Loading...
HomeMy WebLinkAboutProduct Approval MIAMI•QADE MUM-DADE COUNTY QWJAW PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida.33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy James Hardie Building Product,Inc. 10901 Elm Avenue Fontana,CA 92337 SCOPE:This NOA is being issued under the applicable rules and regulations governing the use of construction. materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product . Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: "Hardie", "Cem" and"Prevail"Planks and Panels Fiber Cement Siding and Soffit APPROVAL DOCUMENT:Drawing No.PNL,PLK&SOFF,titled"HardiePanel,CemPanel,Prevail Panel;HardiePlank,CemPlank Prevail Lap Siding;HardieSoffit,CemSoffit Panel;Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12,dated 04/24/2013,_prepared by the manufacturer,signed and sealed by V.Andrew Tan,P.E. on 09/29/2020,bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami- Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo,Plant City,Florida,and the following statements: "ASTM C 1186 Type A compliant"and"Miami-Dade County Product Control Approved"is to be located on each siding plank or panel and per FBC 1710.9.2 and 1710.9.3 on soffit panels. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination-and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#17-0821.21 and consists of this page 1 and evidence pages E-1 and E-2,as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M.Utrera,P.E. NOA No.20-0730.06 . rtwMi n�we COUNW Expiration Date:May 1,2022 ' Approval Date:November 12,2020 Page 1 . •{ � �.i � � � � � � .;11,. ,. � "t'. � is � � _ ' � ��1 I � . ', �' ... 4 � 1:!'. l _ _ James Hardie Building Products,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOAs A. DRAWINGS"Submitted under NOA#13-031L07" 1. Drawing No.PNL,PLK& SOFF,titled"HardiePanel, CemPanel,Prevail Panel; HardiePlank, CemPlank Prevail Lap Siding;HardieSoffit,CemSoffit Panel; Installation Details Wood/Metal Stud Construction",.sheets.1 through 12 of 12,dated 04/24/2013,prepared by the manufacturer, signed and sealed by Ronald I. Ogawa, P.E. B. TESTS "Submitted under NOA#13-031L07" 1. Test reports on 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 2) Cyclic Wind Pressure Loading per FBC,TAS,203-94 along with marked-up drawings and installation diagram of HardiePlank, HardieSoffit and HardiePanel,prepared by Intertek Testing Services NA LTD,Test Report No. 100733361COQ-004, dated 08/24/2012,with revision 1 dated 04/25/2013, signed and sealed by Rick Curkeet,P.E. "Submitted under NOA k 02-0729.02" Laboratory Report Test Date Signature 2. ATI-16423-1 PA 202 &203 03/18/96 A.N. Reeves P.E. 3. ATI 16423-2 PA 202&203 03/18/96 A.N. Reeves P.E. 4. ATI 16423-3 PA 202 &203 03/18/96 A.N.Reeves P.E.. C. CALCULATIONS 1. None, D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS "Submitted under NOA#15-0122.04" 1. Statement letter of code.conformance to the 5t'edition(2014)FBC issued by Ronald I. Ogawa&Associates,Inc., dated 10/26/2014, signed and sealed by Ronald I. Ogawa,P.E. Carlos M.Utrera,P.E. Product Control Examiner NOA No.20-0730.06 Expiration Date:May 1,2022 Approval Date:November 12,2020 E-1 — -- --� . . ,,�, . s -, � „ , , :.� _ . ;�' � .. , , i _ t� �� '. .