Loading...
HomeMy WebLinkAboutProduct Approval (3) RECEIVED M IAM I• NOV 2 9 2021 MM MI—DARE COUNTY,FLORIDA ME* PRODUCT CONTROL SECTION ot.Luci ounty DEPARTMENT OF REGULATORY AND ECONOMIC R:iic ESFI�no 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION � (j� Z(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) i�.miamidade.Qov/economy CGI WINDOWS and DOORS,INC. 3780 W. 1041'Street I'�1� COS®E ® iPLIARJCI� Hialeah,FL 33018 ST. L. CIE CO UN�Y SCOPE: �E3lu This NOA is being issued under the applicable rules and Ons"governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series"HR120-Sentinel'Aluminum Horizontal Sliding Window-L.M.I. APPROVAL DOCUMENT: Drawing No. HR 120LM-NOA Rev A(former W10-18), titled"Series 120 Alum. Horizontal Sliding Window-LM", sheets 1 through 14 of 14, dated 06/03/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P. E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with an section of this NOA shall be cause for termination and removal of p y y NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may,be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA No. 17-0918.09 and consists of this page 1 and evidence pages E-1, E-2, E-3, E-4 and E-5,as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq 1.Chanda,P.E. NOA No.20-0610.03 MIAM4DADE COUNTY NOW �. Inc L�q h Expiration Date: September 22,2025 Approval Date: September 10,2020 Page 1 CGI Windows &Doors.Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA's No.'s 10-0510.12 and 15-0512.05) 2. Drawing No. W10-18, titled "Series Sentinel 120 Alum Horiz. Sliding Wdw.-(L.M.I./ S.M.I.)", sheets 1, 1.1, 2, 2.1, 3, 3.1, 4 through 11 of 11, dated 03/29/10 with revision "G" dated 05/02/16, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad,P.E. B. TESTS 1. Test reports on: 1)Air Infiltration Test,per FBC, TAS 201-94 2) Uniform Static Air Pressure Test,Loading per FBC, TAS 202-94 3) Water Resistance Test,per FBC, TAS 202-94 4) Large Missile Impact Test, per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading, per FBC, TAS 203-94 6) Forced Entry Test,FBC 2411 3.2.1, TAS 202-94 along with marked-up drawings and installation diagram of a series Sentinel 120 aluminum horizontal sliding window, prepared by Certified Test Laboratories, Test Report No. CTLA- 3062W, dated 07/07/15, signed and sealed by Ramesh C. Patel,P.E. 2. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 2) Large Missile Impact Test,per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading,per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a series fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WA, dated 03/03/15,signed and sealed by Ramesh C. Patel,P.E. (Submitted under previous NOA No. 15-0512.05) 3. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 2) Large Missile Impact Test, per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading,per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a series project out window, to qualify DuPont `Butacite PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel,P.E. (Submitted under previous NOA No. 15-0512.05). 4. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 2) Large Missile Impact Test, per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading, per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a series aluminum fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA- 3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel,P.E. (Submitted under previous NOA No. 15-0512.05) Ishaq I.Chanda,P.E. Product Control Unit Supervisor NOA No.20-0610.03 Expiration Date: September 22,2025 Approval Date: September 10,2020 E-1 CGI Windows &Doors,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 5. Test reports on: 1)Air Infiltration Test, per FBC, TAS 201-94 2) Uniform Static Air Pressure Test,Loading per FBC,,TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Small Missile Impact Test, per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading, per FBC, TAS 203-94 6) Forced Entry Test, FBC 2411 3.2.1, TAS 202-94 along with marked-up drawings and installation diagram of a series "Sentinel" aluminum horizontal sliding window,prepared by Hurricane Test Laboratory,LLC, Test Report No. HTL-0080-0102-10, dated 06/04/10, signed and sealed by Vinu J. Abraham, P. E. (Submitted under NOA No. 10-0510.12) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 51 Edition (2014), prepared by Al-Farooq Corporation, dated 09/17/15 revised on 05/11/16, signed and sealed by Javad Ahmad,P. E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.10 issued to Kuraray America,Inc. for their "Butacite©PVB Glass Interlayer" dated 04/25/15, expiring on 12/11/16. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America,Inc. for their "SentryGlas® (Clear and White) Glass Interlayers", expiring on 07/04/18. 3. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company(MA)for their"Saflex CP-Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 06/19/14, expiring on 12/11/18. 