HomeMy WebLinkAboutRevisions j NI`
- i
OFFICE USE ONLY:
DATE FILED: ' PERMIT# Ind
REVISION FEE: I S •®� RECEIPT#
PLANNING & DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772)462-1553 RECEIVED
APPLICATION FOR BUILDING PERMIT REVISIONS NOV 3 0 M1
PROJECT INFORMATION
St.Lucie County
Permitting
LOCATION/SITE
ADDRESS:
5358 San Benedetto Place (124/5)
DETAILED DESCRIPTION OF PROJECT I-ILE COPY
REVISIONS:
Due to equipment shortages,the air handler being installed with have a different serial#than was originally called for.
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CRC1330146 ST. LUCIE CO CERT. #:
BUSINESS NAME: Adams Homes of Northwest Florida,INC
QUALIFIERS NAME: William Bryan Adams
ADDRESS: 3000 Gulf Breeze Parkway
CITY: Gulf Breeze STATE: Fl- ZIP: 32563
PHONE (DAYTIME): 772-905-8394 FAX:
OWNERMUILDER INFORMATION:
NAME: Adams Homes of Northwest Florida,Inc
ADDRESS:3000 Gulf Breeze Parkway
CITY: Gulf Breeze STATE: FL ZIP: 32563
PHONE (DAYTIME: 772-905-8394 FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME: Keesee Associates
ADDRESS: 945 South Orange Blossom Trail
CITY: Apopka STATE: FL ZIP: 32703
PHONE(DAYTIME): 407-880-2333 FAX: ryryry
y r
`T''� -.
SLCCC: 9123109 F'
Revised 06130117
4
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 124 Blocks Wat e 1 0 AGL Builder Name: ADAMS HOMES
Street: 5358 San Benedett la City,State,Zip: Fort Pierce,FL;34 19ty
r:
Owner: Ne,
Design Location: FL,STLUCIECOINTL (Florida Climate Zone 2)
1. New construction or existing New(From Plans) 10. Wall Type$2120.0 sqft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1780.00 f 2
b.Frame-Wood,Adjacent R=13.0 270.00 ftZ
3. Number of units,if multiple family 1 c. Frame-Wood,Exterior . R=13.0 70.00 ftZ
4. Number of Bedrooms 4 d.N/A R= ftZ
11.Ceiling Types (1900.0 sqft.) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0, 1820.00 ftZ
6. Conditioned floor area above grade(ftZ) 1820 b.Knee Wall(Vented) R=19.0 80.00 ftZ
Conditioned floor area below grade(ftZ) 0 c. N/A R= ftZ
7. Windows(239.3 sqft.) Description Area 12.Ducts R ftZ
a. U-Factor: Dbl,U=0.33 168.74 ftZ a.Sup:Attic, Ret:Main,AH:Main 6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl,U=0.33 32.38 ftZ 13.Cooling syste kBtu/hr Efficiency
SHGC: SHGC=0.21 a.Central Unit'�� ®P"5.0 SEER:15.50
c. U-Factor: Dbl,U=0.33 20.42 ftZ 0
SHGC: SHGC=0.31 14.Heating systems kBtulhr Efficiency
Area Weighted Average Overhang Depth: 4.143 ft.
Area Weighted Average SHGC: 0.269 a.Electric Heat Pump 34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ftZ 15.Hot water systems
SHGC(AVG): N/A a.Electric Cap:40 gallons
9. Floor Types (1820.0 sqft.) Insulation Area EF:0.940
a.Slab-On-Grade Edge Insulation R=0.0 1820.00 ftZ b. Conservation features
b. N/A R= ftZ None
c.N/A R= ftZ 16.Credits Pstat
Glass/Floor Area: 0.131
Total Proposed Modified Loads: 64.33 PASS
_ Total_Baseline Loads: 64.79
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are i ompliance with the lorida Energy specifications covered by this ¢p
Code. calculation indicates compliance cgri,(�''
with the Florida Energy Code:
PREPARED BY: Before construction is completed
DATE' 11-30-20?1 C orrina Mahey this building will be inspected for
compliance with Section 553.908
I herebycertify that this building,as designed, is in compliance Florida Statutes.
fY 9� 9 P '��- �y� -,•
with the Florida Enprnilir Code.
OWNER/AGENT. BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as..
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
11/30/2021 11:28 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 4
FORM`R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Lot 124 Block5 Waterstone 1 Bedroom's: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1820 Lot# 124
Owner Name: Total Stories: 1 Block/Subdivision: Waterstone
#of Units: 1 Worst Case: No PlatBook:
Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5358 San Benedetto PI
Permit Office: Cross Ventilation: No County: St. Lucie
Jurisdiction: 661000 Whole House Fan: No City,State,Zip: Fort Pierce,
Family Type: Detached FL, 34951
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days .Moisture Range
FL,ST_LUCIE_CO_INTL FL_VERO_BEACH MUNI 39 90 70 75 299 58 Medium
BLOCKS
Number . Name Area Volume
1 Blockl 1820 18200
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value .Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 33 ft 0 1820 ftz _--- 0.42 0 0.58
ROOF
/ Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
V -- # Type Materials Area Area Color - Barr Absor. Tested Tested Insul. (deg)
1 Gable.or.Shed Composition shingles 2035 ftZ 456 ft' Medium N 0.85 N 0.85 No 0 26.57
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1820 ft2 N N
CEILING -
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1820 ftZ 0.11 Wood
2 Knee Wall(Vented) Main 19 Batt 80 ftz 0.11 Wood
11/30/2021 11:28 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 NE Exterior Concrete Block-Int Insul Main 4.1 59 0 10 0 590.0 ftZ 0 0 0.6 0
2 NW Exterior Concrete Block-Int Insul Main 4.1 13 0 10 0 130.0 ftz 0 0 0.6' 0
3 SW Exterior Concrete Block-Int Insul Main 4.1 66 0 10 0 660.0 ftZ 0 0 0.6 0
4 SE Exterior Concrete Block-Int Insul Main 4.1 40 0 10 0 400.0 ftZ 0 0.6 0
5 Garage Frame-Wood Main 13 27 0 10 0 270.0 ftZ 0 0.23 0.01 0
6 NW Exterior Frame-Wood Main 13 7 10 70.0 ftZ 0.23 0.6 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 NW Insulated Main None .25 3 6 8 20 ftZ
2 - Wood Main None .25 2 8 6 8 17.8 ftZ
WINDOWS
Orientation shown is the entered,Proposed orientation..
Wall Overhang
# Ornf ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade' Screening
1 NE 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ftZ 1 ft 4 in 0 ft 10 in None None
2 NE 1 Vinyl Low-E Double Yes 0.33. 0.23 N 48.6 ft' 1 ft 4 in 0 ft 10 in. None None
3 NW 6 Vinyl Low-E Double Yes 0.33 0.31 N 7.1 ft' 9 ft 0 in 0 ft 6 in None None
4 NW 2 Vinyl Low-E'Double Yes 0.33 0.21 N 16.2 ft' 1 ft 0 in 0 ft 10 in None None
5 NW 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft' 1-ft 0 in 0 ft 10 in None None
6 NW 6 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft' 9 ft 0 in 2 ft 0 in None None
7 SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ftZ 1 ft 4 in 0 ft 10 in None None
8 SE 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ftZ 11 ft 10 in-0 ft 6 in None None
9 SE 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ftZ 1 ft 4 in 0 ft 10 in None None
10 SE 4 Vinyl .Low-E Double Yes 0.33 0.23 N 32.4 ft' 11 ft 10 in 0 ft 6 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter- Avg.Wall Height Exposed Wall Insulation
1 396 ftZ 396 ftZ 64 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1. Wholehouse Proposed ACH(50) .000444 2123.3 116.49 218.7 .1381 7
11/30/2021 11:28 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 4
FORM R405-2020 . INPUT SUMMARY CHECKLIST REPORT.