� � :i' '� •fib . i � .. � � I � i � �` � , �'�� � r � 'e', � ,r James Hardie Building Products,Inc. J NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No.PNL,PLK&SOFF,titled"HardiePanel,CemPanel,Prevail Panel; HardiePlank,CemPlank Prevail Lap Siding;HardieSoffit,CemSoffit Panel;Installation Details Wood/Metal Stud Construction",sheets 1 through 12 of 12,dated 04/24/2013, acturer,signed and sealed by V.Andrew Tan,P.E. on 09/29/2020. prepared by the manuf B. TESTS 1. - None. . C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to the 7t'Edition(2020) of the FBC and of no financial interest issued by Construction Applied Engineering, dated 07/22/2020, signed and sealed by V.Andrew Tan,P.E. "Submitted under NOA #17-0821.21" 2. Statement letter of code conformance to the 6'Edition(2017)FBC and of no financial interest issued by Ronald I. Ogawa&Associates, Inc., dated 07/30/2017, signed and sealed by Ronald I. Ogawa, P.E. Carlos M.Utrera,P.E.. Product Control Examiner NOA No.20-0730.06 Expiration Date:May 1,2022 Approval Date:November 12,2020 E-2 WALL LENGTH SEE PRODUCT DESCRIPTION. Stud Spacing at 16"O.C. DETAIL A HardiePanel®,Cempanel®,& B� onasbestos fibe-cement products _ P T n • ' tested in accordance with ASTM ( plywood sheathing in ! 1 C1186 Grade II,Type A and meeting //I I acco�itance with Florida YP 9 the requirements of the Florida j PRODUCT REVISED ��� ��'; C N 3 "��✓ /,� ;E Building Code Section Building Code. as complying with the Florida �_ C• L Building Code =i .� �`f i! •�• 2322.3 ! NOA-No. 20-0730.06 id 81 ;, f ( PANEL DIMENSIONS. WALL Expiration DateOS/01/2022 `�` is Water-resistive width Length Thickness HEIGH i '. ; ! barrier per Florida 4' 8,9,10' 5/16" Mlaml-Dade Product Control �'4 �'!' I Building Code ATE O Section 1404.2 ! �' I _— C'� , ' DESIGN-PRESSURE.RATING I! ! != 'i COR10,� �j��� E , Installation Design Pressure i Ito Wood Studs Wood Studs -76 psf !, HardiePanel, Impact Resistant— SECTION B-B Cempanel, Planks installed over 5/8"thick/5 ply Nails at 16"O.C.(typ.) Prevail Panel APA rated plywood sheathing 3/8"Minimum Edge Distance Siding DETAIL HARDIEPANEL CEMPANEL.PREVAIL PANEL SIDING INSTALLATION DETAILS Sheathing fastener,as described in All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's Note 1 . installation recommendations,and the applicable sections of the Florida Building Code. �\ Wood studs where HardiePanel,Cempanel,Prevail Panel Siding will be installed shall be Panel fastener,as described in designed by an Engineer or Architect per the Florida Building Code and the requirements of this ,; Note 2 N.O.A. • - [Note 1]5/8"thick/5 ply APA rated plywood sheathing shall be attached to the studs in 'I in Code Section 2322.3. i withFlorida Building accordance wit Flon The sidingg HardiePanel,Cempanel, panels shall be installed over 5/8"thick/5 ply APA rated plywood sheathing supported P by a minimum of ZX4"S-P-F wood studs spaced a maximum of 16"O.C. Prevail Panel Siding [Note 2]The siding panel fastener shall be a 2"long,0.223"head diameter,0.092"shank diameter,corrosion resistant siding nail;the fasteners shall be spaced at 6"O.C.at panel edges and intermediate studs;the fasteners shall be driven through the 5/8"thick/5 ply APA rated /! plywood sheathing into wood studs located at 16"O.C. Water-resistive barrier per Fasteners shall have a minimum edge distance of 3/8"and a minimum clearance of 2"from Florida Building Code Section comers. - 1404.2 �/. =- - HARDIEPANEL,CEMPANEL, PREVAIL PANEL ` 5!8"thick/5 ply APA rated INSTALLATION DETAILS WOOD STUD CONSTRUCTION plywood sheathing fastened in accordance with Florida Building James Hardie Building Products, Inc. 1 I'. Code Section 2322.3 10901,Elm Avenue Fontana,CA 92337 2"X 4"S-P-F Wood Studs Phone:909-356-6300 SIZE FSCM No DWG No REV• The wall and soffit frames are to be designed I1. by the Architect or Engineer of Record in Fax 909-427-0634. A PNL-PLK-SOFF 2 compliance with the Florida Building Code. Creator: E.Gonzales SCALE 172".=-1'=0" Date:9/29/2020 sHEEr 1 OF 12 Fastener Spacing per Florida Cladding Building Code Section 2322.3� 16.00in. •. ;.. Framing Fastener Spacing per Florida ',, j Sheathing li, Building Code Section 2322.3 I, ;;? _ 's`�r T A PRODUCT REVISEDjs '9 �j as complying with the Florida Building Code •Z�Z21 NOA-No. 20.0730.06 ex�yo•;816b2 �;* Expiration Date05/01/2022 •' ' By ✓"� OF ,' !d� Miami-Dade Product Control SfA� FC.WO �I171:1111'fi. �l f.Zcl.