HomeMy WebLinkAboutFL15210.43/30/2021 Florida Building Code Online
4
BCIS Home { Log In i User Registration Hot Topics s Submit Surcharge Stats & Facts ; Publications i Contact Us I BCIS Site Map I Links X Search j
a
Product Approval
IN
USER: Public User
db
"
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL15210-R7
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer
Plastpro Inc. / Nanya Plastics Corp.
Address/Phone/Email
5200 W CENTURY BLVD.
LOS ANGELES, CA 90045
(440) 969-9773 Ext 16
rickw@rwbldgconsultants.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
Technical Representative Scott Johnson
Address/Phone/Email 5200 W Century Blvd.
Los Angeles, CA 90045
(440) 969-9773 Ext18
scottjohnson@plastproinc.com
Quality Assurance Representative Ron O'Connell
Address/Phone/Email 5200 W Century Blvd.
Los Angeles, CA 90045
(440) 969-9773 Ext16
ronoconnell@plastpro.com
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E.
Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2021
Validated By Ryan J. King, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL15210 R7 COI (b) Certificate of Independence. pdf
Standard
Year
ASTM D1929
1996
ASTM D2843
1999
ASTM D635
1998
ASTM D638
2003
ASTM E1300
2004
ASTM E84
2005
ASTM G26
1995
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZIQRCFPqu8gbCgpTT5HYBxRCwCEpiLejMsLBg%3d%3d 1/4
3/30/2021 Florida Building Code Online
G 155 2005
TAS 201, 202, 203 1994
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Cummnr of PrnAurfe
Florida Licensed Professional Engineer or Architect
FL15210 R7 Equiv of Standards (c)_pdf
Method 1 Option D
07/21/2020
07/30/2020
08/05/2020
10/13/2020
FL #
1 Model, Number or Name
Description
15210.1
a. Smooth/Wood Grain/White Wood
6'8 "Impact" Opaque Fiberglass Single Door -
Grain/Rustic/Mahogany Series O
Inswing/Outswing (X - Configuration)
Fiberglass Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15210 R7 II (c) Inst 15210.1.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 15210.1 for Design Pressure Ratings, any
FL15210 R7 AE fc) Eval 15210.1.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars.
15210.2 b. Smooth/Wood Grain/White Wood 6'8 "Impact" Opaque Fiberglass Single Door with Sidelite or
Grain/Rustic/Mahogany Series 0 Sidelites - Inswing/Outswing (OX or XO; OXO - Configurations)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15210 R7 II (j Inst 15210.2.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 15210.2 for Design Pressure Ratings, any FL15210 R7 AE (c) Eval 15210.2.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
15210.3 ' c. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series O
Fiberglass Door
6'8 "Impact" Opaque Fiberglass Double Door with or without
Sidelites - Inswing/Outswing (XX; OXXO - Configurations)
Limits of Use
Installation Instructions j
i Approved for use in HVHZ: Yes
FL15210 R7 II (c) Inst 15210.3.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 15210.3 for Design Pressure Ratings, any
FL15210 R7 AE (j Eval 15210.3.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars.
15210.4 d. Smooth/Wood Grain/White Wood 6'8 "Impact" Glazed Fiberglass Single Door - Inswing/Outswing
Grain/Rustic/Mahogany Series 0 (X Configuration)
Fiberglass Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15210 R7 II (O Inst 15210.4.pdf E
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
! Evaluation Reports
Other: See INST 15210.4 for Design Pressure Ratings, any
FL15210 R7 AE (c) Eval 15210.4.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars.
j
15210.5 j e. Smooth/Wood Grain/White Wood 6'8 "Impact" Glazed Fiberglass Single Door with Sideiite or
Grain/Rustic/Mahogany Series 0 1 Sidelites - Inswing/Outswing (OX or XO; OXO - Configurations)
Fiberglass Door
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgv3yVVKJZlQRCFPqu8gbCgpTT5HYBxRCwCEpILejMsLBg%3d%3d 2/4
3/30/2021
Florida Building Code Online
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15210 R7 II (c) Inst 15210.5 pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409 i
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 15210.5 for Design Pressure Ratings, any
FL15210 R7 AE (c) Eval 15210.5.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars.
15210.6
f. Smooth/Wood Grain/White Wood
6'8 "Impact" Glazed Fiberglass Double Door with or without
Grain/Rustic/Mahogany Series 0
Sidelites - Inswing/Outswing (XX; OXXO - Configurations)
Fiberglass Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15210 R7 II (c) Inst 15210.6.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 15210.6 for Design Pressure Ratings, any
FL15210 R7 AE (c) Eva) 15210.6.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars.
j
15210.7
g. Smooth/Wood Grain/White Wood
8'0 "Impact" Glazed Fiberglass Single Door - Outswing (X -
Grain/Rustic/Mahogany Series O
Configuration)
Fiberglass Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15210 R7 II (c) Inst 15210.7.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 15210.7 for Design Pressure Ratings, any
FL15210 R7 AE (j Eval 15210.7.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars.
