Loading...
HomeMy WebLinkAboutFL15210.43/30/2021 Florida Building Code Online 4 BCIS Home { Log In i User Registration Hot Topics s Submit Surcharge Stats & Facts ; Publications i Contact Us I BCIS Site Map I Links X Search j a Product Approval IN USER: Public User db " Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL15210-R7 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Plastpro Inc. / Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 (440) 969-9773 Ext 16 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440) 969-9773 Ext18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440) 969-9773 Ext16 ronoconnell@plastpro.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J. King, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL15210 R7 COI (b) Certificate of Independence. pdf Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 1998 ASTM D638 2003 ASTM E1300 2004 ASTM E84 2005 ASTM G26 1995 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZIQRCFPqu8gbCgpTT5HYBxRCwCEpiLejMsLBg%3d%3d 1/4 3/30/2021 Florida Building Code Online G 155 2005 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Cummnr of PrnAurfe Florida Licensed Professional Engineer or Architect FL15210 R7 Equiv of Standards (c)_pdf Method 1 Option D 07/21/2020 07/30/2020 08/05/2020 10/13/2020 FL # 1 Model, Number or Name Description 15210.1 a. Smooth/Wood Grain/White Wood 6'8 "Impact" Opaque Fiberglass Single Door - Grain/Rustic/Mahogany Series O Inswing/Outswing (X - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II (c) Inst 15210.1.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.1 for Design Pressure Ratings, any FL15210 R7 AE fc) Eval 15210.1.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.2 b. Smooth/Wood Grain/White Wood 6'8 "Impact" Opaque Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series 0 Sidelites - Inswing/Outswing (OX or XO; OXO - Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II (j Inst 15210.2.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.2 for Design Pressure Ratings, any FL15210 R7 AE (c) Eval 15210.2.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.3 ' c. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series O Fiberglass Door 6'8 "Impact" Opaque Fiberglass Double Door with or without Sidelites - Inswing/Outswing (XX; OXXO - Configurations) Limits of Use Installation Instructions j i Approved for use in HVHZ: Yes FL15210 R7 II (c) Inst 15210.3.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.3 for Design Pressure Ratings, any FL15210 R7 AE (j Eval 15210.3.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.4 d. Smooth/Wood Grain/White Wood 6'8 "Impact" Glazed Fiberglass Single Door - Inswing/Outswing Grain/Rustic/Mahogany Series 0 (X Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II (O Inst 15210.4.pdf E Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A ! Evaluation Reports Other: See INST 15210.4 for Design Pressure Ratings, any FL15210 R7 AE (c) Eval 15210.4.