�, , FRAMING C' ■_ NOMINAL 2"X 4"S-P-F WOOD STUDS 16"O.C.FASTENED WITH 3-112"16d COMMON NAILS(2 PER TOP AND FOR METAL AND-WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE BOTTOM CONNECTION) ,NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING. - - - ■ NOMINAL 5/8"THICK/5 PLY APA RATED PLYWOOD HARDIEPANEL,CEMPANEL,PREVAIL PANEL SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA f BUILDNG CODE SECTION 2322.3 INSTALLATION DETAILS WOOD STUD CONSTRUCTION CLADDING - . • THE PANEL IS FASTENED WITH 2"LONG,0.22W HEAD I James Hardie Building Products, Inc. DIAMETER,0.092"SHANK DIAMETER,CORROSION r 10901 Elm Avenue RESISTANT SIDING NAILS,PLACE NAILS 6"O.C.AT __ •_ -__ _�__ __ Fontana,CA 92337 PANEL EDGES AND INTERMEDIATE STUDS ` Phone:909-356-6300 - -SIZE -- FSCMN6---_.. DWG NO- '" - . REV-, i = Fax 909-427-0634 A i PNL-PLK-SOFF j 2 Creator:E.Gonzales SCALE Date:9/29/2020 SHEET 2 OF 12 WALL LENGTH' SEE PRODUCT DESCRIPTION Stud.:Spacifig at 16"O.C. HardiePanel®, Cempanel®,&Prevail® B*--, DETAIL A� Panel Siding materials are nonasbestos i1 ___ _ _ % �: 518"thick/5 ply APA rated fiber-cement products tested in "� `' — " �`' plywood sheathing fastened accordance with ASTM C1186 Grade II ! { + i ~ _~-^ Type A and meeting the requirements of t { / ,: to metal studs as described PRODUCT REVISED tt, -*� ,N 3 '� './i the Florida Building Code. . ! as complying with the Florida �. in Note 1 f Building Code 2 2 � ,I � p NOA-No. 20.0730.06 r i ��NO. 166 .*= PANEL DIMENSIONS `? Water-resistive Width Length Thickness WALL Expiration Date 05/01/2022 ,i '{ is barrier per Florida 4' 8,9,10' 5/16" HEIGHT � �� � �{ _[��;{' ! Building Code By STATE OR' DESIGN PRESSURE RATING '3 Miami-Dade Product Control I '�1 ; �/ {' Section 1404.2 /; !I t .,- i l!; It_. i, % 1jFLORIQh�' � ��� ' (a j. Installation Design Pressure ffjN'/o��� , `�\ ! 20ga,3-5/8"X 1-5/8" Metal Studs -104 psf milt 12��� I Metal C-stud _ ! ii i -- c -- _ Impact Resistant- -- :----- ._—_ _ ... —.: .: HardiePanel, ! —►' SECTION tB Cempanel, . Panel installed over 5/8"thick 15 ply B ==. APA rated plywood sheathing Nails at 6"O.C.(typ.) Prevail Panel i 3/8"Minimum Edge Distance Siding HARDIEPANEL.CEMPANEL PREVAIL PANEL SIDING INSTALLATION DETAILS ! ■ All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's DETAIL A installation recommendations,and the applicable sections of the Florida Building Code., '--- a Metal.studs where HardiePanel,Cempanel,Prevail Panel Siding will be installed shall be l " Sheathing fastener,as designed by an Engineer or Architect per the Florida Building Code and the requirements of this described in Note 1 N.O.A. j [Note 1]5/8"thick/5 ply APA rated plywood sheathing shall be attached to metal studs at 6"oc Panel fastener,as described in at panel edges and all intermediate supports using a No.8-18,0.315"head diameter x 1-1/4"Iong; Note 2 bugle head screw /'• ; The siding.panels shall be installed over 5/8"thick/5 ply APA rated plywood sheathing ' supported by a minimum 20ga,Nominal 3-5/8"X 1-5/8"Metal C-studs spaced a maximum of 16" r O.C. f ; Zr HardiePanel®Siding ■' [Note 2]The siding panel fastener•shall be a minimum No.8-18,0.315"head diameter X 1-5/8" long*ribbed bugle head screw(*pr screw shall have at least 3 full threads penetrating-metal framing);the fasteners shall be spaced at 6"O.C.at panel edges and intermediate studs;the / fasteners shall be driven through the 5/8"thick/5 ply APA rated.plywood sheathing into metal. Water-resistive barrier per studs located at 16"O.C. 9 Fasteners shall have a minimum edge distance of 3/8 and a minimum clearance of 2 from.