Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING ACCSSESORIES awall BCIS Home Log In User Registration Mot Top,cs Submit Surcharge Scats&Facts Publications Contact Us BCIS Site Map Links Search d b'p� r ( ;:_I Product Approval �,..-- USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL2847-R15 Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Lomanco Address/Phone/Email 2101 West Main St Jacksonville, AR 72076 (501)983-6163 kjelley@lomanco.com Authorized Signature Katrina Jelley kjelley@lomanco.com Technical Representative KATRINA JELLEY Address/Phone/Email 2101 West Main St Jacksonville,AR 72076-4247 (501) 982-6511 Ext6163 kjelley@lomanco.com Quality Assurance Representative KATRINA JELLEY Address/Phone/Email 2101 West Main St Jacksonville, AR 72076-4247 (501) 983-6163 kjelley@lomanco.com Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity Miami-Dade BCCO -EVL Quality Assurance Entity Miami-Dade BCCO -CER Quality Assurance Contract Expiration Date 09/04/2023 Validated By Miami-Dade BCCO-VAL Certificate of Independence Referenced Standard and Year (of Standard) Standard Year Miami-Dade TAS 100(A) 1995 Equivalence of Product Standards Certified By Approved Evaluation Entity FL2847 R15 Equiv 21032308.pdf Sections from the Code Product Approval Method Method 1 Option C Date Submitted 08/02/2021 Date Validated 08/18/2021 Date Pending FBC Approval Date Approved 08/26/2021 Summary-of-Products FL 7F Model,Number or Name Description 2847.1 Lomanco Lo-OmniRidge LOR9-4; Gun Nailable 4'Ridge Vent for 9"Cap Shingles TRI-BUILT Lo-OmnlRidge LOR9-4 Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL2847 R15 II 19121 705.pdf Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO- EVL Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: 1. Refer to applicable building codes for required FL2847 R15 AE 19121705.pdf ventilation.2. Ridge Vent shall not be installed on roof hips. 3. Ridge Vent shall not be connected at ridge intersection,nor within 12"of any side wall or roof protrusion,with a ventilation slot clearance of 12"from such obstructions.4.Ridge Vent shall not be installed on roof mean heights greater than 33 feet, �284�7. Lomanco Lo-OmniRoll LOR-30, Tli 60" Gun Nailable Shingle Over Ridge Vent(Sold as 30'roll-six BUILT Lo-OmniRoll LOR-30 60" vents are welded together.) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL2847 R15 II 19121703.pdf Approved for use outside HVHZ: Yes Verified By: Miami-Dade BCCO-EVL Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: 1. Refer to applicable building codes for required FL2847 R15 AE 19121703.pdf ventilation. 2. OmniRldge Vent shall not be Installed on roof mean heights greater than 33 feet. 2847.3 OmniRidge OR-4 4 Shingle Over Ridge Vent Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL2847 R15 II 21032308.pdf Approved for use outside HVHZ: Yes Verified By: Miami-Dade BCCO -EVL Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: 1. Refer to applicable building codes fo-required FL2847 R15 AE 21032308.pdf ventilation. 2. OmniRldge Vent shall not be Installed on roof mean heights greater than 33 feet. n n Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 phone:850-487-1824 The State o/Florida is an AA/EEO employer.j,Q{lyrioht 2007-2013 State of Florida ::Privacy Statement: Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe MIAMI-DADE COUNTY MIA�MI-f]ADE PRODUCT CONTROL SECTION ►S:E 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/cconomv Lomanco,Inc. 2101 West Main Street Jacksonville,AR 72076 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by die Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Lomanco Lo-OmniRidge LOR94 Ridge Vent TRI-BUILT" Lo-OmniRidge L01194 Ridge Vent LABELING: Each unit shall beat-a permanent label with the manufacturer's name or logo, city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for sales, advertising or any other purposes shall automatically tenninate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 19-0509.02 and consists of pages 1 through 5. The submitted documentation was reviewed by Freddy Semino �r NOA No.: 19-1217.05 Mwr�wrweeouNnr Expiration Date: 09/04/23 Approval Date: 01/23/20 Page 1 of 5 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Ventilation