Loading...
HomeMy WebLinkAboutRevisions OFFICE USE ONLY: 1 DATE FILED: 1 �- 1 �' \ PERMIT REVISION FEE: RECEIPT# . PLANNING & DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE RECEIVED FORT PIERCE,FL 34982-5652 (772)462.1553 NOV 3 0 2021 APPLICATION FOR BUILDING PERMIT REVISIONS St.Lucie County PROJECT INFORMATION Permitting LOCATION/SITE ADDRESS: 5379 Lugo Street (51/1) DETAILED DESCRIPTION OF PROJECT REVISIONS: Due to equipment shortages,the air handler being installed with have a different serial#than was originally called for. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CRC1330146 ST. LUCIE CO CERT. #: BUSINESS NAME: Adams Homes of Northwest Florida,INC QUALIFIERS NAME: William Bryan Adams ADDRESS: 3000 Gulf Breeze Parkway CITY: Gulf Breeze STATE: FL ZIP: 32563 PHONE(DAYTIME): 772-905-8394 FAX: OWNER/BUILDER INFORMATION: NAME: Adams Homes of Northwest Florida,Inc ADDRESS:3000 Gulf Breeze Parkway CITY: Gulf Breeze STATE: FL ZIP: 32563 PHONE(DAYTIME: 772-905-8394 FAX: ARCHITECT/ENGINEER INFORMATION: NAME: Keesee Associates ADDRESS: 945 South Orange Blossom Trail CITY: Apopka STATE: FL ZIP: 32703 PHONE(DAYTIME): 407-880-2333 FAX: n 9A PR r SLCCC: 9123109 ,F Revised 06130/17 r �.. R. yo 4�r lr7:A J - f i.t FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 51 Block 1 Waterstone 1820 DGL Builder Name: ADAMS HOMES Street: 5379 Lugo Street Permit Office: City,State,Zip: Fort Pierce,FL,34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL,ST_LUCIE_CO_INTL County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type$2120.0 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1850.00 ft2 b.Frame-Wood,Adjacent R=13.0 270.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 11.Ceiling Types (1900.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1820.00 ft2 6. Conditioned floor area above grade(ft2) 1820 b.Knee Wall(Vented) R=19.0 80.00 ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 7. Windows(237.2 sqft.) Description Area 12.Ducts R ft2 a. U-Factor: Dbl,U=0.33 168.74 ft2 a.Sup:Attic,Ret:Main,AH:Main 6 364 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.33 32.38 ft2 13.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a.Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl,U=0.33 18:33 ft2 SHGC: SHGC=0.31 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 4.181 ft. Area Weighted Average SHGC: 0.269 a.Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15.Hot water systems SHGC(AVG): N/A a. Electric Cap:40 gallons 9. Floor Types (1820.0 sqft.) Insulation Area EF:0.940 a.Slab-On-Grade Edge Insulation R=0.0 1820.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 16.Credits Pstat Glass/Floor Area: 0.130 Total Proposed Modified Loads: 59.99 PASS Total Baseline Loads: 64.94 I hereby certify that the plans and specifications covered by Review of the plans and 1<Z STgl; this calculation are in pliance with the F rida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. ' :ram• . PREPARED BY: Before construction is completed DATE: 11-3f)-9691 Gorrina Mahpy this building will be inspected for compliance with Section 553.908 *; I hereby certify that this build' as designed, is in compliance Florida Statutes. S� with the Florida nergy d G'Ob WTiv. OWNER/AG BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 11/30/2021 11:33 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software `�1 Page 1 of 4 "VISION FILE COPY :.FORM R405-2020 INPUT SUMMARY:CHECKLIST REPORT PROJECT Title: Lot 51 Block 1 Waterstone 18 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1820 Lot# 51-1 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone #of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5379 Lugo Street Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City,State,Zip: Fort Pierce, Family Type: Detached FL, 34951 New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS - Number Name Area Volume 1 Blocki 1820 18200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 33 ft 0 1820 ft2 ---- 0.42 0 0.58 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1820 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1820 ft2 0.11 