4. Notice of Acceptance No. 14-0423.17 issued to Eastman Chemical Company(MA) for their"Saflex Clear and Color Glass'Interlayers", expiring on 05/21/16. F. STATEMENTS 1. Statement letter of conformance, of complying with FBC 51h Edition (2014) and of no financial interest, dated 08/17/15, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad,P. E. 2. Laboratory compliance letters for Test Report No. CTLA-3062W, dated 07/07/15, issued by Certified Test Laboratories, signed and sealed by Ramesh C. Patel,P. E. 3. Testing Proposal issued by the Product Control Section, dated 04/08/15, signed by Jaime Gascon,P.E., Section Supervisor. 4. Laboratory compliance letters for Test Reports No.'s CTLA-3056 WA, dated 03/03/15, CTLA-3056 WB, dated 03/03/15 and CTLA-3056 WC, dated 04/16/15, all issued by Certified Test Laboratories, all signed and sealed by Ramesh C. Patel,P. E. (Submitted under previous NOA No. I5-0512.05) Lone lshaq I.Chanda,P.E. Product Control Unit Supervisor NOA No.20-0610.03 Expiration Date: September 22,2025 Approval Date: September 10,2020 E-2 CGI Windows &Doors,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS (CONTINUED) 5. Testing Proposal issued by the Product Control Section, dated 12/16/14, signed by Jaime Gascon,P. E., Section Supervisor. (Submitted under previous NOA No. 15-0512.05) 6. Laboratory compliance letters for Test Report No. HTL-0080-0102-10, issued by Hurricane Test Laboratory, LLC, dated 06/04/10, signed and sealed by Vinu J. Abraham, P. E. (Submitted under NOA No. 10-0510.12) G. OTHERS 1. Notice of Acceptance No. 15-0512.05, issued to CGI Windows & Doors for their Series "Sentinel 120" Aluminum Horizontal Sliding Window — L.M.I., approved on 08/20/15 and expiring on 09/22/20. 2. EVIDENCE SUBMITTED UNDER PREVIOUS NOA A. DRAWINGS 1. Drawing No. W10-18, titled "Series Sentinel 120 Alum Horiz. Sliding Wdw. (L.M.I./ S.M.I.)", sheets 1, 1.1, 2, 2.1, 3, 3.1, 4 through 11 of 11, dated 03/29/10 with revision "H" dated 09/05/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad,P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America,Inc. for their "Trosifol®Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/19/17, expiring on 07/08/19. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America,Inc. for their "SentryGlas® (Clear and White)Interlayer" dated 06/25/15, expiring on 07/04/18. 3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company(MA) for their"Saflex CP-Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/17, expiring on 12/11/18. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company(MA)for their"Saflex Clear and Color Glass Interlayers"dated 09/07/17, expiring on 05/21/21. lshaq 1.Chanda,P.E. Product Control Unit Supervisor NOA No.20-0610.03 Expiration Date: September 22,2025 Approval Date:, September 10,2020 E-3 CGI Windows &Doors,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance to FBC 51" Edition (2014) and FBC 61 Edition (2017), dated 08/30/17, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad,P. E. G. OTHERS 1. This NOA revises NOA 915-0929.13, expiring on 09/22/20. 3. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. HR 120LM-NOA Rev A (former W10-18), titled "Series 120 Alum. Horizontal Sliding Window-LM", sheets 1 through 14 of 14, dated 06/03/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P. E. B. TESTS 1. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC, TAS 202-94 3)Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6)Forced Entry Test,.per ASTM F588 and TAS 202-94 along with marked-up drawings and installation diagram of all CGI Windows and Doors,Inc. and PGT Industries,Inc., representative units listed below and tested to qualify Dowsil 791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window(unit 1 in proposal)FTL-20- 2108.2, CGI CA238 Alum. Outswing Casement Window(unit 2 in proposal)FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door(unit 3 in proposal) FTIr20-2108.4, CGI PW410 Aluminum Fixed Window(unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window(unit 5 in proposal)all dated 08/24/20 and signed and sealed by Idalmis Ortega,P.E. PGT Industries,Inc. test specimens: FTL-7897,PGT PW5520 PVC Fixed Window(unit 6 in proposal), dated 09/03/14 FTL-20-2107.1,PGT SGD780 Aluminum Sliding Glass Door(unit 7 in proposal)FTL-20- 2107.2,PGT CA740 Alum. Outswing Casement Window(unit 8 in proposal)FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window(unit 9 in proposal) and FTL-20-2107.4,PGT PW7620A Aluminum Fixed Window(unit 10 in proposal) all dated 07/13/20 and signed and sealed by Idalmis Ortega,P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 71 Edition (2020), dated 03/26/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. 2. Glazing complies with ASTM E1300-04,-09,-12 and -16.. Ishaq I.Chanda,P.E. Product Control Unit Supervisor NOA No.20-0610.03 Expiration Date: September 22,2025 Approval Date: September 10,2020 E-4 CGI Windows &Doors,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 3. NEW EVIDENCE Continue: D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 19-0305.02 issued to Kuraray America,Inc. for their"Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers", expiring on 07/08/24. 