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. j 15210.5 j e. Smooth/Wood Grain/White Wood 6'8 "Impact" Glazed Fiberglass Single Door with Sideiite or Grain/Rustic/Mahogany Series 0 1 Sidelites - Inswing/Outswing (OX or XO; OXO - Configurations) Fiberglass Door https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgv3yVVKJZlQRCFPqu8gbCgpTT5HYBxRCwCEpILejMsLBg%3d%3d 2/4 3/30/2021 Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II (c) Inst 15210.5 pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 i Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.5 for Design Pressure Ratings, any FL15210 R7 AE (c) Eval 15210.5.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.6 f. Smooth/Wood Grain/White Wood 6'8 "Impact" Glazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series 0 Sidelites - Inswing/Outswing (XX; OXXO - Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II (c) Inst 15210.6.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.6 for Design Pressure Ratings, any FL15210 R7 AE (c) Eva) 15210.6.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. j 15210.7 g. Smooth/Wood Grain/White Wood 8'0 "Impact" Glazed Fiberglass Single Door - Outswing (X - Grain/Rustic/Mahogany Series O Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II (c) Inst 15210.7.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.7 for Design Pressure Ratings, any FL15210 R7 AE (j Eval 15210.7.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.8 h. Smooth/Wood Grain/White Wood 8'0 "Impact" Glazed Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series 0 Sidelites - Outswing (OX or XO; OXO - Configurations) Fiberglass Door i I Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II (!O Inst 15210.8.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.8 for Design Pressure Ratings, any FL15210 R7 AE (c) Eval 15210.8.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. i 15210.9 i. Smooth/Wood Grain/White Wood 8'0 "Impact" Glazed Fiberglass Double Door with or without fGrain/Rustic/Mahogany Series 0 Fiberglass Door Sidelites - Outswing (XX; OXXO - Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II (j Inst 15210.9.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports j Other: See INST 15210.9 for Design Pressure Ratings, any FL15210 R7 AE (c Eval 15210.9.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 1 15210.10 j. Smooth/Wood Grain/White Wood 8'0 "Impact" Opaque Fiberglass Single Door- Outswing (X - Grain/Rustic/Mahogany Series 0 Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II (c) Inst 15210.10.pdf j Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 j Impact Resistant: Yes Created by Independent Third Party: Yes I Design Pressure: N/A Evaluation Reports Other: See INST 15210.10 for Design Pressure Ratings, any FL15210 R7 AE (c) Eval 15210.10.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.11 k. Smooth/Wood Grain/White Wood 8'0 "Impact" Opaque Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series 0 Sidelites - Outswing (OX or XO; OXO - Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II (� Inst 15210.1l.