�. •Florida Building Code Section minimum g " " 1404.2 comers. HARDIEPANEL,CEMPANEL,PREVAIL PANEL 5/8"thick/5 ply APA rated INSTALLATION DETAILS METAL STUD CONSTRUCTION plywood sheathing fastened, to metal studs as described James Hardie Building Products,Inc. T. in Note 1. , ■ , 10901 Elm Avenue Fontana,CA 92337 20ga,3-5/8"X 1-5/8"Metal C-stud - The wall and soffit frames are to be designed Phone:909-356-6300 s¢E FSCM NO DWG NO REV r Fax 909-427-0634` A PNL-PLK-SOFF by the Architect or Engineer of Record in 2 i compliance with the Florida Building Code. Creator:E.Gonzales SCALE 1/2 ,T-0". Date:9/29/2020 SHEET 3 OF 12 / ; / / i ,� /� / ' /� /� � , / � ��� � .. .. /' \ �. �� � � .i _. , `� ' ��� . S .� t r_ .. ti �\ \\ \�\ �` .. `` �. \\ \\ \\� Cladding 6.00in. g6.00in: . :.: 6.001n Framing Sheathing 6.00in:. , I PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0730.06 Expiration Date05/01/2022 - \\\ ¢E ,r A. Expiration • • \ A By 2�ZgiL1•,. /. MlamWade Product Control �' _q F .,� . FRAMING /l�/ S`S1QSd, L ~� •_ NOMINAL 20 GAUGE 3-5/8"X 1-5/8"STEEL-STUDS.16"O.C. //�� -���,�\1;, FASTENED WITH 5/8"WAFER HEAD SCREWS(2 PER TOP AND BOTTOM CONNECTION)THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE ■, BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)' ' COMPLIANCE-WITH THE FLORIDA BUILDING CODE SHEATHING ■' NOMINAL 5/8"THICK/5-PLY APA RATED PLYWOODSHEATHING-TO METAL'STUDS AT 6"OGAT PANEL- EDGES AND ALL INTERMEDIATE SUPPORTS USING A HARDIEPANEL,CEMPANEL,PREVAIL PANEL NO.8-18,0:315"HEAD DIAMETER X 1-1/4 LONG BUGLE INSTALLATION DETAILS METAL STUD CONSTRUCTION HEAD SCREW CLADDING, - THE PANEL IS FASTENED WITH NO.8-18,0.315"HEAD James Hardie Building Products, Inc. DIAMETER X 1-5/8"LONG CORROSION RESISTANT • 10901_Elm Avenue RIBBED BUGLE HEAD SCREWS(SCREW SHALL HAVE AT Fontana,CA 92337 SIZE ,I -FSCM NO _ _. LEAST 3 FULL THREADS PENETRATING THE METAL Phone:909-356 6300 owc No REV FRAMING),PLACE SCREWS 6"O.C.AT PANEL EDGES Fax 909-427-0634- A PNL-PLK-SOFF 2 AND INTERMEDIATE STUDS Creator:E.Gonzales SCALE 1,'=0" Date:9R9/2020 sHeET 4 OF 12 Stud Spacing at 16"O.C. WALL LENGTH SEE PRODUCT DESCRIPTION DETAIL A HardiePlank®,Cemplank®,& Prevail®Plank Lap Siding materials --- j r -- 5/8"thick/5 ply APA are nonasbestos fiber-cement .-: ri _.__.._____ �N �d 1 I l � i `):rated plywood Products tested in accordance with ..sheathing in ASTM C1186 Grade 11 Type A and PRODUCT REVISED �.j vX' S �;-4 OF ' E�% accordance with meeting the requirements of the as complying with the Florida Florida.Building-Code. '3 I Building Code i';; i fi•2 '.3 Florida Building Code i Noe►-nlo. 20-0730.06 I' _ �..'X NG $$ Z }. : Section2322:3 PANEL DIMENSIONS WALL Expiration Date05/01/2022 = - — '- �, Water-resistive Width Length Thickness By ;HEIGHT i i i A. barrier per Florida 59=1/2" 12' 5/16" Miami-Dade Product Control ' i ;._ Building Code { •1.3 1, 1 ,J i j : ! X'�/� 5, i R1v ��� ;'� I Section 1404.2 DESIGN PRESSURE RATING ' i is - I 2"X V S-P-F Installation Design Pressure 1�� Wood studs Wood Studs -92 psf Lap Siding Impact Resistant- Ba--- ' Nails at 1fi O.C. t �3EC O Planks installed over 5/8"thick/5 ply; , 3/4"Minimum Edge Distance " yp') B;g 1-1/4"tall X 5/16" APA rated plywood sheathing thick starter strip. DETAIL A Sheathing fastener,as HARDIEPLANK CEMPLANK PREVAIL LAP SIDING INSTALLATION DETAILS described in Note 1 i All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's installation recommendations,and the applicable sections of the Florida Building Code. Wood studs where HardiePlank,Cemplank,Prevail Lap Siding will be installed shall be designed by an' Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. ' ? ■: [Note 1]5/8"thick/5 ply APA rated plywood