Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED, Permit Appl for 4845 Grovers Rd Additional
Section A (General information) Master Permit No. Process No. Contractors Name: One construction & Roofing contractors License # CCC-1330623 Job Address 4845 Grovers RD Fort Pierce. F134951 ROOF CATEGORY 91 Low Slope © Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles 0 Asphaltic Shingles 0 Metal Panel/Shingles I3Wood Shingles/Shakes 0 Prescriptive BUR-RAS 150 ROOF ROOF TYPE_ ❑ New roof 0 Repair © Maintenance ® Reroofing ❑ Recovering -ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) 506 sq. ft. Steep Sloped Roof Area (SF) 3,090 sq ft Total (SF) 3,596 sq ft Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. AIR.; ,2e> a�`LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: POLYGLASS USA Product Approval No.: FL#1654-R28 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': -36.1 Zone 1: -36-1 Zone 2: -47.7 Zone 3: -64.9 Max. Design Pressure, from the specific product approval system: Peel & stick / SBS-SA Deck: Type: Plywood Gauge Thickness: 19/32 CDX Slope: 1/12" Anchor/Base Sheet & No. df Ply(s): N/A Anchor/Base Sheet Fastener/Bonding Material: N/A Insulation Base Layer: N/A Base Insultation Size and Thickness: N/A Base Insulation Fastener/Bonding Material: N/A Top Insulation Layer: N/A Top Insulation Size and Thickness: N/A Top Insulation Fastener/Bonding Material: N/A Base Sheet(s) & No. of Ply(s): 1 Base Sheet Fastener/Bonding Material: SELF -ADHERING Ply Sheet(s)' & No. of Ply(s): 1 Ply Sheet Fastener/Bonding Material: SELF -ADHERING Top Ply: 1 Top Ply Fastener/Bonding Material: SELF -ADHERING Surfacing: N/A Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—" oc @ Lap, # Rows @ "oo Zone 1:_" oc @ Lap, # Rows @ "00 Zone 2:—__" oc @ Lap, # Rows @ "oo Zone 3:_.,_" oc @ Lap, # Rows @ .00 Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3 illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. . 51" LU IE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: Extreme Metal fabricators, LLC Notice of Acceptance Number: FI # 17022-R8 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:-38.1 Zone 2e: 50.2 Zone 2n: 50.2 Zone 2r:-49.6 Zone 3e:-50.2 Zone 3r: -50.2 Deck Type: 19/32 CDX Plywood Type Underlayment: Owen comings / Titanium Roof underlayment Roof dope: 5 i2 Insulation: N/A Fire Barrier: N/A Ridge V i�t ISition? Fastener Type & Spacing: #10 X 1.5" FASTENER WITH SEAL WASHER N/A #1OAT 16" O.0 i Adhesive Type: WA Type Cap Sheet: i N/A 1 Mean Roof Height: 12 Roof Covering: 5V metal roof / 26 gauge Type & Size Drip 2" x 2" / Galvalumee Edge: ��