Loading...
HomeMy WebLinkAboutAPPROVED, PROJ-58188- Escalera Residence SealedREVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEG-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951 11.63kW PV SYSTEMCODES AND STANDARDS5751 SUNBERRY CIR,FORT PIERCE, FL 34951ESCALERA RESIDENCEVICINITY MAPSHEET INDEXG-01COVER SHEETPROJECT SITEPROJECT DESCRIPTION:OWNERHOUSE PHOTOGOVERNING CODES :FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)NATIONAL ELECTRICAL CODE 2017 (NEC)ASCE 7-16FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)A-01ROOF PLANS-01MODULE LAYOUTS-02ATTACHMENT DETAILSTRUCTURE CALCULATIONE-01ELECTRICAL LINE DIAGRAME-02WIRING CALCULATIONSE-03SYSTEM LABELINGSHEET SHEET DESCRITIONCOVER SHEETA-00NOTES AND DESCRIPTIONELECTRICAL CERTIFICATION:STRUCTURAL CERTIFICATION:DESIGN CRITERIA:WIND SPEED (ULT): 160 MPHWIND SPEED (ASD): 124 MPHRISK CATEGORY:IIEXPOSURE:CRACKING: IRONRIDGE XR100 RAILATTACHMENT: IRONRIDGE KNOCKOUT TILE MOUNTS-01.1ARTIAL RESSURE AND MODULES EXOSURESUNPRO SOLAR4492 Eagle Falls Place,Tampa, FL 33619(866) 450-1012INSTALLERCastillo Engineering Services LLC620 N. Wymore Road, Suite 250, Maitland, FL 32751TEL: (407) 289-2575Ermocrates E. CastilloLicense#: FL PE 52590ENGINEERESCALERA, CARMELO31x375 LG NEON: LG375Q1C-V5 (375W) MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESEQUIPMENT SUMMARY31 LG NEON: LG375Q1C-V5 (375W) MODULES31 ENPHASE: IQ7PLUS-72-2-US MICROINVERTERSS-02.1I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDABUILDING CODE. FBC 107, THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLAR ENERGYCENTER CERTIFICATION.DS-01-08DATA SHEETSI ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED.,CHAPTER 3. BUILDING STRUCTURE WILL SAFELYACCOMMODATE WIND LATERAL AND UPLIFTFORCES, AND EQUIPMENT DEAD LOADS.PROJECT SITESSYSTEM SIZE:11.625 kW DC STCARRAY AREA #1:464.72 SQ FT.ARRAY AREA #2:111.53 SQ FT. Section..............Elevation ...........Detail ................Detail ................(Enlarged Plan)Keyed Notes ..........Ground Terminal .....Grounding Point/rod....Solar Panel ......... orCombiner Box ..........AC Disconnect ..........Main DistributionPanel ......................Fuse ......................Overcurrent Breaker ..Inverter ....................Transformer .............Automatic ...............Transfer SwitchXX-XXXX-XXXX-XXXX-XX1CBACDMDP Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is locatedArea to be enlargedKeyed note designationon applicable sheetATS00Module with SourceCircuit numberVent, Attic fan(Roof obstruction)PV Roof AttachmentTrussesConduitFire AccessUM Utility MeterAC Alternating CurrentAPPROX ApproximateAWG American Wire GaugeCB Combiner BoxDC Direct CurrentACD AC DisconnectDISC Disconnect(E) ExistingEL ElevationEQ EqualJB Junction BoxMCB Main Combiner BoxMFR ManufacturerMIN MinimumMISC Miscellaneous(N) NewOCPD OverCurrent Protection DevicePOCC Point Of Common CouplingPV PhotovoltaicSF Squarefoot/feetSTC Standard Test ConditionsTBD To Be DeterminedTYP TypicalUNO Unless Noted OtherwiseVIF Verify In FieldWP Weather ProofGPGeneration PanelMDPMain Distribution PanelSDSoladeckNAVD North American Vertical datumMID Microgrid Interconnect DeviceSystem DescriptionThis system is a grid-tied, PV system, with PV generation consisting of31x375 LG NEON: LG375Q1C-V5 (375W) Modules with a combined STC rated dcoutput power of 11,625W. The modules are connected into 31 Enphase:IQ7PLUS-72-2-US microinverters. The inverter has electronic maximum powerpoint tracking to maximize