15210.8
h. Smooth/Wood Grain/White Wood
8'0 "Impact" Glazed Fiberglass Single Door with Sidelite or
Grain/Rustic/Mahogany Series 0
Sidelites - Outswing (OX or XO; OXO - Configurations)
Fiberglass Door
i
I
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15210 R7 II (!O Inst 15210.8.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 15210.8 for Design Pressure Ratings, any
FL15210 R7 AE (c) Eval 15210.8.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars.
i
15210.9 i. Smooth/Wood Grain/White Wood
8'0 "Impact" Glazed Fiberglass Double Door with or without
fGrain/Rustic/Mahogany Series 0
Fiberglass Door
Sidelites - Outswing (XX; OXXO - Configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15210 R7 II (j Inst 15210.9.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports j
Other: See INST 15210.9 for Design Pressure Ratings, any
FL15210 R7 AE (c Eval 15210.9.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars.
1
15210.10 j. Smooth/Wood Grain/White Wood
8'0 "Impact" Opaque Fiberglass Single Door- Outswing (X -
Grain/Rustic/Mahogany Series 0
Configuration)
Fiberglass Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15210 R7 II (c) Inst 15210.10.pdf j
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409 j
Impact Resistant: Yes
Created by Independent Third Party: Yes I
Design Pressure: N/A
Evaluation Reports
Other: See INST 15210.10 for Design Pressure Ratings, any
FL15210 R7 AE (c) Eval 15210.10.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars.
15210.11 k. Smooth/Wood Grain/White Wood
8'0 "Impact" Opaque Fiberglass Single Door with Sidelite or
Grain/Rustic/Mahogany Series 0
Sidelites - Outswing (OX or XO; OXO - Configurations)
Fiberglass Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15210 R7 II (� Inst 15210.1l.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 15210.11 for Design Pressure Ratings, any
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQvADgv3yVVKJZlQRCFPqu8gbCgpTT5HYBxRCwCEpILejMsLBg%3d%3d 3/4
3/30/2021
Florida Building Code Online
additional use limitations, installation instructions and product
FL15210 R7 AE (c) Eval 15210.11.pdf
particulars.
Created by Independent Third Party: Yes
15210.12
I. Smooth/Wood Grain/White Wood
8'0 "Impact" Opaque Fiberglass Double Door with or without i
Grain/Rustic/Mahogany Series O
Sidelites - Outswing (XX; OXXO - Configurations)
Fiberglass Door
i
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15210 R7 II _(c)_Inst 15210.12.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 15210.12 for Design Pressure Ratings, any
FL15210 R7 AE fc Eval 15210.12.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars.
15210.13
m. Smooth/Wood Grain/White Wood
8'0 "Impact" Opaque Fiberglass Single Door with Surface Bolts
Grain/Rustic/Mahogany Series 0
- Outswing (X - Configuration)
Fiberglass Door
i
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15210 R7 II (C) Inst 15210.13.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 15210.13 for Design Pressure Ratings, any
FL15210 R7 AE (c) Eval 15210.13.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars.
15210.14
n. Smooth/Wood Grain/White Wood
8'0 "Impact" Opaque Fiberglass Double Door with Surface Bolts
Grain/Rustic/Mahogany Series 0
on Active Door panel - Outswing (XX - Configuration)
Fiberglass Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15210 R7 II (c) Inst 15210.14 p-df
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 15210.14 for Design Pressure Ratings, any
FL15210 R7 AE (C) Eval 15210.14.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars.
15210.15 o. Smooth/Wood Grain/White Wood
8'0 "Impact" Glazed Fiberglass Single Door utilizing the
Grain/Rustic/Mahogany Series O
WINDSERTTI an operational window insert - Outswing (X -
Fiberglass Door
Configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15210 R7 II (j Inst 15210.15.pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 15210.15 for Design Pressure Ratings, any
FL15210 R7 AE (C) Eval 15210.15.pdf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars.
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Credit Card
Safe
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZlQRCFPqu8gbCgpTT5HYBxRCwCEpILejMsLBg%3d%3d 4/4
R W R W Building Consultants, Inc.
BConsulting and Engineering Services for the Building Industry
f P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197
l • Florida Board of Professional Engineers Registry License No. 9813
Product
Category
Sub Category
Manufacturer
Product Name
Plastpro, Inc.
