HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CORP. Jurisdiction:
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing New (From Plans)
10. Wall Types(1718.3 sgft.) Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent R=11 A 240.00 ft2
c. NIA R= ft2
4. Number of Bedrooms 1
d. NIA R= ft2
5. Is this a worst case? Yes
11. Ceiling Types(1336.0 sgft.) Insulation Area
6. Conditioned floor area above grade (ft2) 1306
a. Under Attic (Vented) R=30.0 1306.00 ft2
Conditioned floor area below grade (ft2) 0
b. Knee Wall (Vented) R=19.0 30.00 ft2
c. N/A R= ftz
7. Windows(128.9 sgft.) Description Area
12. Ducts, location & insulation level R ft2
a. U-Factor: Sgl, U=1.02 76.04 ft2
a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120
SHGC: SHGC=0.29
b.
b. U-Factor: Sgi, U=1.03 40.00 ft2
C.
SHGC: SHGC=0.27
13. Cooling Systems kBtu/hr Efficiency
c. U-Factor: Sgl, U=1.02 12.85 ft2
a. Central Unit 29.0 SEER:14.00
SHGC: SHGC=0.26
Area Weighted Average Overhang Depth: 4.701 ft
Area Weighted Average SHGC: 0.281
14. Heating Systems kBtu/hr Efficiency
S. Skylights Description Area
a. Electric Heat Pump 27.0 HSPF:8.20
U-Factor.(AVG) NIA N/A ft2
SHGC(AVG): N/A
9. Floor Types
Yp Insulation Area
15. Hot Water Systems
a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 ft2
a. EleciricTankless Cap: 1 gallons
b. N/A R= ft2
EF. 0.600
c. N/A R_ ft2
b. Conservation features
NoneNone
16. Credits
Glass/Floor Area: 0.099 Total Proposed Modified
Loads: 41.30
Total Baseline
Loads: 43.21 PASS
1 hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this'l!Ts(
Code.
calculation indicates compliance
with the Florida Energy Code- ri�i x
PREPARED BY:
B/Frrr�, •,, `'�'' 4
efore construction is completed
DATE.-"�®2 1
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
.
with the Florida Energy Code:
OWNER/AI�)T:
DATE: `
,
BUILDING OFFICIAL:
_.
DATE:
- Cemnliannerarlidrunr-or+if.-�f:.,..F.,fc..-----�--.
„Zlm-1..lhit inailuiaakurertnaimeair nanaierenclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSIIRESNET/ICC 380, is not greater than 0.000 On for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
6/7/2021 11:47:00 AM EnergyGaugeO USA 7.0-00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE BUIDLING-THE COTTAGE IMPACT
Address type:
Street Address
Building Type: User
Bedrooms: 1
Lot#:
-
Owner: WYNNE BUILDING CORP.
Conditioned Area: 1306
Block/SubDivision: -
TotalStories: 1
PlatBook:
-
BuilderName: WYNNE BUILDING CORP.
Worst Case: Yes
Street:
THE COTTAGE
Permit Office: ST. LUCIE COUNTY
Rotate Angle: 180
County:
St Lucie
Jurisdiction:
CrossVentilation: No
City, State, Zip:
FT. PIERCE,
Family Type: Detached
Whole House Fan: No
FL,
New/Existing: New (From Plans)
Terrain: Suburban
YearConstruct:
Shielding: Suburban
Comment:
CLIMATE
Design
Design Temp
Int Design Temp
Heating
Design
Dailytemp
Location
Tmy Site
97.5% 2.5%
Winter Summer
Degree Days
Moisture
Range
_FL, Fort Pierce
FL_VERO_BEACH_MUNICIPA 39 90
70 75
299
62
Low
BLOCKS
Number Name
Area
Volume
1 Entire House
13IM76.2001953125
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
Finished
Cooled Heated
_ 1 MASTER BEDROOM
234
1895.4 No 0
1
Yes
Yes
Yes
_2 DEN
144
1166.4 No 0
Yes
Yes
Yes
_3 SINK AREA
42
340.2 No 0
Yes
Yes
Yes
_4 CLOSET
63
510.3 No 0
No
Yes
Yes
_5 GREAT ROOM
452
3661.2 No 2
Yes
Yes
Yes
_6 MASTER BATH
50
405 No 0
Yes
Yes
Yes
_7 POWDER
25
202.5 No 0
No
Yes
Yes
_8 KITCHEN
232
1879.2 Yes 0
Yes
Yes
Yes
_9 LAUNDRY
40
324 No 0
No
Yes
Yes
_10 STORAGE
24
192 No 0
0
Yes
Yes
Yes
FLOORS
(Total Exposed Area = 1306 sq.ft.)
