Specs
Specs
BTUs
T115
80/80/80
112,000
80/80/63
106,000
80/50/63
74,000
Coefficient of Performance
80/80/80
5.6
80/80/63
5.4
80/50/63
4.0
Refrigerant
R410A
Heat Exchanger
ThermoLinlc(R)
Electrical
KW Input 5.9
Voltage/Hz/Phase 208-230/60/1
Minimum Circuit Ampacity 38.2
Maximum Fuse Size 60
*Over Temperature Alarm Kit available: part number STKO22 7 for single phase, STK0222 for three phase. Strongly recommended far all spa
applications.
Water Flow
Minimum/Maximum (gpm)
*A Heate.r.Bypass Kit is required when flow rates exceed the n7axi171urn: part number STKO135.
Physical
Weight (Ibs)
Size (LxWxH)
Shipping
Weight (Ibs)
Size (LxWxH)
Rated in accordance with AHRI standard 7160 water tenmp/mnbient oirlrelative humidity
Aqlacal
30/70
N&I
34" x 34" x 39"
309
38" x 36" x 43"
AquaCall has been the leading swimming pool heat pump manufacturer
since 1981, offering a full range of units to meet any heating need.
AquaCall can maintain anything from small above ground pools up to
very large commercial facilities. The chillers, as well as the heat and cool
units, can be used to create cold plunge pools for therapy as well.
Whatever your pool heating/cooling needs, AquaCal`R' can help!
Recent Posts
Is It Too Cold To Use My Swim
Pool Heat Pump?
How Do I Prepare My Heat Pu
Pool Heater for a Hurricane?
Why is my swimming pool hei
leaking?
Document L71'0098 rev 2a
Page Location. 'Jame > Installation > Plum yin-' > Clearances
CLEARANCES
• Proper air circulation is required for the heat punip to operate efficiently. Avoid placing objects near or
on top of the heat pump. This includes shrubbery and lawn furniture. 'flsese objects will also hinder
maintenance access.
• Avoid storing chemical container., near the heat punsp. The chemicals can cause equipment damage.
Ov8rhead Clearance
)vernanq v.,m
cutler
OVERHEAD
5 feet
Rainiun-utt and 032 cmi
spnnkieasstlnuldbe
directed w gay from healer
is - Ll
i
'a
kleatWave Su
BACK
nniChes
[95 cml
FRONT
3 feet
19 1 CM]
(0-vedieatt Clearance)
Overhang,,keith
(TD p View)
j 15
-----------
(Top View)
['30
OveJrvnew:
Whenpl=drigplumbing systemlayout reference theplmnbing schematics followingus section as a guide to the
sequence of equipment, valves,fittings, etc. Theplumbing mnfigurationsfortypicalinstallations art diagrammed.
In operation, itis imperative the heatpump receive waterflow within the mimmumt maximumLanges 5pecMrdfor
theparticularheatpamp. Sheuldthesystemi astallationuaderconsidetation notclosely match auy of the schematics,
contactAquaCal Technical Supportfor advice and guidance: (800) 786-7751.
PSIS ' , dMwtted&a
Industry technology changes much too rapidly for AquaCal to specify, with exactness, any items outside aad
bsyond Thm buuxpump.LV,svvecnma is th�Tbe heatpanap mostbe inso-11cain accordon with all applicable
local, state. or national codes & standards-
Comnee om to Heat Pump:
11TropiCalheatpumpscome equipped withT'PVC, plumbingunions. Connectiontositeplumbingismadevla
PVC solvent cement to the female slip socket of the plumbkpuions.
AIfDiK1tCy to'Wmtre izze:
In regions where hardwinters are typical, theunions mentioned above allow for easy disconnection/reconnecting
of the heaterfrom the plumbing system Caution do not defeatthe function of the unions —use no glue on the
threaded cordon of the unions.
yjwt'vmamn Opeirofing 1Pressulre: 50 PST
r9 ,�iwatanmWateY>VEw,vv Rafrrks:
All TropiCal models are dekened to operate successfully between flow rates of 20 to 70 &Ilons-per-minute
(CPibl) . Design theplumbing system to maintain atleast20 GP\4fiou, through the heater thehempump will not
operate correctly, nor reliably, with less than 20 GPNI of water flow supplied. If water flow rates tbroughthe
Fteatw will exceed 70 GPNI. a spring -check bypass valve will be required-, generally speaking, most residential
pools and spas will not require a bypass unless a pump of 2 BP or larger is used (for bypass valve details, see
information and plumbing schematic, folloadn ).
External lByLpa. ss Check Wvre Requirement
Forinstallations whereflow rates exceed 70 gpm an additional spring bypass check valve must be installed.
NQ1IS:
Use of the wrong size check valve may compromise the heat pump's efficiency, reliability, and may
void the factory warranty. For models T135,T115 &T65, a 5lb. Spring check valve is required.