Smooth / Wood Grain / White Wood Grain
Exterior
Swinging
Exterior Door
5200 W. Century Blvd.
Rustic /Mahogany
Doors
Assemblies
Los Angeles, CA 90045
Series O Fiberglass Door
Phone 440.969.9773
Inswing/Outswing - "Impact"
Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for
Plastpro Inc., based on Rule Chapter No. 61G20-3, Method 1 D of the State of Florida Product Approval, Department of
Business & Professional Regulation.
RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named
herein.
Limitations:
1. This product has been evaluated and is in compliance with the 7th Edition (2020) Florida Building Code structural requirements
including the "High Velocity Hurricane Zone".
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in the "HVHZ" this product complies with Section 1626 of the Florida Building Code and does not require an impact
resistant covering.
4. When used in areas outside of the "HVHZ" requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 &
R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as
defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1.
5. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction.
6. Site conditions that deviate from the details of drawing FL-15210.4 require further engineering analysis by a licensed engineer or
registered architect.
7. Outswing configurations meet water infiltration requirements for "HVHZ". All other configurations do not meet the water infiltration
requirements for the "HVHZ" and must be installed only in non -habitable areas or at habitable locations protected by an overhang or
canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees.
8. See drawing FL-15210.4 for size and design pressure limitations.
Supporting Documents:
1. Test Report No.
Test Standard
Testing Laboratory
TEL 01390365
TAS 201-94, 202-94 & TAS 203-94
Testing Evaluation Lab., Inc.
TEL 01391846
TAS 201-94, 202-94 & TAS 203-94
Testing Evaluation Lab., Inc.
ETC-05-255-16776.0
ASTM D 635-98, 638-03. 1929-96 & 2843-99
ETC Laboratories
ASTM G 26-95
ETC-06-255-17412.0
ASTM E 84-05
ETC Laboratories
ETC-07-209-19303.0
ASTM D 635-98, 638-03, 1929-96 & 2843-99
ETC Laboratories
2. Miami -Dade NOA
Materials
17-0712.05
Saflex PVB Interlayer (Eastman Chemical Company)
17-1026.08
Royal Mouldings (Ext. PVC)
3. Drawing No.
No. FL-15210.4
4. Calculations
Anchoring
ASTM E 1300 Glass Load
5. Quality Assurance
Prepared by
RW Building Consultants, Inc. (#9813)
Prepared by
RW Building Consultants, Inc. (#9813)
Lyndon F. Schmidt, P.E.
�`��o��aasa pP'e`Ps
• r
.: .
0
® •rr
r.J t`i t •�aa
v
Sheet 1 of 1
Signed by
Lyndon F. Schmidt, P.E.
William Shelton, P.E.
Joseph L. Doldan, P.E.
Joseph L. Doldan, P.E.
Ben Meunier
Signed & Sealed by
Lyndon F. Schmidt, P.E.
Signed & Sealed by
Lyndon F. Schmidt, P.E.
Lyndon F. Schmidt, P.E.
FL PE No. 43409
7/29/2020
plastpro
5200 W. CENTURY BLVD.
LOS ANGELES, CA 90045
Smooth / Wood Grain / White Wood Grain
Rustic / Mahogany
Series O Fiberglass Door
INSWING / OUTSW►NG
,,immcr
GENERAL NOTES
1. This product has been evaluated and is in compliance with the 7th Edition (2020) Florida Building
Code (FBC) structural requirements including the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base
material shall be beyond wall dressing or stucco.
3. When used in the "HVHT'this product complies with Section 1626 of the Florida Building Code and
does not require an impact resistant covering.
4. When used in areas outside of the "HVHZ" requiring wind bome debris protection, this product
complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering.
This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E 1996 and FBC
Sections 1609.1.2.2 & R301.2.1.2.1.
5. For 2x stud construction, anchoring of these units shall be the same as that shown for 2x buck masonry
construction.
6. Site conditions that deviate from the details of this drawing require further engineering analysis by a
licensed engineer or registered architect.
7. Outswing configurations meet water infiltration requirements for "HVHT'. All other configurations do
not meet the water infiltration requirements for the "HVHZ" and must be installed only in non -habitable
areas or at habitable locations protected by an overhang or canopy such that the angle between
the edge of canopy or overhang to sill is less than 45 degrees.
