HomeMy WebLinkAboutPermit Appl for 5316 Silver Oak Dr AdditionalT. LUCIE section A (General Information) Master Permit No. Process No. Contractors Name: One construction & Roofing contractors License # 000-1330623 Job Address 5316 Silver Oak Dr Fort Pierce F134982 E Low Slope 0 Asphaltic Shingles ® New roof © Repair Low Slope Roof Area (SF) 364 sq ft ROOF CATEGORY Q Mechanically Fastened Tile M Metal Pane(/Shingles 0 Prescriptive BUR-RAS 150 ROOF ROOF TYPE. Q Maintenance ❑ Mortar/Adhesive Set Tiles ❑Wood Shingles/Shakes ® Reroofing -ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) 2016 sq. ft. C! Recovering Total (SF) 2380 sq ft Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. U R r"t€.. ((72 ( V ) ST. LE Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: POLYGLASS USA Product Approval No.: FL#1654-R27 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': -36 Zone 1: -36.1 Zone 2:-47.7Zone 3: -64.9 Max. Design Pressure, from the specific product approval system: Peel & stick / SBS-SA Deck: Type: Plywood Gauge Thickness: 19132 CDX Slope: 1/12" Anchor/Base Sheet & No. df Ply(s): N/A Anchor/Base Sheet Fastener/Bonding Material: N/A Insulation Base Layer: N/A Base Insultation Size and Thickness: N/A Base Insulation Fastener/Bonding Material: N/A Top Insulation Layer: N/A Top Insulation Size and Thickness: N/A Top Insulation Fastener/Bonding Material: SELF -ADHERING Base Sheet(s) & No. of Ply(s): 1 Base Sheet Fastener/Bonding Material: SELF -ADHERING Ply Sheet(s)' & No. of Ply(s): N/A Ply Sheet Fastener/Bonding Material: SELF -ADHERING Top Ply: 1 Top Ply Fastener/Bonding Material: SELF -ADHERING Surfacing: N/A Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—" oc @ Lap, # Rows @ "oc Zone 1:_" oc @ Lap, # Rows @ "oc Zone 2:r." oc @ Lap, # Rows @ "oc " Zone 3:_.._." oc @ Lap, # Rows @ "oc Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Section D (Steep Slope Roof System) Roof system Manufacturer: Extreme Metal fabricators, LLC Notice of Acceptance Number: FI # 17022-R8 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:-38.1 Zone 2e:-50.2 Zone 2n: 502 Zone 2r:-49.6 Zone 3e:-50.2 Zone 3r: -50.2 Deck Type: 19/32 CDX Plywood Type Underiayment; Owen cornings / Titanium Roof underlayment Roof Siope: 5 12 Insulation: N/A Fire Barrier: N/A iztdge Ventilation? Fastener Type & Spacing: #10 X 1.5" FASTENER WITH SEAL WASHER N/A #10 AT 16' O.0 Adhesive Type: N/A Type Cap Sheet: i N/A i Mean Roof- Height: 12' Roof Covering: 5V metal roof / 26 gauge Type & Size Drip ExGalvalume . I Edge: