HomeMy WebLinkAboutEngineering Opening I Size.
1: FL30505.2 72 x 80' (�
(SGD)
2.'-FL15757 T 36 x 37
(CASEMENT)
3, FL16477.1 52 x 49
(HORIZONTAL SLIDER)
4. FL16477.1 52 x 49
(HORIZONTAL SLIDER)
5. FL16477.1 52 x 49 - )
(HORIZONTAL SLIDER)
6, FL16477.1 52 x 49ED
'(HORIZONTAL SLIDER)
1 2
DINING KITCHEN v
m.
® i
c r 'w
U
D7 � I?61 m .N
m N• �
N "•
01
d
O d K
O U .t
N 8' d LL
GARAGE
45'
Q J ONO
LIVING BED 1 0
6 5 4 3 UJ
� LL
c
EGRESS U
O cN U 5 ..
06
LU ' 7 m
B 3a
Z J LL
' COPYRIGIIT E•TEMPE9T,COM
- SCALE:
NOT TO SCALE
DATE:
Nov 03,2021
PAGE DESCRIPTION:
Site Plan
1 l/.e/$ PAGE OP�
RECENED
N0V 12 2021 STMR - 500&W 12th Ave
St.L.udie County Deerfield Beach, FL 33442
Permlttm9 WIN
W- S
Ph.561,922-6747
Fax.561-292-3562
Property Information Building Information
Owner: WILLIAM&KAREN EASON Wind Zone: 170 MPH.
Address: 1107 DRIFTWOOD LN Exposure Category: C
FT PIERCE,FL 34982 Minimum Building Dimension: 45 ft.
Mean Roof Height: 14 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psi Pressure(psf)
1 Int 72 80 7 34.4 -37.6
2 lnt 36 37 7 37.8 -41.0
3 Int-- -- 52 ----- 49-- --- ---7---- --------- 36.4 -39.6
--- ... --- — ---------------------------------- ------------- ——-.....-- ---- _..---- --- - - ---------— ---------
4 Int 52 49 7 36.4 -39.6
5 Int 52 49 7 36.4 -39.6
6 - Int-- -- 52 49 - 7 36.4 -39.6
Prepared in accordance ivith:ASCE 7-16.Chapter 30. PVind Loads-Components and Cladding. %rh Edition(2020)Florida Building Cocle.
Page 1 of 1
® ® e DOOR, OPENING INFORMATION;
P
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET z
Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,.but not less than 4%of least horizontal dimension or 3 ft. ^' CD
PRODUCT APPROVAL REQUIRED OPENING MAXIMU LT[ELE
OPENING (Location) IS THIS A PRODUCT ROUGH ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M �NDQW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING NUTTERS
TYPE TESTED LLION
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS cE W REQ Y/N
SIZE REC�Y/N1NA
1 Int Door I." Lami FL30505.2 50 50 34.4 -37.6 99 x 96 72x80 No No
2 Int Window I"Lami FL15757.1 70 70 37.8 -41.0 37 x 76 36x37 No No
3 Int Window I"Lank FL1.6477.1 55 55 36.4 -39.6 76 x 74 52x49 YES No
4 Int Window I"Lami FL16477.1. 55 55 36.4 -39.6 76 x 74 52x49 YES No
5 Int Window I" Lami FL16477.1 55 55 36.4 -39.6 76 x 74 52x49 YES No
6 Int Window I" Lami FL16477.1 55 55 36.4 -39.6 76 x 74 52x49 YES No