HEATING SYSTEM
# System Type Subtype Speed Efficiency _ Capacity Block Ducts
1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1. sys#1
COOLING SYSTEM
# System Type Subtype Subtype . Efficiency. Capacity _ Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER: 15.5 35 kBtu/hr cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
/ ----Supply---- ----Return--- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 364 ftZ Main 91 ftz Default Leakage Main (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan HF eb Mar A r I IM
a rl Jun ri
Jul [X]Au rl
Se Oct Nov Dec
Heatin f X Jan Feb X Mar APr May Jun Jul [ ]AuSeP 1XI
Oct Nov �X�Dec
Ventin [ Jan Feb X Mar [X]Apr May Jun Jul [ ]Aug Se Oct H
Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78- 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 - 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.. 0 ftZ 0 ft 0.3 Main
11/30/2021 11:28 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 4
ti
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index,the more efficient the home.
5358 San Benedetto Place, Fort Pierce, FL, 34951
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1780.00 ftZ
b.Frame-Wood,Adjacent R=13.0 270.00 ftZ
3. Number of units,if multiple family 1 c. Frame-Wood, Exterior R=13.0 70.00 ftz
4. Number of Bedrooms 4 d.N/A R= ftZ
5. Is this a worst case? No 11.Ceiling Type and insulation level Insulation Area
a.Under Attic(Vented) R=30.0 1820.00 ftZ
6. Conditioned floor area(ftZ) 1820 b.Knee Wall(Vented) R=19.0 80.00 ftZ
7. Windows- Description Area c. N/A R= ftZ
a. U-Factor: Dbl,U=0.33 168.74 ftZ 12.Ducts,location&insulation level R ftZ
a.Sup:Attic, Ret:Main,AH: Main 6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl,U=0.33 32.38 ftZ
SHGC: SHGC=0.21 13.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.33 20.42 ftZ a.Central Unit 35.0 SEER:15.50
SHGC: SHGC=0.31
d. U-Factor: other(see details) 17.78 ftZ 14.Heating systems kBtu/hr Efficiency
SHGC: other(see details) a.Electric Heat Pump 34.6 HSPF:8.50
Area Weighted Average Overhang Depth: 4.143 ft.
Area Weighted Average SHGC: 0.269
8. Skylights Description Area 15.Hot water systems
Z a. Electric Cap:40 gallons
a. U-Factor(AVG): N/A ft EF:0.94
SHGC(AVG): N/A b. Conservation features
9. Floor Types Insulation Area None
a.Slab-On-Grade Edge Insulation R=0.0 1820.00 ftZ Credits(Performance method) Pstat
b.N/A R= ftZ
c.N/A R= ftZ
I certify that this home has complied with the Florida Energy Efficiency Code for BuildinggE sr
Construction through the above energy saving features which will be installed (or exceeded) y0 a? O
in this home before final inspection. Otherwise, a new EPL Display Card will be completed 4i' .''%' •='s.. "{'
based on installed Code compliant features. nlrl<: w<,,'`
Builder Signature. ( Date:
Address of New Home: City/FL Zip:
coD �
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
11/30/2021 11:28 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
FORM R405-2020
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2020 Florida Building Code,Energy Conservation via the
Residential Simulated Performance.Alternative shall include:
❑ This checklist
❑ Form R405-2020 report
❑ Input summary checklist that can be used for field verification (usually four pages/may be greater)
❑ Energy Performance Level(EPL)Display Card(one page)
❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
❑ Mandatory Requirements(five.pages)
Required prior to CO:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -one page)
❑ A completed 2020 Envelope Leakage Test Report(usually one page);exception in R402.4
allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to
comply with Section C402.5 -
❑ If Form R405 duct leakage type indicates anything other than "default leakage'; then a completed
2020 Duct Leakage Test Report-Performance Method(usually one page)
11/30/2021 11:28:02 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation; 7th Edition (2020)
Mandatory Requirements for Residential.Performance, Prescriptive and ERI Methods
ADDRESS: 5358 San Benedetto Place Permit Number:
Fort Pierce,FL,34951
MANDATORY REQUIREMENTS -See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level(EPL)display card(Mandatory)The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
❑ (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed'by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD.
SECTION R402 BUILDING THERMAL ENVELOPE
❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
❑ R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and
R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required
by the code official,an approved third party shall inspect all components and verify compliance.
❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8."Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either
individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or
an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions,alterations, renovations,or repairs,of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures.
2.Dampers including exhaust,intake, makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures.
3. Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems,if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where
❑ using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the
fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
❑ R402.4.3 Fenestration air leakage. Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when"tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
11/30/2021 11:28 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion.air to
open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall-R-value requirement.The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential.
❑R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls..
R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental.heat operation when the heat pump compressor can meet the heating load.
R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or
(7),-Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g)or(i),Florida Statutes,to be"substantially leak free"in
accordance with Section R403.3.3.
R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,
including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise
sealed during the test.
2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire
system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located-entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.Duct leakage testing is required for Section
R405 compliance where credit is taken for leakage,and a duct air leakage Qn to the outside of less than 0.080(where Qn=
duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals)is indicated in the
compliance report for the proposed design.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause
degradation of the material.Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). If heated water circulation systems are
installed,they shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with
Section R403.5.1.2.Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall
❑ be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.Controls for
circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The
controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no
demand for hot water.
R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall
automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the
times when heated water is used in the occupancy.
11/30/2021 11:28 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'Y2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies(Mandatory).
❑ R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature
setting range shall be from 100°F to 140°F(38°C to 60°C).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)of
combustion types of service water-heating systems to be turned off.
R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar
water-heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation
including:Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical
ventilation,the air handler shall be powered by an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable
Indoor Air Quality,shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3.. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10
otherwise.
R403.7 Heating and cooling equipment.
El on
Equipment sizing(Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based
on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation
methodologies,based on building loads for the directional orientation of the building.The manufacturer and model number of the
outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design
conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other
factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical
ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have
an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is
installed.
TABLE R403.6.1
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMU
(CFM) (CFM/WATT) (CFM)
HRV or ERV Any 1.2 cfm/watt Any
Range hoods Any 2.8 cfm/watt Any
In-line fan Any 2.8 cfm/watt Any
Bathroom,utility room 10 1.4 cfm/watt <90
Bathroom,utility room 90 2.8 cfm/watt Any
For SI:1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916
11/30/2021 11:28 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS- (Continued)
❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected,in
Section R403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the'calculated latent load.
The published value for AHRI total capacity is a nominal,rating-test value and shall not.be used for equipment sizing.Manufacturer's
expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bu.lb
temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded
performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Florida Building Code,Energy Conservation—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C).
❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an
integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation
of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the
power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
11/30/2021 11:28 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 5
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered
energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required.
❑ R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and,spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas(Mandatory).The energy consumption of electric-powered portable spas shall be controlled by the
requirements of APSP-14.
R403.13 Dehumidifiers(Mandatory If installed,a dehumidifier shall conform to the following requirements:
1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/kWh if the total dehumidifier capacity for the house
is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day.
2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air..
3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2.