TABLE OF CONTENTS
SHEET If
DESCRIPTION
SHEET#
DESCRIPTION
1
Typical Elevations, Design Pressures & General Notes
8
Horizontal & Vertical Cross Sections (Direct to Masonry)
2
Door Panel Details
9
3-point lock details
3
Lite frame details and glazing details
10
3-point lock details
4
Horizontal & Vertical Cross Sections (2X Buck)
11
Buck and frame anchoring
5
Horizontal & Vertical Cross Sections (1X Buck)
12
Components
6
Horizontal & Vertical Cross Sections (Direct to Masonry)
13
Bill of materials
7
Vertical Cross Sections (Thresholds)
37.50" MAX. OVERALL
FRAME WIDTH
0 Z
Z_ 3
3
z M
0
L
w aau,
LL
J
w w
o
a
00co
CONFIGURATION
MAX
,FRAME..J
D/MENSION.:
DESIGM PRESSURE (PSF)
-POSITIVE'.
NEGATIVE':'.
x
37.5" x 82.0"
+75.0
-75.0
See sheets 2 & 4 for hardware and lite frame design pressure limitations
Rn
In
gZ �Z 6g10
*''''r*
'%
oCmLh
UN ••�
�
E v Z O Z K
G Em m
u
N
a mOa�
g d
-=i
E 0 z
u� w
o° d
onr[, 02116 12
SCALE: N.T.S.
owO. B/: JK
CHN. BY: I.FS
Ft.-15210.4
eer 1 OF 13
0.7'
CAP (PVC)
HINGE STILE (LVL)
EXTERIC
.I INTERIO
2 HORIZONTAL CROSS SECTION
35.75" DOOR
WIDTH
2
2
�J
co :z
4 2 X
0
• SEE HARDWARE
TABLE
SEE HARDWARE
TABLE
40 DOOR PANEL
LATCH STILE (LVL)
HARDWARE TABLE
MANUFACTURER
MORE!
MAX DESIGN i
.PRESSURE` (PSF
KNOB: SIGNATURE SERIES
KWIKSET
* 75
DEADBOLT: SIGNATURE SERIES (980)
SCHLAGE
KNOB: "P'SERIES (F51)
"B"
±75
DEADBOLT: SERIES (B60/62)
PAMEX
LEVER: FL311 SERIES
±75
DEADBOLT: FD7 SERIES
HOPPE
MULTIPOINT LOCK: HLS9000 3•POINTTONGUE
± 50
ENDURA
MULTIPOINTLOCK: TRILENNIUM30D0(3•PT)
±75
See sheets 6 and 7 for multipoint lock details.
TOP RAIL
(COMP.) T
T
d
INTERIOR
a:
FIBERGLASS SKIN a '
(0.125" MIN. THK.)
FOAM CORE
(POLYURETHANE-
1.9 PCF MIN.)
EXTERIOR
BOTTOM RAIL
(COMP.)
/',2_1 VERTICAL CROSS SECTION
2
z
Omw
PIP
U
�`��
z m z
n
p
cv
9
E Em
0 x z m
zm
N
o NM
mm
�pL a
^
\\\y r.i
a a
m d a
T
LL
ti
-=i
E vz
Cola
c BS
(li
n
Of o
�0 o
ON J J
ag m Z
a
am i
4 0
�I 0O 0
0
a a
SCALE: N.T.S.
OWG. BY: JK
CHK. BY: LFS
DRAWING NO.:
FL-15210.4
SHEET 2 OF 13
C
J
24.22" MAX. .. /����
FRAME WIDTH 5/8"GLASS BITE �`PA,
20.50" MAX.'
D.L.O. WIDTH S
TRUCTURAL SILICINE (DOW 995) - =e `o;' x'
N
EXT. i--�
1" OVERALL GLASS THK.
N 1.86" 1.86" %i yy` F N rn
1/8"ANNEALED GLASS i ....... '�i� � o o
b O0.09D" SAFLEX®PVB�///*P1% `��`anm I,INTERLAYER 0 a6
1 /8"ANNEALED GLASS NEz o o m*
AIR SPACE0 °a 0 a1/8" TEMPERED GLASS Nmaq Va(TYP') EXi FRAME INT. FRAME T a ALUMINUMSPACER A3 A4-'9z
O CTURAL SEALANT °3/4"PPH SELF -DRILLING SMS
INT.
GLAZING DETAIL
°'Ln
io �o
4
O'nYwz
�j CL m
4.25" i
(TYP.) am_ a
ODL LITE FRAME w o
0
0
24" MAX, a a
FRAME WIDTH
20.75" MAX. �� m
D.L.O. WIDTH
�L�
ona
dj o00
EXT. N N N
1 /2" GLASS BITE
�� A5 WWW o
1-1/4"OVERALL THK.GLASS STRUCTURAL SIUCINE(DOW995) Xt N
1/8"ANNEALED GLASS o 0 0
w
x 0.090"SAFLEX®PVB w w w
O 6 INTERLAYER ¢ a
(nP') 1 /8" ANNEALED GLASS 1.59 ? $
AIR SPACE \ Qo
�L
1/8"TEMPERED GLASS ^ ^
O fq d 1/2'NON-GROOVESWIGGLE N o
W/ DELCHEM#80 POLYSULFIDE A7 40 02116112
1/8"BACKFILL A6
#10XI-3/4"PPH WOOD SCREW SCALE: N.T.S.