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.11 for Design Pressure Ratings, any https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQvADgv3yVVKJZlQRCFPqu8gbCgpTT5HYBxRCwCEpILejMsLBg%3d%3d 3/4 3/30/2021 Florida Building Code Online additional use limitations, installation instructions and product FL15210 R7 AE (c) Eval 15210.11.pdf particulars. Created by Independent Third Party: Yes 15210.12 I. Smooth/Wood Grain/White Wood 8'0 "Impact" Opaque Fiberglass Double Door with or without i Grain/Rustic/Mahogany Series O Sidelites - Outswing (XX; OXXO - Configurations) Fiberglass Door i Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II _(c)_Inst 15210.12.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.12 for Design Pressure Ratings, any FL15210 R7 AE fc Eval 15210.12.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.13 m. Smooth/Wood Grain/White Wood 8'0 "Impact" Opaque Fiberglass Single Door with Surface Bolts Grain/Rustic/Mahogany Series 0 - Outswing (X - Configuration) Fiberglass Door i Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II (C) Inst 15210.13.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.13 for Design Pressure Ratings, any FL15210 R7 AE (c) Eval 15210.13.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.14 n. Smooth/Wood Grain/White Wood 8'0 "Impact" Opaque Fiberglass Double Door with Surface Bolts Grain/Rustic/Mahogany Series 0 on Active Door panel - Outswing (XX - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II (c) Inst 15210.14 p-df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.14 for Design Pressure Ratings, any FL15210 R7 AE (C) Eval 15210.14.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.15 o. Smooth/Wood Grain/White Wood 8'0 "Impact" Glazed Fiberglass Single Door utilizing the Grain/Rustic/Mahogany Series O WINDSERTTI an operational window insert - Outswing (X - Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15210 R7 II (j Inst 15210.15.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.15 for Design Pressure Ratings, any FL15210 R7 AE (C) Eval 15210.15.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card Safe https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZlQRCFPqu8gbCgpTT5HYBxRCwCEpILejMsLBg%3d%3d 4/4 R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry f P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 l • Florida Board of Professional Engineers Registry License No. 9813 Product Category Sub Category Manufacturer Product Name Plastpro, Inc. Smooth / Wood Grain / White Wood Grain Exterior Swinging Exterior Door 5200 W. Century Blvd. Rustic /Mahogany Doors Assemblies Los Angeles, CA 90045 Series O Fiberglass Door Phone 440.969.9773 Inswing/Outswing - "Impact" Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for Plastpro Inc., based on Rule Chapter No. 61G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 7th Edition (2020) Florida Building Code structural requirements including the "High Velocity Hurricane Zone". 