Wood 2 Knee Wall(Vented) Main 19 Batt 80 ft2 0.11 Wood 11/30/2021 11:33 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 2 of 4 .:,FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space CavityR_Vqllip Width Height Sheathing Framing Solar Below it ornt Tn Wall Type 1 N Exterior Concrete Block-Int Insul Main 4.1 59 0 10 0 590.0 ft2 0 0 0.6 0 2 W Exterior Concrete Block-Int Insul Main 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 3 S Exterior Concrete Block-Int Insul Main 4.1 66 0 10 0 660.0 ft2 0 0 0.6 0 4 E Exterior Concrete Block-Int Insul Main 4.1 27 0 10 0 270,0 ft2 0 0.6 0 5 - Garage Frame-Wood Main 13 27 0 10 0 270.0 ft2 0 0.23 0.01 0 6 W Exterior Concrete Block-Int Insul Main 4.1 7 0 10 0 76.0 ft2 0 0 0.6 0 7 E Exterior Concrete Block-Int Insul Main 4.1 13 0 10 0 130.0 ft2 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Main None .25 3 6 8 20 ft2 2 Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 2 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft' 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 3 W 6 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 9 ft 0 in 0 ft 6 in None None 4 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 5 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 6 W 6 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 9 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 7 S 3 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 8 E 7 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 12 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 9 E 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 10 E 7 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 12 ft 0 in 0 ft 3 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 396 ft2 396 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000444 2123.3 116.49 218.7 .1381 7 11/30/2021 11:33 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 4 ,-FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:15.5 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply---- ----Return--- Air CFM 25 CFM25 HVAC# v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 364 ft2 Main 91 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar [ ]Apr [ ]Ma rl Jun rj Jul X Au rl Se [ ]Oct Nov Dec Heatin H Jan H Feb Mar [ ]Apr [ ]May Jun Jul f ]AuSep [ ]Oct XNov X Dec Ventin Jan Feb HX Mar [X]Apr [ ]May Jun Jul [ Aug Se [X]Oct X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 . 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 11/30/2021 11:33 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the EnergyPerformance Index,the more efficient the home. 5379 Lugo Street, Fort Pierce, FL, 34951 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1850.00 ftZ b.Frame-Wood,Adjacent R=13.0 270.00 ftZ 3. Number of units,if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 4 d.N/A R= ftZ 5. Is this a worst case? No 11.Ceiling Type and insulation level Insulation Area a.Under Attic(Vented) R=30.0 1820.00 ftZ 6. Conditioned floor area(ftZ) 1820 b.Knee Wall(Vented) R=19.0 80.00 ftZ 7. Windows- Description Area c. N/A R= ft Z a. U-Factor: Dbl,U=0.33 168.74 ftZ 12.Ducts,location&insulation level R ftZ a.Sup:Attic,Ret:Main,AH: Main 6 364 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.33 32.38 ftZ SHGC: SHGC=0.21 13.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.33 18.33 ftZ a.Central Unit 35.0 SEER:15.50 SHGC: SHGC=0.31 d. U-Factor: other(see details) 17.78 ft2 14.Heating systems kBtu/hr Efficiency SHGC: other(see details) a.Electric Heat Pump 34.6 HSPF:8.56 Area Weighted Average Overhang Depth: 4.181 ft. Area Weighted Average SHGC: 0.269 8. Skylights Description Area 15.Hot water systems a. U-Factor(AVG): N/A ftZ a. Electric Cap:40 gallons EF:0.94 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation .Area None a.Slab-On-Grade Edge Insulation R=0.0 1820.00 ftZ Credits(Performance method) Pstat b.N/A R= ftZ c.N/A R= ftZ I certify that this home has complied with the Florida Energy Efficiency Code for Building 4�UE:Sr, Construction through the above energy saving features which will be installed (or exceeded) o in this home before final inspection. Otherwise, a new EPL Display Card will be completed rij !