GLAZING DETAIL
EXL FRAME INT. FRAME SCREW CAP DING. BY: JK
(NP) � �� INT. G2 A5 A6 A7 cHK. BY, LFS
DRAWING NO.:
RSL LITE FRAME FL-15210.4
SHEEP 3 OF 13
LREFRAMEiABLE
MAX. DESIGN
MANUFACTURER
,PRESSURE: $ ;
ODL
± 75
RSL
± 60
a
d
v
V
C
3 3
3
5 6
...
`\\\AC •
4 5
6
8 8
; !-Q.;-
z
.0
m m
u
\\ N
7
zo;a
U
C
\\\v N
OK
E z m ,
O
N
m c w
o as a
poaaln
Naga
m
X
`LL
c 0
u 0Z
1
4
O
4
`W
o �d
2
1
5
5 /
2
�m
6
6
1
2
—o
8
8
��
aiz
3 4
D
4 1-1/4"MIN.
v c'
SW
w rz w
ol>
8
8 EMB. (TYP.)
p, m
r�
E
1
2
3
2 1
of
o 00
8,
B
C 7
7
D
B
U
.4 L
0.15'
C'SINK --- C
D
"
m
(TYP.)
_ 0.15' C-SINK E ° o
°
(nP)
`a �Y
�L n
v
°
4
T m
1
2
p, v
ona
0
°
INTERIOR
N
N
N
D
B
El
Ea
z
o
a 7
L
40
58 0
7
1a
nN
z
11 11
EXTERIOR 27 A
INTERIOR
DATE: 02 16/12
1-1/4'"MIN. L 9
E
EXTERIOR
o
SCu-E: N.T.S:
EMB. (TYP.)
40
°
DwG. BY: JK
1 HORIZONTAL CROSS SECTION
2
HORIZONTAL CROSS SECTION
3 VERTICAL CROSS SECTION
cHK, eY: LFS
DRAWING NO.:
q Outswing shown Inswing similar) q Outswing shown (Inswing SIM110T) 4 Outswing shown (inswing similar)
FL-15270.4
SHEEP _�L OF 13
a
T
0
V
K
'N•, c OWN rnn
L omen
rn
�•.'••. of
z m z
T U N m
Z O Z K
m
N to 9 cw
E u a o D.
� mdam
c 4
0
5 E oz
A
c V)
E o �d
C E
2 1
C '<m
°v o° Ci0 �X
° ZO jam.
O
J 1 2 J J &�2 �z
JO
E > go ^ pcn
am N
7 e� °
INTERIOR 40 o oI a
G
A
moo] V mEE
UU
u� cl n d
40 NNN
11 EXTERIOR °w w w z
11 1 2 D
EMB. MIN. 9 4p 27 G EXTERIOR o 0 o
-' EMB. (TYP.) t-1/a" Mw. INTERIOR
EMB. (TYP.) W- 1'
000
ana u
HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION �3 VERTICAL CROSS SECTION o
$ Shown w/ I sub -buck j Shown w/ 1X sub -buck g Shown w/ I sub -buck w
Outswing shown (Inswing similar) Outswing shown (Inswing similar) Outswing shown (Inswing similar) N N O
N
o
MN •-z [Dl
DATE 02/16/12 z
0
SCALE: N.T.S.
DWG. BY. JK m
CHK. BY: LFS 3
DRAWING NO.: m
FL-15210.4 0
SHEET S OF 13
Q'
m
a
#.Z--
z
rc'e��0�
�'•.
��i ••'•.........
7a
•�45`� It
m d
On
a C4 .. m
O
0
V � Z�
e e
Em mu
o
OM 5d0Q.
'5
d m a 0
\\V=
s o
�
c
E 0
o wTo Lim
E
E
N>
Oc
2 C
�0
C
U
K
¢�
o ay.
vo Q
Zo
�O
D a 1 2
p
p
Z a
>✓
O �o
dm
< Zcn
7
J
o.
