Loading...
HomeMy WebLinkAboutAPPROVED UtzBatteryDrawings(1)L1 L2 G N G (E) MIN. 60 A AC DISCONNECT (LOCKABLE PER NEC 705.22). LOCATE OUTDOOR IN ACCESSIBLE LOCATION NOTES: 1. REFER TO SHEET PV.4 FOR ALL APPLICABLE ELECTRICAL NOTES. 2. SYSTEM MEETS REQUIREMENTS OF NEC 2017 690.12 FOR RAPID SHUTDOWN. INSTALL PER MANUFACTURER INSTRUCTIONS. 3. ALL CONDUCTORS SHALL BE COPPER UNLESS NOTED OTHERWISE. MINIMUM CONDUCTOR SIZES SHOWN THIS SHEET. 4. THIS SHEET IS DIAGRAMMATIC IN NATURE AND MAY NOT DEPICT ALL REQUIRED COMPONENTS OR CIRCUITS AS THEY MAY EXIST. THE PURPOSE OF THIS DIAGRAM IS TO SHOW THE MAJOR POWER SYSTEM COMPONENTS AND CIRCUITS. CONSULT EQUIPMENT MANUFACTURERS' INSTALLATION MANUALS PRIOR TO INSTALLATION AND COMMISSIONING. CIRCUIT TYPE QTY.SIZE (AWG) MIN. CONDUIT SIZE PHASE CONDUCTOR QTY.SIZE (AWG) NEUTRAL CONDUCTOR QTY.SIZE (AWG) GROUND CONDUCTOR MAX. CIRCUIT LENGTH 1 AC 2 AC 3/4"2 #6 1 #8 86' WIRE & CONDUIT SCHEDULE 1. CONDUCTOR & CONDUIT SIZES SHOWN ARE MINIMUM REQUIRED. LARGER SIZES MAY BE USED. 2. ALL CONDUCTORS SHALL BE THHN OR THWN-2 UNLESS OTHERWISE NOTED. 3. MAXIMUM CIRCUIT LENGTHS ARE BASED ON A MAXIMUM 2% VOLTAGE DROP. BRANCH NO. 1 (16) MODULES & (16) MICROINVERTERS G G L1 L2 L1 L2 #6 AWG SOLID CU EQUIPMENT GROUND CONDUCTOR CONT. RUN TO GROUND LUG ON RACKING SYSTEM. ALL ROOFTOP COMPONENTS BONDED TO RACKING SYSTEM PER NEC 690.43. MICROINVERTERS CONTAIN INTEGRATED EQUIPMENT GROUNDING. G L1 L2 N N (E) ENPHASE IQ COMBINER 80 A SOLAR COMBINER PANEL - NEMA 3R ENCLOSURE 20A/2P L1 L2 G 1 #6 (E) JUNCTION BOX NEMA 3R ENCLOSURE DC-SIDE MODEL RATED POWER Voc PHOTOVOLTAIC SYSTEM POWER TABLE MODULE QTY. MANUFACTURER Isc Vmpp Impp 1 1 1 PARALLEL SERIES 1 1 1 AC-SIDE CONT. CURRENT FREQUENCY MODULE QTY. MODEL VOLTAGE CONT. POWER MANUFACTURER MAX. BRANCH PV MODULE DC-INPUT MICROINVERTER 240 VAC 16.00 A AC 60 HZ 16 3840 W --- 20 A --- --- 16 BRANCH NO. 1 QTY.1 240 VAC 16.00 A AC 60 HZ 16 3840 W --- 20 A --- --- 16 HOME RUN OCPD RATING ** MODULE CHARACTERISTICS AT STC: CELL TEMPERATURE @ 25° C, SPECTRUM AM1.5, IRRADIANCE @ 1000 W/M² 10A/2P L1 L2 ENPHASE ENVOY (FACTORY WIRED) ENPHASE DROP CABLE SYSTEM TERMINATOR CAP INSTALLED ON END OF ENPHASE BUS CABLE SYSTEM ENPHASE BUS CABLE TYP. -+-+-+-+ENPHASE IQ7 MICROINVERTER TYP. 3/4"2 #10 1 #10 1 #8 95' L1 L2 2 G N CTRL (N) TESLA 200 A BACKUP GATEWAY 2 WITH OPTIONAL PANEL KIT INSTALLED 30A/2P L1 L2 20A/2P L1 L2 L1 L2 L1 L1 L2 L2 N1 G L1 L2 N N (N) 60A MAIN BREAKER (N) MIN. 125 A PROTECTED LOAD PANEL TESLA POWERWALL 2 CTRL GNL2L1 STORAGE CAPACITY BATTERY INVERTER ENCLOSURE MAX. OUTPUT CURRENT AC GRID BREAKER MAX. AC OUTPUT POWER BATTERY STORAGE SYSTEM: (1) TESLA POWERWALL 2 INTEGRAL LITHIUM-ION (13.5 KWH) TESLA POWERWALL 2 & BACKUP GATEWAY NEMA 3R (POWERWALL 2 & BACKUP GATEWAY) 24 A - PER UNIT 30 A/2P - PER UNIT 5000 W (CONTINUOUS, 240 VAC) - TOTAL 13.5 KWH TOTAL (13.5 KWH PER UNIT) MAX. DC INPUT POWER 7600 W (PV), 5000 W (BATTERY, CONTINUOUS) - TOTAL EXISTING EARTH GROUND GROUNDING ELECTRODE L1 L2 N G G (N) MIN. 60 A AC DISCONNECT (LOCKABLE PER NEC 705.22). LOCATE IN ACCESSIBLE LOCATION 200A MAIN BREAKER (V.I.F.) 60A/2P G L1 L2 N N EXISTING EARTH GROUND GROUNDING ELECTRODE (E) 200A MAIN DISTRIBUTION PANEL (V.I.F.) L1 L2 L2L1 N L2L1 TO UTILITY GRID 120/240 VAC SINGLE PHASE BI-DIRECTIONAL (TYP.) UTILITY KWH METER L1 L2 N (E) CIRCUIT TO REMAIN (E) CIRCUIT TO REMAIN NOTE: COMPONENTS SHOWN WITHIN DASHED LINES ARE EXISTING TO REMAIN AND APPROVED UNDER PREVIOUS PERMIT. THE ENERGY STORAGE SYSTEM BEING ADDED WILL INTEGRATE WITH EXISTING PV EQUIPMENT. --- --- 1.00 A AC 60 HZ 1 IQ7 240 VAC 240 W ENPHASE 16 --- 340 W 40.66 VDC 10.52 ADC 33.94 VDC 10.02 ADC QCELLS DUO BLK-G6 340 W 40.66 VDC 10.52 ADC 33.94 VDC 10.02 ADC 2 NOTE: OCPD SIZED FOR INPUT CURRENT FOR ENERGY STORAGE SYSTEM FROM GRID. UTILITY INTERACTIVE OUTPUT CURRENT IS LIMITED TO 16A AND COMPLIES WITH NEC 705.12(B)(2)(3)(a). DRAWING # SHEET OF DATE DRAWN BY: CHECKED BY: PROJECT:PHOTOVOLTAIC SOLAR ENERGY SYSTEMPROJECT ADDRESS:REC. NO. # SCALE AS NOTED DESIGNER HEREBY EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST OBTAINING THE EXPRESS PERMISSION AND CONSENT OF THE DESIGNER, NOR ARE THEY TO BEASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN PERMISSION AND CONSENT.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS: CONTRACTORS SHALL VERIFY AND BERESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THEDIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS.950 SUNSHINE LN, ALTAMONTE SPRINGS, FLWWW.UMASOLAR.COMENGINEERING@UMASOLAR.COMSLROREVDATEBYREMARKDOCUMENT NOT VALID WITHOUT SIGN AND SEAL FL PE #81305 JOHN L. ANTONELLI, P.E. 29127PROJECT NAME:FORT PIERCE, FL 349515207 ECHO PINES CIRCLE EAST UTZ RESIDENCE11 JLA JLA 10/14/21 PV.3L