/i� _ .• rfi based on installed Code compliant features. Builder,Signature: = __ Date: Address of New Home: City/FL Zip: OD:yVE'T� . *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage (EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/30/2021.11:33 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1 i DEL-AIR Manual S Compliance Report Date: Lot51 Blockl Waterstone... �s• C01MM0100 Entire.House By- ocs DEL AIR HTG,A/C& REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM Project • • For: ADAMS HOMES 5379 Lugo Street,Fort Pierce,FL 34951 Cooling Equipment Design Conditions Outdoor design DB: 90.4°F Sensible gain: 25151 Btuh Entering coil DB: 76.4OF Outdoor designWB: 77.4°F Latent gain: 4767 Btuh Entering coilWB: 63.2OF Indoor design DB: 75.0 OF Total gain: 29918 Btuh Indoor RH: 50% Estimated airflow: 1167 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC537AP030+FX4DNF043L Actual airflow: 1167 cfm Sensible capacity: 28188 Btuh 112%of load Latent capacity: 5115 Btuh 107%of load Total capacity: 33303 Btuh 111%of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 41.0OF Heat loss: 28559 Btuh Entering coil DB: 69.5OF Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Carrier Model: 25HBC537AP030+FX4DNF043L Actual airflow: 1167 cfm Output capacity: 31708 Btuh 111%of load Capacity balance: 36 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1167 cfm Output capacity: 7.9 kW 94%of load Temp.rise: 21 OF Meets all requirements ofACCA Manual S. Wrightsoft® 2021-Nov-3011:3128 �� >� .•wM�,�• Right-Sute@Uriversal202l2l.O.O7RSU24004 Page 1 ...1820DGULot51BIk1Waterstore1820DGL_FX43AILnp CaIc=MJB FrortDooriaces:W Component Constructions Job: Lot51 Block Waterstone... DEL-AIR - N Entire House By. DCs DEL AIR HTG,A/C&REFRIG.INC 531 CODISCOWAY,,SANFORD,FL32771 Phorw407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM, Project • • For: ADAMS HOMES 5379 Lugo Street,Fort Pierce,FL 34951 I Design Conditions Location: Indoor: Heating Cooling St Lude Co Intl,FL,US Indoor temperature(OF) 70 75 Elevation: 26 ft Design TD(OF) 29 15 Latitude: 28°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grAb) 2.4 56.9 Dry bulb(°F) 41 90 Infiltration: Daily range(OF) - 15 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' BtulVftz°F ftz°F/Btuh Btuh/ft' Btuh BtulVrt2 Btuh Walls 1613-19ad:Knee wall,asphalt shingles roof mat,r-19 kw ins,1/2"gypsum n 20 0.049 19.0 1.42 28 2.59 52 board int fnsh a 20 0.049 19.0 1.42 28 2.59 52 s 20 0.049 19.0 1.42 28 2.59 52 W 20 0.049 19.0 1.42 28 2.59 52 all 80 0.049 19.0 1.42 114 2.59 207 Blk wall,stucco ext,r-4 ext bd ins,8"thk,1/2"gypsum board int fnsh n 534 0.201 4.1 5.83 3113 4.06 2168 e 317 0.201 4.1 5.83 1846 4.06 1286 s 611 0.201 4.1 5.83 3561 4.06 2481 W 129 0.201 4.1 5.83 751 4.06 523 all 1591 0.201 4.1 5.83 9272 4.06 6458 Partitions 12C-0sw:Frm wall,1/2"gyp.bd ext,r-13 cav ins, 1/2"gypsum board int 270 0.091 13.0 2.64 713 1.31 354 fnsh,2"A"wood frm,16"o.c.stud Windows 2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" n 7 0.330 0 9.57 66 8.52 59 thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.33 ft overhang (3.2 ft window ht,0.8 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" n 49 0.330 0 9.57 469 8.52 418 j thk;NFRC rated(SHGC=0.23);50%drapes,medium;1.33 It overhang a 33 0.330 0 9.57 313 22.4 730 (5.3 ft window ht,0.8 ft sep.);6.67 ft head ht s 49 0.330 0 9.57 469 8.52 418 all 131 0.330 0 9.57 1251 12.0 1566 10C-v:2 glazing,clr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" a 18 0.550 0 16.0 285 16.2 289 thk;NFRC rated(SHGC=0.70);12 ft overhang(6.7 ft window ht,0.5 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" a 33 0.330 0 9.57 313 8.52 279 thk;NFRC rated(SHGC=0.23);50%drapes,medium;12 ft overhang(5.3 ft window ht,0.25 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr low-e outr,air gas,vnl fnn mat,clr innr,1/4"gap,1/8" w 33 0.330 0 9.57 313 21.0 686 thk;NFRC rated(SHGC=0.21);50%drapes,medium;1.3 ft overhang (5.3 ft window ht,0.83 ft sep.);6.67 ft head ht t -F WrightsOft- 2021-Nov-3011:3128 