4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code,Residential.
R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13,
conform to the following requirements:
1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system,a backdraft
damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct.
2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system,
a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct.
3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the.return duct side upstream from the .
central cooling evaporator coil
4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment(Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an
efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt.
R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall-not have continuously burning-pilot lights.
11/30/2021 11:28 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 5 of 5
2020-AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a
Project Name: Lot 124 Block5 Water-stone 1820 AGL Builder Name: ADAMS HOMES
Street: 5358 San Benedetto Place Permit Office:
City,State,Zip: Fort Pierce',FL,34951 Permit Number: Y
Owner: Jurisdiction: 661000 w
Design Location: FL,ST_LUCIE_CO_INTL U
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope.- Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/door jambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls.
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac 3s.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall.
on exterior wall tubs-shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exteriorwalls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor,wall covering or
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended'by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire ALOnkler cover plates and walls or cewlin 5
a.In addition,inspection of log walls shall be in accordance with the provisions of]CC-400. -
11/30/2021 11:28 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower. Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, "Energy Conservation, 7th Edition
Jurisdiction: 661000 Permit#:
J-6 Information
Builder- ADAMS HOMES Community: Lot: NA
Address: 5358 San Benedetto Place
City: Fort Pierce State: FL Zip: 34951
,Air Leakage,Test eResults Passing;results,must meet either•the Performance, Prescriptive,or ER!Method
,'0 :PRESCRIPTIVE METHOD Tt a bwlding or dwelling unit shall be'tested;and"venfled,as havrr g an air leakage;r`ate of not exceeding 7 air `,
changes per:hour at•a pressure of,0.2 inch w.g:'(50 Pascals)in-Climate Zones'1 and 2 "
PERFORMANCE or-ER'I METHOD-The building`or dwelling unit shall,be tested'and;yerrfied�as having an air leakage rate of hot exceedi'
the.selected ACH(50)value;as shown on Form R405=2020,(Performance)or R406-2020,(E'RI);section labeled,as;infiltration;sub section ACH50
ACH(50).specifie'on Form R405-2020-Energy Calc.(P,erfomiance)or R406-2020(ERQ 7.000
x 60 _ 18200 — Method for calculating building volume:
CFM(50) Building Volume ACH(50)
Q Retrieved from architectural plans
F-1 PASS 0 Code software calculated
El When ACH(50) is less than 3, Mechanical Ventilation installation Q Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f),(g),or(1)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode.official,Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration
control measures.
2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control
measures.
3.Interior doors,if installed at the time of the test,shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5:Heating and cooling systems,if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
Testing'Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification#: Issuing Authority:
11/30/2021 11:28:21 AM EnergyGauge@ USA 7.0.00-FlaRes2020 FBC.7th Edition(2020)Compliant Software Page 1 of 1
Manual S Compliance Report Job: Lot 124 Block 5 Waterston...
DEL--AIR Date:
NMMV.•=CONOR UMC Entire,House By. DCS
DEL AIR HTG,A/C& REFRIG. INC
531 CODISCO WAY,SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM
Project • •
For: ADAMS HOMES
5358 San Benedetto Place,Fort Pierce,FL 34951
Cooling Equipment
Design Conditions
Outdoor design DB: 90.4°F Sensible gain: 24849 Btuh Entering coil DB: 76.4°F
Outdoor design WB: 77.4OF Latentgain: 4767 Btuh Entering coil WB: 63.2°F
Indoor design DB: 75.0 OF Total gain: 29616 Btuh
Indoor RH: 50% Estimated airflow: 1167 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SpIitASHP
Manufacturer: Carrier Model: 25HBC537AP030+FX4DNF043L
Actual airflow: 1167 cfm
Sensible capacity: 28188 Btuh 113%of load
Latent capacity: 5115 Btuh 107%of load
Total capacity: 33303 Btuh 112%of load SHR: 85%
Heating Equipment
Design.Conditions
Outdoor design DB: 41.0OF Heat loss: 28493 Btuh Entering coil DB: 69.5OF
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SpIitASHP
Manufacturer: Carrier Model: 25HBC537AP030+FX4DNF043L
Actual airflow: 1167 cfm
Output capacity: 31708 Btuh 111%of load Capacity balance: 36 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1167 cfm
Output capacity: 7.6 kW 91%of load Temp.rise: 20 OF
Meets all requirements ofACCA Manual S.
-P- wrightsoft® 2021-Nov-3011:26:14
>�• -��m M Rigft-Sute®Uriversal 2021 21.0.07 RSU24004 Page 1
820AGLLot124Blk5Waterstore1820AGL_FX43AILrnp Calc=MJ8 Frort Door faces:NW
Component Constructions p : Lot 124 Block 5 Waterston
DEL-AIR ...
HEMS•Ale CONDMONNG Entire House. By: DCS
DEL AIR HTG,A/C& REFRIG.INC
531CODISCO WAY SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW:DELAIR.COM
Project • •
For: ADAMS HOMES
5358 San Benedetto Place,Fort Pierce,FL 34951
Design Conditions
Location: Indoor: Heating Cooling
St Lucie Co Intl,FL,US _ Indoor temperature(°F) 70 75
Elevation: 26 ft Design TD(OF) 29 15
Latitude: 28 ON Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr1lb) 2.4 56.9.
Dry bulb(OF) 41 90 Infiltration:
.Daily range(OF) - 15 ( L ) Method Simplified
Wet bulb(OF) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Construction descriptions , Or Area U-value Insul"R Htg HTM Loss Clg HTM Gain
ft� Btuh/ftzF ftzcF/Btuh BUM Btuh BtuWt� Btuh
Walls
16B-19ad:Knee wall,asphalt shingles roof mat,09 kw ins,1/2"gypsum ne 20 0.049 19.0 1.42 28 2.59 52
board int fnsh se 20 0.049 19.0 1.42 28 2.59 52
sw 20 0.049 19.0 1.42 28 2.59 52
nw 20 0.049 19.0 1.42 28 2.59 52
all 80 0.049 19.0 1.42 114 2.59 207
Blk wall,stucco ext,r-4 ext bd ins,8"thk,1/2"gypsum board int fnsh ne 534 0.201 4.1 5.83 3113 4.06 2168
se 317 0.201 4.1 5.83 1846 4.06 1286
sw 611 0.201 4.1 5.83 3561 4.06 2481
nw, 102 0.201 4.1 5.83 595 4.06 414
all 1564 0.201 4.1 5.83 9115 4.06 6349
12C-0sw:Fan wall,stucco ext,3/8"wood shth,03 cav ins, 1/2"gypsum nw 24 0.091 13.0 2.64 64 2.21 54
board int fnsh,2N4"wood fan,16"o.c.stud _..
