Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(1718.3 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11 A 240.00 ft2 c. NIA R= ft2 4. Number of Bedrooms 1 d. NIA R= ft2 5. Is this a worst case? Yes 11. Ceiling Types(1336.0 sgft.) Insulation Area 6. Conditioned floor area above grade (ft2) 1306 a. Under Attic (Vented) R=30.0 1306.00 ft2 Conditioned floor area below grade (ft2) 0 b. Knee Wall (Vented) R=19.0 30.00 ft2 c. N/A R= ftz 7. Windows(128.9 sgft.) Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Sgl, U=1.02 76.04 ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 SHGC: SHGC=0.29 b. b. U-Factor: Sgi, U=1.03 40.00 ft2 C. SHGC: SHGC=0.27 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: Sgl, U=1.02 12.85 ft2 a. Central Unit 29.0 SEER:14.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 14. Heating Systems kBtu/hr Efficiency S. Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor.(AVG) NIA N/A ft2 SHGC(AVG): N/A 9. Floor Types Yp Insulation Area 15. Hot Water Systems a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 ft2 a. EleciricTankless Cap: 1 gallons b. N/A R= ft2 EF. 0.600 c. N/A R_ ft2 b. Conservation features NoneNone 16. Credits Glass/Floor Area: 0.099 Total Proposed Modified Loads: 41.30 Total Baseline Loads: 43.21 PASS 1 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this'l!Ts( Code. calculation indicates compliance with the Florida Energy Code- ri�i x PREPARED BY: B/Frrr�, •,, `'�'' 4 efore construction is completed DATE.-"�®2 1 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. . with the Florida Energy Code: OWNER/AI�)T: DATE: ` , BUILDING OFFICIAL: _. DATE: - Cemnliannerarlidrunr-or+if.-�f:.,..F.,fc..-----�--. „Zlm-1..lhit inailuiaakurertnaimeair nanaierenclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNET/ICC 380, is not greater than 0.000 On for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 6/7/2021 11:47:00 AM EnergyGaugeO USA 7.0-00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE COTTAGE IMPACT Address type: Street Address Building Type: User Bedrooms: 1 Lot#: - Owner: WYNNE BUILDING CORP. Conditioned Area: 1306 Block/SubDivision: - TotalStories: 1 PlatBook: - BuilderName: WYNNE BUILDING CORP. Worst Case: Yes Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY Rotate Angle: 180 County: St Lucie Jurisdiction: CrossVentilation: No City, State, Zip: FT. PIERCE, Family Type: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban YearConstruct: Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Dailytemp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range _FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 13IM76.2001953125 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _ 1 MASTER BEDROOM 234 1895.4 No 0 1 Yes Yes Yes _2 DEN 144 1166.4 No 0 Yes Yes Yes _3 SINK AREA 42 340.2 No 0 Yes Yes Yes _4 CLOSET 63 510.3 No 0 No Yes Yes _5 GREAT ROOM 452 3661.2 No 2 Yes Yes Yes _6 MASTER BATH 50 405 No 0 Yes Yes Yes _7 POWDER 25 202.5 No 0 No Yes Yes _8 KITCHEN 232 1879.2 Yes 0 Yes Yes Yes _9 LAUNDRY 40 324 No 0 No Yes Yes _10 STORAGE 24 192 No 0 0 Yes Yes Yes FLOORS (Total Exposed Area = 1306 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Ins MASTER BEDROOM 31 0 234 ft 0.473 - 0.00 1.00 0.00 _ 2 Slab -On -Grade Edge Ins DEN 24 0 144 ft 0.473 - 0.00 1.00 0.00 _3 Slab -On -Grade Edge ins SINK AREA 7 0 42ft 