sheathing shall be attached to the studs in accordance \; Siding fastener,as with Florida Building Code Section 2322.3. described in Note 2 ■ Planks shall be applied horizontally commencing from the bottom course of the wall with 1:114"wide laps at the top of the plank such that the exposure area of each plank is:5 8-1/4"vertically. HardiePlank, ■' [Note 21 The siding fastener shall be a 2-1/2"long,0.223"head diameter,0.092"shank diameter, i corrosion-resistant siding nail;The siding is fastened_-5B-1/4"O.C.vertically and 16"O.C..horizontally; Cemplank, Prevail ` Lap Siding fasteners are driven into wood studs through 5/8"thick/5 ply APA rated plywood sheathing,fasteners 1i' are placed in the overlapping area approximately 3/4"from the bottom edge of the overlapping plank. Vertical joints shall be placed over studs. / Water-resistive barrier +_`' The planks shall be installed over 5/8"thick/5 ply APA rated plywood sheathing supported by a per Florida Building minimum of 2"X4"S-P-F wood studs spaced a maximum of 16"O.C. Fasteners shall have a minimum edge distance of 3%8". Code Section 1404.2 - �` l %AHARDIEPLANK,CEMPLANK' PREVAIL LAP SIDING 5/8"thick/5 ply APA rated -- �'" plywood sheathing fastened INSTALLATION DETAILS WOOD STUD CONSTRUCTION in accordance with Florida ' James Hardie Building Products, Inc. Building Code Section f 2322.3 10901 Elm-Avenue Fontana,CA 92337 2"X 4"S-P-F Wood Studs i, i Phone:909-356-6300 SIZET FSCM NO DWG NO REV The wall and soffit frames are to be designed Fax 909-427-0634 A PNL-PLK-SOFF 2 by the Architect or Engineer of Record in compliance with the Florida Building Code. Creator:E.Gonzales SCALE 1/2"=,1'-0"' Date:9I29/2020 SHEET 5 OF 12 i i ' i� . _ < ., _. � ., _ � S s ! 5 \\\\\ , i Fastener Spacing per Florida Building Code Section 2322.3 ` i 1ti in.OC Cladding • ,Framing i �� ' •' Fastener Spacing per Florida Building,Code Section 2322.3 Sheathing �b 0.751n- i PRODUCT REVISED as complying with the Florida Building Code Y _;NOA-No. a Expiration Date05/01/2022 �+ Nltaml-Dade Product control • • ���1 ��t� �fi}+'T ,l/ ORI � } i Al* I : FRAMING. f�11J 11'.111�11.' Zq°�Z� • NOMINAL 2"X 4"S-P-F WOOD STUDS 16"O:C,FASTENED WITH 3-1/2 16d COMMON NAILS-(2 PER TOP AND BOTTOM CONNECTION) FOR METALAND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE f :•: THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE ,SHEATHING; - NOMINAL 5/8"THICK/5 PLY APA RATED PLYWOOD SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA, HARDIEPLANK,CEMPLANK, PREVAIL LAP SIDING BUILDING CODE SECTION 2322.3 INSTALLATION DETAILS WOOD STUD CONSTRUCTION CLADDING • PLANKS OVERLAP 1-1/4" THE EXPOSURE IS 58-1/4" James Hardie Building Products,Inc. 10901 Elm Avenue ■• THE PLANKS ARE FACE NAILED WITH 2-1/2"LONG,0.223 - 1 Fontana,CA 92337 HEAD DIAMETER,0.092"SHANK DIAMETER,CORROSION. RESISTANT SIDING NAILS,PLACED 3/4"UP FROM THE phone:909-356-6300 size FSCM14o DWG NO REv` BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATIONlilFax 909-42Z-0634. A PNL-PLK-SOFT 2 1 Creator:E.Gonzales SCALE Date:W912020 SHEET 6 OF 12 Stud Spacing at 16"O.C:, WALL LENG_TH SEE PRODUCT DESCRIPTION B<-� � DETAIL AHardiePlank®,Cemplank®,and t Prevail®Plank La Siding materials 5/8"thick/5 p PA are nonasbestos fiber-cement 1t c JJ�� _ rated plywoodlyA �) i.i� t `•,�� �'r J 'l sheathing fastened products tested in accordance with t, ASTM C1186 Grade II,Type A and to metal studs as �.� meeting the requirements of the PRODUCT REVISED '�' t. described in Note 1 PROD g t { as complying with the Florida a N� $ i:� * Florida Buildin Code. q ( Water-resistive Building Code ;, �, i. Noa-No. 20-0730.06 !! barrier per Florida i'X f: WALL : _ P :PLANK DIMENSIONS HEIGHT'? ( .