Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - ROOFING UNDERLAYMENT8/2/2021 Florida Building Code Online Professional Regulation F �* 13CIS Home I Log In I User Registration I Hot Topics Submit Surcharge r Stats & Facts Publications I Contact Us ; BCIS Site Map If Links 1 Search b � Product Approval q USER: Public User Product App oval Menu > Product or Application Search � ARprc ion List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL2569-R22 Revision 2020 Approved Sopremar Inc, (Canada) 1640 rue Haggarty Drummondville, NON -US 00000 (819)478-2400 memathieu @scprema.ca Marc -Etienne Mathieu memathieu@soprema.ca Marc -Etienne Mathieu 1688 Jean-Berchmans-Michaud Drummondville, NON -US 00000 (819) 478-2400 Ext3327 memathieu @soprema.ca Jean -Francois Cote, Ph.D. 1640 rue Haggerty Drummondville (888)811-3145 jfcote@soprema.ca Roofing Underlayments q C-5 Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert J. M, Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/21/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence F 2569 R2 OI 2 21 01 COI NI MJNEN,pdf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D4601 2012 ASTM D4798 2011 FM 4474 2011 FRSA/TRI Sixth Edition 2018 TA-5 103 2020 UL1897 2015 https:/lfloridabuilding.org/p ripr_app_dtl, aspx? param=wGEVXQwtDgsKQFEnckB 108E rx1 Ud3xYlr7amGvvoArgg kU4EylLatg%3d %3d 1 /2 8/2/2021 Equivalence of Product Standards Certified By Florida Building Code Online rJ Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised SrirnmAry of Prnrimtrfe Method 1 option ❑ 04/19/2021 04/19/2021 04/26/2021 06/08/2021 07/29/2021 FL # Model, Number or Name Description 2569.1 Soprema Roof Underlayments for Self adhering roof underlayments use in FBC HVHZ jurisdictions Limits of Use I Installation Instructions Approved for use in HVHZ: Yes FL2569 R22 II 2021 04 19 FINAL ER SOPREMA HVHZ FL2569- R22.pdf Approved for use outside HVHZ; No Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use. Evaluation Reports FL 5 K2Z A 24 1 04 9 FINAL R SOPREMA HVHZ FL2569- R22.pdf Created by Independent Third Party: Yes 2569.2 Soprema Roof Underlayments for Self adhering roof underlayments use in FBC non-HVHZ jurisdictions Limits of Use Installation Instructions Approved for use in HVHZ: No FL2569 R22 II 2021 04 19 FINAL ER SOPREMA NON - HVHZ FL2569-R22.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen, P.E. PE-59166 Design Pressure: +N/A/-150 Created by Independent Third Party: Yes Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) Evaluation Reports The design pressure noted herein pertains to FL2569 R27 AF 2021 04 19 FINAL ER SOPREMA NON- HVHZ FL2569-R22.pdf underlayment systems used beneath adhesive -set We systems. Refer to ER Section 5.8.3 for details. Created by Independent Third Party: Yes Contact Us :: 2601 Biair Stone Road, Tallahassee FL 32399 Phone: 850-467-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Prlvary Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are publ fc records. If you do not want your e-mail address reieased in response to a publfc-records request, do not send electronic mail to this entity. instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2022, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which car be made available to the pubt[c. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: gCi Credit; Card Safe https://floridabuilding.org/prlpr_app_dtl.aspx7param=wGEVXQwtDgsKOFEnckBI08Erx1Ud3xYlr7amGvvoArggkU4EylLatg%3d%3d 212 NEMOI etc. Certificate of Authorwation 432455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT DLLIATION RFPnP SOPREMA, Inc. Evaluation Report 3m-SOPC-2I-FBCER.A 1640 rue Haggerty FL2569-R22 (HVHZ) Drummondville, Qu6bec 12C 5P8 Canada Date of Issuance.• 04/19/2021 (819) 478-2400 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 7t" Edition Q020) Florida Building Code, High Velocity Hurricane Zone sections noted herein. DESCRIPTION: SOPREMA Roof Underlayments for use in FBC HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7 Prepared by: Robert J.M. Nieminen, P.E. The facsimile seal appearing was authorized by Robert Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 on 04/19/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: I. NEMO ETC, LLC does not have, nor does it intend to acquire or with it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. 'Neither NEVIO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. C2019 NEMO ETC, LLC OMEMO I etc. ROOFING COMPONENT EVALUATION: SCOPE:1. Product Category: Roofing Sub -Category: Underlayment Compliance Statement: SOPREMA Roof Underlayments, as produced by SOPREMA, Inc., have demonstrated compliance with the fallowing sections of the 7`h Edition (2020) Florida Building Code, High Velocity Hurricane Zone through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Sectiori Property Standard Year TAS 110 Material standard ASTM D1970 2015 TAS 110 Material standard ASTM D4601 2012 TAS 110 Material standard TAS 103 2020 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entit Examination Reference Date ERD (TST6049) TAS 103 (MS) 543530.02.14-1-R1 02/21/2014 ERD (TST6049) ASTM D1970 (QC) S44870.04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (OH) S44870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (MS) 544870.04,14-4 04/10/2014 ERD (TST6049) ASTM D1970 (OH) S40540,10.14 10/31/2014 ERD (TST6049) Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) ASTM D4798 SOPC-SC8520.04.14 04/27/2015 N E M 0 (TST6049) ASTM D1970/TAS 110 (QC) SOPC-SC8970.08.15-RI 04/25/2018 NEMO (TST6049) Tile Slippage 4S-SOPC-18-002.09.18 09/21/2018 NEMO (TST6049) ASTM D4601 (MS) 4q-SOP-I9-5SM1313-01.A 03/11/2019 NEMO (TST6049) ASTM D4601 (OH) 4q-SOP-I9-SSMBB-01.B 03/11/2019 NEMO (TST6049) ASTM D4798/D1970 (OH & MS) 4S-SOPC--18-002.05.19.A 05/31/2019 NEW (TST6049) Tensile Adhesion / Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020 NEMO (TST6049) Peel adhesion (existing underlayments) 4j-SOPC-20-SSUDL-01.A 01/07/2021 NEMO (TST6049) ASTM D1970 (MS) 4j-SOPC-2I-SSUDL-01.A 04/19/2021 PRI (TST5878) ASTM D1970 (MS) SOP-064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control MLA File No. R16814 12/10/2015 UL, LLC (QUA9625) Quality Control MLA File No. R27605 05/08/2019 UL, LLC (QUA9625) Quality Control Service Confirmation 06/29/2020 UL, LLC (QUA9625) Quality Control Florida BCIS Current 4.1 4.2 4.3 4.4 PRODUCT DESCRIPTION'. Product Material Standard Plant(s) Description LASTOBOND TU HT ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric surfaced, SBS TAS 103 modified bitumen roof underlayment Tri-Built S/A HT TU ASTM D1970 and Gulfport, MS self adhering, non -woven polyester fabric surfaced, SBS Underlayment TAS 103 modified bitumen roof underlayment LASTOBOND Shield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch RESISTO SA SMOOTH PLY 40 ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment NEMO ETC, U.C. Evaluation Report 3m-SOPC-2I-FBCER.A Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL2569-R22 {HVH2) SOPREMA Roof Underlayments Revision 0: 04/19/2021 Page 2 of 7 M 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 14NEM01eft PRODUCT Product Material Standard Plant ) Description LASTOBOND Shield HT ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment LASTOBOND Pro HT-N ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, 565 modified bitumen roof underlayment available in two widths; 36 and 45 inch LASTOBOND Pro HT-S ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment EnviroShield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment LASTOBOND Eco ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH LASTOBOND Smooth Seal HT ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Wadsworth, OH modified bitumen roof underlayment Tri-Built Smooth HT S/A ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Underlayment Wadsworth, OH modified bitumen roof underlayment PrimeSource Grip -Rite ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Smooth Seal HT Wadsworth, OH modified bitumen roof underlayment RESISTO LB1236 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH TRI-BUILT Sand-R SA Shingle ASTM D1970 Drummondville, QC self adhering, glass -mat reinforced, sand -surfaced, SBS Underlayment Gulfport, MS modified bitumen roof underlayment Wadsworth, OH PrimeSource Grip -Rite Eave ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS & Valley Protector Gulfport, MS modified bitumen roof underlayment Wadsworth, OH SRS TopShield ICE & WATER ASTM D1970 Drummondville, QC self adhering, glass -mat reinforced, sand -surfaced, SBS DEFENDER Gulfport, MS modified bitumen roof underlayment Wadsworth, OH RESISTO LB1244 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH MODIFIED SOPRA-G ASTM D4601, Type II Gulfport, MS Fiberglass reinforced, SBS modified asphaltic base sheet Wadsworth, OH 5. LIMITATIONS: 5.1 This is a Building Code Evaluation, Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FSC Non -High Velocity Hurricane Zone jurisdictions (i.e., outside of Broward and Miami - Dade Counties), 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. NEMO ETC, LLC. Evaluation Report 3m-50PC-21-FBCER.A CertifrcateofAuthoriwtion #32455 7T" EDITION (2020) FBC HVHZ EVALUATION FL2969-R22 (HVH2) SOPREMA Roof Underlayments Revision 0: 04/19/2021 Page 3 of 7 ONEMOjetC. 