 0 1 Yes Yes Yes 15 WIC 2 25 235 No 0 1 No Yes Yes 16 M Bath 126 1184.4 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Bedroom 3 29 ft 173 ftz r_ 1 0 0 2 Slab -On -Grade Edge Insulatio Bedroom 2 14 ft 150 ft' ---- 1 0 0 4/6/2021 6:09 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 3 Slab -On -Grade Edge Insulatio Hall 1 1 ft 30 ft2 e__ 1 0 0 4 Slab -On -Grade Edge Insulatio Bath 6 ft 54 ft2 1 0 0 5 Slab -On -Grade Edge Insulatio Laundry 1 ft 64 ft2 ____ 1 0 0 6Slab-On-Grade Edge Insulatio AHU 1 ft 16 ft2 1 0 0 7Slab-On-Grade Edge Insulatio Hall 2 1 ft 40 ft2 1 0 0 8 Slab -On -Grade Edge Insulatio Dining loft 100 ft2 1 0 0 9 Slab -On -Grade Edge Insulatio Kitchen 1 ft 170 ft2 ee 1 0 0 10SIab-On-Grade Edge Insulatio Family 15 ft 216 ft2 1 0 0 11SIab-On-Grade Edge Insulatio Bedroom 4 loft 130 ft2 1 0 0 12SIab-On-Grade Edge Insulatio Living Room 13 ft 232 112 1 0 0 13SIab-On-Grade Edge Insulatio Master Bedroom 30 ft 263 ft2 r_ 1 0 0 14SIab-On-Grade Edge Insulatio WIC 1 9 ft 54 ft2 1 0 0 15SIab-On-Grade Edge Insulatio WIC 2 1 ft 25 ft2 W_ 1 0 0 16SIab-On-Grade Edge Insulatio M Bath 23 ft 126 ft2 ____ 1 0 0 ROOF V Roof Gable Roof Rad Solar SA Emift Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1997 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1843 ft2 N N 4/6/2021 6:09 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 1.I FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Bedroom 3 19 Batt 173 ft2 0.1 Wood 2 Under Attic (Vented) Bedroom 2 19 Batt 150 ft2 0.1 Wood 3 Under Attic (Vented) Hall 1 19 Batt 30 ft2 0.1 Wood 4 Under Attic (Vented) Bath 19 Batt 54 112 0.1 Wood 5 Under Attic (Vented) Laundry 19 Batt 64 ft2 0.1 Wood 6 Under Attic (Vented) AHU 19 Batt 16 ft2 0.1 Wood 7 Under Attic (Vented) Hall 2 19 Batt 40 ft2 0.1 Wood 8 Under Attic (Vented) Dining 19 Batt 100 ft2 0.1 Wood 9 Under Attic (Vented) Kitchen 19 Batt 170 ft2 0.1 Wood 10 Under Attic (Vented) Family 19 Batt 216 ft2 0.1 Wood 11 Under Attic (Vented) Bedroom 4 19 Batt 130 ft2 0.1 Wood 12 Under Attic (Vented) Living Room 19 Batt 232 111:2 0.1 Wood 13 Under Attic (Vented) Master Bedroom 19 Batt 263 111:2 0.1 Wood 14 Under Attic (Vented) WIC 1 19 Batt 54 ft2 0.1 Wood 15 Under Attic (Vented) WIC 2 19 Batt 25 ft2 0.1 Wood 16 Under Attic (Vented) M Bath 19 Batt 126 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 NE=>SE Exterior Concrete Block - Int InsuBedroom 3 4.1 12 0 9 5 113.0 ft2 0 0 0.6 0 2 SE=>SW Exterior Concrete Block - Int InsuBedroom 3 4.1 1 0 9 5 9.4 ft2 0 0 0.6 0 3 NW=>NE Exterior Concrete Block - Int InsuBedroom 3 4.1 16 0 9 5 150.7 ft2 0 0 0.6 0 4 NW=>NE Exterior Concrete Block - Int InsuBedroom 2 4.1 14 0 9 5 131.8 ft2 0 0 0.6 0 5 NE=>SE Exterior Concrete Block - Int Insul Bath 4.1 6 0 9 5 56.6 ft2 0 0 0.6 0 6 NE=>SE Exterior Concrete Block - Int Insul Dining 4.1 10 0 9 5 94.2 ft2 0 0 0.6 0 7 NE=>SE Exterior Concrete Block - Int Insul Family 4.1 15 0 9 5 141.3 ft2 0 0 0.6 0 8 SW=>N Exterior Concrete Block - Int InsuBedroom 4 4.1 10 0 9 5 94.2 