energy captured by the PV modules. The inverter alsohas an internal ground fault detection and interruption device that is set todisconnect the array in the event that a ground fault that exceeds one ampereshould occur. The inverter has DC and AC disconnect integrated system and labelsare provided as required by the national electrical code.When the sun is shining, power from the PV array is fed into the inverter,where it is converted from DC to AC. The inverter output is then used tocontribute to the power requirements of the occupancy. If PV power meets therequirements of the loads of the occupancy, any remaining PV power is sold backto the utility. When utility power is available, but PV power is not available,building loads are supplied by the utility.The inverter meets the requirements of IEEE 1547 and UL 1741.MicroinvertersPV ModulesPoint ofUtilityConnectionUtility MeterJunctionBoxFigure 1: PV System Block DiagramREVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-00CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951NOTES ANDDESCRIPTIONSymbols:Abbreviations:66.92"40"RAILS IN THISPOSITION UNOFALL PROTECTION:ANCHORAGES USED FOR ATTACHMENT OF PERSONAL FALL ARREST EQUIPMENTMUST BE INDEPENDENT OF ANY ANCHORAGE BEING USED TO SUPPORT ORSUSPEND PLATFORMS, AND CAPABLE OF SUPPORTING AT LEAST 5,000 POUNDSPER EMPLOYEE ATTACHED, OR MUST BE DESIGNED AND USED AS FOLLOWS:·AS PART OF A COMPLETE PERSONAL FALL ARREST SYSTEM WHICHMAINTAINS A SAFETY FACTOR OF AT LEAST TWO.·UNDER THE SUPERVISION OF A QUALIFIED PERSONADDITIONAL INFORMATION·29 CFR 1926 SUBPART M, FALL PROTECTION. OSHA STANDARD.·1926.502, FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES···1926.502(D)(15)ALLOWABLE/DESIGN PRESSUREPSFDOWN PRESSURE125UPLIFT PRESSURE, 2 RAILS88LG NEON:LG375Q1C-V5 (375W)MODULES 112'-1"5 3 ' - 8 "112'-1"5 3 ' - 8 "34'-10"1 3 ' - 7 "20'-11"20'-11"UMMDPCBACDSDREVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951ROOF PLANFIRE ACCESS AND PATHWAYSAS PER NFPA 11.12.21" IMC, RMC, FMC, LFMC, PVC,HDPE, NUCC, RTRC, LFNC, FMT,ENT OR EMT CONDUIT RUN(N) SOLADECK(N) (31) ENPHASE: IQ7PLUS-72-2-USMICROINVERTERSROOF PLAN WITH FIRE SETBACKSAND PROPERTY LINESA-01SCALE: 1/16" = 1'-0"1(N) SERVICE POINT ANDUTILITY METERING(N) ALTERNATIVE POWER SOURCEAC DISCONNECT/ RAPID SHUTDOWN(N) ENPHASE IQ COMBINER BOXROOF #2(06) LG NEON: LG375Q1C-V5(375W) MODULESSUNBERRY C I R , E X I S T I N G D R I V EW A Y(N) MAIN SERVICE DISCONNECT/MAIN DISTRIBUTION PANELROOF #1(25) LG NEON: LG375Q1C-V5(375W) MODULES1'-6" FIRE SETBACK1'-6" FIRE SETBACK3'-0" FIRE SETBACK1 - S T O R Y H O U S E - FIRE SETBACK - 3 FT- ZONING SETBACK - 2 FT1'-6" FIRE SETBACK 1'-6" FIRE SETBACK 71'-0"4 2 ' - 8 " 4' - 0 " T Y P .REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951MODULE LAYOUTS-01SCALE: 3/32" = 1'-0"1MODULE LAYOUTGENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED ASSHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:SEE SHEET S-02.1 FOR SUPPORTING CALCULATIONS.2) EXISTING RESIDENTIAL BUILDING IS A W-TILE ROOF WITH MEANROOF HEIGHT OF 15 FT AND SYP 2"X4" ROOF TRUSSES SPACED 24"O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEM RETROFIT IS 22.6°DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALLREPORT TO THE ENGINEER IF ANY DISCREPANCIES EXISTBETWEEN PLANS AND IN FIELD CONDITIONS.3) FIRE SETBACK TO BE 3' FROM RIDGES AND EDGES, AND 18"EACHWAY FROM HIPS AND VALLEYS PER NFPA 11.12.2 * I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED. CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE WIND LATERALAND UPLIFT FORCES AND EQUIPMENT DEAD LOADS. *WINDZONESNON - EXPOSED MODULESEDGE / EXPOSED MODULESSPANCANTILEVERSPANCANTILEVERZONE 14' - 0"1' - 4"4' - 0"1' - 4"ZONE 1'XXXXZONE 2e4' - 0"1' - 4"2' - 0"0' - 8"ZONE 2nXXXXZONE 2r4' - 0"1' - 4"2' - 0"0' - 8"ZONE 3e4' - 0"1' - 4"2' - 0"0' - 8"ZONE 3rXXXXMODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 31 MODULESMODULE TYPE = LG NEON: LG375Q1C-V5 (375W) MODULESMODULE WEIGHT = 38.58 LBS / 17.5 KG.MODULE DIMENSIONS = 66.92"x 40" = 18.59 SFUNIT WEIGHT OF ARRAY = 2.08 PSFARRAY AREA & ROOF AREA CALC'SROOFROOF TYPEARRAYAREA(sq.Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)TILTAZIMUTHTRUSSSIZETRUSSSPACING#1W-TILE464.721014.8945.7922.6°225°2"X4"24" o.c.#2W-TILE111.53452.1810.0622.6°135°2"X4"24" o.c.(71) PV ROOF ATTACHMENT@ 24" 48" O.C. MAX.(SEE SHEET S-02 FORATTACHMENT DETAIL)(SEE SHEET S-01.1 FOR PARTIALPRESSURE OF THE MODULE)LEGEND- WIND ZONE 1 (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e (TYP)(E) FRONT YARD (E ) B A C K Y A R D(N) IRONRIDGE XR100 RAIL (TYP,)(N) (31) ENPHASE: IQ7PLUS-72-2-USMICROINVERTERSROO F # 2 T I L T - 2 2 . 6 °A Z IM . - 1 3 5 °ROOF #1TILT - 22.6°AZIM. - 225°ROOF #1(25) LG NEON: LG375Q1C-V5(375W) MODULESROOF #2(06) LG NEON: LG375Q1C-V5(375W) MODULES 1 4 ' - 0 " 4' - 0 " T Y P . 1 4 ' - 1 " 8' - 9 " 8' - 1 0 "9'-8"9'-10"14'-0"10'-2"7'-11"8' - 1 0 "8'-7"4'-0"TYP.P1P2P4P5P7P8P3P9P10P11P8P13P12REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951PARTIAL PRESSURE AND MODULES EXPOSURES-01.1SCALE: 1/8" = 1'-0"1ARTIAL RESSURE ANDMODULES EXOSURELEGEND- NON- EXPOSED MODULE- MIN. MODULE EDGE DISTANCE LINE- EDGE MODULE- MODULE EXPOSURE LINE- EXPOSED MODULE- WIND ZONE 1 (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e (TYP)NOTE : PARTIAL PRESSURES OF THE WIND ZONES ONALL MODULES HAVE BEEN VERIFIED AND ARE WITHINTHE ALLOWABLE PER THE MANUFACTURERSPECIFICATION, INSTALLER SHOULD FOLLOW THELAYOUT TO AVOID HIGHER ZONAL PARTIALPRESSURES. ANY CHANGES IN LAYOUT SHOULD BEREPORTED BACK TO THE ENGINEER OF RECORD.2h2DISTANCE : 1' - 0"0.5hDISTANCE : 7' - 6"- MISSING MODULEFOR NON-EXPOSED MODULESALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS: 88 PSF2h2FOR EXPOSED MODULES0.5h(E) FRONT YARD (E ) B A C K Y A R D ROOF #1(25) LG NEON: LG375Q1C-V5(375W) MODULESROOF #2(06) LG NEON: LG375Q1C-V5(375W) MODULES 6"REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951ATTACHMENT DETAIL2S-02SCALE:1' = 1'-0"ATTACHMENT DETAIL (ENLARGED VIEW)SOLAR MODULE(E) ROOF SHEATHINGW-TILE ROOFATTACHMENT DETAILS-02SCALE: 1" = 1'-0"12"X4" TRUSSES @ 24" O.C.GROUNDING MID/END CLAMP5/16"DIA. X 2.5"MIN.EMBEDMENT LAG SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMING2"X4" TRUSSES @ 24" O.C.2"X4" TRUSS SPANNER FORMISSED TRUSS SPANNER(IF REQUIRED)SEE (2/S-02) FORENLARGED VIEWIRONRIDGE KNOCKOUTTILE ATTACHMENTIRONRIDGE TILE REPLACEMENTFLASHING (W-TILE)5/16"DIA. X 2.5"MIN.EMBEDMENT LAG SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMINGIRONRIDGE XR-100 RAILh2PV MODULE FRAMEIRONRIDGE XR100 RAILIRONRIDGE UNIVERSALFASTENING OBJECTPV MODULE FRAMEIRONRIDGE STOPPER SLEEVEIRONRIDGE UNIVERSALFASTENING OBJECT3DETAIL, MID CLAMP FRONTS-02Scale: 6" = 1'-0"4DETAIL, END CLAMP(UFO) FRONTS-02Scale: 6" = 1'-0"IRONRIDGE XR100 RAILAPPLY A GENEROUS AMOUNT OFKARNAK SEALANT PRIOR TO ATTACHMENTINSTALL COVERING AREA SIMILAR IN SIZETO THE FLASHING. SEE SHEET DS-07 FORSEALANT SPECS . REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951STRUCTURECALCULATION REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951ELECTRICALLINE DIAGRAM1ELECTRICAL LINE DIAGRAMSCALE: NTSNOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017, AND THOSE SET FORTH BYTHE FLORIDA SOLAR ENERGY CENTER CERTIFICATION,INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUMNUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULEMANUFACTURER AND MODEL NUMBER, INVERTERMANUFACTURER AND MODEL NUMBER, AS APPLICABLE.2.ALL PANELS DOWNSTREAM OF LOAD SIDE INTERCONNECTIONTO BE PROTECTED BY A PRE-EXISTING OR AN ADDITIONAL OCPDSIZED PER NEC 408.36.3. REFER SHEET DS-08 FOR LOAD CALCULATION.(N) SOLADECK600V, NEMA 3RUL LISTEDL2L1NL2L1GN20A/2PGGGG(N) 125A ENPHASE IQ COMBINER 3(X-IQ-AM1-240-3) [WITH UPTO (4) 2-POLEBREAKERS AND ENVOYCOMMUNICATION GATEWAY]GGGGGG(N) JUNCTION BOX600V, NEMA 3RUL LISTEDGL2L1(3) #10 AWG THWN-2 – RED(3) #10 AWG THWN-2 – BLACKEGC #6 AWG THWN-2 GNDIN 1" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNL2L1GGINTERCONNECTION120% RULE - NEC 705.12(B)(2)(3)(b)UTILITY FEED + SOLAR BACKFEED200A + 50A = 250ABUSS RATING x 120%225A x 120% = 270A(3) #6 AWG THWN-2(1) #6 AWG THWN-2 GNDIN 1" PVC, IMC, RMC, FMC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT OR ENTCONDUIT RUNL2L1L2L1NNGG(N) ALTERNATIVE POWER SOURCE AC DISCONNECT/RAPID SHUTDOWN240V, 60AMP RATED,NEMA 3R, UL LISTED LOCKABLE AND NON-FUSIBLE (ACCESSILBY LOCATED ON EXTERIOR WALL WITHIN 10' OF UTILITY METER)#6 BARE CU WIRE PROTECTED PER NEC 250.64(B)GGGGGGGGGL2L1L2L1L2L1ENPHASE: IQ7PLUS-72-2-USMICROINVERTERSPV MODULESFACTORY INSTALLED 10A OR 15ABREAKER FOR ENVOYSOLAR ARRAY (11.625 kW-DC STC)(31)LG NEON: LG375Q1C-V5 (375W) MODULES(01) BRANCH OF 11 MODULES &(02) BRANCH OF 10 MODULESQ CABLEGGG20A/2PE-01GGGGGGGGGGL2L1L2L1L2L120A/2P(3) 10/2 ROMEX RUN IN ATTICOR(3) #10 AWG THWN-2-RED(3) #10 AWG THWN-2-BLACKEGC #6 AWG THWN-2 GNDIN 1" PVC, IMC, RMC, FMC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT OR ENTCONDUIT RUN(N) MAIN SERVICEDISCONNECT/MAIN DISTRIBUTIONPANEL,225A RATED, 240V.NEW OR EXISTING GROUNDINGELECTRODE SYSTEM#4 AWG THWN-2 GND BONDEDTO (2) 1/2" X 8' GND RODS MIN 6'APART PER NEC 250.53TO UTILITY GRIDL2L1L2L1GL2L1L2L1L2L1L2L1L1L2NL1L2NL1L2N(N) MAIN BREAKER200A/2P, 240VN50A/2P(3) 2/0 AWG THWN-2 CUIN 2" PVC OR EMTCONDUIT RUNSER PER NEC 310.15(B)(7)L2L1L2L1GL2L1L2L1L2L1L2L1L1L2NN(E) SUB-PANEL,150A RATED, 240V(N) MAIN BREAKER,150A/2P,240V.MIN. 6'(N) BI-DIRECTIONALSERVICE POINT ANDUTILITY METERING1-PHASE, 240VEXISTING WIRES REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951 ELECTRICAL CALCULATIONELECTRICAL NOTES1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELEDFOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR 75DEGREE C.3.THE WIRES ARE SIZED ACCORDING TO NEC 110.14.4.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALLBE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TOTHE NEAREST RIDGE, HIP, OR VALLEY.5.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICALEQUIPMENT SHALL COMPLY WITH NEC 110.26.6.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS,FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES ANDSTANDARDS.7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARENOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY.8.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED ANDREADILY VISIBLE.9.