Partitions
12C-Osw:Frm wall,1/2"gyp.bd ext,M 3 cav ins,1/2"gypsum board int 270 0.091 13.0 2.64 713 1.31 354
fnsh,2N4"wood frm,16"o.c.stud
Windows
2A-2ov:2 glazing,cir low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" ne 7 0.330 0 9.57 66 17.7 123
thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.33 ft overhang
(3.2 ft window ht,0.8 ft sep.);6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,cir innr,1/4"gap,1/8" ne 49 0.330 0 9.57 469 17.7 868
thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.33 It overhang se 33 0.330 0 9.57 313 15.6 509
(5.3 It window ht,0.8 ft sep.);6.67 ft head ht sw 49 0.330 0 9.57 469 15.6 763
all 131 0.330 0 9.57 1251 16.4 2140
.10C-v:2 glazing,clr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" se 18 0.550 0 16.0 285 16.2 289
thk;NFRC rated(SHGC=0.70);11.83 ft overhang(6.7 It window ht,0.5 It
sep.);6.67 it head ht
2A-2ov:2 glazing,cir low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" se 33 0.330 0 9.57 313 8.52 279
thk;NFRC rated(SHGC=0.23);50%drapes,medium;11.83 ft overhang
(5.3 ft window ht,0.5 ft sep.);6.67 ft head ht
- - wrightsc3ft- 2021-Nov-3011:26:14
AF& . ...•e•.0,,.� ,�mwm Right-SJte®Uriversal 2021 21.0.07 RSU24004 Page 1
820AGL1Lot124BIk5Waterstoml820AGL_FX43AItrLp Calc=MJB FrortDoorfaces:NW
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr ,innr,1/4"gap,1/8" nw 7 0.330 0 9.57 67 26.3 184
- thk;NFRC rated(SHGC 0.31);9 ft overhang(1.4 ft window ht,0.5 ft
sep.);6.67 ft head.ht
2B-2fv:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" nw 14 0.330 0 9.57 130 .26.3 358
thk;NFRC rated(SHGC=0.31);9 ft overhang(6.8 ft window ht,2 ft sep.);
6.67 ft head ht
2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/8" nw 33 0.330 0 9.57 313 16.6 543
thk;NFRC rated(SHGC=0.21);50%drapes,_medium;1 ft overhang(5.3
ft window ht,0.83 ft sep.);6.67 ft head ht
Doors
11 JO:Door,mtl fbrgl type nw 20 0.600 6.3 17.4 355 17.6 359
Ceilings
1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 cell ins,1/2" 1835 0.032 30.0 0.93 1703 1.69 3100
gypsum board int fnsh
Floors
22A-tpl:Bg floor,light dry soil,on grade depth 212 0.989 0 28.7 6080 0 0
41- Wtriightsc3 t- 2021-Nov-3011:26:14
a=. .-"• A imam RigIt-Sute@Uriversal 2021 21.0.07 RSU24004 Page 2
820AGL1Lot124BIk5Waterstore1820AGL_FX43AILnp Calc=MJB Frort Door faces:NW
Job: Lot 124 Block 5 Waterston...
DEL-AIR Project Summary Date:
xamNG•nw CONDITIONING Entire House By: pcs
DEL AIR HTG,A/C& REFRIG. INC
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.bEL IR.COM
Project • •
For: ADAMS HOMES
5358 San Benedetto Place,Fort Pierce,FL 34951
Notes: JA8-18-15
Change to 3.0 ton 2/16/16 S.Finch
L.S. 1-13-21 VWK
Design Information
Weather: St Lucie Co Inti,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 41 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 29 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 57 grAb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 24273 Btuh Structure 19072 Btuh
Ducts 4220 Btuh Ducts 5777 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 28493 Btuh Use manufacturer's data y
Rate/swing multipplier 1.00
Infiltration Equipment sensible load 24849 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3364 Btuh
Ducts 1.403_ Btuh
Central vent(0 cfm) 0 Btuh
Heat'ngg coolingg (none)
Area(ft2) 1820 182D Equipment latent load 4767 Btuh
Volume(ft3) 18350 18350
Air changes/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 29616 Btuh
Equiv.AVF(cfm) 116 61 Req.total capacity at 0.75 SHR 2.8 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model 25HBC537AP030 Cond 25HBC537AP030
AHRI ref 204863289 Coil FX4DNF043L
AHRI ref 204863289
Efficiency 8.5 HSPF Efficiency 12.5 EER,15.5 SEER
Heating input Sensible cooling 26250 Btuh -
Heating output 34600 Btuh @ 47OF Latentcooling 8750 Btuh
Temperature rise 27 OF Total cooling 35000 Btuh
Actual airflow 1167 cfm Actual airflow 1167 cfm
Airflowfactor 0.041 cfm/Btuh Airflow facto r 0.047 cfm/Btuh
Static pressure 0.40 in H2O Static pressure 0.40 in H2O
Space thermostat Load sensible heat ratio 0.84
Capacity balance point=36 OF
Ipuup8 kW, Output=25800 Btuh,100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
Att _PW wrightsoft' 2021-Nov-3011:26:14
.C(:;k Right-Sute®Universal 2021 21.0.07 RSU24004 Page 1
820AGL1Lot124Blk5Waterstone1820AGL_FX43AItnQ Calc=MJB Frort Door fams:NW
! DEL-AIR Right-JO Worksheet Job: Lot 124 Block 5 Waterstone 1...
KIMG•am cormmaMr Entire House Date:
By: DCS
DEL AIR HTG,A/C&REFRIG. INC
531 CODISCO WAY,SANFORD,FL 32771 Phore:407-333-2665 Fax407-333-3853 Web:W W W.DELAIR.COM
1 Room name Entire House BDRM2
2 Exposed wall 212.0 ft 36.0 ft
3 Room height 10.0 ft d 10.0 ft heat/cool
4 Room dimensions 13.0 x 13.0 ft
5 Room area 1835.0 fR 169.0 ftz
Ty Construction U-value Or HTM Area (ftz) Load Area (ft-) Load
number (BtuM-fl (Btuh/ftz) or perimeter (fl) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/Pro Heat Cool
__-- ne --_---
6 W.-__. 166_19ad- __ _ . _ 0.049 ne 1.42 , _259 20 _ _._.28. __ _ 52 _-_0 0 __0
IN Blk mall,stucco ext 0.201 ne 5,83 4.06 590 534 3113 2168 100 100 583 406
2A-2ov 0.330 ne 957 17.70 7 0 66 123 0 0 0 0
2A-2ov 0.330 ne 957 17.70 49 0 469 868 0 0 0 0
11 W _.. 168 19ad -_ -- -0.049_se --- __ -_ -_- -_ _
_1A2 __259 -_ _20 -__20 _ .__28 -- _52 .___ _. 0 _ _____0 -0 __ __...0
vhBlk wall,stucco eM 0.201 se 5.83 4.06 400 317 1846 1286 130 114 663 461
1OC-v 0.550 se 15.95 1620 18 18 285 289 0 0 0 0
2A-2ov 0.330 se 957 1557 33 8 313 509 16 4 156 254
2A-2ov 0.330 se 9.57 852 33 33 313 279 0 0 0 0
W.:.._ 16B 19ad___. __ Q,049_,w __ 142._,. 259 . _...._.;20, _ _20__ 28._-.__._ 52.__. 0__ _._. _0 _ .:__..,_0 _ _._._0
Blk wall,stucco ext 0.201 sw 5.83 4.06 660 611 3561 2481 136 130 758 528
- -- .2A-2ov__-- - - . .. _--_0330 -sw- 957 ._. 155.7 - 49__._. - 13 _469 - - 763 -0 --- 0 - - 0. . .___--0.
