Loading...
HomeMy WebLinkAboutDesign Pressure Report (John Roland Jr) - Florida Window & Door Florida Window & Door Co. 1 125 N.Dixie Hwy Tel.(561)848-4900 LakeWorth, FL 33460 Floridawindowanddoor.com Property Information Building Information Owner: John Roland Jr Wind Zone: 160 MPH. Address: 10751 S Ocean Drive A9 Exposure Category: D Jensen Beach,FL 34957 Minimum Building Dimension: 40 ft. Mean Roof Height: 16 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 End 37 80 7 39.2 -51.2 2 End 37 37 7 41.1 -55.0 3 End 37 18 7 41.1 -55.0 4 End 37 63 7 39.8 -52.4 5 End 26 38 7 41.1 -55.0 6 End 53 63 7 38.8 -50.5 7 End 53 63 7 38.8 -50.5 8 End 53 37 7 40.3 -53.4 9 End 53 26 7 41.1 -55.0 10 End 53 37 7 40.3 -53.4 11 End 53 26 7 41.1 -55.0 12 End 53 37 7 40.3 -53.4 13 End 53 26 7 41.1 -55.0 14 End 37 37 7 41.1 -55.0 15 End 37 18 7 41.1 -55.0 16 End 53 63 7 38.8 -50.5 17 End 37 63 7 39.8 -52.4 18 End 37 63 7 39.8 -52.4 19 End 37 63 7 39.8 -52.4 20 End 19 38 7 41.1 -55.0 Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code. Page 1 of 1