Right-Srite®Uriversal 2021 21.0.07 RSU24004 Pagel 1820DGL\Lot5lBlklWaterstorel82ODGL_FX43AItrLp Calc=MJ8 FrortDoorfams:W 2B-2fv:.2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" w 5 0.330 0 9.57 48 11.6 58 thk;NFRC rated(SHGC=0.31);9 ft overhang(1 ft window ht,0.5 ft sep.); 6.67 ft head ht 2B-2fv:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap,1/8" w 13 0.330 0 9.57 128 13.4 179 thk;NFRC rated(SHGC=0.31);50%drapes,medium;9 ft overhang(6.7 ft window ht,2 ft sep.);6.67 ft head ht Doors 11 JO:Door,mtl fbrgl type w 20 0.600 6.3 17.4 350 17.6 353 Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 cell ins,1/2" 1835 0.032 30.0 0.93 1703 1.69 3100 gypsum board int fish Floors 22A-tpl:Bg floor,light dry soil,on grade depth 212 0.989 0 28.7 6080 0 0 .� wrightsoft® 2021-Nov-3011:31:28 6�m Hgtt-Sute®Uriversa12021 21.0.07 RSU24004 Page 2 1820DGL1Lot5lBIk1Waterstore1820DGL_FX43AILnQ Calc=MJ8 Frort Door faces:W i Project Summary Job: Lot51 Block Waterstone... DEL-AIR Entire House HEATING•:IIIR CGNORIOtiIHG B}/: D C S DEL AIR HTG,A/C& REFRIG.INC 531CODISCOWAY,,SANFORD,FL32771PhDnei407-333-2665.Faz:407-333-3853 WebWWW.DELAIR.COM Project • • For: ADAMSHOMES 5379 Lugo Street,Fort Pierce,FL 34951 Notes: JA8-18-15 Change to 3.0 ton 2/16/16 S.Finch RVSD 12/7/16 JA L.S. 3-23-21 VWK DesicIn Information Weather: St Lude Co Intl,FL,US Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24339 Btuh Structure 19374 Btuh Ducts 4220 Btuh Ducts 5777 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28559 Btuh Use manufacturer's data y Rate/swin multiplier 1.00 Infiltration Equipmen sensible load 25151 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3364 Btuh Ducts 1403 Btuh. Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1820 182 Equipment latent load 4767 Btuh Volume(ft3) 18350 18350 Air changes/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 29918 Btuh . Equiv.AVF(cfm) 116 61 Req.total capacity at 0.75 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HBC537AP030 Cond 25HBC537AP030 AHRI ref 204863289 Coil FX4DNF043L AHRI ref 204863289 Efficiency 8.5 HSPF Efficiency 12.5 EER,15.5 SEER Heating input Sensible cooling 26250 Btuh Heating output 34600 Btuh @ 47OF Latentcooling 8750 Btuh Temperature rise 27 OF Total cooling 35000 Btuh Actual airflow 1167 cfm Actual airflow 1167 cfm Airflowfactor 0.041 cfm/Btuh Airflowfactor 0.046 cfm/Btuh Static pressure 0.40 in H2O Static pressure 0.40 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point=36 OF Backup: Input=8 kW, Output=26788 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. t - wrightsofto 2021-Nov-3011:31:28 Right-Sdte®Uriversal 2021 21.0.07 RSU24004 Page 1 1820DGL1Lot5lBlklWaterstore182ODGL_F)(43AItnp Calc=MJ8 FrortDoorfaoes:W DEL-AIR Right-J®Worksheet Job: Lot 51 Block 1 Waterston 18... ranneo•am cormmnx�c Date: Entire House By* Dcs DEL AIR HTG,A/C&REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853-Web:W W W.DELAIR.COM 1 Room name Entire House BDRM2 2 Exposed wall 212.0 ft 36.0 ft 3 Room height 10.0 ft d 10.0 ft heat/000l 4 Room dimensions 13.0 x 13.0 ft 5 Room area 1835.0 ftz 169.0 ftz Ty Construction U-value Or HTM Area (ft') Load Area (ftz) Load number (Btuh4tz-cq (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PS Heat Cool Gross PUPS Heat Cool 6 .tN; _--i6B 19ad. __Y__ :0,049 ,_n. 1.42 259. _24 � _20 .. :28 _ _52 9 _ _ 0 Blk vell,stucco ext 0.201 n 5.83 4.06 590 534 3113 2168 100 100 583 406 2A 2ov 0230 n 957 852 7 0 66 59 0 0 0 0 0.330 n_ 9.57 852 49 0 _469_�418 0 � 0 11 ;W�_ _ i 6B-19ad_,. 0,049 Blk wall,stucco ext 0.201 a 5.83 4.06 400 317 1846 1286 130 114 663 461 I--G 10C-v 0550 a 1525 1620 18 18 285 289 0 0 0 0 2A-2ov 0230 a 957 2225 33 2 313 730 16 1 156 365 2A2oy 0.330 "e 957 852 33 _.33 313 279 _ 0 .._ 0 0 0 19ad ---, __ ;0.049 ._s.__ 1.42 52 Blk wall,stucco ext 0.201 s 5.83 4.06 660 611 3561 2481 136 130 758 528 t-G-2A_2ov -- m ------ -0.330 s 9.57 _ 852 49 49 _ 469 --418-_ _0 - 0 -- -0-------0 -- _._ 259 20,_-_--20 ----ti_?8 52-: __ _. 0 _ _.._.__0_ __._.._0. __. 