0.473 - 0.00 1.00 0.00 _4 Slab -On -Grade Edge Ins CLOSET 1 0 63ft 0.473 - 0.00 1.00 0.00 _5 Slab -On -Grade Edge Ins GREAT ROOM 32 0 452ft OA73 - 0.00 1.00 0.00 _ 6 Slab -On -Grade Edge Ins MASTER BATH 5 0 50 it 0.473 - 0.00 1.00 0.00 _7 Slab -On -Grade Edge Ins POWDER 1 0 25ft 0.473 - 0.00 1.00 0.00 _8 Slab -On -Grade Edge Ins KITCHEN 38 0 232 it 0.473 - 0.00 1.00 0.00 _ 9 Slab -On -Grade Edge Ins LAUNDRY 1 0 40 ft 0.473 - 0.00 1.00 0.00 _10 Slab -On -Grade Edge Ins STORAGE 21 0 24ft 0.304 - 0.00 0.00 1.00 6,71202111:47:00 AM EnergyGauge®USA 7.0.00- FlaRe52020 FBC 7th Ed ition (2020) Compliant Software Paget FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color ,Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1376 ft' 0 IF Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (I in) Area RBS IRCC 1 Fullattic Vented 150 1306 ft2 N N CEILING (Total Exposed Area = 1336 sq.ft.) # CeilingType Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type _ 1 UnderAtGc(Vented) MASTER BEDROOM 30.0 Blown 234.Oft- 0.053 0.10 Wood _2 UnderAttic(Vented) DEN 30.0 Blown 144.Oft- 0.053 0.10 Wood _3 UnderAttie(Vented) SINK AREA 30.0 Blown 42.0f 2 0.053 0.10 Wood _4 UnderAttic(Vented) CLOSET 30.0 Blown 63.Oft- 0.053 0.10 Wood _5 UnderAttic(Vented) GREAT ROOM 30.0 Blown 452.0ft- 0.053 0.10 Wood _6 UnderAttic(Vented) MASTER BATH 30.0 Blown 50.OIt' 0.053 0.10 Wood _7 UndefAttie(Vented) POWDER 30.0 Blown 25.0ft- 0.053 0.10 Wood _8 UnderAtic(Vented) KITCHEN 30.0 Blown 232.Oft- 0.053 0.10 Wood _9 UnderAttic(Vented) LAUNDRY 30.0 Blown 40.Oft- 0.053 0.10 Wood _ 10 UnderAtfic(Vented) STORAGE 30.0 Blown 24.0ft- 0.030 0.11 Wood 11 Knee Wall(Vented) GREAT ROOM 19.0 Blown 30.Oft' 0.045 0.11 Wood WALLS (Total Exposed Area = 1718 sq.ft.) Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the "Project" section on page 1. VAdjacent Cavity Width Height Area U- Sheath Frm. Solar Below # Omt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade 1 S=>N Exterior Cone. BIk- Int Ins MASTER BEDROOM 4.1 18.0 0 8.0 1 145.5 0.149 0 0 0.30 0% _2 W=>E Exterior Conc.BIk-Intlns MASTER BEDROOM 4.1 13.0 0 8.0 1 105.1 0.149 0 0 0.30 0% _3 N=>S Exterior Cone. Blk- Intlns DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _4 W=>E Exterior Cone. BIk- Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _5 S=>N Exterior Cone. Bik- Intlns SINKAREA 4.1 7.0 0 8.0 1 56.6 0.149 0 0 0.30 0% _ 6 N=>S Exterior Cone. Blk - Int Ins GREAT ROOM 4.1 22.0 0 8.0 1 177.8 0.149 0 0 0.30 0% _ 7 W=>E Exterior Cone. BIk- Int Ins GREAT ROOM 4.1 10.0 0 8.0 1 80.8 0.149 0 0 0.30 0% 8 S=>N Exterior Cone. Blk - Int Ins MASTER BATH 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _ 9 N=>S Exterior Cone. BIk- Int Ins KITCHEN 4.1 17.0 0 8.0 1 137.4 0.149 0 0 0.30 0% _10 E=>W Exterior Cone. Blk- Intlns KITCHEN 4.1 16.0 0 8.0 1 129.3 0.149 0 0 0.30 0% _ 11 S=>N Exterior Cone. BIk- Int Ins KITCHEN 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _ 12 N=>S Exterior Cone. Bilk - Int Ins KITCHEN 4.1 35.0 0 8.0 1 282.9 0.149 0 0 0.30 0% _ 13 N=>S Exterior Cone. BIk -Int Ins STORAGE 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _ 14 N=>S Exterior Cone. Blk - Int Ins STORAGE 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.30 0% _ 15 N=>S Garage Frame - Wood MASTER BEDROOM 11.0 30.0 0 8.0 0 240.0 0.092 0 0.23 0.30 0% DOORS (Total Exposed Area = 20 sq.ft.) Width