( Expiration Date05/01/2022 ;,,�' i �� c QF. {,lllj ,i Building Code Width Length Thickness _ Section 1404.2 5 9-1/2" 12' 5/16" By 0-1 Miami-Dade Product Control s j'• 1 t��f�`�, ­Cut �; 20 a�3-5/8"X 1-5/8" g. DESIGN PRESSURE RATING MeQ C-stud t t i i' 11111 --Zq 2(11; Installation Design Pressure HardiePlank, Metal Studs -92 psf - - =- - -- - _ Cemplank Prevail B t--- '�' SECTI'O,.'.. Lap Siding Impact Resistant— 3/4 Minimum Edge Distance Nails at 16"O.C.(typ.) B-B 1-114"tall X 5/16° Planks installed over 5/8"thick/5 ply,; APA rated plywood sheathing thick starter strip DETAIL A HARDIEPLANK CEMPLANK PREVAIL LAP SIDING INSTALLATION DETAILS All installation shall be done in conformance with this Notice of.Acceptance,the manufacturer's installation Sheathing fastener,as recommendations,and the applicable sections of the Florida Building Code. described in Note 1 Metal studs where HardiePlank,Cemplank,Prevail Lap Siding will be installed shall be designed by an �A Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. [Note 1]5/8"thick/5 ply APA rated plywood sheathing shall be attached to metal studs at 6"oc at panel j edges and all intermediate•supports using a No.8-18,0.315"head diameter x 1-1/4"long bugle head screw Siding fastener,as pP 9 " Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4 wide laps at described in Note 2 the top of the plank such that the exposure area of each plank is:5 8-1/4"vertically. [Note 2]The siding fastener shall be a minimum No.8-18,0.315"head diameter X 2-1/4".long*bugle•head,' ', screw over metal studs For screw shall have at least 3 full threads penetrating metal framing);The siding is HardiePlank, fastened:5 8-114"O.C.vertically and 16"O.C.horizontally;fasteners are driven into metal studs through 518"; Cemplank, thick/5 ply APA rated'plywood sheathing,.fasteners are placed in the overlapping area approximately 3/4" t Prevail Lap Siding from the bottom edge of the overlapping plank. ■ Vertical joints shall be placed over studs. Water-resistive The planks shall be installed over 5/8"thick/5 ply APA rated plywood sheathing supported by a minimum 20ga,Nominal 3-5/8"X 1-5/8"Metal C-studs spaced a maximum of 16"O.C. barrier per Florida ■. Fasteners shall have a minimum edge distance of 3/8". Building Code - Section 1404.2 HARDIEPLANK,CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS METAL STUD CONSTRUCTION 5/8"thick/5 ply APA rated _ plywood sheathing fastened to James Hardie Building Products,Inc. metal studs as described in1IN 10901 Elm Avenue Note 1 Fontana,CA 92337 20ga,3-5/8"X 1-5/8"Metal C-stud Phone:909-356-6300 SIZE FSCM No DWG NO REV : The wall and soffit frames are to be designed Fax 909-427-0634 A PNL-PLK-SOFF 2 by the Architect or Engineer of Record in compliance with the Florida Building Code. Creator:E.Gonzales scakE 1l2"=1'-0" Date:9/29/2020 SHEET 7 OF 12 ... - , .. �� _, �� . . � ... ��, _. �� -� �� _ , . �\\ ` . V � �si, �.;. `� �\ �. �'�� .. �, li � 6.00in _ .'16 in .O _. ', �Cladding ' 6.00in. • ~-; i �' Framing 6.00in.00 Sheathing , i 0.75in T' PRODUCT REVISED 4 as complying with the Florida Building Code _NOA-No. 20-0730.06 Expiration Date 05101/2022 I'�ffll ` T / 1 ade Product Control . ,MIamF-D J' II - o .rr e8.25in. FRAMING' 4!i . O P 1 R • `� ■ NOMINAL 20 GAUGE 3-5/8"X 1-5/8"STEEL•STUDS 16" O.C.FASTENED WITH 5/8"LONG RIBBED BUGLE HEAD SCREWS(2 PER TOP AND BOTTOM CONNECTION) ,ZD� 1 i l�� RE T THE WALL AND SOFFIT FRAMES A O BE DESIGNED FOR METAL AND WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND GR�UITY LOAD ARE .., BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE.PROVISIONS FOR THESE LOADS) COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING. NOMINAL 5/8"THICK/5 PLY APA RATED PLYWOOD j SHEATHING TO METAL STUDS AT 6"OC AT PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A _ ------ _-- { N0.8-18,0.315 HEAD DIAMETER 1-1/4 LONG BUGLE HARDIEPLANK,CEMPLANK; PREVAIL LAP SIDING HEAD SCREW STUD.CLADDING. INSTALLATION DETAILS METAL CONSTRUCTION ■: PLANKS OVERLAP 1-1/4" ■: THE EXPOSURE IS s 8-1/4" James Hardie Building Products, Inc. �. THE PLANKS ARE FASTENED WITH NO.8-18,0.315' !Fax 10901 Elm Avenue HEAD DIAMETER X 2-1/4"LONG CORROSION- Fontana;CA 92337 RESISTANT RIBBED BUGLE HEAD SCREWS.