0 Blk Hall,stu000 ext 0.201 w 5.83 4.06 200 129 751 523 0 0 0 0 2A-2ov 0.330 w 957 20.99 33 2 313 686 0 0 0 0 26-2N 0.330 w 957 11.58 5 5 48 58 0 0 0 0 2B-2N 0.330 w 957 13.35 13 11 128 179 0 0 0 0 11J0 0.600 w 17.40 1758 20 20 350 353 0 0 0 0 0091 _- y._ 264 131_ _270 ;. - _270 ._ - 713 354 _ C 16B-30ad __. __9 _ �0 -_ :0 _. 6 0 032_-___ W 0.93- _1,69 1835 _ _1835 _1703 3100 .. 169 169_ 157 _.___286. F 22A tpl.' - _ 0 989 _ 28.68: _0.00 -,1835 - 212__._.-6Q80 ---0. ....._._169 -36 6 c)AED excursion 0 -3 Envelope loss/gain 20635 13589 3349 2043 12 a) Infiltration 3704 1035 691 193 b) Roomventilation 0 0 0 0 13 Internal gains: Oecupantspa 230 5 1150 0 0 Appliances/other 3600 .300 Subtotal(lines 6 to 13) 24339 19374 4040 2536 Less extemalload 0 0. 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 24339 19374 4040 2536 1 15 Duct loads 17% 30% 4220 5777 17% 30% 700 756 Total room load 28559 25151 4740 3292 Air required(dm) 1167 1167 194 1, Calculations approved byACCAto meet all requirements of Manual J 8th Ed. - - wrGgF�tsoft^ Right-Sute®Uriversal 2021 21.0.07 RSU24004 2021-Nov-301 Page 18 1820DGL1Lot5lBlklWaterstorel82ODGL_FX43A]LrLp CaIc=1VJ8 FrortDoorfaces:W • DEL--AIR Right-J®Worksheet Job: Lot 51 Block 1 Waterston 18... runnxo•am cormmaMB Date: Entire House By. PCs DEL AIR HTG, A/C&REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333,2665 Fax:407-333-3853 Web:W W W.DEL IR.COM 1 Room name BATH 2 BDRM3 2 Fposed well 6D it 13.6 ft 3 Room height 10.0 ft heat/cool 10.0 It heaV000l 4 Room dimensions 13.0 x 6.0 It 13.0 x 13D It 5 Room area 78.0 ftz 169.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuht-n (BtutvYtz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W-, 16B�19ad - _ _0049_ n_ 1.4.? .._ 259_ ..:_:0 _._ 0. ..._ 0 _._ 0 v_4 v� Blk well,stucco ext 0.201 n 5.83 4.06 0 0 0 0 0 0 0 0 �C 2A 2ov 0.330 n 957 852 0 0 0 0 0 0 0 0 1- 2A 2ov_ _ _0.330 _n_ 957 852 0 _—0 0 -___ 0_ 0 _ 0_ --0 0 a---.259. 0' Blk well,stucco e)d 05 a 5. 0 0 0 0 0 0 0 0 10C-v 0550 a 15.95 95 1620620 0 0 0 0 0 0 0 0 2A-2ov 0330 a 9.57 2235 0 0 0 0 0 0 0 0 2A 2ov 0330 - e 0 b 957 852 0 __0 0 _ _.0..w,r.. _w 0 _.._,0 _•. -0 _... _. 16E 19ad.. _ :___ .. _ 0 049 s_.. 1.42 a 2.59 �_.. ._0 . _.__-0 _ 0 1�/ Blk well,stucco e:d 0201 s 5.83 4.06 60 60 350 244 130 114 663 461 -_-_G 2A 2ov_ _0330 _s_ 9,57 852 0 0 0 _ 0 __ 16_ 16 _ 156 139- W�...._ Blk wall,stucco ext 0.201 w 5.83 4.06 0 0 0 0 0 0 0 0 2A-2ov 0330 w 9.57 20.99 0 0 0 0 0 0 0 0 2B-2fv 0,330 w 9.57 11.58 0 0 0 0 0 0 0 0 2B-2fv 0.330 w 957 1335 0 0 0 0 0 0 0 0 11JO m0.600�w_ 17AO 1758 0 0 0 0 0 � 0 0 0 _. _ _ _ ._.___- -- _ -- ____ -_,. P 12C Osw -- - ._0.091. _ _2.64 ._131 _ __..:_..0 0 - __--0- a _.._ _0 . n - _< C__ 16B30ad�-m-- _-- _-__. 0.032 :-- -.-__ 0.93- 1.69 7 6 78 _ 78 72 _ 132 169 _._169 ,__ 157 _ 288 F - 22A 1...__ 0:989_.. .. _28.68 .___-._0.00 ---_ _78 ...... _6_-, 71 6 N c AEDexarsion-�.�_ - _ - - - - -- -- -- _._ -- •'- ---._. ____. - -- -_. _ . -- - -- 18 56 Fnvelope loss/gain -594 3571 1346 831 12 .a) Infiltration 115 32 249 70 b) Room ventilation 0 01 0 0 13 Internal gains: OccupantsQa 230 0 0 0 0 Appliances/other 0 300 Subtotal(lines 6 to 13) 709 389 1598 1200 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 709 389 1598 1200 15 Duct loads 17% 30% 123 116 17% 30% 277 358 Total room load 832 506 1875 1572 Air required(cfm) 34 23 77 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. - - wrightsoiFt_� � 2021-Nov-3011: e 2� RigM-Sute®Uriversal 2021 21.0.07 RSU24004 Page 2 1820DGL\Lot5lBlklWaterstonel82ODGL_FX43AItrLp CaIc=MJ8 FrortDoorfaces:W DEL-AIR .Right-JO Worksheet Job: tot51 BIoI:kI waterstone1&... rMmo'am cormmarmco En title House Date: By: DCS DEL AIR KrG,A/C&REFRIG. INC 531 CODISCO WAY SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM 1 Room name DININCvMYER DENBDRM4 2 Exposed wall 25.0 ft 31.0 ft 3 Room height 10.0 ft heat/000l 10.0 ft heat/bool 4 Room dimensions' 1.0 x 276.0 ft 13.0 x 13.0 It 5 Room area 276.0 ftz 169.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-`F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PB Heat Cool Gross N/PB Heat Cool 6 ,W 16B19ad. _ _.._0.049 _n- _ 1.42.„,.__259 0 _._0' a-._.-_._0 N% Blk vnall,stucm ext 0201 n 5B3 4.06 0 0 0 0 50 50 291 203 2A-2ov 0.330 n 957 852 0 0 0 0 0 0 0 0 2A2o_v_--- _ 0330 _n 9.57 852 0 0 0 ---- 0_.. 0 0_ _0. 0 1,42___-2.59 Blk wall,stucco ext 0.201 a 5.83 4.06 0 0 0 0 0 0 0 0 I--G 1oC-v 0550 a 15.95 1620 0 0 0 0 0 0 0 0 2A-2ov 0.330 a 957 2235 0 0 0 0 0 0 0 0 2A 2ov _. 0 330 _e 9.57 _.._ 852 0,_.__ 0 0 m__._0 ___ 0 ._ 259_ `0 0 -_....... ,0 -_---.__-0 _--""_---0 . _. 0 Vtl Blk mall,stucco ext 0.201 s 5,83 4.06 110 77 451 314 130 130 758 528 �---G 2A-2ov r 0330 ,_s _ 957 852 33 -33 313---__279_.._ 0 _ 0 _-- 0 --_-_--0 1.42 259 _0 ... _---0 -- 0 __-- Blk mall,stucco e)d 0.201 w 5B3 4.06 70 32 184 128 130 4 97 567 395 2A-2ov 0330 w 957 20.99 0 0 0 0 33 2 313 686 213-2fv 0230 " w 957 11.58 5 5 48 58 0 0 0 0 2B-2fv 0230 w 957 1325 13 11 128 179 0 0 0 0 11J0 0.600 w 17.40 1758 20 - 20 _ 350 353 _____.0 0 0 0 _ _._ _..... _.. - .__ .____ .- P.. _-- 12C Osw - _- _ _ 0,091 -- 2.64 1 31 __,70._.-_, 70 — 185-. _-- __92 __0 __.O__ _0 _ ._0 C__ 16B30ad,-____-__ _, " 0,032 ___-_ ____0,93,____1.69 276 276 __. �_256 __ _P466_ _-_ 169__ _ 169_ __157, __ 286. F .. 22A �_-_:. a 0989 . ._:__.28_68 :_A00- -. _276 25 _ .__1717 _—.__9. .. 1,69 . -_31 889 ..- _ ____ 6 c)AED excursion 236 279 Envelope loss/gain 2631 2104 2975 2377 12 a) Infiltration 345 97 595 16 0 0 0 b) Room ventilation 0 0 13 Internal gains: Oocupants@ 230 1 230 0 0 Appliances/other 0 300 Subtotal(lines 6 to 13) 2976 2431 3570 2843 Less eMemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2976 2431 3570 2843 15 Ductloads 171/6 30% 516 725 17% 30% 619 848 Total room load 3492 3156 4189 3691 Air required(cfm) 143 146 171 171 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed. -PI.F wrigFrtsoft^ 2021-Nov 3011:31:28 Right-SUte®Uriversal 2021 21.0.07 RSU24004 Page 3 1820DGLtLot5lBlklWaterstorel82ODGL_FX43AItnp Calc=MJB FrortDoorfaces:W 9 Job: Lot 51 Block 1 Waterston 18..:f DEL:AIR Right-JO Worksheet Entire House Date: By: DCS DEL AIR WIG,A/C&REFRIG. INC 531 C.ODISCO WAY SANFORD,FL 32771 Pione:407-333-2665 Fax:407-333-3853 Web:W W W.DELAIR.COM 1 Room name FAMILY RM N14TR BDRM 2 Exposed Nall 13.0 It 41.0 ft 3 Room height 10.0 It heat/cool 10.0 ft heat/cool 4 Room dimensions 13.0 x 22.0 It 14.0 x 17.0 ft 5 Room area 286.0 ft2 238.0 ftz Ty. Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/t2-9 (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (it) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W _ 16619ad:, 0.949 _259 ._20.____._.-20 : .28 -- _ _52 Blk vdl,stucco ext 0.201 n 5,83 4.06 0 0 0 0 170 154 896 624 2A-2ov 0.330 n 957 852 0 0 0 0 0 0 0 0 2A-2ov 0.330 n 957 852 0 0 0 0 16 0 ._ _ _156 r 139 2.42 2 52 0 A49 e_ _ -_ 0 Blk wall,stucco ext 0.201 a 5.83 4.06 130 79 463 323 140 124 721 502. —G 10C-v 0550 a 1525 1620 18 18 285 289 0 0 0 0 2A-2ov 0.330 a 957 2235 0 0 0 0 16 1 156 365 2A 2ov 0230 e_ 9.57 852 33 _ 33 313 279-rem 0_ �, 0 0 0 76&19ad_.�. _--- --:_._0049 s. _ 1,42: 259- - . 29 --- -20.._._:�-2- __._52 _.__ _0 Blk vnell,stucco ext 0201 s 5.83 4.06 0 0 0 0 100 100 583 406 t—G 2A 2ov _ 0.330 s,- 957 _852 0 0 _ 0 _ 0 .._ 0.__ 0_. 0 0 .166-19ad ._ 0,049 Blk vall,stucco end 0.201 w 5.83 4.06 0 0 0 0 0 0 0 0 2A-2ov 0330 w 957 2099 0 0 0 0 0 0 0 0 VN 2B-2fv 0330 w 957 11.58 0 0 0 0 0 0 0 0 2B-2fv 0.330 w 957 1325 0 0 0 0 0 0 0 0 11J0 0.600 w 17.40 1758 0 0 0 0 0 0 0 0 _-- .-_..__. _ _..._ __._ 12C-0svv..__:__ __ .___._0.091 2.64 ._ .�_ .._ _._ _ 0 Q. C--- 16B-30ad_._ - - -- - 0 032_- -0.93._..._. __.. 1.69 286__ _ 286 265 --_ 483 238 238 .221_ 402, F ., .22A-1p1'�_.;.�_. _ _.:_. _0.989 ._:_ : .28.68 _._ 0.00 _286 -13 -373 ----_0.__._ ._238_ _ 41 _ 1176 _0 77, __n t..