Height # Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area 1 E=>W Insulated KITCHEN None 0.32 3.00 0 6.00 8 20.Oft- 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 129 sq.ft.) Wall -Overhang-- ✓# Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening -1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N N 32.4ft 1.0 ft 5 in 1.0 ft 5 in None None _ 2 W=>E 4 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft 1.0 ft 5 in 1.0 ft 5 in None None _ 3 N=>S 6 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft2 1.0 ft 5 in 1.0 ft 5 in None None -4 W=>E 7 Metal Low-E Single Yes 1.03 0.27 N N 40.Oft2 12.0 ft 0 in 1.0 ft 5 in None None -5 S=>N 8 Metal Low-E Single Yes 1.02 0.29 N N 6.9ft- 1.0 ft 5 in 1.0 ft 5 in None None 6 E=>W 10 Metal Low-E Single Yes 1.02 0.26 N N 12.8ft2 1.0 ft 5 in 1.0 it 5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00026 881 48.35 90.78 0.0907 5.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation _ 1 280 ft2 280 ft2 35 ft 8 ft 11 MASS # Mass Type Area Thickness FurnitureFraction Space _ 1 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 MASTER BEDROOM _2 Default(Blbs/sq.ft.) Oft• Oft 0.30 DEN _3 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 SINK AREA _4 Default(8lbs/sq.fL) 0 ft2 0 ft 0.30 CLOSET -5 Default(8lbs/sq.ft.) 0 ft2 0 It 0.30 GREAT ROOM 6 Default(8lbs/sq.ft.) 0 ft2 0 it 0.30 MASTER BATH _7 Default(81bs/sq.ft.) Oft• Oft 0.30 POWDER -8 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 KITCHEN _9 Default(8lbs/sq.ft.) Oft• Oft 0.30 LAUNDRY -10 Default(8lbs/sq.ft.) 0ft2 Oft 0.30 STORAGE HEATING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity -Geothermal HeatPump- Ducts Block kBtu/hr Entry Power Volt Current -1 Electric Heat Pump Split/Single HSPF: 8.20 27.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block kBW/hr cfm _1 Central Unit Split/Single SEER:14.0 29.0 0 0.80 sys#1 1 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric Tankless Garage 0.60 (0.60) 1.00 gal 61 gal 120 deg Standard None 82 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR OtherCredits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS VDuct ----Supply----- ------Return------ Air CFM 25 CFM 25 HVAC # # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT ON RLF Heat Cool _ 1 Attic 6.0 120 ft' Attic 6.0 45 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling []Jan []Feb [j Mar []Apr []May [)]Jun [)]Jul [XI Aug [)]Sep []Oct []Nov Dec Heating [)] Jan [X] Feb [X] Mar [ ] Apr [ ] May [] Jun [ ] Jul [I Aug [ ] Sep [] Oct [)] Nov [X] Dec Venting [ ] Jan [] Feb [X] Mar [)] Apr [ ] May [ ] Jun [] Jul [ ]Aug [ ]Sep [X] Oct [)] Nov [ ]Dec VThermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 _Cooling(WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 _ Heating (WD) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 _ Heating (WEH) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner. WYNNE BUILDING CORP. Jurisdiction: U Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air bamershall beinstalled in the building envelope. Air-permeableinsulationshall requirements The exterior thermal envelope contains a continuous airbarrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior thermal envelope insulation forframed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rimjoists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation, maintain