HomeMy WebLinkAboutGA Southern Plans - engineeringWINDOW AND DOOR NOTE EXTERIOR WINDOWS AND GLASS DOORS SHALL BE TESTED BY AN APPROVED INDEPENDENT TESTING LABORATORY, AND BEAR AN AAMA OR WDMA OR OTHER APPROVED LABEL INDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT EVALUATION ENTITY TO INDICATE COMPLIANCE WITH THE REQUIREMENTS OF THE FOLLOWING SPECIFICATION. ANSI/AAMA/NWWDA 101/1S 2/97 THE CONSTRUCTION SHALL BE TESTED IN ACCORDANCE WITH ASTM E 330, STANDARD TEST METHODS FOR STRUCTURAL PERFORMANCE OF EXTERIOR WINDOWS, CURTAIN WALLS, AND DOORS BY UNIFORM STATIC AIR PRESSURE. GENERAL NOTES: 1. ALL STEEL SHALL BE 50 KSI STEEL. 2. FASTEN METAL ROOF AND WALL PANELS TO FRAMING WITH 1/4" X 3/4" SELF DRILLING FASTENERS WITH CONTROL SEAL WASHER @ 4" O.C. AVERAGE. 3. ALL FIELD CONNECTIONS SHALL BE 1/4" X 3/4" SELF DRILLING SCREWS. 4. ALL SHOP CONNECTIONS SHALL BE WELDED. 5. CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TITE MODEL AT 1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVELENT. GROUND ANCHOR REQUIREMENTS ARE 1@ EACH 6. POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS. CORNER & ONE EVERY INTERIOR RAFTER POST LOCATION. AT A MAXIMUM 4'-0" O.C., AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING AND/OR CONCRETE SLAB CONSTRUCTION. DESIGN WAS DONE IN ACCORDANCE WITH THE 2020 FLORIDA BUILDING CODE 7TH ED. (FBC) WITH 2012 SUPPLEMENT AMENDMENTS 2006 INTERNATIONAL BUILDING CODE (IBC), 2009 IBC AND 2012 IBC.AGAINST HUMAN ERROR. THE CONTRACTOR IS ULTIMATELY RESPONSIBLE TO VERIFY DIMENSIONS AND OTHER DETAILS ON THE PLANSWHILE EVERY ATTEMPT HAS BEEN MADE IN THE PREPARATION OF THESE PLANS TO AVOID MISTAKES, THE DESIGNER CANNOT GUARANTEEAND NOTIFY DESIGNER OF ANY ERRORS OR OMISSIONS BEFORE STARTING CONSTRUCTION.OF SHEETDRAWING NO.NOTE:1 5E03061-20Engineering Services Providedby Kent M. Bice, P.E.1552 6th Street S.E. - Winter Haven, FL 33880Phone: (863) 875-5602 - Fax: (863) 508-6496www.BBDEngineering.comDESIGN FIRM, LLC&BBD ENGINEERINGGA SOUTHERN STEEL BUILDINGS INC.Drafting Services Provided By:CAPE CORAL, FL 339091122 AMBER LAKE CT.VALKYRIE DRAFTING SERVICESSCHEMATIC DESIGN ELEMENTS FOR THIS PROJECT WERE PROVIDED TOBBD ENGINEERING & DESIGN FIRM, LLC & DRAFTING DESIGN SERVICE, INC.,BY: USA QUALITY STEEL STRUCTURES, LLC.ClientLocationPREFABRICATED UTILITY STRUCTURE:3 3 3 3 2 2 1 1 2 2 2 2 FOR SITE SPECIFIC PLANS ONLY 3'-0" (TYP) INSTALLATION NOTES AND SPECIFICATIONS HELIX ANCHOR NOTES: 1. FOR VERY DENSE AND / OR CEMENTED SANDS, COARSE GRAVEL AND COBBLES, CALICHE, PRELOADED SILTS AND CLAYS, USE MINIMUM (2) 4" HELICES WITH MINIMUM 30" EMBEDMENT OR SINGLE 6" HELIX WITH MINIMUM 50" EMBEDMENT. 2. FOR CORAL USE MINIMUM (2) 4" HELICES WITH MINIMUM 30" EMBEDMENT OR SINGLE 6" HELIX WITH MINIMUM 50" EMBEDMENT. 3. FOR MEDIUM DENSE COARSE SANDS, SANDY GRAVELS, VERY STIFF SILTS, AND CLAYS USE MINIMUM (2) 4" HELICES WITH MINIMUM 30" EMBEDMENT OR SINGLE 6" HELIX WITH MINIMUM 50" EMBEDMENT. 4. FOR LOOSE TO MEDIUM DENSE SANDS, FIRM TO STIFF CLAYS AND SILTS ALLUVIAL FILL, USE MINIMUM (2) 6" HELICES WITH MINIMUM 50" EMBEDMENT. 5. FOR VERY LOOSE TO MEDIUM DENSE SANDS FIRM TO STIFFER CLAYS AND SILTS, ALLUVIAL FILL US MINIMUM (2) 8" HELICES WITH MINIMUM 60" EMBEDMENT. 1. DESIGN IS FOR MAXIMUM 50'-0" WIDE X 20'-0" EAVE HEIGHT UTILITY STRUCTURES. 2. DESIGN WAS DONE IN ACCORDANCE WITH THE 2020 FLORIDA BUILDING CODE (FBC) 7TH EDITION. 3. DESIGN LOADS ARE AS FOLLOWS: A) DEAD LOAD = 15 PSF B) LIVE LOAD = 12 PSF C) GROUND SNOW LOAD = 35 PSF (24'-0" WITH U-CHANNEL RAFTER TIE) 4. ULTIMATE WIND SPEED 180 MPH (NOMINAL WIND SPEED 140 MPH) MAXIMUM RAFTER / POST AND END POST SPACING = 4'-0" (UNLESS NOTED OTHERWISE). 5. RISK CATEGORY: I 6. WIND EXPOSURE CATEGORY: B 7. SPECIFICATIONS APPLICABLE TO 26 GAUGE METAL PANELS FASTENED DIRECTLY TO 5" x5"x5/16" TUBE STEEL (TS) (UNLESS NOTED OTHERWISE). 8. AVERAGE FASTENER SPACING ON-CENTERS ALONG RAFTERS OR HAT CHANNELS, AND COLUMNS (INTERIOR OR END) = 6" O.C. (MAX). 9. FASTENERS CONSIST OF 14" X 3 4" SELF DRILLING FASTENER (SDF), USE CONTROL SEAL WASHER WITH EXTERIOR FASTENERS SPECIFICATIONS APPLICABLE ONLY FOR MEAN ROOF HEIGHT OF 20'-0" OR LESS, AND ROOF SLOPES OF 14° (3:12 PITCH) OR LESS SPACING REQUIREMENTS FOR OTHER ROOF HEIGHTS AND / OR SLOPES MAY VARY. 10. WIND FORCES GOVERN OVER SEISMIC FORCES SEISMIC PARAMETERS ANALYZED ARE: SOIL SITE CLASS = D RISK CATEGORY I/II/III R= 3.25 IC=1.0 SDS = TBD V = CSW SDI = TBD PRODUCT APPROVAL: 1 APPROVAL CODE 14024.1 APPROVAL CODE 14024.1 ROOF PANEL WALL PANEL NOTE: PRODUCT APPROVAL CODES PROVIDED BY OTHERS FRAMING MEMBER NOTES: 1. ROOF RAFTERS TO BE 2 1/2"x2 1/2""x3/16" 14GA TUBE STEEL (MIN.) 2. KICKERS TO MATCH ROOF RAFTER 3. FASTEN RAFTER TO COLUMN W/ 1/2" THRU-BOLT 4. FASTEN KICKER TO RAFTER/COLUMN W/ 1/2" THRU-BOLT 5. COLUMN TO BE 2 1/2"x2 1/2"x1/4" 14GA TUBE STEEL (MIN.) 6. BASE-RAIL TO MATCH COLUMN 7. COLUMN TO BE WELDED TO BASE-RAIL 8. GROUND