# Floor Type
Space
Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value
Tile Wood Carpet
_ 1 Slab -On -Grade Edge Ins
MASTER BEDROOM 31 0
234 ft 0.473
-
0.00
1.00 0.00
_ 2 Slab -On -Grade Edge Ins
DEN
24 0
144 ft 0.473
-
0.00
1.00 0.00
_3 Slab -On -Grade Edge ins
SINK AREA
7 0
42ft 0.473
-
0.00
1.00 0.00
_4 Slab -On -Grade Edge Ins
CLOSET
1 0
63ft 0.473
-
0.00
1.00 0.00
_5 Slab -On -Grade Edge Ins
GREAT ROOM
32 0
452ft OA73
-
0.00
1.00 0.00
_ 6 Slab -On -Grade Edge Ins
MASTER BATH
5 0
50 it 0.473
-
0.00
1.00 0.00
_7 Slab -On -Grade Edge Ins
POWDER
1 0
25ft 0.473
-
0.00
1.00 0.00
_8 Slab -On -Grade Edge Ins
KITCHEN
38 0
232 it 0.473
-
0.00
1.00 0.00
_ 9 Slab -On -Grade Edge Ins
LAUNDRY
1 0
40 ft 0.473
-
0.00
1.00 0.00
_10 Slab -On -Grade Edge Ins
STORAGE
21 0
24ft 0.304
-
0.00
0.00 1.00
6,71202111:47:00 AM EnergyGauge®USA 7.0.00- FlaRe52020 FBC 7th Ed ition (2020) Compliant Software Paget
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
ROOF
Roof Gable Roof
Red Solar SA Emitt Emitt
Deck Pitch
V # Type
Materials Area Area Color
,Barr Absor. Tested
Tested
Insul. (deg)
1 Hip
Metal 1376 ft' 0 IF Light
N
0.6 No
0.9 No
0 18.4
ATTIC
# Type
Ventilation Vent Ratio (I in) Area
RBS IRCC
1 Fullattic
Vented 150 1306 ft2
N
N
CEILING
(Total Exposed Area = 1336 sq.ft.)
# CeilingType
Space R-Value Ins. Type
Area
U-Factor Framing Frac.
Truss Type
_ 1 UnderAtGc(Vented)
MASTER BEDROOM 30.0 Blown
234.Oft-
0.053
0.10
Wood
_2 UnderAttic(Vented)
DEN 30.0 Blown
144.Oft-
0.053
0.10
Wood
_3 UnderAttie(Vented)
SINK AREA 30.0 Blown
42.0f 2
0.053
0.10
Wood
_4 UnderAttic(Vented)
CLOSET 30.0 Blown
63.Oft-
0.053
0.10
Wood
_5 UnderAttic(Vented)
GREAT ROOM 30.0 Blown
452.0ft-
0.053
0.10
Wood
_6 UnderAttic(Vented)
MASTER BATH 30.0 Blown
50.OIt'
0.053
0.10
Wood
_7 UndefAttie(Vented)
POWDER 30.0 Blown
25.0ft-
0.053
0.10
Wood
_8 UnderAtic(Vented)
KITCHEN 30.0 Blown
232.Oft-
0.053
0.10
Wood
_9 UnderAttic(Vented)
LAUNDRY 30.0 Blown
40.Oft-
0.053
0.10
Wood
_ 10 UnderAtfic(Vented)
STORAGE 30.0 Blown
24.0ft-
0.030
0.11
Wood
11 Knee Wall(Vented)
GREAT ROOM 19.0 Blown
30.Oft'
0.045
0.11
Wood
WALLS
(Total Exposed Area = 1718 sq.ft.)
Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the "Project" section on page 1.
VAdjacent
Cavity Width
Height
Area U-
Sheath Frm.
Solar Below
# Omt To
Wall Type
Space R-Value Ft In
Ft In
sq.ft. Factor
R-Value Frac.
Absor. Grade
1 S=>N Exterior
Cone. BIk- Int Ins
MASTER BEDROOM 4.1 18.0 0
8.0 1
145.5 0.149
0 0
0.30 0%
_2 W=>E Exterior
Conc.BIk-Intlns
MASTER BEDROOM 4.1 13.0 0
8.0 1
105.1 0.149
0 0
0.30 0%
_3 N=>S Exterior
Cone. Blk- Intlns
DEN 4.1 12.0 0
8.0 1
97.0 0.149
0 0
0.30 0%
_4 W=>E Exterior
Cone. BIk- Int Ins
DEN 4.1 12.0 0
8.0 1
97.0 0.149
0 0
0.30 0%
_5 S=>N Exterior
Cone. Bik- Intlns
SINKAREA 4.1 7.0 0
8.0 1
56.6 0.149
0 0
0.30 0%
_ 6 N=>S Exterior
Cone. Blk - Int Ins
GREAT ROOM 4.1 22.0 0
8.0 1
177.8 0.149
0 0
0.30 0%
_ 7 W=>E Exterior
Cone. BIk- Int Ins
GREAT ROOM 4.1 10.0 0
8.0 1
80.8 0.149
0 0
0.30 0%
8 S=>N Exterior
Cone. Blk - Int Ins
MASTER BATH 4.1 5.0 0
8.0 1
40.4 0.149
0 0
0.30 0%
_ 9 N=>S Exterior
Cone. BIk- Int Ins
KITCHEN 4.1 17.0 0
8.0 1
137.4 0.149
0 0
0.30 0%
_10 E=>W Exterior
Cone. Blk- Intlns
KITCHEN 4.1 16.0 0
8.0 1
129.3 0.149
0 0
0.30 0%
_ 11 S=>N Exterior
Cone. BIk- Int Ins
KITCHEN 4.1 5.0 0
8.0 1
40.4 0.149
0 0
0.30 0%
_ 12 N=>S Exterior
Cone. Bilk - Int Ins
KITCHEN 4.1 35.0 0
8.0 1
282.9 0.149
0 0
0.30 0%
_ 13 N=>S Exterior
Cone. BIk -Int Ins
STORAGE 4.1 6.0 0
8.0 0
48.0 0.149
0 0
0.30 0%
_ 14 N=>S Exterior
Cone. Blk - Int Ins
STORAGE 4.1 5.0 0
8.0 0
40.0 0.149
0 0
0.30 0%
_ 15 N=>S Garage
Frame - Wood
MASTER BEDROOM 11.0 30.0 0
8.0 0
240.0 0.092
0 0.23
0.30 0%
DOORS
(Total Exposed Area = 20 sq.ft.)