permanent contact with the underside of above -garage subfloordeckin ,or floor framing g cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) ofsheathing, orcontinuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawlspacewalls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class l vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Ductshafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cevifies Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garageseparation Air sealing shall be provided between the garage and conditionedspaces. Recessedlighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Showerttub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exteriorwall and tubs shall separate them from the showers and tubs. beinsulated. Electrical/phonebox The air barriershall be installed behind electrical or on exteriorwalls communication boxes or air -sealed boxes shall be installed. HVAC register boot HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. in addition, mspecdon of log wans snail be in accordance with the provisions of ICC-400. 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ftz) Conditioned floor area below grade (ftz) 7. Windows" Description a. U-Factor. Sgl, U=1.02 SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.03 SHGC: SHGC=0.27 c. U-Factor. Sgl, U=1.02 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: Area Weighted Average SHGC: THE COTTAGE,FT. PIERCE,FL, New (From Plans) 10. Wall Types(1718.3 sqft.) Insulation Area Detached a. Concrete Block- Int Insul, ExteriorR=4.1 1478.30 ftz b. Frame - Wood, Adjacent R=11.0 240.00 ftz 1 c. N/A R= ftz 1 d. N/A R= ftz Yes 11. Ceiling Types(1336.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ftz 1306 b. Knee Wall (Vented) R=19.0 30.00 ftz 0 c. WA R= ftz Area 12. Ducts, location & insulation level R ftz 76.04 ftz a. a. Sup: Attic, Rat: Attic, AH: Attic 6 120 b. 40.00 ftz C. 13. Cooling Systems kBtu/hr Efficiency 12.85 ftz a. Central Unit 29.0 SEERA4.00 8. Skylights Description U-Factor.(AVG) N/A SHGC(AVG): N/A 9. Floor Types Insulation a. Slab -On -Grade Edge Insulation R= 0.0 b. N/A R= c. N/A R= 4.701 ft 0.281 14. Heating Systems kBtu/hr Efficiency Area a. Electric Heat Pump 27.0 HSPF:8.20 N/A ftz 15. Hot Water Systems Area 1306.00 ftz a. ElectricTankless Cap: 1 gallons ftz EF: 0.600 b. Conservation features ftz None 16. Credits None 1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: &� ( Address of New Home: THE COTTAGE City/FL Zip: a ';��Iz \ C� sa *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 ® Project SummaryJob: wrightsoftEntire House BY QUICK CALCS, INC. 317ST. LUCIE LANE, FORTPIERCE,FL34946 Phom:772-466-6799 Email: QUICKCALCS@AOL.COM For: WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL Notes: Design Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db OF Inside db 70 OF Inside db 7755 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16327 Btuh Structure 15522 Btuh Ducts 4013 Central vent (0 din) 0 Btuh Btuh Duds Central vent (0 cfm) 5251 0 Btuh Btuh none Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20340 Btuh Use manufacturers data n Infiltration Rate/swingg multipplier Equipmerrtsensibleload 0.95 19734 Btuh Method Simplified Construction Latent Cooling Equipment Load Sizing quality Average Fireplaces 0 Structure 