ANCHOR SIZE TO BE 1/2"x36" EMBEDMENT (MIN.) 2 APPROVAL CODE 17996.3ELIXIR DOOR3 APPROVAL CODE FL1074.2ASTA FL4 APPROVAL CODE 993.7KINRO WINDOW5 APPROVAL CODE 14024.129GA PANELS6 APPROVAL CODE 31737.1B LAP SIDING7 Engineer: Kent Bice FL License #: 50421 COA# 30468 02/01/21 WIND PRESSURES ZONE DESIGN PRESSURE (PSF) POSITIVE NEGATIVE 1 25.7 -64.6 2e 25.7 -64.6 2n 25.7 -79.0 2r 25.7 -79.0 3e 25.7 -79.0 3r 25.7 -91.4 4 36.7 -40.0 5 36.7 -48.0 BY: USA QUALITY STEEL STRUCTURES, LLC.SIDE ELEVATION NOT TO SCALE NOT TO SCALE TYPICAL SIDE WALLS BBD ENGINEERING & DESIGN FIRM, LLC & DRAFTING DESIGN SERVICE, INC.,SCHEMATIC DESIGN ELEMENTS FOR THIS PROJECT WERE PROVIDED TO1552 6th Street S.E. - Winter Haven, FL 33880Phone: (863) 875-5602 - Fax: (863) 508-6496www.BBDEngineering.comEngineering Services Providedby Kent M. Bice, P.E.52 NOTE:DRAWING NO.SHEET OF AND NOTIFY DESIGNER OF ANY ERRORS OR OMISSIONS BEFORE STARTING CONSTRUCTION.WHILE EVERY ATTEMPT HAS BEEN MADE IN THE PREPARATION OF THESE PLANS TO AVOID MISTAKES, THE DESIGNER CANNOT GUARANTEEAGAINST HUMAN ERROR. THE CONTRACTOR IS ULTIMATELY RESPONSIBLE TO VERIFY DIMENSIONS AND OTHER DETAILS ON THE PLANSDESIGN FIRM, LLC&BBD ENGINEERINGE03061-20PREFABRICATED UTILITY STRUCTURE:10'-0"Drafting Services Provided By:CAPE CORAL, FL 339091122 AMBER LAKE CT.VALKYRIE DRAFTING SERVICES(SEE TABLE 1 FOR FASTENER SPACING) SEAL WASHER END POST WITH 1/4" X 3/4" SDF'S W/CONTROL SECURE WALL PANELS TO RAFTER/BOW AND NOT TO SCALE TYPICAL END WALLS 3 3 SEE TABLE 1 SHEET 1 29 GA. AG PANEL METAL DECK OPTIONAL 26 GA. R-PANEL SIDE OR END PANELS VARIES 6" TS PEAK BRACE 12 3 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS 2 1/2"x2 1/2"x1/4" DOUBLE TS COLUMN 2 1/2"x2 1/2"x1/4" DOUBLE BASE RAIL 26 GA. GALVANIZED METAL SIDE PANELS. 6 310 3 20'-0" COLUMN HEIGHTClientLocation50'-0" RAFTER SPAN GA SOUTHERN STEEL BUILDINGS INC.VARIES 6" SEE TABLE 1 SHEET 1 SEE TABLE 1 SHEET 1 SEE TABLE 1 SHEET 1 SEE TABLE 1 SHEET 1 NOT TO SCALE TYPICAL BOW SECTION 12 3 2 1/2"x2 1/2"x1/4" DOUBLE TS COLUMN 2 1/2"x2 1/2"x1/4" DOUBLE BASE RAIL20'-0" COLUMN HEIGHT50'-0" RAFTER SPAN 2 3 29 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS 3 3 GROUND ANCHORS @ EACH END BOW POST AND EVERY OTHER INTERIOR BOW POST LOCATION (SEE DETAIL 4 SHEET 3) TYP END ELEVATION NOT TO SCALE TYP SIDE ELEVATION NOT TO SCALE 6" FLOOD VENT AS APPLICABLE ROLL UP DOOR (AS APPLICABLE) SWING DOOR (AS APPLICABLE) NOT TO SCALE TYPICAL HORSE BAR SECTION