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ" this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the "HVHZ" requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 5. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of drawing FL-15210.4 require further engineering analysis by a licensed engineer or registered architect. 7. Outswing configurations meet water infiltration requirements for "HVHZ". All other configurations do not meet the water infiltration requirements for the "HVHZ" and must be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. 8. See drawing FL-15210.4 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory TEL 01390365 TAS 201-94, 202-94 & TAS 203-94 Testing Evaluation Lab., Inc. TEL 01391846 TAS 201-94, 202-94 & TAS 203-94 Testing Evaluation Lab., Inc. ETC-05-255-16776.0 ASTM D 635-98, 638-03. 1929-96 & 2843-99 ETC Laboratories ASTM G 26-95 ETC-06-255-17412.0 ASTM E 84-05 ETC Laboratories ETC-07-209-19303.0 ASTM D 635-98, 638-03, 1929-96 & 2843-99 ETC Laboratories 2. Miami -Dade NOA Materials 17-0712.05 Saflex PVB Interlayer (Eastman Chemical Company) 17-1026.08 Royal Mouldings (Ext. PVC) 3. Drawing No. No. FL-15210.4 4. Calculations Anchoring ASTM E 1300 Glass Load 5. Quality Assurance Prepared by RW Building Consultants, Inc. (#9813) Prepared by RW Building Consultants, Inc. (#9813) Lyndon F. Schmidt, P.E. �`��o��aasa pP'e`Ps • r .: . 0 ® •rr r.J t`i t •�aa v Sheet 1 of 1 Signed by Lyndon F. Schmidt, P.E. William Shelton, P.E. Joseph L. Doldan, P.E. Joseph L. Doldan, P.E. Ben Meunier Signed & Sealed by Lyndon F. Schmidt, P.E. Signed & Sealed by Lyndon F. Schmidt, P.E. Lyndon F. Schmidt, P.E. FL PE No. 43409 7/29/2020 plastpro 5200 W. CENTURY BLVD. LOS ANGELES, CA 90045 Smooth / Wood Grain / White Wood Grain Rustic / Mahogany Series O Fiberglass Door INSWING / OUTSW►NG ,,immcr GENERAL NOTES 1. This product has been evaluated and is in compliance with the 7th Edition (2020) Florida Building Code (FBC) structural requirements including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHT'this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the "HVHZ" requiring wind bome debris protection, this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 5. For 2x stud construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. 7. Outswing configurations meet water infiltration requirements for "HVHT'. All other configurations do not meet the water infiltration requirements for the "HVHZ" and must be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. TABLE OF CONTENTS SHEET If DESCRIPTION SHEET# DESCRIPTION 1 Typical Elevations, Design Pressures & General Notes 8 Horizontal & Vertical Cross Sections (Direct to Masonry) 2 Door Panel Details 9 3-point lock details 3 Lite frame details and glazing details 10 3-point lock details 4 Horizontal & Vertical Cross Sections (2X Buck) 11 Buck and frame anchoring 5 Horizontal & Vertical Cross Sections (1X Buck) 12 Components 6 Horizontal & Vertical Cross Sections (Direct to Masonry) 13 Bill of materials 