2094 Btuh Ducts 1524 Stuh Central vent (0 clim) 0 Btuh Heatingg Area(fF) Coolinss (none) 1306 1306 Equipment latent load 3618 Btuh Volume (ft) 10579 10579 Airchanges/hour 0.45 EquivAVF(cfrn) 79 0.23 41 Equipment Total Load (Sen+Lat) 23352 Btuh Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CHI4NBO3000GOA0 Cond CH14NB03000GOA0 AHRI ref 9162387 Coil FX4DNBO43L Efficiency 8.2 HSPF AHRI ref 9162387 Efficiency 11.5 EER,14 SEER Heating input Sensible cooling 20300 Btuh Heating output 28000 Btuh @47-F Latentcooling 8700 Btuh Temperature rise 26 OF Total cooling 29000 Btuh Actual airflow 967 clm Actual airflow 967 cfm Air flow factor 0.048 cfm/Btuh Airflowfador 0.047 cim/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point = 34 OF Backup: Input=5 kW, Output=18005 Bluh, 100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrFJ%Pr!J t" 2021.1arM21321.40 Rigtt-SUte®UriwrMI201919.021 RSU08101 Page 1 ...\Wrigt6Dft WAC1WYNNEBUIDLING-THECOTTAGE.np Calc=MI8 Fmrt DoorPaas SW wrighWoW Right -A) Worksheet Job'. Entire House Date: QUICK CALCS, INC. By 317 ST.. LUCIE LANE, FORT PIERCE, FL34946 Prow: 72466-6799 Email:QUICKCALCS@AOLCOM 1 Room name Entire House MASTER BEDROOM 2 EVosedwall 145A ft 31.0 ft 3 Room height 8.1 ft 8.1 ft heall000l 4 Room dimensions 13.0 x 18.0 ft 5 .Room area 1306.0 IF 234.0 W Ty Con5.ruction U-value Cr HTM Area h) Load number, (BWhAF--°F) (BLIMP) or perimeter (ft) (B or perimeter (ft) (BWh) Heat Cool Gross NIPS Heat Cool Grass N/PIS Heat Cool 4 6 M/ 13A4= 0.143 n 4.00 2.19 446 427 171C 934 0 0 0 0 �C 2glaarg,droutr. 1.040 In 29.12 21.68 18 0 537 400 0 0 0 0 Y+1 13A4o s 0.143 e 4A0 2.19 162 129 516 282 0 0 0 0 IL— 2glaang,droutr, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 11 11DO 0.390 a 1022 10,34 20 20 223 211 0 0 0 0 N/ 13A4c s 0.143 s 4.00 2.19 284 277 1107 605 w 146 584 319 I—G 2glaang,droutr, 1.040 s 29.12 21.68 7 7 202 150 0 0 0 0 13A4= 0.1431 w 4.00 2.19 284 192 767 419 105 73 291 159 1Aclom 1270I w 35.56 34.7 41 41 1451 1419 0 0 0 0 1A-h1om 1270 w 35.56 61.76 18 3 656 1139 0 0 0 0 1A-htom 1270 w 35.56 63AO 33 5 1162 2072 33 5 1162 2072 C 16C-30m1 0.032 - 090 128 1306 1306 1170 1672 234 234 210 300 F 22A-tpl 0989 - 27.69 0.00 13N I 145 4015 0 234 31 858 0 6 c)AEDe=mon 3591 997 Ern2lopelossigain 13885 13393 3105 3947 12 a) Infiltration 2441 668 522 143 b) Rcommanfilahm 0 0 0 0 13 Intamal gains Oompants@ 230 2 460 0 0 Appiimoesbt w 1000 0 Subtnal(lines6tr13) 16327 15522 3627 3990 LeweaL-mallcad 0 0 0 0 I Less4ansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtatal 16327 15522 3627 3990 151 Dudioads 25% 34% 40t3 5251 25% 34% 892 1352 Total room load 20340 2073 4518 5342 Air required(cfm) 967 967 215 249 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed 20214ar 121321:40 RigttSute@ Uriwx 1201919.021 RSU08101lak Page 1 ...1Wrigt%oftHUAC\WYNNESUIDLING-7HECOT AGE.nn Calc=Ml8 FrortDoorfaces:SW F�d wrotsoft RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore: 772466-6799 Email: QUICKCALCS AOL.COM 1 Roommme DEN SINKAREA 2 Evoredmil 24.0 It 7.0 It 3 Room height 8.1 ft he Vmol 8.1 It heaVmol 4 Room dimensans 12.0 x 12.0 It 6.0 x 7.0 It 5 Room area 144.01E 42.0 IF Ty Construction U-value Or HTM Area Load Area (fF) Load number (BwhAF-'F) (Btuh4F) or perimeter (ft) (Btuh) or perimeter (ft) (BWh) Heat Cool Gros N/PIS Heat Cool Gross N/P/S Heat Cool 6 lM 13AAM 0.143 n 4.00 2.19 97 97 389 213 0 0 0 0 �G 2glaarg,droutr,. 