MAIN STRUCTURE STANDARD LEAN-TO OPTION 16 GA. U-CHANNEL BRACE FASTENED RAFTER, POSITIONED AT 45° W/ 2-1/4"x1" SDF'S AT EACH END (4 PER BRACE) STANDARD LEAN-TO OPTION OPTION FOR FREESTANDING LEAN TO SPAN UP TO 24'-0"Engineer: Kent Bice FL License #: 50421 COA# 30468 02/01/21 3/16 3/16 COLUMN TO BASE RAIL TS CONTINUOUS BASE RAIL - SIZE TO MATCH COLUMN 3 SCALE: NTS POST/BASE RAIL CONN. DETAIL BY: USA QUALITY STEEL STRUCTURES, LLC.AGAINST HUMAN ERROR. THE CONTRACTOR IS ULTIMATELY RESPONSIBLE TO VERIFY DIMENSIONS AND OTHER DETAILS ON THE PLANSWHILE EVERY ATTEMPT HAS BEEN MADE IN THE PREPARATION OF THESE PLANS TO AVOID MISTAKES, THE DESIGNER CANNOT GUARANTEEAND NOTIFY DESIGNER OF ANY ERRORS OR OMISSIONS BEFORE STARTING CONSTRUCTION.OF SHEETDRAWING NO.NOTE:3 5Engineering Services Providedby Kent M. Bice, P.E.1552 6th Street S.E. - Winter Haven, FL 33880Phone: (863) 875-5602 - Fax: (863) 508-6496www.BBDEngineering.comSCHEMATIC DESIGN ELEMENTS FOR THIS PROJECT WERE PROVIDED TOBBD ENGINEERING & DESIGN FIRM, LLC & DRAFTING DESIGN SERVICE, INC.,DESIGN FIRM, LLC&BBD ENGINEERINGE03061-20PREFABRICATED UTILITY STRUCTURE:Drafting Services Provided By:CAPE CORAL, FL 339091122 AMBER LAKE CT.VALKYRIE DRAFTING SERVICES9 SCALE: NTS END COLUMN/RAFTER CONN. DETAIL THE OPENING. CLIP POST TO RAIL ONLY ON SIDE OPPOSITE POST SHOULD BE FLUSH WITH RAIL END. NOTE: AT ROLL-UP DOOR OPENINGS, BOTTOM AND 2 ON SIDE. CHORD/RAIL WITH 1/4" X 3/4" SDF'S 2 ON SECURE TO POST (EACH SIDE) AND RAFTER 2" X 2" X 2" 16 GA. ANGLE CLIP CHORD. OR NON-STRUCTURAL HEADER TS END POST OR DOOR/ WINDOW FRAME POST. TS BASE/WINDOWS RAIL OR NON-STRUCTURAL HEADER 6 SCALE: NTS STRUCTURAL HEADER CONN. DETAIL POST TO RAIL, TRUSS CHORD, OR 4 SCALE: NTS COLUMN/BASE RAIL CONN. DETAIL EACH END (4 PER BRACE) W/ 2-1/4" X 1" SDF's AT RAFTER, POSITIONED @ 45° FASTENED TO THE POST AND 16 GA. U-CHANNEL BRACE SCALE: NTS BRACE SECTION2"2 1/4"x2 1/4"x5/16" TS ROOF RAFTER 6" TS PEAK BRACE PEAK BRACE CONN. DETAIL SCALE: NTS 10 2" X 2" X 2" 14 GA. ANGLE CLIP SECURE TO COLUMN AND RAFTER WITH (4) SDF'S 2 1/4"x2 1/4"x1/4" TS END COLUMN 3/16 3/16 CONNECTOR SLEEVE TO HEADER MINIMUM 6" LONG. MINIMUM 14 GA. CONNECTOR SLEEVE. SECURE WITH (4) SDF'S 2 1/4"x2 1/4"x1/4" DOUBLE TS END COLUMN 3-12 3-12 DOUBLE TS HEADER TS HEADER OR WINDOW RAIL 2" X 2" 2" 14 GA. ANGLE CLIP SECURE TO COLUMN AND EITHER TOP OF HEADER, OR BOTTOM OF WINDOW RAIL WITH (4) SDF'S 2 1/4"x2 1/4"x1/4" TS COLUMN OR END COLUMN DOUBLE