Width
Height
# Ornt Adjacent To
Door Type
Space Storms
U-Value
Ft In
Ft In
Area
1 E=>W
Insulated
KITCHEN None
0.32
3.00 0
6.00 8
20.Oft-
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
(Total Exposed Area = 129 sq.ft.)
Wall
-Overhang--
✓# Omt ID Frame
Panes
NFRC U-Factor SHGC Imp Storm Area
Depth Separation Interior Shade
Screening
-1 W=>E 2 Metal
Low-E Single
Yes 1.02
0.29 N N 32.4ft
1.0 ft 5 in 1.0 ft 5 in None
None
_ 2 W=>E 4 Metal
Low-E Single
Yes 1.02
0.29 N N 18.4ft
1.0 ft 5 in 1.0 ft 5 in None
None
_ 3 N=>S 6 Metal
Low-E Single
Yes 1.02
0.29 N N 18.4ft2
1.0 ft 5 in 1.0 ft 5 in None
None
-4 W=>E 7 Metal
Low-E Single
Yes 1.03
0.27 N N 40.Oft2
12.0 ft 0 in 1.0 ft 5 in None
None
-5 S=>N 8 Metal
Low-E Single
Yes 1.02
0.29 N N 6.9ft-
1.0 ft 5 in 1.0 ft 5 in None
None
6 E=>W 10 Metal
Low-E Single
Yes 1.02
0.26 N N 12.8ft2
1.0 ft 5 in 1.0 it 5 in None
None
INFILTRATION
# Scope Method
SLA CFM50 ELA EgLA
ACH ACH50 Space(s)
1 Wholehouse Proposed ACH(50)
0.00026
881 48.35 90.78
0.0907 5.0 All
GARAGE
# Floor Area
Roof Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
_ 1 280 ft2
280 ft2
35 ft
8 ft 11
MASS
# Mass Type
Area
Thickness FurnitureFraction Space
_ 1 Default(8lbs/sq.ft.)
0 ft2
0 ft
0.30 MASTER BEDROOM
_2 Default(Blbs/sq.ft.)
Oft•
Oft
0.30 DEN
_3 Default(8lbs/sq.ft.)
0 ft2
0 ft
0.30 SINK AREA
_4 Default(8lbs/sq.fL)
0 ft2
0 ft
0.30 CLOSET
-5 Default(8lbs/sq.ft.)
0 ft2
0 It
0.30 GREAT ROOM
6 Default(8lbs/sq.ft.)
0 ft2
0 it
0.30 MASTER BATH
_7 Default(81bs/sq.ft.)
Oft•
Oft
0.30 POWDER
-8 Default(8lbs/sq.ft.)
0 ft2
0 ft
0.30 KITCHEN
_9 Default(8lbs/sq.ft.)
Oft•
Oft
0.30 LAUNDRY
-10 Default(8lbs/sq.ft.)
0ft2
Oft
0.30 STORAGE
HEATING SYSTEM
# System Type
Subtype/Speed
AHRI# Efficiency Capacity -Geothermal HeatPump- Ducts
Block
kBtu/hr Entry Power Volt Current
-1 Electric Heat Pump
Split/Single
HSPF: 8.20 27.0 0.00 0.00 0.00 sys#1
1
COOLING SYSTEM
# System Type
Subtype/Speed
AHRI # Efficiency
Capacity Air Flow SHR Duct
Block
kBW/hr cfm
_1 Central Unit
Split/Single
SEER:14.0 29.0 0 0.80 sys#1
1
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
Subtype
Location
EF(UEF) Cap Use
SetPnt
Fixture Flow Pipe Ins.
Pipe length
1 Electric
Tankless
Garage
0.60 (0.60) 1.00 gal 61 gal
120 deg
Standard
None
82
Recirculation
Recirc
Control
Loop Branch Pump DWHR
Facilities Equal
DWHR
OtherCredits
System
Type
length length power
Connected Flow
Eff
1 No
NA NA NA No
NA
NA
NA
None
DUCTS
VDuct ----Supply-----
------Return------
Air
CFM 25 CFM 25
HVAC #
# Location
R-Value Area Location R-Value Area Leakage Type
Handler
TOT OUT
ON
RLF Heat Cool
_ 1 Attic
6.0 120 ft'
Attic
6.0 45 ft' Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans: N
Cooling []Jan
[]Feb
[j Mar
[]Apr
[]May [)]Jun [)]Jul
[XI Aug
[)]Sep []Oct
[]Nov
Dec
Heating [)] Jan
[X] Feb
[X] Mar
[ ] Apr
[ ] May [] Jun [ ] Jul
[I Aug
[ ] Sep [] Oct
[)]
Nov [X] Dec
Venting [ ] Jan
[] Feb
[X] Mar
[)] Apr
[ ] May [ ] Jun [] Jul
[ ]Aug
[ ]Sep [X] Oct
[)]
Nov [ ]Dec
VThermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3 4 5 6
7
8 9
10
11 12
Cooling(WD)
AM
PM
78
78
78
78
78 78 78 78
78 78 78 78
78
78
78 78
78
78 78
78 78
78
78 78
_Cooling(WEH)
AM
PM
78
78
78
78
78 78 78 78
78 78 78 78
78
78 78
78
78 78
78
78 78
78
78 78
_ Heating (WD)
AM
PM
68
68
68
68
68 68 68 68
68 68 68 68
68
68
68 68
68
68 68
68 68
68
68 68
_ Heating (WEH)
AM
PM
68
68
68
68
68 68 68 68
68 68 68 68
68
68
68 68
68
68
68 68
68
68
68 68
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner. WYNNE BUILDING CORP. Jurisdiction: U
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air bamershall beinstalled in the building envelope.