12C-Osw 0.091 nw 2.64 221 65 24 64 54 0 0 0 0
2A 2ov 0330 nw 957 2622 7 0 67 184 0 0 0 0
2B-2fv 0330 nw 957 2632 14 0 130 358 0 0 0 0
11J0_-____ _____ ___ .0.600 .nw __17.40 _._1758______-20 ____ _.. 20 _.___355 -----,359 ._.._ .___0 ___ __-0 - -----0 __.-_0
W.,. _ 1613-19ad -- - 0.049 nw -1.42 ___,259 - 20 20 -28 - 52_.. 0 - - 9 - - 0 - -0
V+1 Blk mall,stucco exl 0.201 nw 5.83 4.06 135 102 595 414 0 0 0 0
._._._--; 2A-2ov.-___.__.__- ___ 0.330 nw __ 957_____16.61_.-------33 _ ____-0_ ___313 ___. 543 _. . .-._.0 _ _.. _0 ..R _.._ _. _0
P. --- 12C-Osw --- _--_ ___ _0.091 .-_ - - _-2.64,____131-- ___ 270 --___270 _. _71.3 _354._. _0,,__
166-30ad_ ----- --- --.-0.032 . - __0-. ._ O --- -- 0.
_ __0.93___.-1.69 _ .__-1835 _ 1835 .. _�1703 _3100 _-169 _ 169. .__ __157 .-286
F_____ 22A-7p1_ ..____. __ .,989 _- _ 28.68 __0.00- _ , 1835 _ „_- -212 ._, _-6080 _ 0, _ _ 169 _ 36 ,1033 0
6 c)AED exausion 149 25
Envelope lossIgain 20569 14487 3349 1961
12 a) Infiltration 3704 1035 691 193
b) Room ventilation 0 0 0 0
13 Internal gains: Oecupants@a 230 5 1150 0 0
Appliances/other 2400 0
Subtotal(lines 6 to 13) 24273 19072 4040 2154
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 24273 19072 4040 2154
15 Duct loads 17% 30% 4220 5777 17% 30% 702 652
Total room load 28493 24849 4742 2806
Air required(dm) 1167 1167 194 132
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
AC �}.F wr➢ghtsoft^ 2021-Nov-3011:26:14
CP. .. Right-Sute®Uriversal 2021 21.0.07 RSU24004 Page 1
820AGULot124Blk5Waterstone1820AGL-FX43AItnp Calc=MJ8 Frort Door faces:NW
' �nnxDEL--AIR Right-J®Worksheet Job: Lot 124 Block 5 Waterston 1
rc-am cmmmoxmc Date:
Enthe House
By. DCS
DEL AIR FffG,A/C&REFRIG. INC
531 CODISCO WAY,SANFORD,FL 32771 Pho6e:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM
1 Room name BATH 2 BDRM3
2 Exposed wall 6.0 ft 13.0 ft
3 Room height 10.0 ft heaUmol 10.0 ft heaUmol
4 Room dimensions 13.0 x 6.0 ft 13.0 x 13.0 ft
5 Room area 78.0 ftz 169.0 ftz
Ty Construction U-value Or HTM Area (ft) Load Area (ftz) Load
number (Btuh/ftz-`l (BtuM') or perimeter (ft) (Btuh) or perimeter (ft). (Btuh)
Heat Cool Gross N/PiS Heat Cool Gross N/P/S Heat Cool
6 W 166 19ad_ _. 0.049 ,ne - - _
._1.42 -_ 259 0 _ .__ 0 _ _0 _ 0 0 __ 0 _ _ _0 __ -0
V)/ Blk vall,stucco eM 0.201 ne 5.83 4.06 T O 6 0 0 -f 0 0 0 0
2A 2ov 0.330 ne 957 17.70 0 0 0 0 0 0 0 0
2A-2ov 0.331 _ne___._957 -_W 17.70 _Q __. ---0 -_--_ -_0_ _0 0__ __ 0_..---_-_.9 _-, Q
11 W _-168-19ad 2 0.049-.se_ 1,4 `_- .259_.._ 0 .._. _ _ _
0 -- --0 0 - -- - �- - 0
VV��II Blk vsll,stucco ext 0.201 se 5.83 4.06 0 0 0 0 0 0 0 0
I--G 1OC-v 0550 se 15.95 1620 0 0 0 0 0 0 0 0
I��G 2A-2ov 0.330 se 9.57 1557 0 0 0 0 0 0 0 0
2A-2ov - -- 0330 .se_ _.9.57 - 8.52 0 _ 0 _ 0 _ 0 -.-.. _ 0 0 . 0 _0.
W 16B 19ad _..__ _ _ _.0,049 sw., _1.42 _._. 259 _._.0 . ._ 0 __. __0 _ 0--._ _ .0 __-_ _-_0._._ _.._Q _ . _..0
VV��// Blk vsll,stucco ext 0.201 sw 5.83 4.06 60 60 350 244 130 114 663 461
-_ -G-2A-2ov_ .--_. --_--- _ - ---__0.330 -sv- 957----_1557 _ _0 _--- 0 --- -.. ._0
12C-Osw 0.091 nw 2.64 221 0 0 0 0 0 0 0 0
2A-2ov 0230 nw 957 2622 0 0 0 0 0 0 - 0 0
2B-2fv 0330 nw 957 - 2632 0 0 0 0 0 0 0 0
_-__- 11 J0.___ _ ___ .____ 0.600_-nw _ _VAO.. 1758 -------0_ . _ 0 __ 0._._. . ___0 ___.__,_-__0______ -0 -0
W -_ 166-19ad--cco_ ____ 0.049 nw. __ 1.42 _ 259 --0 - _---_ 0 _ 0 0 0 --_ - -0 _ 0
t __0
Blk wall,stu ext 0.201 nw 5.83 4.06 0 0 0 0 0 0 0 0
-G 2A-2ov.-----_._-__._ _ ._ .0.330.nw_- ...957 _. 16.61 .. _._.---0 _ ---.--0 --. _0- _ -. -0 -..----._-0____.-.__0____.. .0 _- 0
..12C-Osw .- _ _.A0.091 -_-_ 2.64 131 0 _ 0 0 _.. ._ .-_0..._ _0 -. __-- 0 ._0 ,._ 0.
C__ 16B-30ad.._ --- 0.032 - -- 0.93 1.69 _,. 7_8 -- 7$ 72- 132 169.-- 169.. 157 .286
F - - - 22A-too _ 0.989 28.68 .._._0.00 78 - - 6 - 172 _ 0 -.. - 169 13 373 0
6 c)AED excursion -21 67
Envelope loss/gain 594 354 1349 1068
12 a) Infiltration 115 32 249 70
b) Room ventilation 0 0 0 0
13 Internal gains Occupants@ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 709 386 1598 1138
Less extemalload 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 709 386 1598 1138
15 Duct loads 117% 30% 123 117 17% 30% 278 345
Total room load 833 503 1876 1483
Air required(cfm) 34 24 77 70
Calculations approved bVACCAto meet all requirements of Manual J 8th Ed.
i"1.1- wrigf�tsoR�
Aft Right-Sute@Universal 2021 21.0.07 RSU24004 2021-tJov 301 Page 2
820AGL\Lot12413MWaterstone1820AGL-FX43AILnp Calc=MJS FroriDoorfaees:NW g
DEL--AIR Right-J®Worksheet
Job: Lot 124 Block 5 Waterston 1.-.
HFnnxc•nmemmmar r Date:
Entire House s�: Dcs
DEL AIR HTG, A/C&REFRIG. INC
531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM
1 Room name DINING/FOYER DENBDRM4
2 Exposed wall 25.0 ft 31.0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heaVcool
4 Room dimensions 1.0 x 276.0 ft 13.0 x 13.0 ft
5 Room area 276.0 ftz 169.0 ftz
Ty Construction U-value Or HTM Area (ftz) Load Area (ft2) Load
number (Btuh/ftz-cq (Btuhfftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool
-___. ___ -_
6 W a._ 166:19ad-_-_
0049 ne 1.42 __ 2,59. _-_,..0_.__.. _ 0 _ . __0- - _ _ 0 ,- __ . _0 _. _ 0 -.- 0 -_ ._-__0.