Materials: Plastic Minimum Slope: 3:12 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Product Product Dimensions Specification Description Lomanco Lo-OmniRidge 4' x 11'/z"x 1/4" TAS 100A Ridge ventilation system (LOR9-4)Ridge Vent Min.thickness 0.75" TRI-BUILT'Lo-OmniRidge 4' x 11'/2"x 3/4" TAS 100A Ridge ventilation system (LOR94)Ridge Vent Min.thickness 0.75" TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS Test Product Product Dimensions Specification Description Manufacturer Roofing Nails Min. 12 ga. TAS 114 Appendix E Corrosion resistant annular ring Generic 1 3/4" shank nails MANUFACTURING LOCATION 1. Jacksonville, AR EVIDENCE SUBMITTED Test Aaency/Identif3er Name Report Date PRI Construction Materials Technologies,LLC TAS 100 LOM-003-02-01 01/15/03 TAS 100(A)-95 LOM-029-02-01 08/15/13 ASTM G155 LOM-047-02-01 04/15/16 ASTM D638 LOM-047-02-01 04/15/16 ASTM E1252 LOM-026-02-01 05/23/13 ASTM D635 LOM-033-02-01 03/28/14 ASTM D1929 LOM-034-02-01 03/28/14 ASTM D2843 LOM-041-02-01 06/05/14 NOA No.: 19-1217.05 aMAWm= DAM Expiration Date: 09/04/23 Approval Date: 01/23/20 Page 2 of 5 APPROVED APPLICATIONS Tradename: Lomanco Lo-OmniRidge(LOR9-4)Ridge Vent TRI-BUILT Lo-OmniRidge(LOR9-4)Ridge Vent System Type: Mechanical attachment of ridge vent system over composition shingles. Slot: Truss Construction: Cut shall be 1-'/4"wide and 6" shorter at each end than the total length of the ridge vent to be installed. Ridge Pole Constriction: Cut shall be 2 3/4""wide and 6" shorter at each end than the total length of the ridge vent to be installed. Installation: Connect all the male tabs with the female tabs across the entire roof before vent is nailed down. This will ensure that the vents are as straight as possible. Mark proper alignment and end line for vents with chalk; snap a chalk line down both sides of the ridge at a distance of 5 '/2"down from the peak as shown in the manufacturer's installation instructions. Starting with the first vent,nail the vent down with roofing nails placed 12"on center at manufacturer pre-marked locations. Use nails of sufficient length to penetrate through the sheathing a minimum of 3/16"or at least 1"into wood plank decking thicker than l". Tf the vent is being installed in cold weather,leave a 1/a" gap between each vent to allow for expansion in hot weather. Continue to nail the remaining pieces down taking care to keep the vents as straight as possible. The last piece may be cut to the proper length. Ridge Shingle: Using nail lines provided on top of vent, install the cap shingles directly to the vent, in compliance with the shingle manufacture's Notice of Acceptance (NOA)and installation instructions,using roofing nails of sufficient length to penetrate through the sheathing a minimum of 3/16"or at least 1"into wood plank decking thicker than 1". Ventilation Calculations: Refer to manufacturer's published literature. NOA No.: 19-1217.05 APPMIAMI•DAROVED 7Y Expiration Date: 09/04/23 Approval Date: 01/23/20 Page 3 of 5 LIMITATIONS I. Refer to applicable Building Code for required ventilation. 2. Ridge Vent shall comply with applicable Building Code 3. Lomanco Lo-OmniRidge (LOR9-4) Ridge Vent and TRI-BUILT' Lo-OmniRidge (LOR9-4) Ridge Vent shall not be installed in conjunction with Gable vents. 4. Lomanco Lo-OmniRidge (LOR9-4) Ridge Vent and TRI-BUILT` Lo-OmniRidge (LOR9-4) Ridge Vent shall not be installed on roof hips. 5. Lomanco Lo-OmniRidge (LOR9-4) Ridge Vent and TRI-BUILT'$' Lo-OmniRidge (LOR9-4) Ridge Vent shall not be connected at ridge intersection, or within 12" of any side wall or roof protrusion, with a ventilation slot clearance of 12"from such obstructions. 6. Lomanco Lo-OmniRidge (LOR9-4) Ridge Vent and TRI-BUILT" Lo-OmniRidge (LOR9-4) Ridge Vent shall not be installed on roof mean heights greater than 33 ft. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 19-1217.05 MIAMFAPPRO LINTY Expiration Date: 09/04/23 Approval Date: 01/23/20 Page 4 of 5 DETAIL DRAWINGS 9 �, Lr I I 71 ? 4{ I k� i 3' ;. 48„ if._ ri i 3 ly r D 3n 4 LoMANco Lo-OMNIRIDGE LOR9-4 RIDGE VENT TRI-BUILTO L0-0MNiRIDGE LOR94 RIDGE VENT END OF THIS ACCEPTANCE MIAMFWIDE COUNTY NOA No.: 19-1217.05 • r Expiration Date: 09/04/23 Approval Date: 01/23/20 Page 5 of 5