Air-permeableinsulationshall
requirements
The exterior thermal envelope contains a continuous airbarrier.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per
Knee walls shall be sealed.
inch minimum
Exterior thermal envelope insulation forframed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rimjoists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation,
maintain permanent contact with the underside of
above -garage
subfloordeckin ,or floor framing g cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
ofsheathing, orcontinuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawlspacewalls
Exposed earth in unvented crawl spaces shall be covered
Where provided instead of floor insulation, insulation
with a Class l vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Ductshafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrow cevifies
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garageseparation
Air sealing shall be provided between the garage and
conditionedspaces.
Recessedlighting
Recessed light fixtures installed in the building thermal
Recessed light fixtures installed in the building
envelope shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Showerttub
The air barrier installed at exterior walls adjacent to showers
Exterior walls adjacent to showers and tubs shall
on exteriorwall
and tubs shall separate them from the showers and tubs.
beinsulated.
Electrical/phonebox
The air barriershall be installed behind electrical or
on exteriorwalls
communication boxes or air -sealed boxes shall be installed.
HVAC register boot
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering
or ceiling penetrated by the boot.
Concealed
When required to be sealed, concealed fire sprinklers shall only
sprinklers
be sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
voids between fire sprinkler cover plates and walls or ceilings.
a. in addition, mspecdon of log wans snail be in accordance with the provisions of ICC-400.
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ftz)
Conditioned floor area below grade (ftz)
7. Windows" Description
a. U-Factor. Sgl, U=1.02
SHGC: SHGC=0.29
b. U-Factor. Sgl, U=1.03
SHGC: SHGC=0.27
c. U-Factor. Sgl, U=1.02
SHGC: SHGC=0.26
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
THE COTTAGE,FT. PIERCE,FL,
New (From Plans)
10.
Wall Types(1718.3 sqft.)
Insulation
Area
Detached
a. Concrete Block- Int Insul, ExteriorR=4.1
1478.30 ftz
b. Frame - Wood, Adjacent
R=11.0
240.00 ftz
1
c. N/A
R=
ftz
1
d. N/A
R=
ftz
Yes
11.
Ceiling Types(1336.0 sqft.)
Insulation
Area
a. Under Attic (Vented)
R=30.0
1306.00 ftz
1306
b. Knee Wall (Vented)
R=19.0
30.00 ftz
0
c. WA
R=
ftz
Area
12.
Ducts, location & insulation level
R ftz
76.04 ftz
a. a. Sup: Attic, Rat: Attic, AH: Attic
6 120
b.
40.00 ftz
C.
13.
Cooling Systems
kBtu/hr
Efficiency
12.85 ftz
a. Central Unit
29.0 SEERA4.00
8. Skylights Description
U-Factor.(AVG) N/A
SHGC(AVG): N/A
9. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R= 0.0
b. N/A R=
c. N/A R=
4.701 ft
0.281
14. Heating Systems
kBtu/hr Efficiency
Area
a. Electric Heat Pump
27.0 HSPF:8.20
N/A ftz
15. Hot Water Systems
Area 1306.00 ftz
a. ElectricTankless
Cap: 1 gallons
ftz
EF: 0.600
b. Conservation features
ftz
None
16. Credits
None
1 certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
&� (
Address of New Home: THE COTTAGE City/FL Zip:
a ';��Iz \ C� sa
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
® Project SummaryJob:
wrightsoftEntire House BY
QUICK CALCS, INC.
317ST. LUCIE LANE, FORTPIERCE,FL34946 Phom:772-466-6799 Email: QUICKCALCS@AOL.COM
For: WYNNE BUILDING CORP.