Blk well,stuao ext 0.201 ne 5.83 4.06 0 0 0 0 50 50 291 203
2A-2ov 0,330 ne 9.57 17.70 0 0 0 0 0 0 0 0
- - 2A-2ov - - 0.330 .ne. 957 _-,17.70 - -0 __0 .. _0 - - 0 0_ - 0 - 0
11 W_.- 16B 19ad_----- - - -- -- _0A4-9__se 1;42 _ - 259 _ - ..--0 - - 0 - - -- 0 0 _ 0 - - -0
VV�/ Blk wall,stucco ext 0.201 se 5B3 4.06 0 0 0 0 0 0 0 0
[ -G 1OC-v 0.550 se 15.95 1620 0 0 0 0 0 0 0 0
��G 2A-2ov 0.330 se 957 15.57 0 0 0 0 0 0 0 0
2A-2ov _.0330 se -_9.57.-_.- 852 _-__,0 .-_.._. 0 0 0
W 166.19ad.-=- - 0, 4. _sy _ 1.42 -259 -.. _:_0 . 0 -0 - 0 -. 0 0 _.. 0 0
VI/ Blk wall,stucco ext 0.201 sw 5.83 4.06 110 77 451 314 130 130 758 528
-----( 2A-2ov__.___--_--- ---__0.330 -sw 9,57 1557 33 _ _ 6 --- - 313-- 509 . . _ --0 -- - - - 0 - -- -- 0
12C-Osw 0.091 nw 2.64 221 65 24 64 54 0 0 0 0
2A-2ov 0.330 nw 957 2632 7 0 67 184 0 0 0 0
2B-2fv 0.330 nw 957 2622 14 0 130 358 0 0 0 0
11JO.__. ______.- _- _. -_.. 0.600.-nw _17.40 ___ 1758 20_ ___ - 20 _ 355 359
W 16B-19ad 0.049 nw _1.42 ._ 259 _ _ -0 _ _ . 0 _•-0 0 _ 0 0 _ _ 0 0
W Blk%all,stucco ex( 02o1 nw 5.83 4.06 5 5 27 19 130 97 567 395
I--G 2A-2ov-._-._ _. - 0.330 nw 957_ _ _.16.61 _ -_. A -_ _ 0 _ __. .._-0 0 __ 33 _0 _.. _ 313 543
12GOsrr _ 0.091 ._= 2.64 ___.131 70 _. _ 70 - ._•_185 _ _ .92 _ _0
C, 16B-30ad- 0.032 0.93 1,69- _ _ 276 - _ -276 0 . _ 0 0
___ 256 466 169 - 169 _-_ 157 _ 286
F - 22A-tpl _ ____ . „0.989 - - 28.68 - - 0.00 276 25 717 _ 0 169 31 889 0
6 c)AED excursion 327 161
Envelopeloss/gain 2565 2681 2975 2115
12 a) Infiltration 345 97 595 166
b) Room ventilation 0 0 0 0
13 Internal gains: OcaupantsQn 230 1 230 0 0
Applianoes/other . 01 0
Subtotal(lines 6 to 13) 2910 3008 3570 2281
Lem extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2910 3008 3570 2281
15 Duct loads 17% 30% 506 911 17% 30% 621 691
Total room load 3416 3919 1 4191 2973
Air required(dm) 140 184 172 140
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
- wrightsoft^ 2021-Nov-3011:26:14
Right-Sute®Uriversal2021 21.0.07 RSU24004 Page
820AGL\Lot124Blk5Waterstone1820AGL_FX43AIt.rp Calc=MJ8 Front Door faoes:NW
Job: Lot 124 Block 5 Waterston 1
s ...
DEL--AIR Right-J®Worksheet
xtnnxrs'amrwimrtrowwc Entire House Date:
By- DCS
DEL AIR HTG,A/C&REFRIG. INC
531 CODISCOWAY,,SANFOFb,FL32771 Phorn:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM
1 Room name FAMILY RM MSTR BDRM
2 Exposed vsll 13.0 ft 41.0 It
3 Room height 10.0 It heat/cool 10.0 ft heat/cool
4 Room dimensions 13.0 x 22.0 It 14.0 x 17.0 ft
5 Room area 286.0 ftz 238.0 ftz
Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load
number (BtuM-co (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
L
Heat Cool Gross N/PJS Heat Cool Gross N/P/S Heat Cool
- -- - - - -- - --
6 W 16B 19ad-__- - -- 0.049__ne• _1.42 _ 25.9 _---_20 . _ __20 --_--_28 52
W Blk v dl,stucco ext 0.201 ne 5B3 4.06 0 0 0 0 170 154 896 624
2A-2ov 0230 ne 9,57 17.70 0 0 0 0 0 0 0 0
2A-2ov _-- -_ _ _ 0330 _ne_. __9.57 1770_______ 0 _ __0 . O _ - 0 .__ . 16__ _0_ 156 289_
_0.049 se_ 1.42-_ ,259 .__ 2020 _._28 52_ -- _0 -
_ -- 0
Blk voll,stucco ext 0.201 se 5.83 4.06 130 79 463 323 140 124 721 502
10C-v 0550 se 15.95 1620 18 18 285 289 0 0 0 0
2A-2ov 0230 se 9.57 1557 0 0 0 0 16 4 156 254
2A-2ov _ r_..0230- se _.__.957 __._. 852 33 .__ 33 ._-- _•_313 __279 .._, 0
1-6B-19ad _ ._-_ ._. .._0.049 _sW__ ._._ 1.42- ,---2.59 _...._20-_-- -2.._._ .__28 _-.. _52 _--- __0---
1��/I Blk v dl,stucco ext 0.201 sw 5.83 4.06 0 0 0 0 100 100 583 406
_r-_ G 2A-2ov_ _- _--_ __ _0230 sw _ _- 957--- 1557 -_0 •_-___ 0 _. _.-_0-- _
12C-Osv 0.091 nw 2.64 2.21 0 0 0 0 0 0 0 _ 0
2A-2ov 0230 nw 957 2622 0 0 0 0 0 0 0 0
213-21y 0.330 nw 9.57 2622 .0 0 0 0 0 0 0 0
11J0..__. ' __ -_. .__ 0.600 .nw. _ .17.40. __.-1758 . .. __._0._. ._.._0.__-.--._-0 .-- -._._.0.___ __0__- _._0__._ _...-0 .. . - __.0
W__-- 1613-19ad _--- _ 0.049 nw -- -1 A2 _ 259 - -20 _-- - - 20 _ 28 52 -- -- 0 -- 0 _ ._ 0 _ _0
V/ Blk v�sll,sluom ext 0.201 nw 5.83 4.06 0 6 0 0 0 0 0 0
� 2A-2ov-_.- ---_0.330 .nw_ _- .-957. 16.61 ._-_ __._-0.._.___-0..__. _.-.-0 -0 __-- _._0 ----...--_0._.. _-- -0 ._._-_-. ._0
P. .12C-Osm_.-_ ._---__ _ ---- 0.091 _ . 2.64 0 .___ 0..._.,_. __.0._- 0 .,_ ---0 0.
131. _� --0
C___---_ 16B30ad.- _.... F ._ 0.032 -0.9.3 ti._ 1- 9 -286... _._286 265 _4> .._.___238 _. .--238 ___.._221 .--- --402
F. _0.989 _ 28.68 _,-0.00 _ __286 _ -13--- 373 _ 0_-_ 238 _41 _ 1176 _ _- 0
6 c)AED excu sion -124 -74
Envelope lo--Jgain 1813 1457 3909 2404
12 a) Infiltration 403 113 787 220
b) Room venfilation 0 0 0 0
13 Internal gains: Occupants@a 230 3 690 1 230
Appliances/other 0 600
Subtotal(lines 6 to 13) 2216 2259 4696 3453
Less extemalload 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2216 2259 4696 3453
15 Duct loads 171/6 30% 385 684 17% 30%1 816 1046
Total roam load 2601 2944 5512 4499
Air required(cfm) 107 138 1 1 226 211
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
�ti wrightsoft- 2021-Nov-3011:26:14
.4M RigIY-Sllte®Universal 2021 21.0.07 RSU24004 Page 4
820AGL1Lot124BIk5Waterstore1820AGL_FX43AItnp Calc=MJ8 Frort Door fao9s:NW
%DEL--AIR Right-J®Worksheet Job: Lot 124 Block 5 Waterston 1...
