BLOWER DOOR TEST FORM
House Infiltration Test Certification -1 1 "'4' A
Prescriptive and Performance Method
Date: (Z �� 2, tj Permit #: 2 (`' 2- - O � 3
Contractor:
Job Address:
Construction: (\/I New Construction - Complete ( ) Existing -After Addition
House Infiltration Test Results SLC Climate Zone 2
CFM (50) = 1- O ")6 Test Date: �f I Z o1r
Volume = 2 0 !f-- 4 3
ACH (50) = CFM (50) x 60 / Volume = __
Passing results must be & ACH (50) or less
Mechanical Ventilation required less than 3 ACH
(,Vpass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blowerdoor at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit Is less than 3 air changes per hour when tested with a blower door at a
pressure of 02 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florido Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation In accordance with Section M1507.3,
Testing Company
Company Name: Pro-Di1Ct Services Address: 1915 Rlo Vista Drive. Ft, Pierce, FL 34949
1 hereby certify that the above mouse Infiltration results demonstrate compliance with FBC Energy Conservation
requirements In accordance with Section R4.02,4,1.2 Climate Zone 2.
Signature:
Printed Name: Martin Klein
License/Certification #: 6061033