THE COTTAGE, FT. PIERCE, FL
Notes:
Design
Weather: Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42
OF
Outside db
OF
Inside db 70
OF
Inside db
7755
OF
Design TD 28
OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
gr/lb
Heating Summary
Sensible Cooling Equipment Load
Sizing
Structure 16327
Btuh
Structure
15522
Btuh
Ducts 4013
Central vent (0 din) 0
Btuh
Btuh
Duds
Central vent (0 cfm)
5251
0
Btuh
Btuh
none
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipment load 20340
Btuh
Use manufacturers data
n
Infiltration
Rate/swingg multipplier
Equipmerrtsensibleload
0.95
19734
Btuh
Method Simplified
Construction
Latent Cooling Equipment Load Sizing
quality
Average
Fireplaces
0
Structure
2094
Btuh
Ducts
1524
Stuh
Central vent (0 clim)
0
Btuh
Heatingg
Area(fF)
Coolinss
(none)
1306
1306
Equipment latent load
3618
Btuh
Volume (ft) 10579
10579
Airchanges/hour 0.45
EquivAVF(cfrn) 79
0.23
41
Equipment Total Load (Sen+Lat)
23352
Btuh
Req. total capacity at 0.70 SHR
2.3
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Carrier
Make Carrier
Trade CARRIER
Trade CARRIER
Model CHI4NBO3000GOA0
Cond CH14NB03000GOA0
AHRI ref 9162387
Coil FX4DNBO43L
Efficiency 8.2 HSPF
AHRI ref 9162387
Efficiency 11.5 EER,14
SEER
Heating input
Sensible cooling
20300
Btuh
Heating output 28000
Btuh @47-F
Latentcooling
8700
Btuh
Temperature rise 26
OF
Total cooling
29000
Btuh
Actual airflow 967
clm
Actual airflow
967
cfm
Air flow factor 0.048
cfm/Btuh
Airflowfador
0.047
cim/Btuh
Static pressure 0.50
in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.85
Capacity balance point = 34 OF
Backup:
Input=5 kW, Output=18005 Bluh, 100AFUE
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrFJ%Pr!J t" 2021.1arM21321.40
Rigtt-SUte®UriwrMI201919.021 RSU08101 Page 1
...\Wrigt6Dft WAC1WYNNEBUIDLING-THECOTTAGE.np Calc=MI8 Fmrt DoorPaas SW
wrighWoW Right -A) Worksheet Job'.
Entire House Date:
QUICK CALCS, INC. By
317 ST.. LUCIE LANE, FORT PIERCE, FL34946 Prow: 72466-6799 Email:QUICKCALCS@AOLCOM
1
Room name
Entire House
MASTER BEDROOM
2
EVosedwall
145A ft
31.0 ft
3
Room height
8.1 ft
8.1 ft heall000l
4
Room dimensions
13.0 x 18.0 ft
5
.Room area
1306.0 IF
234.0 W
Ty
Con5.ruction
U-value
Cr
HTM
Area
h)
Load
number,
(BWhAF--°F)
(BLIMP)
or perimeter (ft)
(B
or perimeter (ft)
(BWh)
Heat
Cool
Gross
NIPS
Heat
Cool
Grass
N/PIS
Heat
Cool
4
6
M/
13A4=
0.143
n
4.00
2.19
446
427
171C
934
0 0
0
0
�C
2glaarg,droutr.
1.040
In
29.12
21.68
18
0 537
400
0 0
0
0
Y+1
13A4o s
0.143
e
4A0
2.19
162
129
516
282
0
0
0
0
IL—
2glaang,droutr,
1.040
a
29.12
39.42
13
2
368
498
0
0
0
0
11
11DO
0.390
a
1022
10,34
20
20
223
211
0
0
0
0
N/
13A4c s
0.143
s
4.00
2.19
284
277
1107
605
w
146
584
319
I—G
2glaang,droutr,
1.040
s
29.12
21.68
7
7
202
150
0
0
0
0
13A4=
0.1431
w
4.00
2.19
284
192
767
419
105
73
291
159
1Aclom
1270I
w
35.56
34.7
41
41
1451
1419
0
0
0
0
1A-h1om
1270
w
35.56
61.76
18
3
656
1139
0
0
0
0
1A-htom
1270
w
35.56
63AO
33
5
1162
2072
33
5
1162
2072
C
16C-30m1
0.032
-
090
128
1306
1306
1170
1672
234
234
210
300
F
22A-tpl
0989
-
27.69
0.00
13N
I
145
4015
0
234
31
858
0
6
c)AEDe=mon
3591
997
Ern2lopelossigain
13885
13393
3105
3947
12
a) Infiltration
2441
668
522
143
b) Rcommanfilahm
0
0
0
0
13
Intamal gains Oompants@ 230
2
460
0
0
Appiimoesbt w
1000
0
Subtnal(lines6tr13)
16327
15522
3627
3990
LeweaL-mallcad
0
0
0
0
I
Less4ansfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtatal
16327
15522
3627
3990
151
Dudioads
25%
34%
40t3
5251
25%
34%
892
1352
Total room load
20340
2073
4518
5342
Air required(cfm)
967
967
215
249
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
20214ar 121321:40
RigttSute@ Uriwx 1201919.021 RSU08101lak Page 1
...1Wrigt%oftHUAC\WYNNESUIDLING-7HECOT AGE.nn Calc=Ml8 FrortDoorfaces:SW
F�d wrotsoft RighW@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore: 772466-6799 Email: QUICKCALCS AOL.COM
1
Roommme
DEN
SINKAREA
2
Evoredmil
24.0 It
7.0 It
3
Room height
8.1 ft he Vmol
8.1 It heaVmol
4
Room dimensans
12.0 x 12.0 It
6.0 x 7.0 It
5
Room area
144.01E
42.0 IF
Ty
Construction
U-value
Or
HTM
Area
Load
Area (fF)
Load
number
(BwhAF-'F)
(Btuh4F)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(BWh)
Heat
Cool
Gros
N/PIS
Heat
Cool
Gross
N/P/S
Heat
Cool
6
lM
13AAM
0.143
n
4.00
2.19
97
97
389
213
0
0 0
0
�G
2glaarg,droutr,.