2. Notice of Acceptance No. 17-0808.02 issued to Kuraray America,Inc. for their "SentryGlas® (Clear and White) Glass Interlayers", expiring on 07/04/23. 3. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company(MA) for their"Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. 4. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company(MA) for their"Saflex CP-Saflex and Saflex HP Composite Glass Interlayers with PET Core", expiring on 12/11/23. F. STATEMENTS 1. Statement letters of conformance to FBC 2020(7th Edition), dated 03/26/20, prepared, signed &sealed by Lynn Miller,P. E. 2. Statement from Successor Engineer, adopting another Engineer's work as his own per FLA 51G915.27-001, signed and sealed on 06/03/20 by Anthony Lynn Miller,P.E. 3. Statement of Lab compliance as part of the test report. G. OTHER 1. This NOA revises and renews NOA No. 17-0918.09 and updates to FBC 2020 (7`, Edition) expiring 09/22/25. 2. RER Test proposals #19-1155 dated 01/10/20 approved by Ishaq I. Chanda,P.E. Ishaq I.Chanda,P.E. Product Control Unit Supervisor NOA No.20-0610.03 Expiration Date: September 22,2025 Approval Date: September 10,2020 E-5 TYPICAL ELEVATION. 1/3-1/3-1/3 XOX CONFIGURATION 111• � 110' �g FLANGE WIDTH ZO BUCK WIDTH ¢ 5'MAX.NP. 5 5" MAX.TYP. 6• A C MTG, STILES 10 In LL I Al MTG.STILES .-m PRODUCT REVISED II II II I� as complying with the Florida Building Code E F F E7 F F NOA-No. 20-0610.03 9 s II 9 to 9 9 Expiration Date:09/2212025 44" /. /. '% Miami-Dade Product Control 63 x n4 m u� ,o II m n c II REVISED FOR 2020 FBC, > 'm ADDED ANCHOR TYPE 8, II I I II II REFORMATTED-JR- f 5/29/20 8 1 8 II iV� 901 1 II Q / ZPAT �/FALSE MUNTINS FALSE MUNONS O Q 32 7 8• DDL ANCHOR REDO. ADDL ANCHOR REOD. o_ N(SURFACE APPUED) 32 7/8" SURFACE APPUED 32 7 8" 32 7 8^ ,om h O D.L OPG. CENTER OF ALL PANELS ( ) AT CENTER OF ALL PANELS W m o O z OPTIONAL D.L. OPG. FILED OR OPERABLE OPTIONAL D.L OPG. D.L OPG. FD(ED OR OPERABLE uuzll 36 3 ABOVE 30'PANEL WIDTHS ABOVE 30'PANEL WIDTHS 2 d VENT WID1H AT HEAD/SILL 36 3/6- AT HEAD/SILL z❑ Z 1 N VENT WIDTH }^ Z. uxo�p FLANGE & FLANGE ADAPTOR FRAME EQUAL LEG FRAME ¢off _ } �ZE'� —y0, 'uUU6 W O 1 0• LAMINATED GLASS a� e z o BUCK WIDTH 1.51 THESE WINDOWS ARE RATED FOR LARGE INSULATING LAM. GLASS a^i 5 1/2'MIUC. 13 5 16'MAX. w & SMALL MISSILE IMPACT. SHUTTERS ARE — s^ NOT REQUIRED. LARGE MISSILE IMPACT o z 1°°4S H SILL MTG. STILES Eau SILL SMALL MISSILE IMPACT y F E z a Gt Z SERIES `SENTINEL 1200' ALUMINUM HORIZONTAL ROLLER �PINDO�V ti z oW N z W DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEETS 3-6. v .m 0 Q z APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF H.R./H.R. OR E 3 C 9. = w z HORIZONTAL ROLLING WITH OTHER WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS —3 ,q ~O y �E % // USING MIAMI—DADE COUNTY APPROVED CLIPPED MULLIONS IN BETWEEN. LOWER DESIGN z^ z An N a a a �'1% PRESSURE FROM WINDOWS OR MU WON APPROVAL WILL APPLY TO ENTIRE SYSTEM. o Q ¢ Z N THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH 1b 1°o II �I EDITION)/2020 (7TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). °OU -asap seNaS m = 1BY OR 2BY WOOD BUCKS &BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED IIII ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ,-��\A•j`L,I,N11,/���7i� ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S ��`� . '•.� 2 19 II � INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SMALL.BE BEYOND WALL DRESSING OR STUCCO. �4'�.• 1,LCEN SF • 17 A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ' No.56705 ALL SHIMS TO BE HIGH IMPACT, NON—METALUC AND NON—COMPRESSIBLE — i� FALSE MUNTINS MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS,THAT COME INTO CONTACT WITH OTHER _ J LDISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BUILDING CODE& 3 O � (SURFACE APPLIED)TIONAL 32 7/6' 32 7/8' ADDPTED STANDARDS. ��� ST E P :•-(V�` D.L. OPG. D.L.OPG. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE WFORMATION FOR A SITE SPECIFIC PROJECT, i�� '•.FLORIDP.•' 36 3/8^ I.e. LIFE SAFETY OF THIS PRODUCT,ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING �i�S AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE ��IONAL• FIN FRAME LEN� vExr WIDTH TO BE ANALYZED SEPARATELY, AND TO BE RENEWED BY BUILDING OFFICIAL �/ L` A LYNN MILLER,P.E P.E#58705 r TYPICA ELEIATIQtI, 1 4-1 — 4 XOX CO FIGURA ON nt" � ttD" FLANGE WIDTH o BUCK WIDTH o 6'MAX. 5' MAX.TYP. U 5 1/2"MAX. 5'MAX.TILES TYP_ N U A 0 MTG. STILES w m SI At MTG.S m SI g g PRODUCT REVISED E II F II I F II Et II F II I F �I as complying with the Florida Building Code e NOA-No. 20.0610.03 9 Expiration Date:09122/2025 M= S2 CS= no II II II II w M 13 n II II II II- Mlaml-Dade Product Control �w N N4 B D 6 B t N A t t ��'"•. N Y Q � J��AT _FALSE MUNTINS FALSE MUNTINS 024 1 2' DL ANCHOR REOD. 24 t AODL ANCHOR READ. `l(SURFACE APPLIED) 49 5/8" CENLER OF ALL PANELS (SURFACE APPLIED) 49 5/6" z CA OPTIONALGPTIONAL D.L OPG. w p Oz D.L OPG. ED OR OPERABLE 0 P N mW. 28' ABOVE R PANEL WIDTHS 29" D.L OPG. FlXED OR OPERABLE W a1W VENT WIDTH ABOVE 30"PANEL WIDTHS > AT HEAD/SILL VENT WIDTH AT HEAD/SILL zZ z .rg N J.1n U uMo FLANGE & FLANGE