TS HEADER 2" X 2" 14 GA. ANGLE CLIP SECURE TO COLUMN AND EITHER TOP OF HEADER, OR BOTTOM OF WINDOW RAIL WITH (4) SDF'S 2 1/4"x2 1/4"x1/4" TS COLUMN OR END COLUMN 3-12 3-12 3/16 3/16 CONNECTOR SLEEVE TO HEADER MINIMUM 6" LONG. MINIMUM 14 GA. CONNECTOR SLEEVE. SECURE WITH (4) SDF'S 2 1/4"x2 1/4"x1/4" TS DOUBLE END COLUMN 3-12 3-12 DOUBLE TS HEADER CONN. DETAIL SCALE: NTS 5 COLUMN OR WINDOW RAIL TO POST CONN. DETAIL SCALE: NTS 5A COLUMN OR WINDOW RAIL TO POST 7 SCALE: NTS HEADER/COLUMN CONN. DETAIL HEADER/COLUMN CONN. DETAIL SCALE: NTS 8 5-1/8" FOR 5/16" FRAMING Clark SmithMiami, FLGA SOUTHERN STEEL BUILDINGS INC.3/16 3/16 2" X 2" X 2" 14 GA. CLIP ANGLE SECURE TO RAFTER COLUMN AND BASE RAIL WITH (4) SDF'S MINIMUM 6" LONG. MINIMUM 14 GA. CONNECTOR SLEEVE SECURE WITH (4) SDF'S 2 1/4"x2 1/4"x1/4" TS DOUBLE POST TS CONTINUOUS BASE RAIL - SIZE TO MATCH COLUMN Engineer: Kent Bice FL License #: 50421 COA# 30468 02/01/21 2 SCALE: NTS POST DETAIL BOX EAVE RAFTER/CORNER 6" NIPPLE TO RAFTER 3/16 3/16 2 1/4"x2 1/4"x5/16" TS RAFTER 6" LONG TS 12 GA. NIPPLE SECURE POST TO NIPPLE WITH 4 1/4" X 1 3/4" SDF's. 3"x3"x1/4" TS RAFTER POST NON-STRUCTURAL HEADER, WINDOW RAIL, OR GIRT TO POST CONN. DETAIL SCALE: NTS 11 TS POST 2" X 2" X 2" 16 GA. ANGLE CLIP SECURE TO POST AND TOP OF HEADER WITH 1/4" X 3/4" SDF's. TS STRUCTURAL HEADER (NOTE: PLACE (1) @ CENTER OF DOOR HEADER.) CONCRETE BASE RAIL ANCHORAGE SCALE: NTS 1 16" 3.5" 1.5" 12" NOTE: WELL COMPACTED EARTH FILL 95% PROCTOR 6 MIL PLASTIC MEMBRANE 6 X 6 X #10 W.W. MESH REINF. OR MONOLITHIC CONC. FOOTING (3000 PSI MIN.) REINFORCED WITH 2 #4's CONTINUOUS INSTALL 5/8" X 4" EXPANSION ANCHOR THROUGH BASE RAIL WITHIN 6" OF EACH BOW ALONG SIDES OR INSIDE EVERY END WALLS POST ALONG END WALL SECTIONS BASE RAIL ANCHORAGE SCALE: NTS 1A EYE ANCHOR 5/8' ROD 30" LONG WITH DBL 3" HELIX TOP OF ASPHAULT PAVEMENT OR STABLE GROUND SURFACE 2" WASHERS TS CONT. BASE RAIL DRILL 5/8" HOLE THROUGH THE BASE RAIL & SECURE TO ANCHOR W/ 1/2" DIA. THROUGH BOLT KICKER FASTENED TO RAFTER COLUMN TO BASE RAIL SIZE TO MATCH COLUMN 5"x5"x5/16" TS TRUSSED RAFTER 2 1/4"x2 1/4"x1/4" 3"x3"x1/4" 5"x5"x5/16" TS ROOF RAFTER 3-12 3-12 5"x5"x5/16" TS W/ 5/8" THRU-BOLTS FASTENED TO KICKER W/ 5/8" THRU BOLTS 48" 16 GA. U-CHANNEL BRACE NOTE: BRACE NOT REQUIRED IF END ENCLOSED 2 1/4"x2 1/4"x1/4" DOUBLE TS POST BY: USA QUALITY STEEL STRUCTURES, LLC.BBD ENGINEERING & DESIGN FIRM, LLC & DRAFTING DESIGN SERVICE, INC.,SCHEMATIC DESIGN