7 Vertical Cross Sections (Thresholds) 37.50" MAX. OVERALL FRAME WIDTH 0 Z Z_ 3 3 z M 0 L w aau, LL J w w o a 00co CONFIGURATION MAX ,FRAME..J D/MENSION.: DESIGM PRESSURE (PSF) -POSITIVE'. NEGATIVE':'. x 37.5" x 82.0" +75.0 -75.0 See sheets 2 & 4 for hardware and lite frame design pressure limitations Rn In gZ �Z 6g10 *''''r* '% oCmLh UN ••� � E v Z O Z K G Em m u N a mOa� g d -=i E 0 z u� w o° d onr[, 02116 12 SCALE: N.T.S. owO. B/: JK CHN. BY: I.FS Ft.-15210.4 eer 1 OF 13 0.7' CAP (PVC) HINGE STILE (LVL) EXTERIC .I INTERIO 2 HORIZONTAL CROSS SECTION 35.75" DOOR WIDTH 2 2 �J co :z 4 2 X 0 • SEE HARDWARE TABLE SEE HARDWARE TABLE 40 DOOR PANEL LATCH STILE (LVL) HARDWARE TABLE MANUFACTURER MORE! MAX DESIGN i .PRESSURE` (PSF KNOB: SIGNATURE SERIES KWIKSET * 75 DEADBOLT: SIGNATURE SERIES (980) SCHLAGE KNOB: "P'SERIES (F51) "B" ±75 DEADBOLT: SERIES (B60/62) PAMEX LEVER: FL311 SERIES ±75 DEADBOLT: FD7 SERIES HOPPE MULTIPOINT LOCK: HLS9000 3•POINTTONGUE ± 50 ENDURA MULTIPOINTLOCK: TRILENNIUM30D0(3•PT) ±75 See sheets 6 and 7 for multipoint lock details. TOP RAIL (COMP.) T T d INTERIOR a: FIBERGLASS SKIN a ' (0.125" MIN. THK.) FOAM CORE (POLYURETHANE- 1.9 PCF MIN.) EXTERIOR BOTTOM RAIL (COMP.) /',2_1 VERTICAL CROSS SECTION 2 z Omw PIP U �`�� z m z n p cv 9 E Em 0 x z m zm N o NM mm �pL a ^ \\\y r.i a a m d a T LL ti -=i E vz Cola c BS (li n Of o �0 o ON J J ag m Z a am i 4 0 �I 0O 0 0 a a SCALE: N.T.S. OWG. BY: JK CHK. BY: LFS DRAWING NO.: FL-15210.4 SHEET 2 OF 13 C J 24.22" MAX. .. /���� FRAME WIDTH 5/8"GLASS BITE �`PA, 20.50" MAX.' D.L.O. WIDTH S TRUCTURAL SILICINE (DOW 995) - =e `o;' x' N EXT. i--� 1" OVERALL GLASS THK. N 1.86" 1.86" %i yy` F N rn 1/8"ANNEALED GLASS i ....... '�i� � o o b O0.09D" SAFLEX®PVB�///*P1% `��`anm I,INTERLAYER 0 a6 1 /8"ANNEALED GLASS NEz o o m* AIR SPACE0 °a 0 a1/8" TEMPERED GLASS Nmaq Va(TYP') EXi FRAME INT. FRAME T a ALUMINUMSPACER A3 A4-'9z O CTURAL SEALANT °3/4"PPH SELF -DRILLING SMS INT. GLAZING DETAIL °'Ln io �o 4 O'nYwz �j CL m 4.25" i (TYP.) am_ a ODL LITE FRAME w o 0 0 24" MAX, a a FRAME WIDTH 20.75" MAX. �� m D.L.O. WIDTH �L� ona dj o00 EXT. N N N 1 /2" GLASS BITE �� A5 WWW o 1-1/4"OVERALL THK.GLASS STRUCTURAL SIUCINE(DOW995) Xt N 1/8"ANNEALED GLASS o 0 0 w x 0.090"SAFLEX®PVB w w w O 6 INTERLAYER ¢ a (nP') 1 /8" ANNEALED GLASS 1.59 ? $ AIR SPACE \ Qo �L 1/8"TEMPERED GLASS ^ ^ O fq d 1/2'NON-GROOVESWIGGLE N o W/ DELCHEM#80 POLYSULFIDE A7 40 02116112 1/8"BACKFILL A6 #10XI-3/4"PPH WOOD SCREW SCALE: N.T.S. GLAZING DETAIL EXL FRAME INT. FRAME SCREW CAP DING. BY: JK (NP) � �� INT. G2 A5 A6 A7 cHK. BY, LFS DRAWING NO.: RSL LITE FRAME FL-15210.4 SHEEP 3 OF 13 LREFRAMEiABLE MAX. DESIGN MANUFACTURER ,PRESSURE: $ ; ODL ± 75 RSL ± 60 a d v V C 3 3 3 5 6 ... `\\\AC • 4 5 6 8 8 ; !