__ ___r_ _ _ 6 c)AED exairsion -119 -130 Envelope loss/gain 1813 1462 3909 2308 12 a) Infiltration 403 113 787 220 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 3 690 1 230 Appliancesbther 300 600 Subtotal(lines 6 to 13) 2216 2564 4696 3358 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2216 2564 4696 3358 15 Duct oads 17% 30% 384 765 17% 30% 814 1001 Total room load 2600 3329 5510 4359 Air required(dm) 106 154 225 202 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. fI.F wr➢gf�tsoR- R ght-Sute®Uriversa12021 21.0.07 RSU24004 2021-Nov-3011:31:28Page 4 1820DGL\Lot5lBlklWaterstoml82ODGL_F)(43AItrLp CaIc=MJ8 FrontDoorfaces:W _ DEL-AIR Right-M Worksheet Job: Lot51 Block Waterstone18...; Entilie House Date: By- DCS DEL AIR HTG,A/C&REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM 1 Room name M BATH M WIC 3 Room h wall 0 eight 10.0 ft 120 1t heaUcool 10.0 ft It 4 Room dimensions 1.0 x 119.0 ft 7.0 x 7.0 It 5 Room area 119.0 ftz 49.0 ft2 Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-`F) (BtuhRtz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross- N/PiS Heat Cool Gross N/PiS Heat Cool 6 _W_._. 16B 19ad_w. -0049 . n -1,42, _ 259 _..0 .._ 9 0 --.._.- 0 .--:_0.._ 0 V)! Blk v�dl,stucco ext 0.201 n 5.83 4.06 120 113 659 459 0 0 0 -� +0 2A-2ov 0.330 n 9.57 852 7 0 66 59 0 0 0 0 -- 2A-2ov_ . -- --0.330 ._n__ -_957 -852 0 .� 0 0 00 --e- __._ 1_.42 259 _. 0 _ _ _ 0 Blk vdl,stucco ext 0.201 a 5,83 4.05 0 --0 0 0 0 0 0 0 10C-v 0550 a 15.95 1620 0 0 .0 0 0 0 0 0 2A-2ov 0230 a 957 2235 0 0 0 0 0 0 0 0 2A 2ov ..__ 0,330 e_ 957 _,852 0 _ 0 _..- ,0 __ 0 .,_ ._ 0 0 0 0 166 19ad _ Q,_p _s-- _ 1.42 --2,59- -- .0 �. 0 e' s 0 0 ,.._-t-°__0__ .__w_0 Blk Hell,stucco ext 0.201 s 5.83 4.06 0 0 0 0 0 0 0 0 2A-2ov_ _ _ _ 0.330 _s--.--i_957___852 0_ 0 _re 0 _ _._.0.__.... _0.. _ _ 0 ._ 0 _-Q - -- -- W __ 19ad� - _: Q049 ._w _ _1.42. _259 _ 0 0 0 0 0 ._ ,0 __Q _ 0 Blk%dI,stuccoext 0.201 w 5.83 4.06 _ 0 ._ 0 0 .__. _ .0 - - 0 - -0 - 0 -- 0 2A-2ov 0.330 w 957 2029 0 0 0 0 0 0 0 0 213-2fv 0230 w 957 11.58 0 0 0 0 0 0 0 0 2B-2fv 0230 w 957 13.35 0 0 0 0 0, 0 0 0 _ 11J0 0.600 w 17AO 1758 0 0 0 0 0 0 0 0 31, 0.__. 9 - 16B-30ad T - _0.932 _ _. _ _ 0.93 _.... 1.69 _... _119 _. 119 . 110 201 --49 -- 49 _ 45 83 0.989---•_-----28.68 -- 0.00 119.i _ _..12 .344 -0-- - - ----49 - --9 6 c)AED exairsion _35 -4 Envelope lossrgain 1180 684 45 79 12 a) Infiltration 230 64 0 0 b) Room ventilation 0 0 0 0 13 Internal gains. Occupants@ 230 0 0 0 0 Applianoes/other 0 0 Subtotal(lines6 to 13) 1410 749 45 79 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1410 749 45 79 15 Ductloads 17% 30% 245 223 17% 30% 8 24 Total room load 1655 972 53 103 Air required(cfm) 68 4512 5 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -f� wrigtitsoR- 2021-Nov-3011:31:28 Right-SLite@)Universal 2021 21.0.07 RSU24004 Page s 1820DGL\Lot5lBlklWaterstorel82ODGL-F)(43AItrLp Ca1c=MJ8 FrortDoorfaces:W DEL--AIR Right-J®Worksheet Job: Lot 51 Block 1 Waterston 18... • . Entire House Date: By: DCS DEL AIR WIG,A/C&REFRIG. INC 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2865 Fax:407-333-3853 Web:WWW.DELAIR.COM 1 Room name KITCHENNOOK LAUNDRY 2 E posed wall 29.0 ft 6.0 ft 3 Room height 10.0 ft heaV000l 10.0 ft heaU000l 4 Room dimensions 1.0 x 246.0 ft- 6.0 x 6.0 ft 5 Room area 246.0 ftz 36.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz (Btuh/ftz) or perimeter (ft) (Btuh) or. perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PiS Heat Cool 6 .- _. 16B19ad _r_ ___ _ 0- --n. - _1,42. 259 --; -- .Q0__'__8^__ __0___ _ _0 _____0,_,- _0 Blk yell,stucco ext 0.201 n 5,83 4.06 150 117 684 476 0 0 0 0 2A-2ov 0.330 n 957 852 0 0 0 0 0 0 0 0 ---- 2A-2ov .. -.- -- - 0.330---n - 9.57-_852 - - 33 -0 - - 313- -279 - -0._. �0 _ 0._ 0 16_B 19ad ..� -_ __0.049-_e-- 1.42__. 259_ 0 --___ 0 --- 1 O v�ell,stucco ext 055 a 5.95 620 0 0 0 0 0 0 0 0 10C-v 0550 a 15.95 1620 0 0 0 0 0 0 0 0 2A-2ov 0.330 a 957 2225 0 0 0 0 0 0 0 0 2A 2ov _ _ 0.330 _ e 957, 852 0 0 _ 0 0 ._u. _. 0 _ 0.. _0 0 �-_3:`___._8. Val Blk%all,stucco ext 0.201 s 5.83 4.06 0 0 0 0 0 0 0 0 _ 2A 2ov -_ _0.330 _s _ 9.57 852 _0 0 _. ..__._0 ___ 0 --_-0----__ ,0._ 0_ 0 0A 9 w 1.42_e._259 .,_ -.---__o.--- -.0 .w_.:____o -- �. .. -- 4_ ___o. - Blk mall,stucco ext 0.201 w 5B3 4.06 0 0 0 0 0 6 0 0 2A-2ov 0230 w 957 20.99 0 0 0 0 0 0 0 0 213-2fv 0.330 w 957 11.58 0 0 0 0 0 0 0 0 213-2fv 0230 w 957 13.35 0 0 0 0 0 0 0 0 11J0 0.600 w 17.40 1758 0 0 0 0 0_ 0 0 0 - _------__,._ _.. .. ...__. _-- --- _ .__ ..___ P __ 12C-Osw_------ _ -0.091 _. 2.64 a 131, __ 140 _ ._ 140 . _-.--369 - .183 . _ 60 _ _60 -- ---158_ ---.79 C-__. 16B-30ad.____...__ _____0.032 --`- ,--__- .