CONCRETE PLACEMENT
INSPECTION REPORT
DATE Thursday, November 18 2021
S M T W TH F S
DAY x
BRIGHT SUN
CLEAR
OVERCAST
IN
x
BELOW 60
60-75
1 75-90
ABOVE go
x
LOW
MODERATE
HIGH
Report No
x
LOW
MODERATE
HIGH
8
x
MEMBERS/AREA INSPECTED: Concrete Pour Monitoring: South Building (12 Units) Members as follows:(12) C1 Columns on
Center row, (4) C2 Columns on Eastern row, (2) SW 1 & (2) SW 2 & (2) SW 3 & (2) SW 4 & (2) SW 5 on Eastern row. See attached
sketch for approximate location
THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED
CONTRACT DOCUMENTS AND ACCEPTED PRACTICES.
COMPLIES
YES NO NIA
x 1 SPARE VIBRATOR ON HAND
x 2 FORMS WETTED/OILED
x 3 CONCRETE TICKET SHOWS CORRECT MIX DESIGN (SEE TABLE BELOW)
x 4 CONCRETE SLUMP ON TRUCKS WITHIN SPECIFICATIONS (SEE TABLE BELOW)
x 5 TEST CYLINDERS MADE EVERY 50 YARDS OR DAYS POUR
x 6 PLACEMENTS COMPLETED WITHIN 90 MINUTES FROM BATCH TIME
x 7 CONCRETE DISCHARGE HEIGHT ADHERED TO 8 FEET
x 8 SUFFICIENT VIBRATION PERFORMED
x 9 STEEL REMAINED IN PLACE DURING POUR
x 10 P/T CABLES REMAINED IN PLACE AND WITHOUT SHARP BENDS
AREA
POURED
YDS
PSI
TYPE MIX
SLUMP
IN 2 IN
START TIME
END TIME
METHOD OF
PLACEMENT
SUPPLIER
TRK
#
Columns 1-6
5
7,500
2498871
10,40 AM
11:20 AM
Truck Pump
Maschme er
633
CIS + SW4
10
7,500
2498871
11:30 AM
12:15 PM
Truck Pum
Maschme er
408
SW 18-20
10
7,500
2498871
12:20 PM
1:05 PM
Truck Pump
Maschme er
448
SW 21-24
10
7,500
2498871
1:10 PM
1:35 PM
Truck PumpMaschme
er
2115
SW 25-26
8
7,500
2498871
2:15 PM
2.25 PM
Truck Pump
Maschme er
408
Disposition of Inspection
eSection / Area Observed
Work In Progress
6.5 In. Taken on Fir:
Re -Inspection
Re -Inspection Required
Inspection Performed By:
Inspection Certified By:
Paul Danforth, P.E.
Registered Professional No: P:E. 44653
Certified Special Inspector No: $I 1103
FBPE Certificate No: 4930'