Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit Appl for 5316 Silver Oak Dr Additional
T. LUCIE section A (General Information) Master Permit No. Process No. Contractors Name: One construction & Roofing contractors License # 000-1330623 Job Address 5316 Silver Oak Dr Fort Pierce F134982 E Low Slope 0 Asphaltic Shingles ® New roof © Repair Low Slope Roof Area (SF) 364 sq ft ROOF CATEGORY Q Mechanically Fastened Tile M Metal Pane(/Shingles 0 Prescriptive BUR-RAS 150 ROOF ROOF TYPE. Q Maintenance ❑ Mortar/Adhesive Set Tiles ❑Wood Shingles/Shakes ® Reroofing -ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) 2016 sq. ft. C! Recovering Total (SF) 2380 sq ft Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. U R r"t€.. ((72 ( V ) ST. LE Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: POLYGLASS USA Product Approval No.: FL#1654-R27 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': -36 Zone 1: -36.1 Zone 2:-47.7Zone 3: -64.9 Max. Design Pressure, from the specific product approval system: Peel & stick / SBS-SA Deck: Type: Plywood Gauge Thickness: 19132 CDX Slope: 1/12" Anchor/Base Sheet & No. df Ply(s): N/A Anchor/Base Sheet Fastener/Bonding Material: N/A Insulation Base Layer: N/A Base Insultation Size and Thickness: N/A Base Insulation Fastener/Bonding Material: N/A Top Insulation Layer: N/A Top Insulation Size and Thickness: N/A Top Insulation Fastener/Bonding Material: SELF -ADHERING Base Sheet(s) & No. of Ply(s): 1 Base Sheet Fastener/Bonding Material: SELF -ADHERING Ply Sheet(s)' & No. of Ply(s): N/A Ply Sheet Fastener/Bonding Material: SELF -ADHERING Top Ply: 1 Top Ply Fastener/Bonding Material: SELF -ADHERING Surfacing: N/A Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—" oc @ Lap, # Rows @ "oc Zone 1:_" oc @ Lap, # Rows @ "oc Zone 2:r." oc @ Lap, # Rows @ "oc " Zone 3:_.._." oc @ Lap, # Rows @ "oc Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Section D (Steep Slope Roof System) Roof system Manufacturer: Extreme Metal fabricators, LLC Notice of Acceptance Number: FI # 17022-R8 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:-38.1 Zone 2e:-50.2 Zone 2n: 502 Zone 2r:-49.6 Zone 3e:-50.2 Zone 3r: -50.2 Deck Type: 19/32 CDX Plywood Type Underiayment; Owen cornings / Titanium Roof underlayment Roof Siope: 5 12 Insulation: N/A Fire Barrier: N/A iztdge Ventilation? Fastener Type & Spacing: #10 X 1.5" FASTENER WITH SEAL WASHER N/A #10 AT 16' O.0 Adhesive Type: N/A Type Cap Sheet: i N/A i Mean Roof- Height: 12' Roof Covering: 5V metal roof / 26 gauge Type & Size Drip ExGalvalume . I Edge: