Property Information Building Information j
Owner: JOSHUA&JESSICA MASI Wind Zone: 170 MPH.
Address: 1708 YORK CT Exposure Category: C
FORT PIERCE,FL 34982 Minimum Building Dimension: 34 ft.
Mean Roof Height: 12 ft.
i
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Ma.x Negative
Number Zane Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
I End 47 49 7 36.6 -48.3
2 End 47 49 7 36.6 -48.3
r 3 End 43 65 7 36.2 -47.3
4 End 43 65 7 36.2 -47.3
5 End 43 58 7 36.4 -47.9
b End 43 58 7 36.4 -47.9
7 Int 36 33 7 37.8 -41.0
8 Int 36 33 7 37.8 -41.0
9 Int 36 33 7 37.8 -41.0
- ----- - --- -- - - -- ---------- - ------ ----�
10 Int 36 33 7 37.8 -41.0
11 End 22 33 7 37.8 -50.6
12 End 31 33 7 37.8 -50.6
13 ---- lilt ----- -31 -J 33 - 7 -, 37.8 -_ -41.0
14 blt 47 49 7 36.6 -39.8
--- 15
bit --------- 3 1- --- 18 ----- -7- ----37.8 --- -- _41.0
16 Int 47 33 7 37.6 -40.8
17 Int 62 33 7 36.9 -40.1 j
18 Int 62 33 7 36.9 -40.1
19 Int 47 34 7 37.5 -40.7
20 --Iut---- --- 47 -------- 34 ------ 7 --- 37.5 -40.7
Prepared in accordance wills ASCE;-16.Chapter 30. mind Goads-Components and Cladding. %rh Edition(2020)Florida Building Code.
Page I of 1
WINDOW & DOOR OPENING: INFORMATION
RECEIVED 1 OPY
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Nov i 2 ���tt3 ft Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimensidn .
PRODUCT APPROVAL REQUIRED OPENING MAXI Q1efH MULTIPLE
OPENING (Location) IS THIS A PRODUCT rmi
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW ARE
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
SIZE REQ Y/N/NA
NUMBER or Interior OR DOOR TYPE NUMBER (+)PSF (-)PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLION REQ Y/N
1 End Window 7/8"Lami 20-1103.06 55 55 36.6 -48.3 60 x 60 47x49 No No
2 End Window 7/8"Lami 20-1103.06 55 55 36.6 -48.3 60 x 60 47x49 No No
3 End Window 15116"Lami FL11409.2 55 55 36.2 -47.3 72 x 72 43x65 No No
4 End Window 15116"Lami FL11409.2 55 55 36.2 -47.3 72 x 72 43x65 No No
5 End Window 7/8"Lami 20-1103.06 55 55 36.4 -47.9 60 x 60 43x58 No No
6 End Window 7/8"Lami 20-1103.06 55 55 36.4 -47.9 60 x 60 43x58 No No
7 Int Window 7/8"Lami 20-1103.07 55 55 37.8 -41.0 36 x 68 36x33 No No
8 Int Window 7/8"Lami 20-1103.07 55 55 37.8 -41.0 36 x 68 3603 No No
9 Int Window 7/8"Lami 20-1103.07 55 55 37.8 -41.0 36 x 68 36x33 No No
10 Int Window 7/8"Lami 20-1103.07 55 55 37.8 -41.0 36 x 68 3603 No No
11 End Window 7/8"Lami 20-1103.06 55 55 37.8 -50.6 60 x 60 22x33 No No
12 End Window 7/8"Lami 20-1103.06 55 55 37.8 -50.6 60 x 60 31x33 No No
13 Int Window 7/8"Lami 20-1103.08 55 55 37.8 -41.0 53 x 77 31x33 No No
14 Int Window 7/8"Lami 20-1103.09 55 55 36.6 -39.8 74 x 63 47x49 No No
15 Int Window 7/8"Lami 20-1103.05 55 55 37.8 -41.0 36 x 36 31x18 No No
16 Int Window 7/8"Lami 20-1103.09 55 55 37.6 -40.8 74 x 63 47x33 No No
17 Int Window 7/8"Lami 20-1103.09 55 55 36.9 -40.1 74 x 63 6203 No No
18 Int Window 7/8"Lami 20-1103.09 55 55 36.9 -40.1 74 x 63 62x33 No No
19 Int Window 7/8"Lami 20-1103.09 55 55 37.5 -40.7 74 x 63 47x34 No No
20 Int Window 7/8"Lami 20-1103.09 55 55 37.5 -40.7 74 x 63 4704 No No