-Q.;- z .0 m m u \\ N 7 zo;a U C \\\v N OK E z m , O N m c w o as a poaaln Naga m X `LL c 0 u 0Z 1 4 O 4 `W o �d 2 1 5 5 / 2 �m 6 6 1 2 —o 8 8 �� aiz 3 4 D 4 1-1/4"MIN. v c' SW w rz w ol> 8 8 EMB. (TYP.) p, m r� E 1 2 3 2 1 of o 00 8, B C 7 7 D B U .4 L 0.15' C'SINK --- C D " m (TYP.) _ 0.15' C-SINK E ° o ° (nP) `a �Y �L n v ° 4 T m 1 2 p, v ona 0 ° INTERIOR N N N D B El Ea z o a 7 L 40 58 0 7 1a nN z 11 11 EXTERIOR 27 A INTERIOR DATE: 02 16/12 1-1/4'"MIN. L 9 E EXTERIOR o SCu-E: N.T.S: EMB. (TYP.) 40 ° DwG. BY: JK 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION 3 VERTICAL CROSS SECTION cHK, eY: LFS DRAWING NO.: q Outswing shown Inswing similar) q Outswing shown (Inswing SIM110T) 4 Outswing shown (inswing similar) FL-15270.4 SHEEP _�L OF 13 a T 0 V K 'N•, c OWN rnn L omen rn �•.'••. of z m z T U N m Z O Z K m N to 9 cw E u a o D. � mdam c 4 0 5 E oz A c V) E o �d C E 2 1 C '<m °v o° Ci0 �X ° ZO jam. O J 1 2 J J &�2 �z JO E > go ^ pcn am N 7 e� ° INTERIOR 40 o oI a G A moo] V mEE UU u� cl n d 40 NNN 11 EXTERIOR °w w w z 11 1 2 D EMB. MIN. 9 4p 27 G EXTERIOR o 0 o -' EMB. (TYP.) t-1/a" Mw. INTERIOR EMB. (TYP.) W- 1' 000 ana u HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION �3 VERTICAL CROSS SECTION o $ Shown w/ I sub -buck j Shown w/ 1X sub -buck g Shown w/ I sub -buck w Outswing shown (Inswing similar) Outswing shown (Inswing similar) Outswing shown (Inswing similar) N N O N o MN •-z [Dl DATE 02/16/12 z 0 SCALE: N.T.S. DWG. BY. JK m CHK. BY: LFS 3 DRAWING NO.: m FL-15210.4 0 SHEET S OF 13 Q' m a #.Z-- z rc'e��0� �'•. ��i ••'•......... 7a •�45`� It m d On a C4 .. m O 0 V � Z� e e Em mu o OM 5d0Q. '5 d m a 0 \\V= s o � c E 0 o wTo Lim E E N> Oc 2 C �0 C U K ¢� o ay. vo Q Zo �O D a 1 2 p p Z a >✓ O �o dm < Zcn 7 J o. O Nrz 7 �� M v INTERIOR 40 o ow Sin m C U U � n a 4O NNN EXTERIOR rn o 40 9 27 M rn EXTERIOR INTERIOR o 0 0 1-1/4 MIN. w EMB. (TYP.)¢p o¢ ¢o C, HORIZONTAL CROSS SECTION �21 HORIZONTAL CROSS SECTION �1 VERTICAL CROSS SECTION 6 Shown Direct to Masonry 6 Shown Direct to Masonry 6 Shown Direct to Masonry N N rn W a i Outswing shown (Inswing similar) Outswing shown (Inswing similar) Outsw ng shown (Insw ng similar) ^ n o DATE: 02116112 SCALE: N.T.S. ' OWC. BY: JK CHI. BY: LFS DRAWING NO.: T FL-15210.4 � SHEET 6 OF 13 • •6, x Loa M� �`�\\\ o m z U Cl •• W O N NK v 0 p Z� o Em Z m u NM 96La Na ,a maa�- _5 9 EXTERIOR INTERIOR E o= ] 9 U [IJ c 3a Of N 8 40 z_0 oN 29 O �" a5 U� ' I UEO �m W (n� W w 1=tn aIn < WO EXTERIOR INTERIOR c ` o w a o a C < a EXTERIOR INTERIOR o I 40 ao a a 9 a Qtl a a e a m m 30 31 32 33 34 40 2 VERTICAL CROSS SECTION 8 e IL w 7 Shown w! ADA threshold 36 37 NNN 38 www o E�� x rn w n e e E o00 e e o n a o a > p a- a a a a a n o00 > j:D z D ..49 d a d a G ' a Z t�V^� VERTICAL CROSS SECTION 7 Outswing confirguration 3 VERTICAL CROSS SECTION z ^ N �7 J Inswing configuration DATE: 02116112 z SME: N.T.S. D m DWG. BY, JK m CHK. BY: LFS 3 DRAWING NO, G: FL-15210.4 To SHEET —L OF 13 N Z d I,5" MAX. 5 VERTICAL CROSS SECTON $ Shown Direct to Masonry Outswing only w/ 4-9/16' jamb C in z z_ z4 ry INTERIOR 40 40 Uo a M 1-1/4" MIN. "' EMB. (TYP.) E _- _--\\ EXTERIOR 1-1 /4" MIN. EMB. PP.) 1 HORIZONTAL CROSS SECTION r2 HORIZONTAL CROSS SECTION $ Shown Direct to Masonry $ Shown Direct to Masonry Outswing only w/ 4-9/16'jamb