�nnxc•amcocmmoxmo Entire House Date:
By: DCS
DEL AIR HTG,A/C&REFRIG. INC
531CODISCO WAY,SANFORD,FL32771 Phone:407-333-2665'Fax:407-333-3853 Web:WWW.DELAIR.COM
1 Room name M BATH M WIC
2 Exposed wall 12.0 8 0 It
3 Room height 10.0 ft heaU000l 10.0 ft heat/cool
4 Room dimensions 1.0 x 119.0 ft 7.0 x 7.0 ft
5 Room area 119.0 ftz 49.0 ftz
Ty Construction U-value. Or HTM Area (ftz) Load Area (ftz) Load
number (Btuh/ftz-19 (Btuft tz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W . --- 161j19ad___.__...__ .049 .-ne. _1.42 259 ___0 -- 0 9 _. . 0 ._. ._ 0 . _._, _- _0 _,.,...0.
Blk gall,stucco ext 0.201 ne 5.83 4.06 120 113 659 459 0 0 0 0
2A 2ov 0330 ne 9.57 17.70 7 0 66 123 0 0 0 0
-2A-29v _ ---_ _ -_ .9330 -ne- _ 957-___17.70 _--- ___0 ._._0_0 _ __ --
11 W_.._ 16B-19ad----- 0- - 0 - 0 ---0 _._._
- -- ----0,049 -se, ._. _1.42 ___ 2�59- - ----0 -- -- --0 ---0 - -0 O 6 6-.0
VV��11 Blk%all,stucco e)d 0.201 se 5.83 4.06 0 0 0 0 0 0 0 0
I--G 1OC-v 0.550 se 15.95 1620 0 0 0 0 0 0 0 0
�L__GG 2A-2ov 0.330 se 9.57 1557 0 0 0 0 0 0 0 0
2A-2ov_ _.__0_40 -se. _ _957__.___852 __. __....- -- 0 ___. ___0_ __ __0
W- ,16B-19ad_. .._ _ .. _.. . _ 0.049, _sw ___ A __-__259 _-0-_--- __.0 _0. _.._. _,0 90
VI! Blk vlall,stucco eM 0201 sw 5B3 4.06 0 0 0 0 0 0 0 0
-� 2ov_ - - -- 0,330 _sw_ 957 1557 _9 - -- -0 --- -0 - -O -0 0 - 0 0
12C-Osw 0.091 nw 2.64 221 0 0 0 0 0 O 0 0
2A-2ov 0,330 nw 957 2632 0 0 0 0 0 0 0 0
2B-2fv 0.330 nw 957 2622 0 0 0 0 0 0 0 0
L,--D ______. _.0.600 nw. _..-.17A0_.- 1758.- __.___0___ --_.0 - ...........0 __ ._. A _. .____o _. _.-_._0 ___..___0 ,_._.0
W 1613-19ad ._ _. 0049 nw. 1A2 2.59 0 0 0, _ 0 ,._....- 0 0 0 0
Blk vall,stucco ext 0.201 nw 5.63, 4.06 0 0 0 0 0 0 0 W 0
2A-2ov__.._ _.0.330_nw _ _ 957_ __._.16.61. _ 0.;__. 0 _ _ _..-0 _. - 0 ..__0 _ _ '._.0 ._ _ __0 _,..,'0
P, 12C-Osw- - .._ _ _0.091 .. _ 2.64 121 _0 - _0- -0 -
_C -_ 161330ad - _ _ 0.032 ._- 093 T 1,69_ .-119-_-.__ 119 . __-_110 _201 ___. __49 _49 45 _83
F 22A-tol _- .,0.989 --28.68 ._. 0.00 119 12 344 - 0 49 0 6 0
71
6 c)AED excursion -44 -4
Envelope losstgain 1180 739 45 78
12 a) Infiltration 230 64 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants@ 230 0 0 0 0
Appliancestother . 0 0
Subtotal(lines 6 to 13) 1410 803 45 78
Less external load 0 0 0 0
Lesstransfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1410 803 45 78
15 Duct loads 17% 30% 245 243 17% 30% 8 24
Total room load 1656 1046 53 102
Air required(cfm) 681 49 2 5
_ Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-PI.F 2021-Nov-3011:26:14
Right-Sute®Uriversal 2021 21.0.07 RSU24004 Page 5
820AGL1Lot124Blk5Waterstone1820AGL-FX43AItnp Calc=MJ8 Front Door faces:NW
; DEL--AIR Right-J®Worksheet n Job: Lot 124 Block 5 Watersto 1...
runMc•nmcmmmotmtc Entire House Date:
By: DCS
DEL AIR HTG,A/C&REFRIG. INC
531 CODISCOWAY,,SANFORD,FL32771 Plune:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM
1 Room name KITCHENMOOK LAUNDRY
2 Exposed wall 29.0 It 6.0 ft
3 Room height 10.0 ft heatbool 10.0 It heaUwol
4 Room dimensions 1.0 x 246.0 ft 6.0 x 6.0 It
5 Room area 246.0 ft2 36.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ftz) Load
number (Bluh/ft2-9 (Btuh/It2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W - 166 19ad-_ . _ - _ -_ 0.049 ne _1,42 «. 259 0 -. -0 _0. __ 0
oo _-- 0 _ - . _ _ -_ _0 - _ 0
Blk wall,stuo e)d 0201 ne 5.83 4.06 150 117 684 476 0 0 0 0
2A-2ov 0.330 ne 957 17.70 0 0 0 0 0 0 0 0
2A-2ov 0230 _ne_ 9.57 17.70 33 0 313 579 0 0 0 0
0.049 _se ..1.42 259 - _. 0 - ---0- - 0- - -0- 0- -- 0 _ --0 - 0
- ----- - - ._�--- - - --- _. - -
Blk mall,stucco e)d 0.201 se 5.83 4.06 0 0 0 0 0 0 0 6
I-G 10C-v 0550 se 15.95 1620 0 0 0 0 0 0 0 0
2A-2ov 0230 se 957 1557 0 0 0 0 0 0 0 0
2A-2ov 0.330 se 957 852 0 0 0 0 0 0 0 0
0.049.-_sw -1.42- _-._2 59 _._ .___.,0,.._.___ A ._-..:w..0 ,_ 0 ..