O Nrz
7
��
M v
INTERIOR 40
o
ow
Sin
m
C
U U
�
n a
4O
NNN
EXTERIOR
rn
o
40
9
27 M
rn
EXTERIOR
INTERIOR
o
0 0
1-1/4 MIN.
w
EMB. (TYP.)¢p
o¢ ¢o
C,
HORIZONTAL CROSS SECTION �21 HORIZONTAL CROSS SECTION �1 VERTICAL CROSS SECTION
6 Shown Direct to Masonry
6
Shown Direct to Masonry
6
Shown Direct to Masonry
N
N rn
W
a i
Outswing shown (Inswing similar)
Outswing shown (Inswing similar)
Outsw ng shown (Insw ng similar)
^ n
o
DATE: 02116112
SCALE: N.T.S. '
OWC. BY: JK
CHI. BY: LFS
DRAWING NO.: T
FL-15210.4 �
SHEET 6 OF 13
• •6,
x
Loa
M�
�`�\\\ o m z
U Cl •• W
O
N
NK
v 0 p Z�
o Em Z m u
NM 96La
Na
,a maa�-
_5
9
EXTERIOR INTERIOR
E o=
] 9
U [IJ
c 3a
Of
N
8 40
z_0
oN
29
O
�"
a5
U�
'
I
UEO
�m
W
(n�
W
w 1=tn
aIn
< WO
EXTERIOR INTERIOR
c `
o w
a o
a C
< a
EXTERIOR
INTERIOR
o
I
40
ao a a 9 a
Qtl
a
a
e
a
m m
30 31 32 33 34 40
2 VERTICAL CROSS SECTION
8
e
IL w
7 Shown w! ADA threshold
36
37
NNN
38
www
o
E��
x
rn
w
n e e
E
o00
e e o n
a o a
> p
a-
a a a a a n
o00
>
j:D
z
D
..49
d a
d
a G '
a
Z
t�V^�
VERTICAL CROSS SECTION
7 Outswing confirguration
3 VERTICAL CROSS SECTION
z
^
N
�7 J Inswing configuration
DATE: 02116112 z
SME: N.T.S. D
m
DWG. BY, JK m
CHK. BY: LFS 3
DRAWING NO, G:
FL-15210.4 To
SHEET —L OF 13 N
Z d I,5"
MAX.
5 VERTICAL CROSS SECTON
$ Shown Direct to Masonry
Outswing only w/ 4-9/16' jamb
C
in z z_
z4 ry INTERIOR
40 40
Uo a M
1-1/4" MIN. "'
EMB. (TYP.)
E _- _--\\ EXTERIOR
1-1 /4" MIN.
EMB. PP.)
1 HORIZONTAL CROSS SECTION r2 HORIZONTAL CROSS SECTION
$ Shown Direct to Masonry $ Shown Direct to Masonry
Outswing only w/ 4-9/16'jamb Outswing only w/ 4-9/16'jamb
Z n _ 1.5"
MAX.
w I MIN. 1.5°
MAX.
EXTERIOR _W INTERIOR
r1 VERTICAL CROSS SECTION
$ Shown Direct to Masonry
Outswing only w/ 6-9/16jamb
X
i
I rn Z
op a
N
M D y.
o
1-1/4" MIN.
EMB. (TYP.)
r3HORIZONTAL CROSS SECTION
Shown Direct to Masonry
Outswing only w/ 6-9/16'jamb
INTERIOR
EXTERIOR
• .............
.
^�
`dam'
U M
d
z
O`Nwmro
0m.0
Q
Q C O
\\\```
z o 10
U N •: y
N
N
°n. t
_ Oc
ZZ
m
W
O
a rnn
_g IL
Rtm
N
<
m rLdLL
�
T 9 4
c �z0
U
1-1/4"MIN.
EMB, (TYP.)
�DATE:02/16/123
E; N.T.S.4
HORIZONTAL CROSS SECTION
eY. JK m
$ Shown Direct to Masonry
cHk. W. LFS
Outswingonly w/6-9/16'jamb
O.'0.;
FL-15210.4
SHEET 8 OF 13
*�0�4
.
AC .
Z
•C7 Z oo a
�Y?
•......
''\\\
m
0
(7
0
�711
• I�
7 M] Z
\ U N m
tv
m
o rn
0
cQ
E z ozrc
m
0 0
N
Ern m
o °a 9 p o a
.M,
0o
0
N
?
��°z
a ma:0,a
c ' o
c
o
0 0
Q
2X BUCK
IXBUCK
$$
G
}
I
y
o° �cU)
0
s
DIRECTTO
o O
MASONRY
M
Q
4
o
zo
D
c
23
pN
a
Y
m
=
2.17'
gw
n
2X BUCK
58
a
HOPPEMULTIPOINTLOCKSET =
22
IX BUCK
G
25
as
O
m m
HL5900D&Point'Tongue'
}
DIRECT TO M
a
MASONRY
m
—►1 1.T' �—
2X BUCK
$$
1XBUCK
G
N
N N
DIRECT TO
M
23
o d
z
MASONRY
g
w w
o
rn
_
h
� 22
W
o00
z
, cq
STRIKE JAMB
N
N
Q
n
� M
p
•v
c+i
DATE: 02 16 12
SCALE: N.T.S.
