Loading...
HomeMy WebLinkAboutST LUCIE WORKS LEVYST. LUCIE WORKS Section A (General Information) Master Permit No. Process No. Contractors Name: =�e�� CI.C'\ -� License # _ (� CC I _�aV 1 � q V Job Address-0 I O S � U9.,'%' Aa. FT Pj e lu � t �3t ! S 1 ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles 1WAsphaltic Shingles ❑ Metal Panel/Shingles Mood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance Ff Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) 5-� Ll Steep Sloped Roof Area (SF) :22GS Total (SF) 3,2NO Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: (; A Notice of Acceptance Number: FL 101 A -R-kQ Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): :Zone 1: ►L1C Zone 2e: �Zone 2nf b- Zone 2r: Zone 3e: Zone 3r: Deck Type: J G� Roof Slope: Type Underiaymenti 12 insulation: t Fire Barrier: Ridge Ventilation? Fastener Type & Spacing: F N A P&A t Ark Adhesive Type: 00 ft7j' Type Cap Sheet:FSP ��� Mean Root Height: Roof Covering: Type & Size Drip Edge: ST. LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: G K F Product Approval No.: t I^ `� 68D-kl3 N0A 1b-11,Db.DL Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Y— Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: Deck: j Type:_ �1�11")Vo Gauge Thickness: Slope: ► ! ) )- Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: 0] Ik -13/k 6A,,--C 1;kee,+ ;�J�. r2-L Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: m l4 SA -AI,2P Skec+ L *,-L � gc('rL[. Top Ply Fastener/Bonding Material: reC'l + .51, c. Ic Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_....." oc @ Lap, # Rows_ ® ° oo Zone 1:—" oc @ Lap, # Rows @ "oo Zone 2:—" oc @ Lap, # Rows @ moo Zone 3:—" oc @ Lap, # Rows— @ "oo Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16..