(AquaCalPart 4.n556-)
1➢GENf)
3.3ttiayrla
r-EnWSaiaa(AMIM)
c-OLffb1or(fiA
T-Thtilmha
n-nay
r.rJIhT
i-Y6tmm�-
11-Ifeepxa
-u�-PesC6--LWc
t-Nmp
n-lid®
—
s-sty
-Wicalllaal-Flowate2terthan 70 zpmi-(2F3 Rma)
MA
:;mtatoadeditran ama•\?unu�l<lih car: etaouaL sc—uch a!�in.
Water hT & (01UT Counmeaxom
Forproperoperadon and mnv;mnm efficiency, piping comingfromthepnmp andfillaMUSTbe connectedto the
IN" ponof theheat=Lilmwise,connectpipingreImningtothepoollspatothe"OUT"portoftheheate* See
drawinzbelow.
FROM PUMP 1 FILTER
TOPOOL
ORSPA
Electrical RequiremeWm
Farlam heedthefollowln,amayresultinpermanentmjtny
or death_
?nstallationmadebyunqualifiedpersonscanresultinhazardstotiteinsiallerandothers. Theinfortnatton
conbined aftFlecuicalInsbtilationsectionisintmdedforusebyqualifiedelectacalnlstaUaiiontecbniaans:
fumiharv,rh electacalsei-icemdusnysafetystandardsandmethods.Electocadhamllationiobepefiomed
by qu alified individuals only_
Gemera la- t atioma
45 When possible, locate the equipment disconnect means within arm's reach of the heames
electrical enclosure or as close as possible to the heater. Always satisfy applicable codes and
standards.
All AquaCal heat pumps axe designed for copper conductors, only In sizing power wiring, be
especially aware of up -sizing requirements required due to vdfirig distances_ Always satisfy
applicable codes and standards.
4, Multiple heaters installed at same site generally require special sequencing controls (AquaCal part
'ASC-(member of heaters)); if yours is a multi-beaterinstallation, contact AquaCal Tecbnical Support
for assistance (800-756-7751).
10 Electricalinstallationshouldbebylicensedelectrician only.
® Connecting vernal Controllers: See document entitled "Connecting External Controllers to
Aa=Cal Heat Pumv '_ These instmateow are shipped inside heater accompanying the electrical
schematic.
t$
�asrdm.cs:?�.^• y.�._'Isw.t J'n cam maauaLt s"SD:h rnJac
GETTHE � ;1) 1a OUT OFYOUR
Y -L INVESTMENT!
• High performance titanium heat exchanger (Patented ThermoL/nOin T90, T115 and T135)
• Microprocessor controlled defrost cycle allows operation down to mid to low 40s OF
• Lockable, flip -out control panel protected against sun and weather
• Built-ir�drain pan for condensate management
• Impact resistant, rust and fade proof cabinet �` �(
• Quieter than conventional heat pumps A0
T55 T75 790
T115 T135
BTUs -
80/80/80
52,000
74,000
96,000
132,000
(water ive humidity) nt elr/
relative humidity)
80/80/63
50,000
70,000
90,000
106,000
125,000
80/50/63
33,000
49,000
65,000
74,000
84,000
C.O.P.
80/80/80
6.0
5.6
6.0
5.6
5.7
Coefficient of P•dormencro
80/80/63
5.8
5.4
5.8
5.4
5.6
(water temp/ambient air/
relaffm humidity)
80/50/63
4.0
4.0
4.2
4.0
4.0
Refrigerant R410A R410A R410A R410A R410A
Heat Exchanger
Tube in Tube
Tube in Tube
Thermot-ink®
Thermol-inks
ThermoLink®
Electrical kW Input
2.7
3.9
4.7
5.9
6.8
Voltage/Hz/Phase
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
208-230/60/1
Min. Circuit Ampacity
19.1
26.8
40.2
38.2
43.3
Max. Fuse Size
30
45
60
60
60
Water Flow
Min./Max. (gpm)
20/46 20/45
30170
30/70
30i70
A Heater Bypass Kit is
required when flow rates exceed the maximum
Physical
Weight (Ibs)
180 200
255
259
287
-
Length x Width x Height (in)
34" x 34" x 28" M' x M' x 28"
34" x 34" x 39"
34" x 34" x 39"
34" x 34" x 39"
Shipping
Weight (Ibs)
220 240
305
309
337
Length x Width x Height (in)
38" x 36" x 33" 38" x 36" x 33"
38" x 36" x 43"
38" x 36" x 43"
38" x 36" x 43"
Rated in accordance with AHRI standard 1160 water temp/ambient air/relative humidity
Specifications subject to change
Aunapo-A"'
Producing quality boat pumps since ISO?
,
AQUACAL ® 0m _� w. .
AquaCal AutoPilot, Inc. 2737 24th Street North St. Petersburg, FL 33713 727.823.5642