ELEMENTS FOR THIS PROJECT WERE PROVIDED TO1552 6th Street S.E. - Winter Haven, FL 33880Phone: (863) 875-5602 - Fax: (863) 508-6496www.BBDEngineering.comEngineering Services Providedby Kent M. Bice, P.E.54 NOTE:DRAWING NO.SHEET OF AND NOTIFY DESIGNER OF ANY ERRORS OR OMISSIONS BEFORE STARTING CONSTRUCTION.WHILE EVERY ATTEMPT HAS BEEN MADE IN THE PREPARATION OF THESE PLANS TO AVOID MISTAKES, THE DESIGNER CANNOT GUARANTEEAGAINST HUMAN ERROR. THE CONTRACTOR IS ULTIMATELY RESPONSIBLE TO VERIFY DIMENSIONS AND OTHER DETAILS ON THE PLANSDESIGN FIRM, LLC&BBD ENGINEERINGE03061-20PREFABRICATED UTILITY STRUCTURE:Drafting Services Provided By:CAPE CORAL, FL 339091122 AMBER LAKE CT.VALKYRIE DRAFTING SERVICESDOOR OPTIONS DOUBLE OR SINGLE 2 1/4" X 2 1/4" TUBING OPTIONS: 29 GAUGE SKIN 1/2" 1/4" X 1 1/4" SDF @ 12" O.C. 2 1/2"1 7/8"18 GA.CURTAIN DOOR HEADER SCALE: NTS SECTION THROUGH ROLL UP CURTAIN 24 GA. PBR WITH BAKED ON EPOXY PRIMER & POLYESTER TOP COAT. SWINGING DOOR (SIZE VARIES, SEE PLAN) A NON-STRUCTURAL HEADER TS POST INTERIOR SIDE EXTERIOR SIDE @ 12 O.C. 1/4" X 3/4" SDF A SECTION SCALE: NTS TS RAFTER 26 GA. METAL ROOF PANEL 1-1/2" 18 GA. FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) 1/4" X 3/4" SDF's SPACED NOT MORE THAN 48" O.C. ALTERNATE FOR VERTICAL ROOF PANELS ROOF PANEL ATTACHMENT SCALE: NTS (2) - (2) - (2) - (2) 1/4" x 3/4" Fastener pattern @ all end supports (2) - (1) - (2) - (1) 1/4" x 3/4" Fastener pattern @ all interior supports 150F125-43 Hat channel 3'- 0 " S h e e t 26 GA. AG panel metal deck PANEL DETAIL SCALE: N.T.S. 5'-0" (t y p.)ClientLocationGA SOUTHERN STEEL BUILDINGS INC.2-1/2"x2-1/2"x14GA TS Double Ladder Post 2-1/4"x2-1/4"x14GA - 3" long Post 1/8 1/8 STIFFENER TO POSTS ALTERNATE FOR LARGE SINGLE POST DOUBLE LADDER POST SCALE: NTS FASTENED TO POST PER MANUFACTURER'S SPECS. IF SHEATHING IS REQUIRED, MINIMUM 7/16'" OSB FASTENED TO POSTS AT 6" O.C. (typ.) POST PER PLAN B-LAP SIDING INSTALLED PER MANUFACTURER'S SPECIFICATIONS B-LAP PANEL DETAIL SCALE: N.T.S. PER S P A CI N G LI MI T S Stiffener at 12" o.c. vertically (typ.) Engineer: Kent Bice FL License #: 50421 COA# 30468 02/01/21 AGAINST HUMAN ERROR. THE CONTRACTOR IS ULTIMATELY RESPONSIBLE TO VERIFY DIMENSIONS AND OTHER DETAILS ON THE PLANSWHILE EVERY ATTEMPT HAS BEEN MADE IN THE PREPARATION OF THESE PLANS TO AVOID MISTAKES, THE DESIGNER CANNOT GUARANTEEAND NOTIFY DESIGNER OF ANY ERRORS OR OMISSIONS BEFORE STARTING CONSTRUCTION.OF SHEETDRAWING