_. _ - Q__. .__ _0...___ .. o 0
Blk vtell,stucoo ext 0.201 sw 523 4.06 0 0 0 0 0 0 0 0
t-_C 2A-2ov 0.330 _sw_ 957 1557 0 0 0 0 0 _ 0 _ _ 0 0
12C-Osw - _ -0.091 nw 2.64 2.21 0 - - ---0 --0 -0 0^ 0 0 6
2A-2ov 0330 nw 957 2632 0 0 0 0 0 0 0 0
-C 2B-2fv 0.330 nw 9.57 2632 0 0 0 0 0 0 0 0
11J0__.__ __ ..._-_. .._ _ 0.600 .nw. 17AO- ._.-1758 _.__..__0_ __ _.0 _ .___._.0 -. __ _ 0 -.._. _ 0__ _._-_0_:__ _. 0 ____..0
W _._ 16B-19ad_ LL--- _-- 0.049 nw _ __1.42 .259 _--.-_0 . -- 0 _ -- 0 0 ----- -0 .._ 0 _ _0 _:0
VI! Blk yell,stucco eM 0.201 nw 5.83 4.06 0 0 0 0 0 0 0 0
__.G 2A-2ov. _._ _-.,.0.330 nw. _._. .957.:-__.16.61 --0 ------ ..._.0 ...__ ._. .0 ---- _ __0__. __- .-0. .0
P - 12C-Osw-- - 0.091. ._:-_ _-„2.64.._._._131 _. ._.__140.._-- .140 369 __. _183_.,.__. __60 __... __60 158 _ --79.
._._0.93.. 1.,69.. ._246 - 246 228 _._. _ 41IS __. _ 36 .. - 36 -- W -._. .__.61-
F -- 22A-h)l ._4Y _ .0 989.. . 28.68. 0.00 ._ -246 - 29 832_ ._ _ 0 .. _ 36
6 c)AED excursion -125 -39
Envelope losstgain 2426 1529 364 101
12 a) Infiltration 288 80 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants@ 230 0 0 0 0
Appliances/other 1200 600
Subtotal(lines 6 to 13) 2714 2809 364 701
Less e)demal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2714 2809 364 701
15 Duct loads 17% 30% 472 851 17% 30% 631 212
Total room load 3186 3660 427 913
Air required(cfrn) 130 172 17 43
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-Flawrightsoft^ 2021-Nov-3011:26:14
. A """ """'" `"'^ Right-Sute®Uriversal2021 21.0.07 RSU24004 Page 6
820AGL�Lot124BIk5Waterstore1820AGL_FX43AItnp CaIc=MJB FroriDooriaces:NW
RDEL-AIR Duct System Summary Job: Lot 124 Block 5 Waterston...
NEGTNis•tu8 CONUM81 G Date:
Ente House B .
ir y- Dcs
DEL AIR HTG,A/C& REFRIG. INC
531 CODISCOWAY,,SANFORD,FL32771 Phore:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM
Project • •
For: ADAMS HOMES
5358 San Benedetto Place,Fort Pierce,FL 34951
Heating Cooling
External static pressure 0.40 in H2O 0.40 in H2O
Pressure losses 0.06 in H2O 0.06 in H2O
Available static pressure 0.34 in H2O 0.34 in H2O
Supply/retum available pressure 0.170/0.170 in H2O 0.170/0.170 in H2O
Lowest friction rate 0.300 in/100ft 0.300 in/100ft
Actual airflow 1167 cfm 1167 cfm
Total effective length(TEL) 113 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (in) (in) Mat Ln(ft) Ln(ft) Trunk
BATH 2 h 833 34 24 0.394 4.0 Ox 0 VI Fx 16.3 70.0
BDRM 2 h 4742 194 132 0.366 8.0 Ox 0 VI Fx 22.9 70.0
BDRM3 h 1876 77 70 0.433 6.0 Ox0 VI Fx 8.6 70.0
DENBDRM4 h 4191 172 140 0.409 7.0 Ox0 VI Fx 13.2 70.0
DINING/FOYER c 3919 140 184 0.444 7.0 Ox 0 VIFx 6.5 70.0
FAMILYRM c 2944 107 138 0.330 7.0 Ox 0 VIFx 17.9 85.0 st1
KfrCHENMOOK c 3660 130 172 0.323 8.0 Ox 0 VIFx 20.1 85.0 sti
LAUNDRY c 913 17 43 0:316 4.0 Ox 0 VIFx 22.7 85.0 st1
M.BATH h 1656 68 49 0.317 5.0 Ox 0 VI Fx 22.2 85.0 st1
M.W lc c 102 2 5 0.318 4.0 Ox 0 VI Fx 21.9 85.0 st1
MSTR BDRM h 5512 226 211 0.300 8.0 Ox 0 VI Fx 28.2 85.0 -st1
Supply Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
sti PeakAVF 550 618 0.300 578 14.0 0 x 0 VinlFlx
wrightsofta 2021-Nov-3011:26:15
•�•+ �.�.•. •w. ,w� Right-Sute@Uriversal202l2l.D.O7RSU24004 Page
820AGL1Lot124Blk5Waterstone1820AGL_FX43AILnQ Calc=W8 Frort Door faces:NW
DetailReturn Branch
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) _ FR (fpm) (in) (in) Opening(in) Mat Trunk
rbi Ox 0 1167 1167 0 0 0 0 Ox 0 VIFx
wrigf7tsafita 202144ov-3011:26:15
•w..k•a,�M1„mow- Right-Sule®Uriversal2021 21.0.07 RSU24004
Page 2
820AGL\Lotl24BIk5Waterstore1820AGL_FX43AILnp Calc=MJ8 Frort Door iaoes:NW
le4t ®� Hddi V
�Eppd�FI 9®R0067
g Fa 14xB Iwcd 5" bath duct —°� NN
LANA! M
13o to roof cap
12xI2 rag w/ standard 70 �D N
cfm bath fan g Q M M
M
14xit1*cd esh h'da J00 B' - tN M
16x76 r.g 0- O
A 16z16 rag TH 7
4
5" bath duct B. 4Y pAMLY ROOM 14x14 rag 4' 2 cd a 11
to roof cap
w/ standard 70 a..w �12xliI-d
cfm bath fan Br4140
10z1 ra fir.
7-
g
k 1Ox6 iw.d v
50g7y.� 10. d c
xQImQY 14' S. 70 �a
TC,E
N m
z .
O
�KI C.HE14 24x B fb ag N
,®—, an4�Ha Roots �
q'dryer duct 17D B. 7• vAan'.ca.n LLJ
to roof
/dryer vent boz 6 14xB lwcd 1 85wed Q
xL12M B.4;wild 12x12 rag
42X42 A/C SLAB „ 7-
BY BLDR MIN zxlz r.g
2' FROM WALL --- FOYER
Uu� �121410--" W
E)ETJR0011 Z
(n O
W F
z (N
O to Of
_ LLJ
eua�,w.vw - Nea�oa UO Q Y
--------- — --------------- --;
—i------------------- Q J
3.0 TON W/5KW 0240V 1PH 0 m N
se.l..P%e'_7 0' j Q cV -t z -t
b ldrt.rm by O - N 0 m
I N _
W > z
-j Z p W
NOTE TO BUILOER:MUST PROVIDE UNRESTRICTED J Q H m F- Q
1 INCH UNDERCUT BELOW DOORS TO HABITABLE ROOMS 7 J O D .4IY'
Transfer ducts/grills sized in .mplian.e m IL J (n Q m
with Florid.Residential Building Cede-M7602.4.
balanced return a v.
EXCEPTIONS 1-3
Rating
5 Must have a minimum clearance of 4 inches around the air handler per the State Energy code. All duct has an r=B insulation value.