1.040
n
29.12
21.68
0
0
0
0
0
0 0
0
13A4ocs
0.143
a
4.00
2.19
0
0
0 0
0
0 0
0
f-G
2glaang,drour,
1.040I
a
29.12
39.42
0
0
0 0
0 0
0
0
11
I-D
11DO
0.390
a
10.92
10.34
0 0
0 0
0
0
0
0
W
13AAc s
0.143
s
4.00
2.19
0 0
0 0
57
67
227
124
�G
2glaang,droutr,
1A40
s
29.12
21.68
0 0
0 0
0
0
0
0
13AAo s
0.143
w
4.00
2.19
97
79
315
172
0
0
0
0
1Aclom
1270
w
35.56
34.77
0
0
0
0
0
0
0
0
to-hlom
1270
w
35.56
61.76
18
3
656
1139
0
0
0
0
1A-hlom
1270
w
3556
63.40
0
0
0
0
0
0
0
0
C
1613.901"11
0.032
-
0.90
128
144
144
129
184
42
42
38
54
F
22AAPI
0.989
-
27.69
0.00
144
I
24
665
0
42
7
194
0
6
c)Amexgmion
574
3
Enoalopelossyain
2154
2283
459
175
12
a) Infiltration
404
111
118
32
b) Roomeentilafion
0
0
0
0
13
Internal gains: Ocwpants@ 230
0
0
p
0
Appliancesrolher
0
0
Subtotal (lines6h113)
2558
2394
576
207
Lessextemalload
0
0
0
0
Lewranser
0
0
0
0
Redisinbuton
0
0
0
0
14
Subtotal
2558
2394
5
207
15
Dudloads
25%
34%
629
811
25%
345/6
14242
70
Tot31 room load
3187
3205
1
718
278
Air required (dm)
152
149
34
13
• Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
•r wr4ghrsofe- RigrtSUte®Ud201919.021 RSU081
-.\Wdgt6oft HVApWYNNE BUIDLING-THE COTTAGE.AGE.np Calc=M18 Frort Do 2021-Jan-121321:40
fa or®s SW Page 2
wrlghtsoft• Right-J® Worksheet Deb:
Entire House Date:
QUICK CALCS, INC. By,
317ST. LUCIEL.4NE,FORr PIERCE. FL34946 Pnre:772466-6799 Email: QUICKCALCS@AOL.COM
1
21
Room name
Expoaadwall
CLOSET
GREAT ROOM
0 ft
32A ft
3
Room hei hf
9
8.1 ft heat/mol
8.1 ft heaV000l
4
Room dimensons
9.0 x 7.0 R
1.0 x 452A ft
5
Room area
63.0 IF
452.0 IF
Ty
Construr9on
U-value
Or
HTM
Area (ff)
Lead
Load
number
(BWhr--°F)
(BWW
or perimeter (ft)
(BWh)
or perimeter (ft)
(BWh)
Heat
Cool
Grose
NIPS
Heat
Cool
Gros
N/P/5
Heat
Cool
6
Y�C
13AAos
0.143
n
4.00
2.19�
0
0
0
0 178
160
640
350
2glaarg,droutr,
13A4=
1.040
0.143
n
a
29.12
4.00
21.68
2.191
0
0
0
0
0
0
0 18
0
0 537
400
2glaagg,droutr,
1D40
a
29.12
39.42�
0
0
0
0
0
0
0 0
0 0
0
11
1100
0.390
a
1092
10,34
0
0
0 0
0
0 0
0
0
13A
G
2glaang,droutr,
1.040
s
29.12
21.68
0 0
0 0
0 0
0
0
13AAocs
0.143
w
4.00
2.19
0 0
0 0
81
40
161
88
1Aotom
1270
w
35.561
34.77
0 0
0 0
41
41
1451
1419
1A-h1om
1270
w
35S6I
61.76
0 0
0
0
0 0
0
0
1A.htom
1270
w
3556
63.40
0
0
0
0
0
0
0
0
C
16C30m1
0.032
-
0.90
128
63
63
56
81
452
452
405
579
F
I22A-tpl
0.989
-
27.69
0.00
63
0
0
0
452
32
886
0
6
c)AED exalrson
-1
2069
Envelope los9gain
56
80
4080
4903
12
a) Infiltration
0
530
148
b) Roomventilabon
0
0
0
13
Internal gains: O=pants@ 230
0
0
2
Appliance.4ot
q60
0
0
SubbbI(lines6to13)
T14
80
4619
5511
Lesexamal load
0
0
0
Lestransler
0
0
0
RedistribiAon
0
0
0
14
Subbtl
80
4619
5511
15
Dudloads
25%
34%27
25%
34%
1135
18W
Total room load
Airrequired(dm)
70
107
5754
7379
3
5
274
343
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
- wr�ghisoR- `t ... Rig Ar 919.02101 2021J121321:40
\WngttoftHVACWYNNEBUIDLIN-THFCOTTGE.rLp CaIc=MI8 FmnDoorfarxsSW Page 3
r}r wrightsofr Right- J@ Worksheet Jcb:
Entire House Dy.
By.
QUICK CALCS, INC.