NO.NOTE:5 5Engineering Services Providedby Kent M. Bice, P.E.1552 6th Street S.E. - Winter Haven, FL 33880Phone: (863) 875-5602 - Fax: (863) 508-6496www.BBDEngineering.comDESIGN FIRM, LLC&BBD ENGINEERINGSCHEMATIC DESIGN ELEMENTS FOR THIS PROJECT WERE PROVIDED TOBBD ENGINEERING & DESIGN FIRM, LLC & DRAFTING DESIGN SERVICE, INC.,BY: USA QUALITY STEEL STRUCTURES, LLC.16" 3.5" 1.5" 12" NOTE: WELL COMPACTED EARTH FILL 95% PROCTOR 6 MIL PLASTIC MEMBRANE 6 X 6 X #10 W.W. MESH REINF. OR MONOLITHIC FOOTER (TYP.) SCALE: NTS 1 MONOLITHIC CONC. FOOTING (3000 PSI MIN.) REINFORCED WITH 2 #5's CONTINUOUS CONCRETE: CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. COVER OVER REINFORCING STEEL FOR FOUNDATIONS, MINIMUM CONCRETE COVER OVER REINFORCING BARS SHALL BE: 3 INCHES IN FOUNDATIONS WHERE THE CONCRETE IS CAST AGAINST AND PREMANENTLY IN CONTACT WITH EARCH OR EXPOSED TO THE EARTH OR WEATHER AND 1 1/2" ELSEWHERE. REINFORCING BARS EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF 1/4" FOR FINE GROUT OR 1/2" FOR COURSE GROUT BETWEEN REINFORCING BARS AND ANY FACE OF A CELL. REINFORCING BARS USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER 1 1/2" FOR MASONRY UNITS NOT EXPOSED TO EARCH OR WEATHER. REINFORCING STEEL: THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. GALVANIZATION: METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION NOT DIRECTLY EXPOSED TO THE WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS AND NAILS EXPOSED DIRECTLY TO THE WEATHER SHALL BE IN STAINLESS STEEL OR HOT DIPPED GALVANIZED. REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDED: 1. ALL REINFORCEMENT IS BENT COLD 2. THE DIAMETER OF THE BEND, MEASURED ON THE INSIDE OF THE BAR, IS NOT LESS THAN 6-BAR DIAMETERS AND 3. REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT. EXCEPTION: WHERE BENDING IS NECESSARY TO ALIGN BARS WITH A VERTICAL CELL, BARS PARTIALLY EMBEDDED IN CONCRETE SHALL BE PERMITTED TO BE BENT AT A SLOPE NOT MORE THAN 1" OF THE HORIZONTAL DISPLACEMENT TO 6" OF VERTICAL BAR LENGTH. 4" PAD E03061-20PREFABRICATED UTILITY STRUCTURE:5of5 1 Drafting Services Provided By:CAPE CORAL, FL 339091122 AMBER LAKE CT.VALKYRIE DRAFTING SERVICESGA SOUTHERN STEEL BUILDINGS INC.Engineer: Kent Bice FL License #: 50421 COA# 30468 02/01/21 ClientLocation50'-0" MAXIMUMVARIES4" CONC. SLAB 6 X 6 #10 W.W. MESH REINF. - FIBERMESH OPTIONAL 6 MIL PLASTIC MEMBRANE WELL COMPACTED EARTH FILL 95% PROCTOR TREAT SOIL FOR TERMITES