ft2 0 0 0.6 0 9 SW=>N Exterior Concrete Block - Int InstUiving Room 4.1 13 0 9 5 122.4 ft2 0 0 0.6 0 10 NE=>SE Exterior Concrete Block - Int InsMaster Bedro 4.1 14 0 9 5 131.8 ft2 0 0 0.6 0 11 SE=>SW Exterior Concrete Block - Int InsMaster Bedro 4.1 16 0 9 5 150.7 ft2 0 0 0.6 0 12 SE=>SW Exterior Concrete Block - Int Insul WIC 1 4.1 9 0 9 5 84.8 ft2 0 0 0.6 0 13 SE=>SW Exterior Concrete Block - Int Insul M Bath 4.1 9 0 9 5 84.8 ft2 0 0 0.6 0 14 SW=>N Exterior Concrete Block- Int Insul M Bath 4.1 14 0 9 5 131.8 ft2 0 0 0.6 0 _ 15 SW=>N Garage Frame - Wood Bedroom 2 11 12 9 4 112.0 ft2 0.23 0.6 0 16 SW=>N Garage Frame - Wood Laundry 11 8 9 4 74.7 ft2 0.23 0.6 0 _ 17 NW=>NE Garage Frame - Wood Bedroom 4 11 5 9 4 46.7 ft2 0.23 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW=>N Insulated Living Room None .39 3 6 10 20.5 ft2 2 SW=>N Insulated Laundry None .39 2 8 6 8 17.8 ft2 4/6/2021 6:09 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 !` I , 4ti FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 NW=>NE 3 Metal Low-E Single . Yes 2 NW=>NE 4 Metal Low-E Single Yes 3 NE=>SE 7 Metal Low-E Single Yes 4 SW=>NW 8 Metal Low-E Single Yes 5 SW=>NW 9 Metal Low-E Single Yes 6 NE=>SE 10 Metal Low-E Single Yes 7 SW=>NM4 Metal Low-E Single - Yes 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0.65 0.25 Y 0-.65 0.25 Y 15.0 ft2 1 ft 0 in 1 ft 4 in 15.0 ft2 1 It 0 in 1. ft 4 in 41.0 ft2 1 It 0 in 1 ft 4 in 15.0 ft2 1 ft 0 in 1 ft 4 in 15.0 ft2 1 ft 0 in 1 ft 4 in 15.0 ft2 1 ft 0 in 1 ft 4 in 6.0 ft2 1 ft 0 in 1 It 4 in None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft2 400 ft2 25 ft 9.4 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000418 2021.2 110.89 208.18 .1348 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:9 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing[ SEER: 16 35 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS -- Supply - - Return - # Location R-Value Area Location Area Leakage Type Air CFM 25 CFM25 Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 80 ft2 AHU 10 ft2 Default Leakage AHU (Default) (Default) 1 1 4/6/2021 6:09 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb HeatinJan Feb Mar Mar A r f Apr I Ma MaY Jun rj Jun Jul Jul Au[ rl Au [X] Se ]Sep Oct Oct H Nov Nov Dec HDec Ventin Jan Feb Mar [X] A r May Jun Jul Aug [) Se [X Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (VVD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 1 Default(8 lbs/sq.ft. ft2 ft 0.3 Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 lbs/sq.ft. ft2 ft 0.3 AHU Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 lbs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Family Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 4 Default(8lbs/sq.ft. ft2 ft 0.3 Living Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8lbs/sq.ft. ft2 ft 0.3 WIC 1 Default(8lbs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/s .ft. ft2 ft 0.3 M Bath 4/6/2021 6:09 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6