ADAPTOR FRAME EQUAL LEG FRAME 1°1 r _ m pro oN _LL 0 9MO ; '• R i wood a: 0 LAMINATED GLASS LL 0 BUCK WIDTH I FOR LARGE INSULATING LAM. GLASS o & SMALL MISSILE IMPACT. SHUTTERS ARE N 5 1/2"M. 5'MAX P. 13 15 16"MAX. . NOT REQUIRED. LARGE MISSILE IMPACT Z su MTG.STILES SI I SMALL MISSILE IMPACT H aFs A o z Q F Z Ll ally c t z c5 awas z E2 II F I� II F II ¢o S. � LU A — — 9 —II— ace Imo = Z Z E3 3 z w p , o S Q >¢ N 10 " M.J II II Sms in � K m III II w = 1_L � o➢ly •,sap sa��a5 7` 616 140.587O5 ' FALSE MUNIINS 24 t 2" ( �' 0 �" (SURFACE APPLIED) D.L.OPG. 49 5/B" ��:� W� OPTIONAL 2B" D.L. OPG. '�O�(C•••.;�CORIDP VENT wIDTH FIN FRAME /�'SiS��NALLE�C`�� A.LYNN'MILLER,P.E. P.E#58705 DESIGN LOAD CAPACITY - PSF DESIGN LOAD CAPACITY- PSF (XO OR o%SMS) (XOX SIZES) STD.MIU.RAM B.D.Mrc.RAIL STD.UN.RAIL B.D.MIG.RAM B.n.MrG.RAM FLANGE DIMS. BUCK DAIS. CUSS TyPBB mm Tym FLANGE DAffi. BUCK DALE. GLASS TYPES G=TYM CIA 93 nM YWAI', B'&B1' 'B'k'BI' 'A SM.'B'k'BI' 'B'a•'Bt' 'C&'ci' WIDTH HEIGHT WIDTH HEIGHT EKT.(+) INT.(-) EXt.(+) Nr.(-) WIDTH HEIGHT WIDTH HEIGHT ExT.(+) ANT.(-) ExT.(+) ANT.(-) Exr.(+) INr.(-) 26-1/2" 25-1/2' 65.0 65.0 80.0 90.0 55-3/4' 54-3/4' 65.0 65.0 80.0 90.0 65.0 65.0 1" 2V 35' 1, 65.0 65.0 80.0 90.0 78-15/16' 26' 77-15/16" 25' 65.0 65.0 80.0 90.0 65.0 65.0 53-1/8' 52-1/8' 65.0 65.0 80.0 90.0 83-1/2' 82-1/2" 65.0 65.0 80.0 90.0 65.0 65.0 74' 73' 65.0 65.0 80.0 90.0 55-3/4' 54-3/4" 65.0 65.0 80.0 90.0 65.0 65.0 26-1/2" 25-1/2' 65.0 65.0 80.0 90.0 78-15/16' 38-3/8'77-15/16'37-3/8" 65.0 05.0 80.0 90.0 65.0 65.0 37` 36" 65.0 65.0 E0.0 90.0 83-1/2' 82-1/2" 65.0 65.0 80.0 90.0 65.0 65.0 53-1/8' 38-3/8" 52-1/8' 37-3/8' 65.0 65.0 80.0 90.0 55-3/4' 54-3/4' 65.0 65.0 80.0 90.0 65.0 65.0 74' 73" 65.0 65.0 80.0 90.0 78-15/16' 7-15/16"49-5/8' - - - - 65.0. 65.0 a 26-1/2" 25-1/2' 65.0. 65.0 80.0 90.0 83-1/2' 50-5/B"7 82-1/2' - - - - 65,0 65.0a; 37' 50-5/8' 36" 65.0. 65.0 80.0 90.0 55-3/4" 54-3/4' 65.0 65.0 80.0 90.0 65.0 65.0 ' 53-1/8" 52 49-5/8 -1/8' 65.0 65.0 80.0 90.0 78-15/16' 63' 77-15/16' 62' - - - - 65.0 65.0 74` 73" 65.0 65.0 80.0 90.0 83-1/2' 82-1/2' - - - - 65,0 65,0 0 26-1/2' 25-1/2' 85.0 65.0 80.0 90.0 62. o U 37' � 36' 65.0 65.0 _80.0 90.0 N nay 53-1/8" 52-1/e` 65.0 65.0 80.0 90.0 m o In z 74' 73" 60.2 60.2 80.0 90.0 PRODUCT REVISEDz o z �e cov 9ui calk dewlth the Florida. N F uMa ...-No. 20-0623.10 m o (1/2W) (1/2W) T f} 1/3 OF THE WINDOW WIDTH Expiration Dateo5/27/202a ' =u; W o c r w ir ❑ T r r 'y z c� OR OX' Mlaml-Dade Product Control O adz 0 z ❑ 1aa45 OPERATING VENTS TO BE 1/2 OF THE WINDOW WIDTH v) to f- 'XO OR OX' y c o J z q vZ, w �011=0� J II'TYP. BUCK DIMS X,TYP. BUCK DIMS BUCK DIMS 3 o W N j Ir U1 LU 00 W a gs4= z �07 N N FLANGE FRAME EQUAL LEG FRAME FLANGE ADAPTOR FRAME a O m g o N w U 7S ❑ _ FLANGE DIMS FLANGE DIMS v alg1 •asap sauag `7111111117/// ()O LYtuNh��.,�� �•.• 1,10CNSE •.���% FLANGE FRAME =>_ Np.5B7D5 FLANGE ADAPTOR FRAME ,QT•.• STATE OF E4 E4 GLASS CAPACITIES ON THIS SHEET ARE EQUAL LEG FRAME '.�s '•FyORIDP.•'G\?.+ BASED ON ASTM E1300-09 (3 SEC. GUSTS) �NAL.E� STD. MTG. RAIL: H.D. MTG, RAIL: AND FLORIDA BUILDING COMMISSION 0. NN i l l 1 I I;P.E DECLARATORY STATEMENT DCA05-DEC-219 LY P.E.MILLE DESIGN LOAD CAPACITY -PSF DESIGN LOAD CAPACITY- PSF (ROX SMS) (%OR SIZES) STD.MTG.RAIL B.D.LTG.RAM STD.UN.RAIL ED.BTG.RAM H.D.MTG.RAIL FLANGE DIMS. DUCE:DUE. CLASS TYPES GUM TYP16 FLANGE DIMS. BUCK DIMS. GIA88 TYP88 GIM TYPE GId99 TIM 'B'&'BI' A'&'Al" B,&w 'B'&'BI, 'C'&'CI' PRODUCT REVISED WIDTH HEIGHT WIDTH HEIGHT W.(+) INL(-) Dm(+) INT.(-) WIDTH HEIGHT WIDTH HEIGHT EXT.(+) INT.(-) EM.(+) INT.(-) EXT.(+) INT.(-) as complying with the Florida Building Code 74' 73' 65.0 65.0 80.0 90.0 74- 73" 65.0 65.0 80.0 90.0 65.0 65.0 NOA-No. 20-0623.10 105-1/4" 26' 105-1/4" 25" 65.0 65.0 Soso 90.0 106-1/4" 26" 105-1/4" 25" 65.0 65.0 80.0 90.0 65.0 65.0 Expiration Date0 612 7/2 0 2 4 111" 110" 65.0 65.0 80.0 90.0 111' 110" 65.0 65.0 80.0 90.0 65.0 65.0 74' 73' 65.0 65.0 00.0 90.0 74' 73" 65.0 65.0 00.0 90.0 55.0 65.0 gy lil.-�.I•Lm".k 106-1/4- 38-3/8' 105-1/4" 37-3/8- 65.0 65.0 80.0 90.0 106-1/4' 38-3/8" 105-1/4' 37-3/6' 65.0 65.0 00.0 90.0 65.0 65.0 1 Miami-Dade Product Control Ill" 110" 65.0 65.0 80.0 90.0 111" 110' 65.0 65.0 80.0 90.0 65.0 65.0 74' 73" 65.0 65.0 80.0 90.0 74' 73" 65.0 65.0 80.0 90.0 65.0 65.0 106-1/4' 50-5/B" 105-1/4- 49-5/8- 65.0 65.0 80.0 90.0 106-1/4" 50-5/8' 105-1/4" 49-5/8- - - - - 65.0 65.0 _ 111' 110' 65.0 65.0 80.0 90.0 111' 110' - - - - 65.0 65.0 74' 73" 65.0 65.0 80.0 90.0 74' 73 65.0 65.0 80.0 90.0 65.0 65.0 108-1/4' 63' 105-1/4- 62' 61.6 61.8 80.0 90.0 106-1/4' 63' 111' 110' 60.0 60.0 80.0 90.0 111' 110 - - - - 65.0 65.0 NS2 Q N � •�aa s N Q (1/ (1/3w) (1/3W) (1/4w) (1/2 (1/4W) m ao0 z �1 Z 3 w O vuwp J y A m OJo y U) aN = o OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH OPERATING VENTS TO BE 1/4 OF THE WINDOW WIDTH z m t1 Oo 9a z z 'XOX' XOX' rr g o a z`. z 0 laays 12 (0 N o Z cmZ N u1 Z LU alaas a 6� O N j J Y!T(P. BUCK DIMS Yt'7YP. BUCK DIMS BUCK DIMS 3a $a V W (1) Z m o roy = W H E3 �LL� aa. w $8 w m m FLANGE FRAME E UAL LEG FRAME FLANGE ADAPTOR FRAME ®0P=s N o r x RANGE DIMS FLANGE DIMS aIID En saua5 ii 111111 UI//// LYNiv *j No.58705 u_ FLANGE FRAME �` 3T OF w; FLANGE ADAPTOR FRAME D : NOTE: 'T�' FCORIOs,.