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 13A4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 f-G 2glaang,drour, 1.040I a 29.12 39.42 0 0 0 0 0 0 0 0 11 I-D 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 W 13AAc s 0.143 s 4.00 2.19 0 0 0 0 57 67 227 124 �G 2glaang,droutr, 1A40 s 29.12 21.68 0 0 0 0 0 0 0 0 13AAo s 0.143 w 4.00 2.19 97 79 315 172 0 0 0 0 1Aclom 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 to-hlom 1270 w 35.56 61.76 18 3 656 1139 0 0 0 0 1A-hlom 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 1613.901"11 0.032 - 0.90 128 144 144 129 184 42 42 38 54 F 22AAPI 0.989 - 27.69 0.00 144 I 24 665 0 42 7 194 0 6 c)Amexgmion 574 3 Enoalopelossyain 2154 2283 459 175 12 a) Infiltration 404 111 118 32 b) Roomeentilafion 0 0 0 0 13 Internal gains: Ocwpants@ 230 0 0 p 0 Appliancesrolher 0 0 Subtotal (lines6h113) 2558 2394 576 207 Lessextemalload 0 0 0 0 Lewranser 0 0 0 0 Redisinbuton 0 0 0 0 14 Subtotal 2558 2394 5 207 15 Dudloads 25% 34% 629 811 25% 345/6 14242 70 Tot31 room load 3187 3205 1 718 278 Air required (dm) 152 149 34 13 • Calculations approved bvACCAto meet all requirements of Manual J 8th Ed •r wr4ghrsofe- RigrtSUte®Ud201919.021 RSU081 -.\Wdgt6oft HVApWYNNE BUIDLING-THE COTTAGE.AGE.np Calc=M18 Frort Do 2021-Jan-121321:40 fa or®s SW Page 2 wrlghtsoft• Right-J® Worksheet Deb: Entire House Date: QUICK CALCS, INC. By, 317ST. LUCIEL.4NE,FORr PIERCE. FL34946 Pnre:772466-6799 Email: QUICKCALCS@AOL.COM 1 21 Room name Expoaadwall CLOSET GREAT ROOM 0 ft 32A ft 3 Room hei hf 9 8.1 ft heat/mol 8.1 ft heaV000l 4 Room dimensons 9.0 x 7.0 R 1.0 x 452A ft 5 Room area 63.0 IF 452.0 IF Ty Construr9on U-value Or HTM Area (ff) Lead Load number (BWhr--°F) (BWW or perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat Cool Grose NIPS Heat Cool Gros N/P/5 Heat Cool 6 Y�C 13AAos 0.143 n 4.00 2.19� 0 0 0 0 178 160 640 350 2glaarg,droutr, 13A4= 1.040 0.143 n a 29.12 4.00 21.68 2.191 0 0 0 0 0 0 0 18 0 0 537 400 2glaagg,droutr, 1D40 a 29.12 39.42� 0 0 0 0 0 0 0 0 0 0 0 11 1100 0.390 a 1092 10,34 0 0 0 0 0 0 0 0 0 13A G 2glaang,droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 13AAocs 0.143 w 4.00 2.19 0 0 0 0 81 40 161 88 1Aotom 1270 w 35.561 34.77 0 0 0 0 41 41 1451 1419 1A-h1om 1270 w 35S6I 61.76 0 0 0 0 0 0 0 0 1A.htom 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 16C30m1 0.032 - 0.90 128 63 63 56 81 452 452 405 579 F I22A-tpl 0.989 - 27.69 0.00 63 0 0 0 452 32 886 0 6 c)AED exalrson -1 2069 Envelope los9gain 56 80 4080 4903 12 a) Infiltration 0 530 148 b) Roomventilabon 0 0 0 13 Internal gains: O=pants@ 230 0 0 2 Appliance.4ot q60 0 0 SubbbI(lines6to13) T14 80 4619 5511 Lesexamal load 0 0 0 Lestransler 0 0 0 RedistribiAon 0 0 0 14 Subbtl 80 4619 5511 15 Dudloads 25% 34%27 25% 34% 1135 18W Total room load Airrequired(dm) 70 107 5754 7379 3 5 274 343 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed - wr�ghisoR- `t ... Rig Ar 919.02101 2021J121321:40 \WngttoftHVACWYNNEBUIDLIN-THFCOTTGE.rLp CaIc=MI8 FmnDoorfarxsSW Page 3 r}r wrightsofr Right- J@ Worksheet Jcb: Entire House Dy. By. QUICK CALCS, INC. 317 ST. LUCE LANE, FORT PIERCE, FL34946 Ptore:772-0666799 Emil: QUICKCJLLCS@AOL.00M 1 Room name MASTER BATH POWDER 2 Erpcmdwall 5D ft 0 ft 3 Room height &1 It heallmol 8.1 It IxaNmol 4 5 Roan dim