____1.69 _____246 __ 246. 228---- 416.---__36__-_ _36 _33. . __.__61_ F---_-- 22A. L.__ �v _ � _---- - --_-0989..__- _ .28.68 '-----0_.00 - ----246 _29_ 832------ 0 -----36 ----6 :._.,172 --- - _0. ------------- 6 c)AED excursion -117 -33 Envelope loss/gain 2426 1237 364 107 12 a) Infiltration 288 80 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants(_ 230. 0 0 0 0 Appliances(other 1200 600 Subtotal(lines 6 to 13) 2714 2518 364 707 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2714 2518 364 707 15 Duct loads 17% 30% 471 751 171/6 30% 63 211 Total room load 3185 3268 427 9A17 Air required(cfm) 130 152 17 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. Aft - - wrigf�tsoTt- 2021-Nov-3011:31:28 k Right-Sute®Uriversal 2021 21.0.07 RSU24004 Page 6 1820DGL\Lot51BIk1Waterstone1820DGL-FX43AItnp Calc=MJ8 FrortDoor faces:W a Job: Lot191 Block Waterston... ��j Duct System Summary DEL-AIR Date: " LHEffiH(;-:=C°"°!°°MG Entire House By: DCs DEL AIR HTG,A/C& REFRIG. INC 531 CODISCO WAY,SANFORD,FL32771 Phore:407-333-2665 Fax:407-333-3853 Web:WWW.DELAIR.COM Project • • For: ADAMS HOMES 5379 Lugo Street,Fort Pierce,FL 34951 Heating Cooling External static pressure 0.40 in H2O 0.40 in H2O Pressure losses 0.06 in H2O 0.06 in H2O Available static pressure 0.34 in H2O 0.34 in H2O Supply/return available pressure 0.170/0.170 in H2O 0.170/0.170 in H2O Lowest fricti on rate 0.300 in/100ft 0.300 in/100ft Actual air flow 1167 cfm 1167 cfm Total effective length(TEL) 113 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (Cfm) FIR (in) (in) Mat Ln(ft) Ln(ft) Trunk BATH 2 h 832 34 23 0.394 4.0 Ox 0 VI Fx 16.3 70.0 BDRM2 h 4740 194 153 0.366 8.0 Ox 0 VIFx 22.9 70.0 BDRM3 h 1875 77 72 0.433 6.0 Ox0 VIFx 8.6 70.0 DENODRM4 c 3691 171 171 0.409 7.0 Ox0 VIFx 13.2 70.0 DINING/FOYER c 3156 143 146 0.444 7.0 Ox 0 VIFx 6.5 70.0 FAMILYRM c 3329 106 154 0.330 8.0 Ox 0 VIFx 17.9 85.0 sti KITCHENMOOK C 3268 130 152 0.323 8.0 Ox 0 VIFx 20.1 85.0 st1 LAUNDRY C 917 17 43 0.316 4.0 Ox 0 MR 22.7 85.0 st1 M.BATH h 1655 68 45 0.317 5.0 Ox 0 MR 22.2 85.0 st1 M.WIc C 103 2 5 0.318 4.0 Ox0 VIFx 21.9 85.0 sti MSTR BDRM h 5510 225 202 0.300 8.0 Ox 0 VI Fx 28.2 85.0 sti Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st1 PeakAVF 549 601 0.300 562 14.0 0 x 0 VinIFIX -�- wrightsoft' 2021-Nov-3011:31:29 ..,,..•�.M1, _- gym.. 9ght-Sute®Uriversal2021 21.0.07 RSU24004 Page 1 1820DGL1Lot5lBlklWaterstore1820DGL_FX43AIt.rLp Calc=MJ8 FrortDoorfaces:W Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Mat Trunk rbi Ox 0 1167 1167 0 0 0 0 Ox 0 VIFx - wrightsoft 2021-Nov-3011:3129 quJh•/x 6M1u.wN�q[mµry Right-SdIe®Udversal 2021 21.0.07 RSU24004 Page 2 ACCK 1820DGLIot5lBlklWaterstore182ODGL_FX43AIt.rLp Calc=MJB FrortDoortaces:W U 0 vuxrm mac ® vLANA BEDROOM Y7 012 12 rag 1a lwcd 5' bath duct tcN ° mm 1B r to roof cap .U ♦I N 14xB200d ,,,. w/ standard 70 oa. 1 x\ ♦ 0• r'a�o cfm bath fan g ` O � 6x16 ra IBA6 rag 5" bath duct asua loved Z 3 � O O t0 fOOf Cap e• FAMILY ROOM 14x14 r B. 2 � w/ standard 70 p� rC maa cfm bath fan ® Icd 8xd" d axe 155 a 5 _ g A 10x1 g B �c r-C 451.aA 10x61wctl Sd � 5' 14' 6• 70 m 1a (D [� Aae U r CLG pti ' aAsr } 9• 2401 for g Z m 42X42 A/C SLAB 148 lwad DINING ROOM O BY BLDR MIN A 150 x 7• .ax0 Wag , 2' FROM WALL y N 121 iw5d w LU 1202 rag11 0 a dryer aaot II I �' %4 o roof cap w/dryer vent box O F,Q_yE@ 1 12 og w mac A BEDROOM @d 2 OAR GARAGE :a �g 12x6 loved e'maro R 170ULJ Z (n O IV�mumr W (•— uc or ou.a oaa X — U) . _b a L1 O LL NOTE TO BUILDER:MUST PROVIDE UNRESTRICTED U. Q 1 INCH UNDERCUT BELOW DOORS TO HABITABLE ROOMS N O Tronsler tlaata/grma eked m oo pnanae QQ o IM I with Florida Residential Building Cada-M1602.4 (V m e.,aweaosox r balanced return air. AREA CALCULATIONS Q ao' O CV } EXCEPTIONS 1-3 r•r naM rem v. — 0— m 3.0 TON W/5KW 0240V 1PH roru urao(u0 iem v. LU •• > Z SBox17 len my to 1/4•=1'0• / co—rom p�wso J Z (] W platform by FLOOR PLAN ~ m F Q n.an o>'v. O J O'7 Q. M bid, Aura EL VATI rom ems uxaa agar ,•w v. ALL ELEVATIONS "i N 0 in Rating Must have a minimum clearance of 4 inches around the air handler per the Stale Energy code. All duct has an r=6 insulation value.