(SCREW SHALL HAVE AT LEAST 3 FULL THREADS :909-356-6300 SIZE Fscnn nio Dwc NO REV PENETRATING THE METAL FRAMING),PLACED 3/4"UP 909-427-0634 _ { A PNL-PLK-SOFF 2 FROM THE BOTTOM EDGE OF THE PLANK AT EACH Creator:E.Gonzales I SCALE 1"'=1'=0id Date:9/29/2020 SHEET 8 OF 12 STUD LOCATION 1NAlLIENGTH, , SEE PRODUCT DESCRIPTION Stud S'p"acing at 16"O.C: - DETAIL A HardieSoffit®&Cemsoffit@ materials are B nonasbestos fiber-cement products tested in �. accordance-with ASTM C1186 Grade II,Type A ' 4�` ' 1 and meeting the requirements of the Florida Building Code. PRODUCT REVISED as complying with the Florida SOFFIT DIMENSIONS - I 2 X 4"S-P F Width Length Thickness Building Code :'i �{' Noa-lo. 20-073006 i_ Wood Studs 4, 8' 1/4 WALL ? ) :q Expiration Date05101/2022 ''1 "• HEIGHT:i ?; �, DESIGN PRESSURE RATING :3 Ti ?:;, Miami-Dade Product Control HardieSoffit, Installation Design Pressure "Cemsofft Wood Studs -70 psf i ? i, jt -: A4. SECTION B-B � ;_�VZ' �f�'•�• ��., Nails at 4"O.C.(typ.) ;2 jo 3/8"Minimum Edge Distance 1 t' 1 C 1 ,U DETAIL /Xl:�,S?)OAd �\ HARDIESOFFIT.CEMSOFFIT PANEL INSTALLATION DETAILS Soffit fastener,as ! All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's ` described in Note 1 installation recommendations,and the applicable sections of the Florida Building Code. .,■, Wood studs.where HardieSoffit,Cemsoffit will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. i r; The soffit shall be installed over minimum 2"X4"S-P-F wood studs spaced a maximum of 16"O.C. HardieSoffd,Cemsofft [Note 1]The soffit fastener shall be a 2"long,0.223"head diameter;'0.092"shank.diameter, �:, f`i �; ■' corrosion resistant siding nail;the fasteners shall be spaced at4"O.C.at panel edges and !; 1 intermediate studs;the fasteners shall be driven into wood studs located at-16"O:C. �\ Fasteners shall have a minimum edge distance of 3/8 and a minimum clearance of 2"from corners: ' HARDIESOFFIT,CEMSOFFIT PANEL - INSTALLATION DETAILS WOOD STUD CONSTRUCTION Minimum 2"X 4"S-P-F Wood Studs James Hardie Building Products, Inc. The wall and soffit frames are to be 10901 Elm Avenue A esigned by the Architect or Fontana,CA 92337 !. Engineer of Record in compliance NPhone:909-356-6300 ' SIZE FSCM No DWG No REV I With the Florida Building Code. Fax 909-427-0634 A PNL-PLK-SOFF 2 Creator:E.Gonzales SCALE 1l2 =;1'-0" Date:9/29/2020 SHEET 9 OF 12 4.00in. 16.00in. ` _. ..,Cladding Framing . 4.o0in. PRODUCT REVISED \ ! ' ' as complying with the Florida • • , . w3, €7 p jig Building CodeVTw:H Non-No. 20-0730.06 Expiration Date05/01/2022 �p n10:81662- 4. By rill � . Miami-Dade Product Control ' • �/ i '3'i'A E OF� i FRAMING NOMINAL.2"X 4"S-P-F WOOD STUDS 16"O.C. FASTENED WITH 3-1/2"16d COMMON NAILS(2 PER TOP AND BOTTOM FOR METAL AND WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE CONNECTION) NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS.FOR THESE LOADS) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD`IN'COMPLIANCE WITH THE FLORIDA BUILDING CODE - CLADDING THE SOFFIT IS FASTENED WITH 2 LONG,0.223!'HEAD I HARDIESOFFIT,CEMSOFFIT PANEL DIAMETER,0.092"SHANK DIAMETER,CORROSION INSTALLATION DETAILS WOOD STUD CONSTRUCTION RESISTANT SIDING NAILS,PLACE NAILS 4"O.C.AT PANEL EDGES AND INTERMEDIATE STUDS James Hardie Building Products, Inc. 10901 Elm Avenue Fontana,CA 92337 Phone:909-356-6300° s¢e Fscnn No owc No _ _REV,Fax 909-427-0634 A - PNL-PLK-SOFF 2 , Creator:E.Gonzales SCALE 1"_'1'-0 Date:9129/2020 sriEEr 10 OF 12 - WALL LENGTH- PRODUCT DESCRIPTION Stud Spacin ,,at 16'O.C. SEE HardieSoffit®&Cemsoffit®materials DETAIL A are nonasbestos fiber-cement products tested in accordance with ASTM C1186 i 1 Grade 11,Type A and meeting the i•i �,, J requirements of the Florida Building Code. PRODUCT REVISED as complying with the Florida Bonding code SOFFIT.DIMENSIONS i 7 1 No"o. 20-0730.06 !