vao Rpomarea Ion x 5,0 It 5oD IF 5,0 x 5D ft 25.0 fF TY Construction U-Value or HTM Area (fly Load rea A(ff) Load numbs (BWhAF-'q (BWW a pen star (t) @Wh) or perimeter (ft) (BWh) Heat Cool Gros NIPS Heat Cool Gross NIPS Heat Cool 6 WL 13A-4= 2ghong,droutr, 13A ccs 0.143 1D40 0.143 n n a 4.00 29.12 4D0 2.19 21.68 2.19 0 0 0 0 0 0 0 0 0 0 0 0 0 - 0 0 0 0 0 0 0 0- 0 0 0 11 IG D 2gWaW ng,dra, 11130 1D40 0390 a a 29.12 10.92 39.42 1034 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 13A-4as 2glaarg,dreutr, 0.143 1D40 s a 4D0 29.12 219 21.68 41 7 34 7 134 202 73 150 0 0 0 0 0 0 0 0 L— 4y 13A4as w 4D0 0 0 0 0 0 0 0 0 1A-hI= 1Ah1om 1270 1270 1270 w w 3556 3556 4.77 81.76 61.76 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 IA-hlom 12M w 3556 63.40 0 0 0 0 0 0 0 0 C - - 16C-3Dml 0.= - 090 128 50 50 45 64 25 25 - 22 32 F 22W o.W - 27D9 ODO I 50 i 5 138 0 25 0 0 0 6 c)AED e=rsa 1 4 1 1 0 Envelope los (gain 520 284 22 32 12 a) Match 84 23 0 0 b) Rcomuenfilation 0 0 0 0 13 Intarrlal gains Occupants@ 230 0 0 0 0 Applian esiother 0 0 SubtAW(lines61D13) 604 307 22 32 Less odernal load 0 0 0 0 Lestrarder Redi<Libulion 0 0 0 0 0 0 0 0 14 SubWmk 604 307 22 32 15 Ductlows, 25% 34% 148 104 25% 34% 6 11 Total room icad Air required (din) 752 36 411 19 - 28 1 42 2 Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed ■'Id- w Oftcwit- 2021-Jar-121321:40 Aft,.Ri9t6SdteOUriVersa1201919.021 RSU08101 Page -.\Wrigtlsoft HVAC\WYNNEBUIDLINC-TECOTrAGE.np Calc=MI8 Fmrt DUorracaa SW t1 wrightsofi° Right-® Worksheet Job; Entire House By. By. QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34M Phore: T72-466-6799 Email: QUICKCALCS@AOL.COM 1 Roommme KTCHEN LAUNDRY 2 E)posdwall 38.0 ft 0 ft 3 Room height 8.1 ft heWl=l 8.1 ft heaVoxl 4 Room dimensions 1.0 x 232.0 ft 4.0 x 10.0 ft 5 Room area 232.0 ft2 40.0 T Ty Construction U-lalue Or HTM Area OF) Load Area (W) Load number (BWhd2-°F) (BWhil6) or perimeter (ft) (BNh) or pedmeter (ft) (Bluh) Heat Cool Gros N/P/S Heat Cool Gross N/P/S Heat Cool 6 V"13A-4ps 0.143 n 4.00 2.19 138 138 551 3D1 0 0 0 0 2glaang,droutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 13A-4os 0.143 a 4.00 2.19 130 97 387 211 0 0 0 0 2glaang,droutr, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 11 D 11D0 0.390 a 10.92 10.34 20 20 223 211 0 0 0 0 t-G la44= 0.143 s 4.00 2.19 41 41 162 89 0 0 0 0 2glaarg,droutr, 13A4o s 1Aclom 1.040 0.143 1270� s w w 29.12 4.00 3556 21.68 2.19 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W �C I`-CG 1A-hlom 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 IA-hlom 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16C-30ml 0.032 0.90 128 232 232 208 297 40 40 36 51 F E 22A-tpl 0.989 - 27,69 0.00 232 38 1052 0 40 0 0 0 6 c)AED e=ram -37 -1 Enuelope los4gain 2951 1570 1 36 51 12 a) Infiltration 640 175 0 0 b) Roomeentila4on 0 0 0 0 13 Internal gairs: O=pants@ 230 0 0 0 0 Appliances(other 1000 0 Subb&(lines6to13) 3591 2745 36 51 Lese)temalload 0 0 0 0 LestrarLfer 0 0 0 0 Redistribubm 0 0 0 0 14 Subtotal 3591 2745 36 51 15 Dudloads 25% 34% 883 931 25%1 340/6 9 17 Total room load Air reguired(cim) 1 4474 213 3676 171 45 2 68 3 Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed 2021-Jart121321:40 RigftSute9Uriv rsa1201919.021 RSU08101 A&A ...