317 ST. LUCE LANE, FORT PIERCE, FL34946 Ptore:772-0666799 Emil: QUICKCJLLCS@AOL.00M
1
Room name
MASTER BATH
POWDER
2
Erpcmdwall
5D ft
0 ft
3
Room height
&1 It heallmol
8.1 It IxaNmol
4
5
Roan dim vao
Rpomarea
Ion x 5,0 It
5oD IF
5,0 x 5D ft
25.0 fF
TY
Construction
U-Value
or
HTM
Area (fly
Load
rea
A(ff)
Load
numbs
(BWhAF-'q
(BWW
a pen star (t)
@Wh)
or perimeter (ft)
(BWh)
Heat
Cool
Gros
NIPS
Heat
Cool
Gross
NIPS
Heat
Cool
6
WL
13A-4=
2ghong,droutr,
13A ccs
0.143
1D40
0.143
n
n
a
4.00
29.12
4D0
2.19
21.68
2.19
0
0
0
0
0
0
0
0
0
0
0
0
0
- 0
0
0
0
0
0
0
0-
0
0
0
11
IG
D
2gWaW ng,dra,
11130
1D40
0390
a
a
29.12
10.92
39.42
1034
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
13A-4as
2glaarg,dreutr,
0.143
1D40
s
a
4D0
29.12
219
21.68
41
7
34
7
134
202
73
150
0
0
0
0
0
0
0
0
L—
4y
13A4as
w
4D0
0
0
0
0
0
0
0
0
1A-hI=
1Ah1om
1270
1270
1270
w
w
3556
3556
4.77
81.76
61.76
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
IA-hlom
12M
w
3556
63.40
0
0
0
0
0
0
0
0
C - -
16C-3Dml
0.=
-
090
128
50
50
45
64
25
25
- 22
32
F
22W
o.W
-
27D9
ODO
I
50
i
5
138
0
25
0
0
0
6
c)AED e=rsa
1
4
1
1
0
Envelope los (gain
520
284
22
32
12
a) Match
84
23
0
0
b) Rcomuenfilation
0
0
0
0
13
Intarrlal gains Occupants@ 230
0
0
0
0
Applian esiother
0
0
SubtAW(lines61D13)
604
307
22
32
Less odernal load
0
0
0
0
Lestrarder
Redi<Libulion
0
0
0
0
0
0
0
0
14
SubWmk
604
307
22
32
15
Ductlows,
25%
34%
148
104
25%
34%
6
11
Total room icad
Air required (din)
752
36
411
19
-
28
1
42
2
Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed
■'Id- w Oftcwit- 2021-Jar-121321:40
Aft,.Ri9t6SdteOUriVersa1201919.021 RSU08101 Page
-.\Wrigtlsoft HVAC\WYNNEBUIDLINC-TECOTrAGE.np Calc=MI8 Fmrt DUorracaa SW
t1 wrightsofi° Right-® Worksheet Job;
Entire House By.
By.
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34M Phore: T72-466-6799 Email: QUICKCALCS@AOL.COM
1
Roommme
KTCHEN
LAUNDRY
2
E)posdwall
38.0 ft
0 ft
3
Room height
8.1 ft heWl=l
8.1 ft heaVoxl
4
Room dimensions
1.0 x 232.0 ft
4.0 x 10.0 ft
5
Room area
232.0 ft2
40.0 T
Ty
Construction
U-lalue
Or
HTM
Area OF)
Load
Area (W)
Load
number
(BWhd2-°F)
(BWhil6)
or perimeter (ft)
(BNh)
or pedmeter (ft)
(Bluh)
Heat
Cool
Gros
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
V"13A-4ps
0.143
n
4.00
2.19
138
138
551
3D1
0
0
0
0
2glaang,droutr,
1.040
n
29.12
21.68
0
0
0
0
0
0
0
0
13A-4os
0.143
a
4.00
2.19
130
97
387
211
0
0
0
0
2glaang,droutr,
1.040
a
29.12
39.42
13
2
368
498
0
0
0
0
11
D
11D0
0.390
a
10.92
10.34
20
20
223
211
0
0
0
0
t-G
la44=
0.143
s
4.00
2.19
41
41
162
89
0
0
0
0
2glaarg,droutr,
13A4o s
1Aclom
1.040
0.143
1270�
s
w
w
29.12
4.00
3556
21.68
2.19
34.77
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
�C
I`-CG
1A-hlom
1270
w
35.56
61.76
0
0
0
0
0
0
0
0
IA-hlom
1270
w
35.56
63.40
0
0
0
0
0
0
0
0
C
16C-30ml
0.032
0.90
128
232
232
208
297
40
40
36
51
F
E
22A-tpl
0.989
-
27,69
0.00
232
38
1052
0
40
0
0
0
6
c)AED e=ram
-37
-1
Enuelope los4gain
2951
1570
1
36
51
12
a) Infiltration
640
175
0
0
b) Roomeentila4on
0
0
0
0
13
Internal gairs: O=pants@ 230
0
0
0
0
Appliances(other
1000
0
Subb&(lines6to13)
3591
2745
36
51
Lese)temalload
0
0
0
0
LestrarLfer
0
0
0
0
Redistribubm
0
0
0
0
14
Subtotal
3591
2745
36
51
15
Dudloads
25%
34%
883
931
25%1
340/6
9
17
Total room load
Air reguired(cim)
1
4474
213
3676
171
45
2
68
3
Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed
2021-Jart121321:40
RigftSute9Uriv rsa1201919.021 RSU08101
A&A ...\,dgttoRWAaWY NEBUIDLING-THECOTTAGE. Calc=tJJB FrortDoorfa.SW Page
wrightsoft° RighWO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By,
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore: 772466-6799 Email: QUICKCALCS ,AOL.COM
1
Room name
STORAGE
2
EVosedwall
8.0 ft
3
Room height
8.1 ft heayocol
4
Room dimensore
4.0 z 6.0 ft
5
Room area
24.0 T
Ty
Construction
U-value
Or
HTM
Area (fF)
Load
Area
Load
number
(BWh/ft--g
(BluW)
or perimeter (1)
(BGrh)
or perimeter
Heat
I Cool
G.