Outswing only w/ 4-9/16'jamb Z n _ 1.5" MAX. w I MIN. 1.5° MAX. EXTERIOR _W INTERIOR r1 VERTICAL CROSS SECTION $ Shown Direct to Masonry Outswing only w/ 6-9/16jamb X i I rn Z op a N M D y. o 1-1/4" MIN. EMB. (TYP.) r3HORIZONTAL CROSS SECTION Shown Direct to Masonry Outswing only w/ 6-9/16'jamb INTERIOR EXTERIOR • ............. . ^� `dam' U M d z O`Nwmro 0m.0 Q Q C O \\\``` z o 10 U N •: y N N °n. t _ Oc ZZ m W O a rnn _g IL Rtm N < m rLdLL � T 9 4 c �z0 U 1-1/4"MIN. EMB, (TYP.) �DATE:02/16/123 E; N.T.S.4 HORIZONTAL CROSS SECTION eY. JK m $ Shown Direct to Masonry cHk. W. LFS Outswingonly w/6-9/16'jamb O.'0.; FL-15210.4 SHEET 8 OF 13 *�0�4 . AC . Z •C7 Z oo a �Y? •...... ''\\\ m 0 (7 0 �711 • I� 7 M] Z \ U N m tv m o rn 0 cQ E z ozrc m 0 0 N Ern m o °a 9 p o a .M, 0o 0 N ? ��°z a ma:0,a c ' o c o 0 0 Q 2X BUCK IXBUCK $$ G } I y o° �cU) 0 s DIRECTTO o O MASONRY M Q 4 o zo D c 23 pN a Y m = 2.17' gw n 2X BUCK 58 a HOPPEMULTIPOINTLOCKSET = 22 IX BUCK G 25 as O m m HL5900D&Point'Tongue' } DIRECT TO M a MASONRY m —►1 1.T' �— 2X BUCK $$ 1XBUCK G N N N DIRECT TO M 23 o d z MASONRY g w w o rn _ h � 22 W o00 z , cq STRIKE JAMB N N Q n � M p •v c+i DATE: 02 16 12 SCALE: N.T.S. j` ® DWG. BY: JK 0 cHx, eY: LFS MULi1POfNTS1RIKE PLATE LATCH AND DEADBOLTSTRIKE PLATE 25 DRAWING ND.: 23 Tongue system FL— 7 5210.4 MANUAL RAISED TONGUE GEAR SYSTEM SHEET J of 13 p�C; J.• w g, o AN M Z'•y: rz omw •'....fit Q ca;a g: IS p UN ••, O 55 U O Z K N �' z o B Ern om m ct & o00 d oa c CZ � o C w �d CC d O 0 Y KN j: VO O F4-s m J 0.W n Z 0. Ca O 4 0 UI 0 o � � a a a M ® mmm to N 0 57 NNN N 60 Z °ww O n b h W 62 00O K O OOD i 7 Z 2X BUCK 58 o n F N � � lal = 1XBUCK G NN Q c DIRECTTO M n i MASONRY n N111 • Z o° DATE: 02116112 z SCALE: N.T.S. 5 DWG. BY: JK m STRIKE JAMB DETAIL cHK. BY: LFS 3 ENDURATRILENNIUM3000 DRAWING ND.: m N 3 pt. Lock FL-15210.4 0 SHEET 1 D OF 13 (TYP.) y D TYP. HEAD —" &JAMBS 7 MASONRY OPENING 2X BUCK � U "2 o 0 BUCK ANCHORING CONCRETE ANCHOR NOTES: I. Concrete anchor locations at the comers may be adjusted to maintain the min. edge durance to mortarjoints. 2 Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to modarjolnts. additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: ANCHOR ANCHOR MIN. MIN. CLEARANCE MIN. CLEARANCE -. TYPE SIZE TO MASONRY TO ADJACENT`. .':EMBEDMENT: 'EDGE _ANCHOR :: IT TAPC ON ® 1/" 4 1.1/4" 2" 4" ELCO ULTRACON ® T/ " 4 1.1 /4" ITN, a TA PCON 3/16" 1.1/4" AS SHOWN 1.1/2, 1. WOOD SCREW INSTALLATION NOTES: Maintain a minimum 5/8"edge distance, I"end distance, & I"o.c. spacing of wood sueva to prevent the splitting of wood. 4-9/16" JAMB p DIRECT TO MASONRY JAMB (TYP.) (SEE SHEET 8) SEE HINGE L 2X BUCK o a DETAIL (TYP,) G 1X BUCK DIRECT TO D = MASONRY MASONRY M OPENING TYP. HEAD & JAMBS FRAME V 4-9/16" JAMB M — O 2X BUCK 6-9/16" JAMB N DIRECT TO r MASONRY JAMB (TYP.) (SEE SHEET 8) a ADA SILL ( ONLY STRIKE JAMB FRAME ANCHORING Masonry construction DIRECT TO DIRECTTO MASONRY M M MASONRY 28 1X BUCK G G 1X BUCK S 2X BUCK L 2X BUCK 58 58 2X BUCK IXBUCK 11 DIRECT