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHTRESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FORUSE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).17.THIS SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN OF PVCONDUCTORS IN COMPLIANCE WITH NEC 690.12.18.LABELING IN COMPLIANCE WITH NEC 690.12 AND 690.56(C) IS SHOWNON SHEET E-03.19.ALL CONDUITS TO BE INSTALLED A MIN OF 7/8" ABOVE THE ROOFSURFACE.WIRING CALCULATIONSI ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDABUILDING CODE. FBC 107, THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLAR ENERGYCENTER CERTIFICATION UMMDPCBACDREVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-03CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951SYSTEM LABELINGSOLARBREAKERLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))TURN RAPID SHUTDOWNSWITCH TO THE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1)PHOTOVOLTAIC SYSTEMWITH RAPIDSHUTDOWN SWITCHLABEL LOCATION:AC DISCONNECT(PER CODE: NEC690.56(C)(3))LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)WARNINGELECTRIC SHOCK HAZARDLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.13(B))TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 37.5 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNINGINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICELABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!NOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUIT-VVAHz60290A240A1.2120LABEL LOCATION:COMBINER BOX(PER CODE: NEC690.52)DATA PER PANELAC DISCONNECT11.625 KW SOLARDISCONNECT LOCATEDPHOTOVOLTAICSYSTEM MICROINVERTERSLOCATED UNDER EACHPV MODULE INROOF TOP ARRAYAC COMBINER BOXLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)LABEL LOCATION:COMBINER BOX(PER CODE: NEC690.52)LABEL LOCATION:INVERTER(PER CODE: NEC690.52)LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)WARNINGIN CASE OF EMERGENCY CONTACT:SUNPRO SOLARPH. NO. - (866) 450-1012LABEL LOCATION:MAIN DISCONNECT(PER CODE: NFPA - 11.12.2.1.5)EMERGENCY RESPONDER:THIS SOLAR PV SYSTEM IS EQUIPPEDWITH RAPID SHUTDOWN.TURN RAPID SHUTDOWN SWITCH TO THE ''OFF''POSITION TO SHUTDOWN ENTIRE PV SYSTEMLABEL LOCATION:MAIN SERVICE DISCONNECT / MAIN DISTRIBUTION PANEL, PV DISCONNECT(TEXT HEIGHT SHOULD BE A MINIMUM OF 3/8")(PER CODE: NFPA 1, 11.12.2.1)CAUTION:LABEL LOCATION:MAIN SERVICE DISCONNECT / MAIN DISTRIBUTION PANEL, PV DISCONNECT(TEXT HEIGHT SHOULD BE A MINIMUM OF 3/8")(PER CODE: NEC 690.56(B) AND NEC 705.10)POWER TO THIS BUILDING IS ALSOSUPPLIED FROM THE FOLLOWINGSOURCES WITH DISCONNECTS LOCATEDAS SHOWNGROUND ROD 2GROUNDROD 1TO WATER METERWATER PIPECU ROD, MIN.1/2" THICK,8' LONGCU ROD, MIN.1/2" THICK,8' LONGMIN 6’ APARTNEW GROUNDING RISER DETAIL#4 AWGTHWN-2 GNDPV SOLAR ARRAYSERVICE POINT ANDUTILITY METERINGALTERNATIVE POWER SOURCEAC DISCONNECT/ RAPIDSHUTDOWNENPHASE IQ COMBINER BOXMAIN SERVICE DISCONNECT/MAIN DISTRIBUTION PANELADHESIVE FASTENED SIGNS:· THE LABEL SHALL BE VISIBLE, REFLECTIVE AND SUITABLE FORTHE ENVIRONMENT WHERE IT IS INSTALLED [NFPA 11.12.2.1]· WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING].· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3]5751 SUNBERRY CIR, FORT PIERCE, FL 34951 REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-03CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-04CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-05CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-06CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-07CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERESCALERA RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-08CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5751 SUNBERRY CIR, FORT PIERCE, FL 34951DATA SHEET