• ��: E4 E4 GLASS CAPACITIES ON THIS SHEET ARE EQUAL LEG FRAME =,"'ss�•••••••'• BASED ON ASTM E1300-09 (3 SEC. GUSTS) ;i/ STD. MTG. RAIL: H.D. MTG. RAIL: AND FLORIDA BUILDING COMMISSION A LYNN MILLER,RE DECLARATORY STATEMENT DCAOS-DEC-219 PE.058705 DESIGN LOAD CAPACITY - PSF DESIGN LOAD CAPACITY - PSF (XO OR OX SIZES) (XOX SIZES) STD.UTG.RAIL 10.KIC.RAIL, STD.MTG.RAM B.D.KTG.RAIL B.D.urG.RAB, BUCK DIMS. GLASS TYPES GUS3 TYPES BUCK DIMS. CLASS TYPES GIAS9 TYPES CLASS TYPES ' "A'A'A . VABt' 'B'&'BI' TVAI',V011' 'B'k'BP T'h TV PRODUCT REVISED WIDTH HEIGHT EXT.(+) INT.(-) DR.(+) INL(-) WIDTH HEIGHT EXT.(+) INT.(-) IXT.(+) INT.(-) W.(+) INT.(-) as complying with the Rorlda Building Code 25-1/2" 65.0 65.0 80.0 80.0 54-3/4' 65.0 65.0 80.0 80.0 65.0 65.0 NOA-No. 20.0623.10 36" 25 65.0 65.0 80.0 80.0 77-15/16' 25" 65.0 65.D 60.0 80.0 65.0 65.0 Expiration Date05/27/2024 52-1/8' 65.0 65.0 80.0 80.0 82-1/2" 65.0 65.0 80.0 90.0 65.0 65.0 By 151,.E I:Lb,cJ 73" 65.0 65.0 80.0 80.0 54-3/4' 65.0 65.0 80.0 80.0 65.0 65.0 Mlaml-Dade Product Control 25-1/2" 65.0 65.0 80.0 80.0 77-15/16' 37-3/8" 65.0 65.0 80.0 60.0 65.0 65.0 36" 65.0 65.0 80.0 80.0 82-1/e 65.0 65.0 80.0 80.0 65.0 65.0 52-1/8' 37-3/8" 65.0 65.0 80.0 80.0 54-3/4" 65.0 65.0 80.0 solo 65.0 65.0 73' 65.0 65.0 80.0 80.0 77-15/16' 49-5/8" - - - - 65.0 65.0 o 25-1/2" 65.0 65.0 80.0 80.0 82-1/2' - - - - 65.0 65.0 36' 49-5/8' 65.0 65.0 80.0 80.0 54-3/4' 65.0 65.0 80.0 80.0 65.0 65.0 52-1/8' 65.0 65.0 00.0 80.0 77-15/16' 82" - - - - 65.0 65.0 73" 65.0 65.0 80.0 80.0 82-1/2' - - - - 65.0 65.0 N Y Q 25-1/2' 65.0 65.0 80.0 80.0 N LN 7aa 36" 6e 65.0 85.0 80.0. 80.0 Ox 5 O QO j 52-1/8' 65.0 65.0 80.0 solo w tO o O Z 73- _ 60.2 60.2 80.0 80.0 (113W) (2/;W) G at,p 0 Z p Z Fg N j}^ 0 g0` IlM°Jp fY (1/2W) 0/20 m 0 N G QPEttATING VENTS TO BE 1/3 OF THE WINDOW WIDTH w x++d w O sn/G ' G U 'XO OR OX' z a z o a�z (, m z OPERATING VENTS TO BE 1/2 OF THE WINDOW WIDTH x°ays J Co 'XO OR OX, o i r {{ z N VI z W a(°°f r 0.S to popcc Orit N J �+o G " 0: In z m o �Nw 2 to BUCK DIMS E 3,$€LL d W c g W ®Sam Q N U.oSC ul K FIN FRAME a61 ro°ap savag \ttttntxtllli �tcENSF••.1��, ES No.58705 FIN FRAME 46 GLASS CAPACITIES ON THIS SHEET ARE %�S F'��R.�P. G��� E4 E4 BASED ON ASTM E1300-09 (3 SEC. GUSTS) 5NALtE��` STD. MTG. RAIL: H.D. MTG. RAIL: AND FLORIDA BUILDING COMMISSION NN NllLLQt,RE STATEMENT DCA05-DEC-219 A LY NNNUL705 DESIGN LOAD CAPACITY - PSF DESIGN LOAD CAPACITY - PSF (KOR SIZES) (XOX SIZES) STD.HTG.BAIL H.D.HTG.BAIL STD.HTG.RAM H.D.HTG.RAIL H.D.HTG.BAIL BUCK DIMS. GLASS.TRW GLASS T'YP6.4 BUCK DIMS. GLASS T'YFS9 GIM TYP® GLASS TYM $'k'LI',VeBl' V k'Bt' 'ACU,'B'k'Bl" V k'81' V k'Cl' PRODUCT REVISED WIDTH HEIGHT EXL(+) INT.(-) EXT.(+) In(-) WIDTH HEGHT ExT.(+) w.(-) EXI.(+) INT.(-) EXr.(+) INT.(-) as complying with the Flarlda 73" 65.0 65.0 90.0 80.0 73- 65.0 65.0 80.0 80.0 65.0 65.0 Building Code NOA-No. 20-0623.10 105-1/4' 25' 85.0 65.0 80.0 80.0 105-1/4' 25' 65.0 65.0 80.0 80.0 66.0 85.0 110' 65.0 65.0 80.0 80.0 110' 65.0 65.0 80.0 80.0 65.0 65.0 Expiration Date05/27/2024 73" 65.0 65.0 80.0 80.0 73" 85.0 65.0 8D.0 60.0 65.0 65.0 By 1.s�;7 I•�/.dJ. 105-1/4" 37-3/8' 65.0 65.0 80.0 80.0 105-1/4' 37-3/8" 65.0 65.0 80.0 80.0 65.0 65.0 Miami-Dade Product Control 110' 65.0 65.0 80.0 80.0 110' 65.0 65.0 BO.0 80.0 65.0 65.0 73" 65.0 65.0 00.0 80.0 73' 65.0 65.0 80.0 60.0 65.0 65.0 105-1/4' 49-5/8' 65.0 ii 65.0 80.0 60.0 105-1/4` 49-5/8' - - - 65.0 65.0 110' 65.0 65.0 80.0 80.0 110' - - - - 85.0 65.0 73- 65.0 65.0 80.0 110.0 73- 65.0 65.0 80.0 80.0 65.0 65.0 105-1/4" 62- 61.6 61.6 80.0 80.0 105-1/4' 62" - - - - 65.0 65.0 110" 60.0 6D.0 80.0 80.0 110' - - - - 65.0 65.0 N Y Q (1/� (1/?w) (1/� (1/4 (1/2 (1/4W) � N C 0 z z } n 0 uMo,p N > zo V1 oN OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH OPERATING VENTS TO BE 1/4 OF THE WINDOW WIDTH LLoLLtt to m o � Sma KOOm K a 'XOX' 'XOX' o 0 Z p 1aaVS (0 to u1 F A o y V Z N t I00a - p) N F Z W a1a's Q N s ec 0 lij N J 06 O�m Z W H BUCK DIMS LL a �S� Q (2LU N o ' � o FIN FRAMLYNIv E aGa �sao sauag . ��V 11111t1(l7T No.58705CA •�� FIN FRAME �, o••. t TTA, OF NOTE: i COFID \ Ea Ea GLASS CAPACITIES ON THIS SHEET ARE '.,S •• G�� BASED ON ASTM E1300-09 (3 SEC. GUSTS) ,/()NAIVE, STD. MTG. RAIL: H.D. MTG. RAIL: AND FLORIDA BUILDING COMMISSION Nill DECLARATORY STATEMENT DCA05-DEC-219 A.LYNN MILLER,P.E. P.Eft 58705 .075"Safiex CP With PEr Core .075'SaFlex CP With PET Core By'Eastman Chemical Co.' By'Eastman Chemical Co.' 