j` ®
DWG. BY: JK
0
cHx, eY: LFS
MULi1POfNTS1RIKE PLATE LATCH AND DEADBOLTSTRIKE PLATE
25
DRAWING ND.:
23 Tongue system
FL— 7 5210.4
MANUAL RAISED TONGUE GEAR SYSTEM
SHEET J of 13
p�C;
J.• w
g, o AN M
Z'•y: rz omw
•'....fit Q ca;a
g:
IS p
UN ••,
O 55 U O Z K
N �' z
o B Ern om m
ct & o00 d oa
c CZ
� o C
w
�d
CC
d O
0
Y
KN j: VO
O F4-s m J
0.W n Z
0. Ca O
4
0 UI 0
o �
� a
a a
M
® mmm
to
N
0 57 NNN
N
60 Z
°ww O
n b h W
62 00O K
O OOD
i 7 Z
2X BUCK 58 o n F
N � � lal =
1XBUCK G NN Q
c DIRECTTO M n i
MASONRY n N111 • Z o°
DATE: 02116112 z
SCALE: N.T.S.
5
DWG. BY: JK m
STRIKE JAMB DETAIL cHK. BY: LFS 3
ENDURATRILENNIUM3000 DRAWING ND.: m
N
3 pt. Lock FL-15210.4 0
SHEET 1 D OF 13
(TYP.) y
D TYP. HEAD
—" &JAMBS
7
MASONRY
OPENING
2X BUCK
� U
"2 o
0
BUCK ANCHORING
CONCRETE ANCHOR NOTES:
I. Concrete anchor locations at the comers may be adjusted to maintain the min.
edge durance to mortarjoints.
2 Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to
maintain the min. edge distance to modarjolnts. additional concrete anchors
may be required to ensure the "MAX. ON CENTER" dimension are not exceeded.
3. Concrete anchor table:
ANCHOR
ANCHOR
MIN.
MIN. CLEARANCE
MIN. CLEARANCE
-. TYPE
SIZE
TO MASONRY
TO ADJACENT`.
.':EMBEDMENT:
'EDGE
_ANCHOR ::
IT
TAPC ON ®
1/" 4
1.1/4"
2"
4"
ELCO ULTRACON ®
T/ " 4
1.1 /4"
ITN, a
TA PCON
3/16"
1.1/4"
AS SHOWN
1.1/2,
1. WOOD SCREW INSTALLATION NOTES:
Maintain a minimum 5/8"edge distance, I"end distance, & I"o.c. spacing of
wood sueva to prevent the splitting of wood.
4-9/16" JAMB p DIRECT TO MASONRY JAMB
(TYP.)
(SEE SHEET 8)
SEE HINGE L 2X BUCK
o
a
DETAIL (TYP,)
G 1X BUCK
DIRECT TO
D
=
MASONRY MASONRY
M
OPENING TYP. HEAD
& JAMBS
FRAME
V
4-9/16" JAMB M
— O
2X BUCK 6-9/16" JAMB N
DIRECT TO
r
MASONRY
JAMB (TYP.)
(SEE SHEET 8)
a ADA SILL
( ONLY
STRIKE
JAMB
FRAME ANCHORING
Masonry construction
DIRECT TO
DIRECTTO
MASONRY M
M MASONRY
28
1X BUCK G
G 1X BUCK
S
2X BUCK L
2X BUCK 58
58 2X BUCK
IXBUCK 11
DIRECT TO
M MASONRY
11
DIRECT TO 11 D
MASONRY
G 1XBUCK
27
/
58 2X BUCK
LATCH & DEADBOLTDETAIL
HINGE DETAIL
Inswing
DIRECT TO
MASONRY
1 X BUCK
2X BUCK
z*'g:dam
. lY
zz Lim
46
a n m
U N ••�
O a v
6 O
O p z o
m C
N o
a a Y
By
j W
O a
O
^
N
maam
5 0
E oz
'
c cW
3�d
^K�
J
z
Of
0
za
o
z
C)N
L5
J w
LnCD
m
am
UI
�
p
o Y
F U
Of
m
HINGE JAMB
HINGE DETAIL
Outswing
ALE: N.T.S.
