Loading...
HomeMy WebLinkAboutEngineering Opening I Size. 1: FL30505.2 72 x 80' (� (SGD) 2.'-FL15757 T 36 x 37 (CASEMENT) 3, FL16477.1 52 x 49 (HORIZONTAL SLIDER) 4. FL16477.1 52 x 49 (HORIZONTAL SLIDER) 5. FL16477.1 52 x 49 - ) (HORIZONTAL SLIDER) 6, FL16477.1 52 x 49ED '(HORIZONTAL SLIDER) 1 2 DINING KITCHEN v m. ® i c r 'w U D7 � I?61 m .N m N• � N "• 01 d O d K O U .t N 8' d LL GARAGE 45' Q J ONO LIVING BED 1 0 6 5 4 3 UJ � LL c EGRESS U O cN U 5 .. 06 LU ' 7 m B 3a Z J LL ' COPYRIGIIT E•TEMPE9T,COM - SCALE: NOT TO SCALE DATE: Nov 03,2021 PAGE DESCRIPTION: Site Plan 1 l/.e/$ PAGE OP� RECENED N0V 12 2021 STMR - 500&W 12th Ave St.L.udie County Deerfield Beach, FL 33442 Permlttm9 WIN W- S Ph.561,922-6747 Fax.561-292-3562 Property Information Building Information Owner: WILLIAM&KAREN EASON Wind Zone: 170 MPH. Address: 1107 DRIFTWOOD LN Exposure Category: C FT PIERCE,FL 34982 Minimum Building Dimension: 45 ft. Mean Roof Height: 14 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psi Pressure(psf) 1 Int 72 80 7 34.4 -37.6 2 lnt 36 37 7 37.8 -41.0 3 Int-- -- 52 ----- 49-- --- ---7---- --------- 36.4 -39.6 --- ... --- — ---------------------------------- ------------- ——-.....-- ---- _..---- --- - - ---------— --------- 4 Int 52 49 7 36.4 -39.6 5 Int 52 49 7 36.4 -39.6 6 - Int-- -- 52 49 - 7 36.4 -39.6 Prepared in accordance ivith:ASCE 7-16.Chapter 30. PVind Loads-Components and Cladding. %rh Edition(2020)Florida Building Cocle. Page 1 of 1 ® ® e DOOR, OPENING INFORMATION; P A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET z Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,.but not less than 4%of least horizontal dimension or 3 ft. ^' CD PRODUCT APPROVAL REQUIRED OPENING MAXIMU LT[ELE OPENING (Location) IS THIS A PRODUCT ROUGH ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M �NDQW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING NUTTERS TYPE TESTED LLION NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS cE W REQ Y/N SIZE REC�Y/N1NA 1 Int Door I." Lami FL30505.2 50 50 34.4 -37.6 99 x 96 72x80 No No 2 Int Window I"Lami FL15757.1 70 70 37.8 -41.0 37 x 76 36x37 No No 3 Int Window I"Lank FL1.6477.1 55 55 36.4 -39.6 76 x 74 52x49 YES No 4 Int Window I"Lami FL16477.1. 55 55 36.4 -39.6 76 x 74 52x49 YES No 5 Int Window I" Lami FL16477.1 55 55 36.4 -39.6 76 x 74 52x49 YES No 6 Int Window I" Lami FL16477.1 55 55 36.4 -39.6 76 x 74 52x49 YES No