'gn 090'SaFlex Clear And Color Glass w .090'SaFlex Clear And Color Glass �' 075'3aflex CP With PET Core sBy Eastman Chemical Co.' g By 'Eastman Chemical Co.' g By'Eastman Chemical Co. m .090 SentryGIC15v ,090"SentryGiasD ¢C .090 SentryGlas® By Kuroray America, Inc. By•Kuraray America, Inc.' By'Kuraray America,Inc.' .090'Trosifol PVB 1 8•HEAT - 1 a'HEAT PRODUCT REVISED / 090'Trosifoi PVB / as complying with the Florida 1/8'ANN. GLASS By'Kuroroy Ameica, Inc.' STRITL'D GLASS By'Kuraray Amelcc, Inc.' STREN'D GLASS Building Code 1/8'ANN. GLASS 1/8'HEAT SfREN'D GLASS 1/13 wDA-No. 20-0623.10'HEAT SfREN'D GLASS Expiration Datep5/27/2024 0 SILICONES: SILICONES: SILICONES! By 1567 1 Z11, 1: z z z _ GE-1903 DOW 797, 899,91 3 DOW 791, 89 128, DOW 791, � � Si Mlaml-Dade Product Control 899, 983,OR 995 899,983,OR 995 899,983,OR 995 \� M1 \� M1 \� Mt ADDED BACKBEDDING TYPES-JR-Sf WO 0 0 0 a E9 E6 FF EB M7 AT 1/4 POINTS ON UrES M7 AT 1/4 POINTS ON LRES 5f M7 AT 1/4 POINTS ON LITES N ¢ WWW WIDER THAN 36' WWW WIDER THAN 36' GGG1 WIDER THAN 36" N 'gab GLASS TYPE 'A' GLASS TYPE I GLASS TYPE 'C' Occ ¢ 5/16'NOMINAL LAM. GLASS 5/1V NOMINAL LAM.GLASS 5/1V NOMINAL LAM.GLASS (L.M.I & S.M.I.) (L.M.I & S.M.I.) o z (L.M.I & S.M.I.) �� H woo Z a z fg N J y^ O uMaO QaF mOo y � roN 1/8"HEAT STREN'D GLASS 1/8-HEAT SIREN'D GLASS W=w_ p 9�da 1/8-ANN. GLASS .075"Safiex CP With PEr Core 075"SaFlex CP With PEr Care g c taJ+ O T By'Eastman Chemical Co.' By 'Eastman Chemical Co.' z 1/4-AIR SPACE a' q .075'Soflex CP With PET Core o Z u' / a: 090"SaFlex Clear And Color Gloss 1/4"AIR SPACE a� .090'Safiex Clear And Color Glass 1/4'AIR SPACE �iL— ¢n � p By'Eastman Chemical Co.' By'Eastman Chemical Co.' g By'Eastman Chemical Co.' a z V, n 1/8-ANN. OR g 090 SeMlyGlas® t/8'HEAT rc 090'SentryGlas® 1/8'HEAT 090"SantryGlas® TEMPERED*GLASS By'Kuraroy America, Inc.' STREN'D OR By'Kuraray America, Inc.' STREN'D OR By'Kuraray America, Inc.' O IoaVs 090"Trosifol PVB TEMPERED-GLASS .G9io Trosifol PV13 TEAL GLASS `o 0 By'Kuroray Ameica, Inc.' By'Kuroray Amelea, Inc.' H�a t z F Z 1/8-ANN. GLASS 1/8"HEAT STREN'D GLASS 1/8-HEAT STREWD GLASS 'in oD I rc Z apas d Sy=OW N -if owe W tm SILICONES: m SILICONES: m SILICONES: m °'ro 'o p ¢ F Z GE-1200, DOW 791, z N GE-1200,DOW 791, z N GE-1200, DOW 791, a p�p�� =n o S 0 Z 899, 983, OR 995 899.983, OR 995 899,983, OR 995 E 3 c g �, ul M7 \ Mt \ Mt S Z o XL EDGE SPACER XL EDGE SPACER XL EDGE SPACER a 2 J ¢ N �,.soit Si.STEEL BY'CARDINAL' ST. STEEL BY'CARDINAL'. SI'.STEEL By'CARDINAL' 0 o.x S C7 = OR OR OR a00 •asap saves a DURASEAL BY'QUANEX' a OURASEAL BY'QUANEX' fL1 DURASEAL BY'QUANEX' OR C OR OR ® SUPER SPACER BY'OUANEW Eg SUPER SPACER BY'QUANEV Eq SUPER SPACER BY'OUANEX' ��•��11Y LYN'ff����, .` ON.......N M7 AT 1/4 POINTS ALL SIZES M7 AT 1/4 POINTS ALL SIZES M7 AT 1/4 POINTS ALL SIZFS `��'��•''�yCEN,pF V GLASS TYPE 'Al' GLASS TYPE '111 GLASS TYPE 'C1' = No.58705 0.70"OVERALL INSUL LAM.GLASS 0.70'OVERALL INSUL LAM.GLASS 0.70"OVERALL INSUL LAM.GLASS = (L.M.I & S.M.I.) (L.M.I & S.M.I.) (L.M.I & S.M.I.) 6 3 Qom` ���•. A OF 70NAL 1EN.`. 'FOR INSULATED GLASS INSTALLATIONS ABOVE 30'IN THE HVHZ, OR FOR SAFELY GLAZING APPLICATIONS PER THE FBC,THE OUTBOARD LITE(CAP) MUST BE TEMPERED. A LYNN MILLER,P.E REA 68705 FLANGE & FLANGE ADAPTOR FRAME Y TYPICAL ANCHORS METAL � � — SEE ELEV. STRUCTURE m _ WOOD BUCK . FOR SEDG OtST. G TYPICAL ANCHORS o G , � "MULLION kE MUWON ANCHORS • ', SEE ELEV. 3 o tD N SEE SEPARATE NOA FOR SPACING e ° EDGE DIST. °4 e n a.' a d� ° e a' � w� PRODUCT REVISED ¢ ¢ _ _ I as eomplying with the Florida „ ••.c EDGE OIST. " va NOA-No.IldIng 20.0623.10 is Expiration Date05/27/2024 By ESL-2.ILb,"k O 1 O i i ®j Mlaml-Dade Product Control ANCHORS ANCHORS TYPICAL ANCHO SEE ELEV. t SEE ELEV. ADDED ANCHOR TYPE& FOR SPACING FOR SPACING E7 � REFORMATTED-JR- 5129120 1 WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WDW. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM 2 3/8"MIN. AND TRANSFER THEM TO THE BUILDING STRUCTURE. N g TYPICAL ANCHORS: SEE ELEV. FOR SPACING a N Q .� 1/4" DIA. ULTRACON BY 'ELCO' (Fu-177 KSI,Fy=155 KSI) �u N aoQ 2-3/S"MIN. INTO 2BY WOOD BUCKS OR WOOD STRUCTURES z E i W N I 'I 1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS) �o o uao,Q TYP. EDGE DISTANCE INTO WOOD STRUCTURE = 1" MIN. doe i _ = THRU 1BY BUCKS INTO CONC. OR CMU OR o0ii� In Orp a Y Y DIRECTLY INTO CONC. OR CMU w� a w 00 o II to1-1/4" MIN. EMBED INiO CONCRETE (HEAD/SILL/JAMBS) ¢ z o Z c Q'' !I I WHEN USED THE MIN'WOOD SUCK c TYP./EDGEIN. /DISTANCE INTO CONCRETE AND CMU = 2-1 2" MIN.EMBED INTO CMU (JAMBS) w Q. z LL DEPTH SHALL BE 23r.THE USE OF Z (1) 00 O DEEPER OR BEVELED WOODBUCKS IS PERMITTED. 1/4" DIA, ULTRACON+ BY 'DEWALT'(Fum164 KSI,Fy=148 KSI) o laays 7�WS! 1 INTO 2BY WOOD BUCKS OR WOOD STRUCTURES U) oco r4 1 1"3 IN. EDGE DISTANCE ON INTO WOOD (HEAD/SILL/JAMBS) y F z z MB 0 THRU 1 BY BUCKS INTO CONC. OR DIRECTLY INTO CONC. 2 3 o w ^I g w 1" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) .o l o R o Q Z 1 F 1-3/4" MIN. EDGE DISTANCE E 3 J m x z z THRU 1 BY BUCKS INTO HOLLOW CMU OR DIRECTLY INTO HOLLOW CMU - $=u w Y) N W w 1-1/4" MIN. EMBED INTO CMU (JAMBS) o ° ¢ z N 1-1/2" MIN. EDGE DISTANCE S O 5 0U m S r S OB O 14 SMS OR SELF DRILLING SCREWS, GRADE 2 CRSI( a11Iy 7saQ saua —� a INTO MIAMI-DADE COUNTY APPROVED MULLIONS (MIN. THK:1/r OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) `11711IIIT��7 (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE \ N`tLYNN,y,��,, '" ^ .g •! s ., •. ALUMINUM • 1/8" THK. MIN. (6063-T5 MIN.) :� •' LICENSE •!� EDGE iST. ,� e• '�a'8 ° STEEL : 1/8" TFIK. MIN. (Fy'= 36 KSI MIN.) • a i YP :1I ANCHORS (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) - No.5B705 ••• 1BY " TYPICAL ANCHORS •'!..