5.5 SOPREMA Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FUC Section. TAS 110(SIO), RAS 115 TAS 110(511), RAS 118,119 & 120 RAS 133 TAS 110(S11j RAS 130 Clay and Concrete Tile Underlayment Asphalt Shingles Shingles Metal Slate or Slate - Wood Mechanical Adhesive- Attach Set Type Shingles LASTOBOND TU HT, Tri-Built S/A HT TU Yes Underlayment Yes Y Yes See 5.6.1 Yes Yes Yes LASTOBOND Shield, Pro HT-N, RESISTO SA SMOOTH PLY 40 Yes No No Yes Yes Yes LASTOBOND Shield HT, Pro HT-S Yes No No Yes Yes Yes EnviroShiield Yes No No Yes Yes Yes LASTOBOND ECO, RESISTO L91236, TRI- BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, Yes No No No Yes Yes TopShield ICE & WATER DEFENDER, RESISTO LB1244 LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip -Rite Yes No No Yes Yes Yes Smooth Seal HT 5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations. TABLE 1A: ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS' Underlayment Adhesive Florida Product Approval LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment Dupont "Tile BondT' Roof Tile Adhesive" FL22525 ICP Adhesives and Sealants "Polyset® AH-160" NOA 20-1124.07 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Substrates [designed to meet wind loads for projectj Type Printer Material(s) LASTOBOND Shield, LASTOBOND Pro HT-N, Deck ASTM D41 structural concrete RESISTO SA SMOOTH PLY 40, LASTOBOND Dens Deck Prime or SECU ROCK Shield HT, LASTOBOND Pro HT-S, Insulation (Optional) Elastocol Stick Zero EnviroShield, LASTOBOND TU HT, Tri-Built S/A Gypsum -Fiber Roof Board HTTU Underlayment, LASTOBOND ECO, RESISTO L61236, TRI-BUILT Sand-R SA Shingle self- Underlayment, Grip -Rite Eave & Valley adhering Protector, TopShield ICE & WATER Base Sheet (Optional) Elastocol Stick Zero ASTM D226, Type II felt DEFENDER, RESISTO LB1244, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC. Evaluation Report 3m-SOPC-2I-FBCER.A Certificate of Authorization #32455 77H EDITION 12020) FBC HVHZ EVALUATION FL2569-R22 (HVHZ) SOPREMA Roof Underlayments Revision 0: 04/19/2021 Page 4 of 7 *Nwojetc, TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Material(s) LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, RESISTO L61235, TRI-BUILT SExisting sand -surfaced, glass -fiber adhering Sand-R SA Shingle Underlayment, Grip -Rite dh Existing RESISTO EXTERIOR PRIMER surfaced, mineral -surfaced or Eave & Valley Protector or TopShield ICE & ering substrate film -surfaced roof underlayment WATER DEFENDER * Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of on existing substrate to receive LASTOBOND TU HT Tri-Built S/A HT TU Underlayment RESISTO L81236, TRI BUILT Sand-R SA Shingle Underlayment Grip -Rite Eove & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underloyments, contact RESISTO technical support. 5.8 Attachment Limitations: Refer to Section 6 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment LASTOBOND Eco, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244 LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT Prepared Roof Cover Installation Type Maximum Exposure (days) Mechanically attached 30 Mechanically attached 1 90 LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment Mechanically attached or 180 adhesive -set tile roof system SAO Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 10-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Double -tile stacking method, as shown below 6:12 LASTOBOND TU HT, Tri- Built S/A HT TU Underlayment Lugged NEMO ETC, LLC. Evaluation Report 3m-5OPC-2I-FBCER.A Certificate of Authorization #32455 7T" EDITION (2020) FBC HVFIZ EVALUATION FL2569-R22 {HVHZ) SOPREMA Roof Underlayments Revision 0: 04/19/2021 Page 5 of 7 ONEMOIetc. 6.1 SOPREMA Roof Underlayments shall be installed in accordance with SOPREMA published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 A roved Assemblies: 6.3.1 Deck Type 1: Wood, Non -Insulated Beck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type 11 felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment, self -adhering and back -nailed max. 12-inch O.C. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), Surfacing: FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and Table 4 for tile stagging limitations. 6.3.2 Deck Type 1: Wood, Non -Insulated Deck Descrip#ion: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT, self - adhering. Surfacing: FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate -type shingles, wood shakes or wood shingles. 6.3.3 Deck Type 1: Wood, Non -Insulated Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type 11 felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND ECO, RESISTO L81236, TRI-BUILTSand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244, self -adhering. Surfacing: FBC HVHZ Approved asphalt shingles, slate, slate -type shingles, wood shakes or wood shingles. NEW ETC, LLC. Evaluation Report 3m-50PC-2I-FBCER.A Certificate of Authonzativn #i32455 7"' EDITION (2020) FBC HVHZ EVALUATION FL2569-R22 (HVHZ) SOPRENIA Roof Underlayments Revision 0: 04/19/2021 Page 6 of 7 ONEMOjetc. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL LLC—QUA9625; (434) 248-6409; Karen.buchmannCtt�ul.Com - END OF EVALUATION REPORT - MEMO ETC, LLC. Evaluation Report 3m-SOPC-21.FBCER.A Certificate ofAvthorizotion #32455 7"" EDITION (2020) FBC HVHZ EVALUATION FL2569,R22 (HVH2) SOPREMA Roof Underlayments Revision 0: 04/19/2021 Page 7 of 7