NWP/S
Heat
Cool
G.
N/P/S
Heat
Cool
6
VIl
13A-4ocs
0.143
n
4.00
2.19
32
32
130
71
�G
2glaarg,droutr,
1.040
n
29.12
21,68
0
0
0
0
13A-0as
0.143
a
4.00
2.19
32
32
130
71
2glaang,droutr,
1.040
a
29.12
39.42
0
0
0
0
11
11DO
0.390
a
10.92
10.34
0
0
0
0
W
13A-0as
0.143
s
4.00
2.19
0
0
0
0
t-G
2glazig, droutr,
1.040
s
29.12
21.68
0
0
0
0
13A4ors
0.143
w
4.00
2.19
0
0
0
0
1Aclom
1270
w
3556
34.77
0
0
0
0
1A-hlom
1270
w
3556
61.76
0
0
0
0
1A-h1om
1270
w
35.56
63.40
0
0
0
0
C
16030ml
0.032
-
0.90
128
24
24
22
31
F
I
22A-tpl
0989
-
27.69
0.00
24
8
222
0
6
c) AED e=rscn
.3
Envelope loss/gain
502
170
12
a) Infiltali
135
37
b) Roomventlaton
0
0
13
Intemalgairs: Oompanls@ 230
0
0
Appliano=_shmer
0
SubMal(lines6to13)
637
207
LesseAemalload
0
0
Lesstranster
0
0
Redistributon
0
0
14
Sublotsl
637
207
15
Ductloads
25%
29%
157
60
Total room load
794
266
Air required (cfin)
38
12
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
2021-Jan-121321:40
RigrtTHE CJ T-rAGE.np 919.02t R FortD1 Page6
...\WrigFEoftHVACIWYNNE BUIOLING-THE COTiAGE.np CaIc=MIB FrortDoorfao;s:SW
Duct System Summary Date:
wrightsoft SDate:
Entire House By.
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34M Ph w772466-6799 Em il:QUICKCALCS@AOL.COM
Project Information
For. WYNNE BUILDING CORP.
THE COTTAGE, FT. PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply/return available pressure
Lowest fdcUon rate
Actual airflow
Total efective length (TEL)
Heating
0.50
in H2O
028
in H2O
0.22
in H2O
0.110/0.110
in H2O
0.080
in/100ft
967
cftn
126
Supply Branch Detail Table
Cooling
0.50
in H2O
028
in H2O
0.22
in H2O
0.110/0.110
in H2O
0.080
in/100ft
967
cfm
Name
Design
(Btuh)
Htg
(CIM)
Clg
(Cfm)
Design
FR
Diam
(in)
H x W
(in)
Dud
mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
CLOSET
C 107
3
5
0.080
4.0
OxO
VFx
24.6
90.0
st1
DEN
h 3187
152
149
0.080
7.0
OxO
V Fx
33.5
90.0
st1
GREATROOM
c 3689
137
172
0.080
8.0
OxO
VFx
14.6
70.0
GREATROOWA
c 3689
137
172
0.080
8.0
Ox0
VFx
16.1
70.0
KRCFEN
h 4474
213
171
0.080
7.0
Ox0
VFx
4.5
70.0
LAUNDRY
C 68
2
3
0.080
4.0
Ox 0
V Fx
5A
70.0
MASTERBATH
h 752
36
19
0.080
4.0
Ox0
VFx
32.9
90.0
st1
MASTERBEDROOM
c 2671
107
124
0,0110
TO
OxO
VFx
27.9
90.0
st1
MASTERBEDROOMA
c 2671
107
124
0.080
7.0
OxO
VFx
35.9
90.0
st1
POWDER
C 42
1
2
0.080
4.0
OxO
MR
29.2
90.0
st1
SINKAREA
h 718
34
13
0.080
4.0
Ox 0
V Fx
30.9
90.0
st1
STORAGE
h 794
38
12
0.080
4.0
OxO
VIFx
11.2
70.0
Name
Trunk
Type
Htg
(dm)
Clg
(dn)
Design
FR
Veloc
Npm)
Diam
(in)
H x W
(in)
Dud
Material
Trunk
st1
PeakAVF
441
437
0.080
561
12.0
0 x 0
VnlFlx
Wrightsoft- 2021-J 121321:41
•.^+-� w.- -.... RigitSUL-&UN.rWI201919.021 RSU08101 Page 1
...1wrigrt ft HVAQWYNNEBUIDLING-THECOTTAGE.np CaI.=M18 FrortDmrfa.s SW
Name
Grille
Size (in)
Htg
(cim)
Clg
(Cfm)
TEL Design
(ft) FR
Veloc
(fpm)
Diam
(in)
HxW
(in)
Stud/Joist
Opening (in)
Dud
Mat
Trunk
rbl
Ox0
967
967
0 I 0
0
0
Ox 0
VIFx
wrig- ..htSoitL 2o21-Jan121921:a1
•W'�r w�v...,, R1911Suteg Uriverml 201919.021 RSU08101 A
...1Wrigtboft HVAQWYNNESUIDLING-THECOTTAGE. p Calc=MJ8 FmADoortaces SW Page