\,dgttoRWAaWY NEBUIDLING-THECOTTAGE. Calc=tJJB FrortDoorfa.SW Page wrightsoft° RighWO Worksheet Job: Entire House Date: QUICK CALCS, INC. By, 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore: 772466-6799 Email: QUICKCALCS ,AOL.COM 1 Room name STORAGE 2 EVosedwall 8.0 ft 3 Room height 8.1 ft heayocol 4 Room dimensore 4.0 z 6.0 ft 5 Room area 24.0 T Ty Construction U-value Or HTM Area (fF) Load Area Load number (BWh/ft--g (BluW) or perimeter (1) (BGrh) or perimeter Heat I Cool G. NWP/S Heat Cool G. N/P/S Heat Cool 6 VIl 13A-4ocs 0.143 n 4.00 2.19 32 32 130 71 �G 2glaarg,droutr, 1.040 n 29.12 21,68 0 0 0 0 13A-0as 0.143 a 4.00 2.19 32 32 130 71 2glaang,droutr, 1.040 a 29.12 39.42 0 0 0 0 11 11DO 0.390 a 10.92 10.34 0 0 0 0 W 13A-0as 0.143 s 4.00 2.19 0 0 0 0 t-G 2glazig, droutr, 1.040 s 29.12 21.68 0 0 0 0 13A4ors 0.143 w 4.00 2.19 0 0 0 0 1Aclom 1270 w 3556 34.77 0 0 0 0 1A-hlom 1270 w 3556 61.76 0 0 0 0 1A-h1om 1270 w 35.56 63.40 0 0 0 0 C 16030ml 0.032 - 0.90 128 24 24 22 31 F I 22A-tpl 0989 - 27.69 0.00 24 8 222 0 6 c) AED e=rscn .3 Envelope loss/gain 502 170 12 a) Infiltali 135 37 b) Roomventlaton 0 0 13 Intemalgairs: Oompanls@ 230 0 0 Appliano=_shmer 0 SubMal(lines6to13) 637 207 LesseAemalload 0 0 Lesstranster 0 0 Redistributon 0 0 14 Sublotsl 637 207 15 Ductloads 25% 29% 157 60 Total room load 794 266 Air required (cfin) 38 12 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed 2021-Jan-121321:40 RigrtTHE CJ T-rAGE.np 919.02t R FortD1 Page6 ...\WrigFEoftHVACIWYNNE BUIOLING-THE COTiAGE.np CaIc=MIB FrortDoorfao;s:SW Duct System Summary Date: wrightsoft SDate: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34M Ph w772466-6799 Em il:QUICKCALCS@AOL.COM Project Information For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply/return available pressure Lowest fdcUon rate Actual airflow Total efective length (TEL) Heating 0.50 in H2O 028 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 cftn 126 Supply Branch Detail Table Cooling 0.50 in H2O 028 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 cfm Name Design (Btuh) Htg (CIM) Clg (Cfm) Design FR Diam (in) H x W (in) Dud mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk CLOSET C 107 3 5 0.080 4.0 OxO VFx 24.6 90.0 st1 DEN h 3187 152 149 0.080 7.0 OxO V Fx 33.5 90.0 st1 GREATROOM c 3689 137 172 0.080 8.0 OxO VFx 14.6 70.0 GREATROOWA c 3689 137 172 0.080 8.0 Ox0 VFx 16.1 70.0 KRCFEN h 4474 213 171 0.080 7.0 Ox0 VFx 4.5 70.0 LAUNDRY C 68 2 3 0.080 4.0 Ox 0 V Fx 5A 70.0 MASTERBATH h 752 36 19 0.080 4.0 Ox0 VFx 32.9 90.0 st1 MASTERBEDROOM c 2671 107 124 0,0110 TO OxO VFx 27.9 90.0 st1 MASTERBEDROOMA c 2671 107 124 0.080 7.0 OxO VFx 35.9 90.0 st1 POWDER C 42 1 2 0.080 4.0 OxO MR 29.2 90.0 st1 SINKAREA h 718 34 13 0.080 4.0 Ox 0 V Fx 30.9 90.0 st1 STORAGE h 794 38 12 0.080 4.0 OxO VIFx 11.2 70.0 Name Trunk Type Htg (dm) Clg (dn) Design FR Veloc Npm) Diam (in) H x W (in) Dud Material Trunk st1 PeakAVF 441 437 0.080 561 12.0 0 x 0 VnlFlx Wrightsoft- 2021-J 121321:41 •.^+-� w.- -.... RigitSUL-&UN.rWI201919.021 RSU08101 Page 1 ...1wrigrt ft HVAQWYNNEBUIDLING-THECOTTAGE.np CaI.=M18 FrortDmrfa.s SW Name Grille Size (in) Htg (cim) Clg (Cfm) TEL Design (ft) FR Veloc (fpm) Diam (in) HxW (in) Stud/Joist Opening (in) Dud Mat Trunk rbl Ox0 967 967 0 I 0 0 0 Ox 0 VIFx wrig- ..htSoitL 2o21-Jan121921:a1 •W'�r w�v...,, R1911Suteg Uriverml 201919.021 RSU08101 A ...1Wrigtboft HVAQWYNNESUIDLING-THECOTTAGE. p Calc=MJ8 FmADoortaces SW Page