G. BY: JK
C BY: LFS
WING NO.:
FL-15210.4
CET_ 11 OF 13
F
z
I'W,T
.' L". i
30ZOIITSWING THRESHOLD
DLP (QOSR)
4.68"
�100Z WING THRESHOLD
DLP(QOSH)
�i Ol1TSW1NG THRESHOLD
@a Endura (Z•Series)
gINSWING THRESHOLD
Enduro (Z_Series)
,rWING THRESHOLD
4 Columbia High Dam (581)
!V07fir li-mm"I'll, 1 M6�
�;\ ODTSWING THRESHOLD
"r Columbia (575)
(gNSWING THRESHOL0
"� Columbia
@INSWING THRESHOLD
DLP (ISCS)
O
ry
i f--2.44"2.13"—
POLY FIBER JAMB
Plasfpro
lv F --- 2.36" 2.2' —
2 WOOD JAMB
T 10
(Dj
WEATHERSTRIP
Endura Force 5
a 2.098"
o
0 \DOOR BOTTOM SWEEP
4.56"
:;;::��
29 ADA THRESHOLD
DLP
A,
1N g."........
ch'
m
O
o a
\
\V
CD
N
° t0
o u a
Na
ri
wy�
LL
T
� 0
G W
JTO.
N
M
ZM
J
"^n
Z 000
>°Z
N n
U N
0.
z oz'.
o m
=p=n.
mn:a�
SCALE: N.T.S.
owc. aY: JK
cnk. By. LFS
FL-15210.4
ET 12 of 13
Wp
z /
��rrrriri ��
— O M
F Og, z °° O m
��`` o M m 6
BILL Of MATERIALS
3
e
n,
mr U N .. a
LO O m C W
a NM Os m
a mdaw
N
0
E vz
N
N
p
o
s
0
U
zo
om
a5
I�
4Go
r
a
w
m
w o
—61 Of m
0
O
o
a
a
E
> >
}
m
_
n
mm�
onv
N N
=
>
N
W
n
W W
b N
z
O
N
iaa
2
F
=
J
�
N
O
N
n
\\W
q
M
M
N ^
a
z
=
Z ❑
DATE: 02/16/12
SCALE: N.T.S. °
DWG. BY: JK m'
-
CHK. BY: LFS 3
DRAWING NO.: �
FL-15210.4 "
0
—
SHEET 13 OF 13 N
_ Q
V
ITEM 9
DESCRIPTION
MATERIAL
A
1 X BUCK SG >= 0.55
WOOD
B
2X BUCK SG >= 0.55
WOOD
C
1/4" MAX. SHIM SPACE
-
D
1/4" X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW
STEEL
E
MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90
CONCRETE
G
3/i b" x 3-1 /4"PFH ITW CONCRETE SCREW
STEEL
I
1/4" X 1-3/4" PFH ELCO OR ITW CONCRETE SCREW
STEEL
J
1 /4" X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW
STEEL
K
1/4" X 2-1/4" ITW CONCRETE SCREW
STEEL
L
#10 X 2-1/7' PFH WOOD SCREW (1.15"MIN. EMBEDMENT)
STEEL
M
3/i b" X 2-1 /4" ITW CONCRETE SCREW
STEEL
N
3/16" X 2-3/4" ITW CONCRETE SCREW
STEEL
P
1!4" X 2-1 /4"PFH ELCO CONCRETE SCREW
STEEL
1
POLY FIBER JAMB
COMP. /VINYL
2
FINGER JOINTED PINE FRAME
WOOD
7
WEATHERSTRIP
FOAM
8
DOOR BOTTOM SWEEP
VINYL
9
4" X 4" BUTT HINGE
STEEL
11
#9 X 3/4"PFH WOOD SCREW
STEEL
22
3 POINT'TONGUE" MULTIPOINT LOCKSEi
(Mfg. BY HOPPE)
STEEL
23
MULTIPOINT STRIKE PLATE (TONGUE SYSTEM)
STEEL
25
LATCH AND DEADBOLT STRIKE PLATE (TONGUE SYSTEM)
STEEL
27
LATCH STRIKE PLATE
STEEL
28
DEADBOLT STRIKE PLATE (SECURITY)
STEEL
29
ADATHRESHOLD
ALUM
30
OUTSWING THRESHOLD
ALUM/WOOD
31
OUTSWING THRESHOLD
ALUM/WOOD
32
OUTSWING THRESHOLD
ALUM/WOOD
33
OUTSWING THRESHOLD
ALUM/COMP
34
OUTSWING THRESHOLD
ALUM/WOOD
36
INSWING THRESHOLD
ALUM/COMP
37
INSWING THRESHOLD
ALUM/WOOD
38
INSWING THRESHOLD
ALUM/COMP
40
DOOR PANEL -SEE DOOR PANEL DETAIL SHEEP FOR CONSTRUCTION DETAILS
-
55
#10 X 1-1/2"PFH SCREW
STEEL
57
BACKING PLATE
STEEL
58
#8 X 2"PFH WS
STEEL
60
MULTIPOINT STRIKE PLATE
STEEL
62
ENDURA TRILENNIUM 3000 LOCK ASSEMBLY
STEEL