Loading...
HomeMy WebLinkAboutNOA - ROOF UNDERLAYMENTSENGINEER EVALUATE Soprema, Inc. 1640 rue Haggerty Drummondville, Qu6bec J2C 5P8 Canada (819)478-2400 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 TEST CONSULT Evaluation Report S18010.06.09-R19 FL2569-R21 Date of Issuance: 06/15/2009 Revision 19: 12/16/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7" Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. s The facsimile seal appearing was authorized by Robert '�.� _'naY.r '>=� Florida Registration No. 59166, Florida DCA ANE1983 `. Nieminen, P.E. on 12/16/2020. This does not serve as 9 "''+ »_„ '•"' an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC ONEMOjetc. PRODUCT4. Material Product Plant(s) Description Standard 4.1 Lastobond TU HT ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric FRSA/TRI 09-18 surfaced, SBS modified bitumen roof underlayment 4.2 Tri-Built S/A HT TU ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric Underlayment FRSA/TRI 09-18 surfaced, SBS modified bitumen roof underlayment 4.3 Lastobond Shield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch 4.4 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS 40 modified bitumen roof underlayment 4.5 Lastobond Shield HT ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment 4.6 Lastobond Pro HT-N ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch 4.7 Lastobond Pro HT-S ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment 4.8 EnviroShield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment 4.9 Lastobond 195 ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand - Wadsworth, OH surfaced, SBS modified bitumen roof underlayment 4.10 Lastobond Eaves ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand - Protection Sheet Wadsworth, OH surfaced, SBS modified bitumen roof underlayment 4.11 Lastobond Eco ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment 4.12 Lastobond Smooth Seal ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film - HT Wadsworth, OH surfaced, SBS modified bitumen roof underlayment 4.13 Tri-Built Smooth HT S/A ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film- Underlayment Wadsworth, OH surfaced, SBS modified bitumen roof underlayment 4.14 PrimeSource Grip -Rite ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film - Smooth Seal HT Wadsworth, OH surfaced, SBS modified bitumen roof underlayment 4.15 RESISTO LB1236 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment 4.16 TRI-BUILT Sand-R SA ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand - Shingle Underlayment Gulfport, MS surfaced, SBS modified bitumen roof Wadsworth, OH underlayment NEMO ETC, LLC Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Soprema Roof Underlayments Evaluation Report 518010.06.09-1119 FL2569-R21 Revision 19: 12/15/2020 Page 3 of 9 ONEMOletc. TABLE 1: ROOF COVER OPTIONS FBC Section: 1507.2 1507.3 1507.4 & 1507.5 1507.7 1507.8 & 1507.9 Clay and Concrete Tile Metal Slate or Asphalt Wood Shakes or Mechanical Adhesive- Panels Shingles Underlayment Shingles Slate -Type Shingles Attach Set Shingles Lastobond ECO, RESISTO LB1236, TRI- BUILT Sand-R SA Shingle Underlayment, Yes Grip -Rite Eave & Valley Protector, Yes No No No No Yes (joint strips, 1507.1.1.3/ TopShield ICE & WATER DEFENDER, R905.1.1.3) RESISTO LB1244 Lastobond Smooth Seal HT, Tri-Built Yes Smooth HT S/A Underlayment, Grip -Rite Yes No No Yes Yes Yes (joint strips, 1507.1.1.3/ Smooth Seal HT R905.1.1.3) Yes ColpheneFIR GR Yes Yes No No No Yes (joint strips,1507.1.1.3/ R905.1.1.3) 5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment / tile -adhesive combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS' Underlayment Adhesive Florida Product Approval Lastobond TU HT, Tri-Built S/A HT TU Underlayment Dupont "Tile Bond'" Roof Tile Adhesive" FL22525 ICP Adhesives and Sealants "Polyset° AH-160" FL6332 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Material(s) Lastobond Shield, Lastobond Pro (Optional) ASTM plywood, OSB or Southern Yellow Pine HT-N, RESISTO SA SMOOTH PLY Deck / D41, Elastocol Stick, (SYP) 40, Lastobond Shield HT, sheathing Elastocol Stick Zero ASTM D41 structural concrete Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, (Optional) Elastocol Dens Deck Prime or SECUROCK Gypsum- Tri-Built S/A HT TU Insulation Stick Zero Fiber Roof Board Underlayment, Lastobond Eaves Protection Sheet, Lastobond 195, self- Lastobond ECO, RESISTO LB1236, adhering TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & Base Sheet (Optional) Elastocol ASTM D226, Type II felt or Modified Sopra- WATER DEFENDER, RESISTO Stick Zero G LB1244, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT Deck / (Optional) ASTM Plywood D41 sheathing ASTM D41 structural concrete Col hene FIR GR p self- adhering Insulation (Optional) Elastocol Dens Deck Prime or SECUROCK Gypsum - Stick Zero Fiber Roof Board (Optional) Elastocol ASTM D226, Type II felt or Modified Sopra- Base Sheet Stick Zero G 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report S18010.06.09-R19 Certificate of Authorization #32455 7TR EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R21 Soprema Roof Underlayments Revision 19: 12/15/2020 Page 5 of 9 ONEMOletc. 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 10-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Max. 10-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high on slope, as shown below) 6.12 r Lastobond TU HT, Tri- Built S/A HT TU Underlayment Lugged n Flat Max. 10-tile stack 5:12 Colphene FR GR Lugged Max. 10-tile stack 6:12 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.2.1 Installation of RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO 1_61236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 6.3 Lastobond TU HT, Tri-Built S/A HT TU Underlayment, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip -Rite Smooth Seal HT, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244 or Colphene FIR GR: 6.3.1 Non -Tile ADDlications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. NEMO ETC, LLC Evaluation Report S18010.06.09-R19 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R21 Soprema Roof Underlayments Revision 19: 12/15/2020 Page 8 of 9