•.,•�•. SEE ` W006 BUCK SEE ELEV, .^ FOR SPACING EDGE DIST. TYPICAL EDGE DISTANCE FOR SPACING INTO WOOD STRUCTURE = 1" MIN. �1 •, 6 3.Z0 ::.�` INTO METAL STRUCTURE = 3/4" MIN. O�.• STATE OF (V 7NTALLATION DETAILS SHOWN ON PAGES WEEPHOLES. 8 & 9 APPLY TO BOTH FLANGE FRAME W1 1/4" X 1-1/2" WEEP SLOT AT 4-1/8" FROM EACH END WITH PLASTIC COVER. WOOD AT HEAD. SILL OR JAMBS SG - 0.55 MIN. AL AND FLANGE ADAPTOR FRAMES. W2 = 1/8" X 1/2' WEEP SLOT AT 3-1/8" FROM EACH END. ���/ilill ll�l� W3 = 1/8" X 1/2" WEEP SLOT AT 3-1/8" FROM EACH END. CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN. A LYNN MILLER,P.E C-90 HOLLOW/FILLED NORMAL WEIGHT BLOCK AT JAMBS f'm =2G00 PSI MIN. P.E.n58705 FLANGE & FLANGE ADAPTOR FRAME -MAX. SH1M5 1/4-M. BUCK WIDTH SHIMS INTALLATION DETAILS SHOWN ON PAGES 8 VENT WIDTH VENT WIDTH AND 9 APPLY TO BOTH FLANGE FRAME AND TYPICAL ANCHORS FLANGE ADAPTOR FRAMES. SEE FOR SPAC�1 G O O O PRODUCT REVISED as complying with the Florida 1 1/2' Bu1lding Code 'q• BOA-No. 20-0623.10 Expiration DateOS/27/2024 �o By IsL-7I.L11411. FV�4* FLANGE ADAPTOR FRAME Miami-Dade Product Control 2BY WOOD SCREENS OPTIONAL BUCK OR 1/2'7YP. O WOOD STRUCTUREJ ,BY EXTERIOR 'TYPICAL ANCHORS z WOOD BUCKS D.L OPG. SEE ELEV. XOX LAYOUT FOR SPACING ON S2 MIAMI-DADE COUNTY APPROVED MULLION &MULLION ANCHORS SEE SEPARATE NOA m O BBUCK WIDTH O ALTERNATE BUCK WIDTH w m O z SWEEP LOCK z Iu B�Q K 1 OPTIONAL TO 2 Z 1p Z �g N F271SPRING LOCK Y n O IIMOJQ S6 m O LL o rn 'aN 2 QMQ W U of d K O d�z$ z Z z J OO � lae45 N co O f2 TYPICAL ANCHORS EXTERIOR m o Z ¢ z Z SEE ELEV. FOR SPACING E4 m vi Z e/oag 1/4-MAX. BUCK WIDTH ,/4-MAX. �a o o i9 K Q Z SHIM SHIMS R v ro�n w O 1 VENT WIDTH 3 g LL w x co TYPICAL t O ' O O _ Z.$_ ? W 10 Z. ANCHORS TYPICAL ANCHORS 3 0 Q Z N SEE ELEY. SEE ELEV. t7 f9<M o FOR SPACING T - -1 FOR SPACING C�"_�- 7•! epq •Wrap sauag •,, /4- � ```�,11111111f11rf7 METAL 1 NL NSFy © ` Pam.:. STRUCTURE No.58705 •� SCREENS OPTIONAL .liv 3 a �= EXTERIOR IBY �On., STATE OF (V` E5 WOOD BUCKS p XO AYOUT D.L GPG. ' �,�7`,S/0 L NAL N ff111AL T1� \ A.LYNN MILLER,P.E. P.E.A 58705 I EQUAL LEG FRAME METAL TYPICAL ANCHORS r - STRUCTURE SEE ELEV. H I MIAMI-DACE COUNTY APPROVEO TYPICAL ANCHORS FOR SPACING 30 MULLION &MULLION ANCHORS 15Y WOOD BUCK FOR SPACING EDGE DIST. o DGE \N II SEE SEPARATE NOA EDGE DIST a a 3 r �•: a� _EDGE asr" L - PRODUCT REVISED ' a d; .a A• a - °'• = as complying with the Florida a � BUIltling Cotle NOA-N.. 20.0623.10 v=i Expiration Date05/27/2024 AI 2 1 - TYPICAL ANCHORS �I�CHORS Miami-Dade IDad;I LF,n.a. SEE ' FOR SPACING Mlaml-Dade Product Control FOR SPACING E3 E7 1 TYPICAL ANCHORS SEE ELEV. FOR SPACING 2 3/8-MIN. 1/4-MAX. BUCK WIDTH o SHIMS o N 1 N � •nay o D E1 N N a a 1 \ N o u0 O z 2-3/8*MIN. L° H a1 1-41 1/4'* GW_: [�a N 18 N uuw0 0: \ \ Q O�y 2 oN U : In 0z 2i SAW n to yw.UUd K O o r WHEN USED THE MIN.WOOD BUCK a z< Z LL o DEPTH SHALL BE W.THE USE OF w O o w 1 DEEPER OR BEVELED WOODBUCKS IS a o Z (0 Q o 8 '3 Es EXTERIOR P� o o !sous 1 E7 4 y 0) p y 1 a.'. Y S z -1 Z F MIAMI-DADE COUNTY ab r O -I ales M9 APPROVED MULLION S y 2 O;,y m N F< ;•1 &MULLION ANCHORS 3 Oo y w 1 SEE SEPARATE NOA 2 Z Z 0 0�p� F 1 BUCK WIDTH BUCK WIDTH E j 3 g$I J N E2rn � .n O Cing� O CY 'rQ' B I _ z f � aA1 •asa0 saua5 N Ly Or EDGE OIQ. '�' .• •• .b \ a °•d I I i .•� •�. TYPICAL AACHDRS 1BY SEE ELEV. •'° v • No.58705 'WOOD BUCK FOR SPACING ,• ,•p 'q' °••TYPICAL ANCHORS •'"9 �.\z_• }p ..•.s:. ,• I SEE ELEV. •' CCI` i FOR SPACING TYPICAL ANCHORS %O•'. STjAj0F0 EQUAL LEG FRAME CAN BE INSTALLED DIRECTLY SEE ELEV, FOR SPACING %�F ^"t Op1p P,.•" \�� INTO WO D, CONCRETE OR METAL STRUCTURES ��'!rSK. �()NALWITHOUT1 A,LYNN MILLER,P.E. P.E.#55705 FIN FRAME ILLUSTRATNE DNS.ONLY TYPICAL ANCHORS EXT.OR INT. FINISHES SEE ELEV. NG NOT BY CGI FOR SPACI z PRODUCT REVISED 1 1 1/2• N as complying with the Florlda Building Code BOA-No. 20-0623.10 HOUSE WRAP Expiratlon Date05/27/2024 NOT BY CGI By IStrZ.I.L6,as. A2 2 1 Mlaml-Dade Product Control BAC11 E3 CAULKING 1/4'MAX. BUCK WIDTH 1/4'MAX. GAP GAP 1/2'MIN. 1/2'MIN. 1 --T � WOOD STRUCTU NOT BY CGI 1 b 0 N 0 1 o O z >_ N 50 R' N Z 0_ z fg N f og�m � &AG a m ¢vzm z r p SCREENS OPf. a z v Z LL o py „ , BACKBED o 0 O CAULKING a• Z z HOUSE WRAP E6 EXTERIOR o o ..qs W 1 E7 NOT BY CGI U) Z k dot Z z 5 z Mg Qg�o- N F W .v.~i,m 1 1 E3 =mm = w gg= j 2 E2 TYPICAL ANCHORS:SEE ELEV.FOR SPACING - 3 a Q LL N BACKBED O ti¢o o Z U�Sm CAULKING 48 SMS (Fu=74 KSI MIN.) a� B2 INTO 2BY WOOD BUCKS OR WOOD STRUCTURES eG s. s 1-1/2" MIN. PENETRATION INTO WOOD 111111 HOUSE WRAP ���L11 ll1�i NOT BY CGI ..... 