TO M MASONRY 11 DIRECT TO 11 D MASONRY G 1XBUCK 27 / 58 2X BUCK LATCH & DEADBOLTDETAIL HINGE DETAIL Inswing DIRECT TO MASONRY 1 X BUCK 2X BUCK z*'g:dam . lY zz Lim 46 a n m U N ••� O a v 6 O O p z o m C N o a a Y By j W O a O ^ N maam 5 0 E oz ' c cW 3�d ^K� J z Of 0 za o z C)N L5 J w LnCD m am UI � p o Y F U Of m HINGE JAMB HINGE DETAIL Outswing ALE: N.T.S. G. BY: JK C BY: LFS WING NO.: FL-15210.4 CET_ 11 OF 13 F z I'W,T .' L". i 30ZOIITSWING THRESHOLD DLP (QOSR) 4.68" �100Z WING THRESHOLD DLP(QOSH) �i Ol1TSW1NG THRESHOLD @a Endura (Z•Series) gINSWING THRESHOLD Enduro (Z_Series) ,rWING THRESHOLD 4 Columbia High Dam (581) !V07fir li-mm"I'll, 1 M6� �;\ ODTSWING THRESHOLD "r Columbia (575) (gNSWING THRESHOL0 "� Columbia @INSWING THRESHOLD DLP (ISCS) O ry i f--2.44"2.13"— POLY FIBER JAMB Plasfpro lv F --- 2.36" 2.2' — 2 WOOD JAMB T 10 (Dj WEATHERSTRIP Endura Force 5 a 2.098" o 0 \DOOR BOTTOM SWEEP 4.56" :;;::�� 29 ADA THRESHOLD DLP A, 1N g."........ ch' m O o a \ \V CD N ° t0 o u a Na ri wy� LL T � 0 G W JTO. N M ZM J "^n Z 000 >°Z N n U N 0. z oz'. o m =p=n. mn:a� SCALE: N.T.S. owc. aY: JK cnk. By. LFS FL-15210.4 ET 12 of 13 Wp z / ��rrrriri �� — O M F Og, z °° O m ��`` o M m 6 BILL Of MATERIALS 3 e n, mr U N .. a LO O m C W a NM Os m a mdaw N 0 E vz N N p o s 0 U zo om a5 I� 4Go r a w m w o —61 Of m 0 O o a a E > > } m _ n mm� onv N N = > N W n W W b N z O N iaa 2 F = J � N O N n \\W q M M N ^ a z = Z ❑ DATE: 02/16/12 SCALE: N.T.S. ° DWG. BY: JK m' - CHK. BY: LFS 3 DRAWING NO.: � FL-15210.4 " 0 — SHEET 13 OF 13 N _ Q V ITEM 9 DESCRIPTION MATERIAL A 1 X BUCK SG >= 0.55 WOOD B 2X BUCK SG >= 0.55 WOOD C 1/4" MAX. SHIM SPACE - D 1/4" X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE G 3/i b" x 3-1 /4"PFH ITW CONCRETE SCREW STEEL I 1/4" X 1-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL J 1 /4" X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL K 1/4" X 2-1/4" ITW CONCRETE SCREW STEEL L #10 X 2-1/7' PFH WOOD SCREW (1.15"MIN. EMBEDMENT) STEEL M 3/i b" X 2-1 /4" ITW CONCRETE SCREW STEEL N 3/16" X 2-3/4" ITW CONCRETE SCREW STEEL P 1!4" X 2-1 /4"PFH ELCO CONCRETE SCREW STEEL 1 POLY FIBER JAMB COMP. /VINYL 2 FINGER JOINTED PINE FRAME WOOD 7 WEATHERSTRIP FOAM 8 DOOR BOTTOM SWEEP VINYL 9 4" X 4" BUTT HINGE STEEL 11 #9 X 3/4"PFH WOOD SCREW STEEL 22 3 POINT'TONGUE" MULTIPOINT LOCKSEi (Mfg. BY HOPPE) STEEL 23 MULTIPOINT STRIKE PLATE (TONGUE SYSTEM) STEEL 25 LATCH AND DEADBOLT STRIKE PLATE (TONGUE SYSTEM) STEEL 27 LATCH STRIKE PLATE STEEL 28 DEADBOLT STRIKE PLATE (SECURITY) STEEL 29 ADATHRESHOLD ALUM 30 OUTSWING THRESHOLD ALUM/WOOD 31 OUTSWING THRESHOLD ALUM/WOOD 32 OUTSWING THRESHOLD ALUM/WOOD 33 OUTSWING THRESHOLD ALUM/COMP 34 OUTSWING THRESHOLD ALUM/WOOD 36 INSWING THRESHOLD ALUM/COMP 37 INSWING THRESHOLD ALUM/WOOD 38 INSWING THRESHOLD ALUM/COMP 40 DOOR PANEL -SEE DOOR PANEL DETAIL SHEEP FOR CONSTRUCTION DETAILS - 55 #10 X 1-1/2"PFH SCREW STEEL 57 BACKING PLATE STEEL 58 #8 X 2"PFH WS STEEL 60 MULTIPOINT STRIKE PLATE STEEL 62 ENDURA TRILENNIUM 3000 LOCK ASSEMBLY STEEL