`� i' 20ga,3-5/8"X 1-518" WALL i'' Expiration Date i" !; etal C-stud Width Length Thickness HEIGHT ' i By i 4' 8, /„ i Miami-Dade Product Control Lt HardieSoffd, Cemsoffit DESIGN PRESSURE RATING Installation' e,i n Pressure R Metal StudjsPA `�\�t:� Li - SECTION B-B .'�eXP ,B _ No. 81662 t, Nails at 6"O.C.(typ.) 3/8"Minimum Edge Distance „D STATE OF FCORIOA•`C2�� DETAIL A ASS/Qjvltzo HARDIESOFFIT...CEMSOFFIT PANEL INSTALLATION-DETAILS ■ All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's installation recommendations,and the applicable sections of the Florida Building Code. Soffit fastener,as § Metal studs where HardieSofft,Cemsoffit will be installed shall be designed by an Engineer or described in Note 1 Architect per the Florida Building Code and the requirements of this N.O.A The soffit shall be installed over minimum 20ga, Nominal 3-518"X 1-518"Metal C-studs spaced 1, a maximum of 16"O.C. HardieSoffit,Cemsoffit [Note 11 The soffit fastener shall be a minimum No.8-18,0.315"head diameter X 1-1/4"long' ,' ribbed bugle head screw('or screw shall have at least 3 full threads penetrating metal f framing);the fasteners shall be spaced at 6"O.C.at panel edges and intermediate studs;the 1` fasteners shall be driven into metal studs located at 16"O.C. Fasteners shall have a minimum edge distance of 3/8"and a minimum clearance of 2"from corners. / HARDIESOFFIT,CEMSOFFIT PANEL \\� ✓/ INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc: 20ga,3-5/8"X 1-518"Metal C-stud 10901 Elm Avenue The wall and soffit frames are to be , Fontana, CA 92337 designed by the Architect or Engineer Phone:909-356-6300 SIZE FSCM NO DWG NO REV • of Record in compliance with the Fax 909-427-0634. _ A PNL-PLK-SOFF 2 Florida Building Code. SHEET 11 OF 12 Creator: E.Gonzales SCALE 1/2"=1'-0" Date:9/29/2020 ,� r�. .. _ _, , _ � � .f .. ,. �.:,, wm , ��:,�- �: �;, �� , .. w 5 � � '.3� 1 6.00in. 16.00in., Cladding • ~�'`�--ti Framing l 6.00in. 1 ' I • 4 1 PRODUCT REVISED as complying with the Florida " Building Code NOA-No. 20-0730.06 Expiration Date 05/0112022 By Miami-Dade Product Control \, �,��, °��i1 J�l fA 2 • ;= exn FJ No , ui• ,I _. $TAii✓Of W FLOR�OA' �� ShO,fAt- FRAMING, _ NOMINAL 20 GAUGE 3-5/8"X 1-5/8"STEEL STUDS 16"O.C. . FASTENED WITH 5/8"WAFER HEAD SCREWS(2 PER TOP FOR METAL AND WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE AND BOTTOM-CONNECTION) NOT PART OF THIS APPROVAL(MUST-PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) W THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN ! - COMPLIANCE WITH-THE FLORIDA BUILDING CODE - CLADDING HARDIESOFFIT,CEMSOFFIT PANEL THE SOFFIT IS FASTENED WITH NO.B-18,0.315"HEAD INSTALLATION.DETAILS METAL STUD CONSTRUCTION DIAMETER X 1-1/4"LONG CORROSION RESISTANT RIBBED' BUGLE HEAD SCREWS(SCREW SHALL HAVE AT LEAST 3 FULL THREADS PENETRATING THE METAL FRAMING),PLACE James Hardie Building Products,Inc. SCREWS 6"O.C.AT PANEL EDGES AND INTERMEDIATE' 10901 Elm Avenue Fontana CA 92337 STUDS' Phone:909-356-6300 SIZE FSCM NO DWG NO REV Fax 909-427-0634 A PNL-PLK-SOFF 9 1 I Creator:E.Gonzales SCALE 1'�,'J•':0"`- Date:9/29/2020 SHEET 12 OF 12 i -- � = —=� � / �� s r ,, ��� �. � - ,�� - ,, _ _ ��;� � . . �- _ � . _ - � ��� V � � � � -. �—