'i,�' No.58705 TYPICAL ANCHORS SEE ELEV. i ••. (�-. �^ FOR SPACAC ING, 01•. STATE OF S;8NtAf L I �. A.LYNN MILLER,P.E. P.E#58705 TCSI[ PART 0 QUANTITY DESCRIPTION WTBBLLL 21ANF./SUPPL.TBB/Bl3mARH9 MATERIAL PROPERTIES: F. E1 CGI-100 - FRAME JAMB O FIXED GLASS 6083-TS CGI EXTRUDER Material Win.sl Min.Isfil #14 Steel ScnN+ 82 ksi E2 CGI-113 - FRAME SILL, 6063-T6 CGI EXTRUDER 1/4"Elco UltmCon 155 ksi E3 CGI-102 - FRAME HEAD 6063-76 CGI EXTRUDER 1/4"DeWalt UIUaCon+ 148 ksl E4 CGI-103 - ME711NG RAIL 6063-T6 CGI fXTRUDER 606'3-T5 Aluminum 16 ksi A35 Steel 35 Its] E5 CGI-104 LOCK RAIL 6063-TS CGI EXTRUDER EG CGI-105 - HANDLE RAIL _ 6063-76 CGI EXTRUDER PRODUCT REVISED E! CCI-106 - SASH RAIL 6063 T6 CGI EXTRUDER as complying with the Florida Building Code Ell CGI-107 - 5/16-GLAZING BEAD 8063-T5 CGI EXTRUDER NOA-No. 20-0623.10 Ell CGI-108 - 0.700'GLAZING BEAD 6063-T5 CGI EXTRUDER E10 CGI-109 - FRONT FIANCE ADAPTOR 6063-T6 CGI EXTRUDER Expiration Date05/27l2024 Ell CGI-110 - NAIL FIN ADAPTOR 6063-T6 CGI EXTRUDER BY 154"1 E Cb,n1` E12 CGI-135 TF FRAME JAMB O FIXED GLASS 6063-T5 CGI EXTRUDER Miami-Dade Product Control E13 CGI-136 - TF FRAME HEAD 6063-T6 CGI EXTRUDER ADDED BACKBEDDING E14 CGI-139 - TF FRAME JAMB 6063-T6 CGI EXTRUDER TYPES-JR-529120 E15 CGI-140 - 1"-MUNON 6063-T5 CGI EXTRUDER N E16 CGI-141 2.5"MULLION 6063-TS CGI EXTRUDER 2 E17 CGI-605 - SCREEN FRAME 6063-T5 CGI EXTRUDER E18 CGI-114 - SILL SNAP IN 6063-T6 CGI EXTRUDER E1g CGI-115 - SILL FILLER 6063-T6 CGI EXTRUDER N Y Q E20 CGI-116 - FRAME JAMB 6063-T6 CGI EXTRUDER N U) •nab E21 CGI-117 - HD LACK RAIL 6063-T6 CGI EXTRUDER Vto Q E22 CGI-138 - IF FRAME SILL 6063-T6 CGI EXTRUDER m p O 2 E23 CGI-109 - FRONT FLANGE ADAPTOR 6063-T6 CGI EXTRUDER j n ato0 zE z o M1 CGI-382V - GLAZING BULB VINYL(OUROMEIER 75-80 SHORE A) Pvc - J N F uMa'0 M2 CGI-Ill - SCREW COVER (OPTIONAL) PVC - d O _ M3 CGI-112 3'O ANCHORS EQUAL LEG COVER/SHIM PVC - 07 z'. m DAfO M4 - 0.700"X 0.040"BEAD GE1200 SILICONE SILICONE GE w u 3 O w r W M5 - 0.700'X 0.040'BEAD DOW 791 OR 899 SILICONE DOW y~o c z LL M6 - 0.700'X 0.040"BD DOW 9 OR 995 SILICONE DOW $ w' O EA 83 M7 2/LITE SETTING BLOCK EPDM DUROMEIER 8015 SHORE A a Z Z MB - - PROTECTO WRAP WATERPROOFING OR EQUIV. - - 8 I0B45 M9 654 - ROLLER TRACK PVC - vJ1 MID CGI-128 2 PER SASH ROLLER HOUSING NYLON - w 0 E z H Mil W23201NG - PILE WITH CENTER FIN WOOL ULTRAFAB OR EQUN. y g M12 CGI-129 1 PER SASH EGRESS LOCK ALUM. SULLIVAN N Q � O M13 CGI-131 2 PER SASH HANDLE RAIL END CAP NYLON M&M i� a O� O Z M14 391-N 1 PER SASH ANDLIFT BLOCK NYLON M&M �• "o = ~ E 5 �� M15 - OPTIONAL RETICULATED FOAM 30 PPI - - LL y MIB CGI-134 - JAMB SPACER PVC PROTOTYPE OR FAUN. e a O N M17 A307304DI-32 1 PER WD. CAM LOCK ZINC TRUTH OR EQUIV.. _� (g�Q` O J M18 CGI-132 2PER WD.2" SASH STOP PVC PROTOTYPE M19 CGI-Ill O FR. HEAD- SCREW COVER PVC PROTOTYPE apl •asa0 sapag M20 CGI-125 2PER SASH SASH CAM (B/T BALANCE) NYLON M&M 1LLL11111 I3//� M22 - VARIES HI-FLO WEEP COVERS PVC AMESBURY OR EQUN +++ t'LYNN S2 - 2 OR 3 PER CORNER 10 X 1 1/4'LG.PHL PH.SUS. ST/ST.ASSEMBLY SCREW - - \��'�,•' LICENSE'•,(� S3 - 1 1/4-EMBED. 8 X 1 1/2-LG.PHL PH.SMS.FIN ANCHOR SCREW S4 - 4 PER WD. 8 X-1/2-PH.SMS.ST/ST BALANCE BRACKET SCREW _ _ NO.58705 S5 2 PER WD. 8 X 1"I.G. FH.SMS. ST/ST.SPIRAL B.ASSEMBLY - - - S6 - - 8 6 X 1/2"LG.FH.SMS.O CGI-133 &CAM LOCK - - �•'•• tA �58 - 4 OM.RAIL $ 10 X 4'LG.PHL PH.SMS. S7/ST.ASSEMBLY MEETING RAIL - - �On •�� S9 - 2 PER ANTIUFr 8 10 X 5/8-I.G.PHL PH.SMS. ST/SL'ANRLIFT SCREW - - %�` F�ORIDP.•'•G,\=� ONAL E +�� A LYNN MILLER•P.E. P.E#58705 2440- 2440 _ 27t3 .065 .120 1.015 IT, ,72.tOt 7.301 �1 1.5Ij50 1.680 2846 O65 1.807 [465 1.220 '-r .864 • 2346 1.007 JJJ.050 .700"GLAZING BEAD PRODUCT REVISED 55 'TMp 1.3 55 B oo'Oplc ngewlth the Florlda id 1449 NOA-No. d 20.0623.10 1.015 t.o75 1.368 .745 E77 NAIL FIN ADAPTER Explratlon oate05/27/2024 Eta FLANGE FRAME HEAD O FLUSH FRAME HEAD E4 MEETING RAIL 2s3 BY 15-9 I. 1.496 Mlaml-Dade Product Control 1.015 1.015 1.788 .060 1.413 1 140 O65 1.140 TYP. '�{I 22s4 '.erg N2 SCREW COVER _ 1.015 El 1.220 .080 O65 ' 4.430 TYR 3.930 065 N Y Q 3.685 2.885 3.185 TYP' 2.885 1.043 N nay rn O LOCK RAIL SILL FILLER m co Et9 Qj Q m o Oa, Z 1.786N a7o0 1.450 z N 160 >0 O uxo10 2.440 .50 .050 m O 5 N 2.44D Z u' 0 � Dma 2.310 WSW W O FLANGE FRAME SILL O FLUSH FRAME SILL 1.0 5 •D 5 tTYP. .22o . W z LL 2737 2737 O FLANGE ADAPTOR a z„ Z r • 1.043 O Plys 065 065 O .490 ` F17 ALT. LOCK RAIL o e z ¢ z z 2.505 2.613 2.5D5 2.613 t.892 •705 I .050 TYP. Z •�s's L +i .864 o F Z 065 a,p y o o = Z Z ;YP. a - ��� t.00D .997 .500 .997 2.195 @ 5/16" GLAZING BEAD -3 $$_ N. j Z) 2737 1.075 � c7 U�S 1.395 FLANGE FRAME JAMB (MOVING) @FLUSH FRAME JAMB (MOVING) 180ally rosa0 ell .911 1.043 L .050 'oN fILYNIV� OHANDLE RAIL M3 ,a'��'.•'`lGE.....flz O FLUSH FRAME COVER 1.025 - 2.505 _ r No.58705 .0.TYP. 2505 .065 TYP. :!t- D ` 1.015 t.015 SiA OF 1.395 ••• T OF 4U� 745 ���•, (V` i Cc '••'ZORIOP..''• 1.000 soo Dss •,'�SI�NF L EG�• t.74s t.24s Lots //tlnllttt Et2 FLANGE FRAME JAMB (FIXED) Et FLUSH FRAME JAMB (FIXED) O SASH RAIL ALYPE#58705'P.E d d' Z 0 n 777 \ N Revision: I I r Impact Resistant,/ ® W ndo s&BOOrS 1070R TECHNOLOGY GY DRIVEBY A.LYNN LLER m r pJ n as-0°mu 0 5. .,1 i iNE' SMONBER- N.VENICE,FL 34275 T - � i g O CGI WINDOW58DOOR5,INC, (941)460-1600 m a P1°sC •p z �� T •ya 3780 W 104TH STREET In Z .�yi`�) e t HMLEAH,FL 33018 REGISTRATION#29296 9 \ 61 N 4 :b n:r- (305)593-6590 oQ n O m g z ^m120 ALUM.HORIZONTAL SLIDING WINDOW(LM) 0 05/29/2020 N N In :2C,'• e\ o CORNER DETAILS om J ROSOWSKI a =0 0 HR120"SENTINEL" NTS N 14 OF 14 oz°HR120LM-NOA A 93