Loading...
HomeMy WebLinkAboutEngineering JLI Ile COPY RECEIVED STM R- - __ 500.SW 12thAve - IGHT Dberfleld Beach,FL 33442 NOV 2021 W 1 N D W S Ph:561-922-,6747 St.t UCI�GdutltY Fax.56,1-292-3562 tIlm Property Information Building Information j Owner: JOSHUA&JESSICA MASI Wind Zone: 170 MPH. Address: 1708 YORK CT Exposure Category: C FORT PIERCE,FL 34982 Minimum Building Dimension: 34 ft. Mean Roof Height: 12 ft. i Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Ma.x Negative Number Zane Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) I End 47 49 7 36.6 -48.3 2 End 47 49 7 36.6 -48.3 r 3 End 43 65 7 36.2 -47.3 4 End 43 65 7 36.2 -47.3 5 End 43 58 7 36.4 -47.9 b End 43 58 7 36.4 -47.9 7 Int 36 33 7 37.8 -41.0 8 Int 36 33 7 37.8 -41.0 9 Int 36 33 7 37.8 -41.0 - ----- - --- -- - - -- ---------- - ------ ----� 10 Int 36 33 7 37.8 -41.0 11 End 22 33 7 37.8 -50.6 12 End 31 33 7 37.8 -50.6 13 ---- lilt ----- -31 -J 33 - 7 -, 37.8 -_ -41.0 14 blt 47 49 7 36.6 -39.8 --- 15 bit --------- 3 1- --- 18 ----- -7- ----37.8 --- -- _41.0 16 Int 47 33 7 37.6 -40.8 17 Int 62 33 7 36.9 -40.1 j 18 Int 62 33 7 36.9 -40.1 19 Int 47 34 7 37.5 -40.7 20 --Iut---- --- 47 -------- 34 ------ 7 --- 37.5 -40.7 Prepared in accordance wills ASCE;-16.Chapter 30. mind Goads-Components and Cladding. %rh Edition(2020)Florida Building Code. Page I of 1 WINDOW & DOOR OPENING: INFORMATION RECEIVED 1 OPY A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Nov i 2 ���tt3 ft Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimensidn . PRODUCT APPROVAL REQUIRED OPENING MAXI Q1efH MULTIPLE OPENING (Location) IS THIS A PRODUCT rmi GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW ARE LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS SIZE REQ Y/N/NA NUMBER or Interior OR DOOR TYPE NUMBER (+)PSF (-)PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLION REQ Y/N 1 End Window 7/8"Lami 20-1103.06 55 55 36.6 -48.3 60 x 60 47x49 No No 2 End Window 7/8"Lami 20-1103.06 55 55 36.6 -48.3 60 x 60 47x49 No No 3 End Window 15116"Lami FL11409.2 55 55 36.2 -47.3 72 x 72 43x65 No No 4 End Window 15116"Lami FL11409.2 55 55 36.2 -47.3 72 x 72 43x65 No No 5 End Window 7/8"Lami 20-1103.06 55 55 36.4 -47.9 60 x 60 43x58 No No 6 End Window 7/8"Lami 20-1103.06 55 55 36.4 -47.9 60 x 60 43x58 No No 7 Int Window 7/8"Lami 20-1103.07 55 55 37.8 -41.0 36 x 68 36x33 No No 8 Int Window 7/8"Lami 20-1103.07 55 55 37.8 -41.0 36 x 68 3603 No No 9 Int Window 7/8"Lami 20-1103.07 55 55 37.8 -41.0 36 x 68 36x33 No No 10 Int Window 7/8"Lami 20-1103.07 55 55 37.8 -41.0 36 x 68 3603 No No 11 End Window 7/8"Lami 20-1103.06 55 55 37.8 -50.6 60 x 60 22x33 No No 12 End Window 7/8"Lami 20-1103.06 55 55 37.8 -50.6 60 x 60 31x33 No No 13 Int Window 7/8"Lami 20-1103.08 55 55 37.8 -41.0 53 x 77 31x33 No No 14 Int Window 7/8"Lami 20-1103.09 55 55 36.6 -39.8 74 x 63 47x49 No No 15 Int Window 7/8"Lami 20-1103.05 55 55 37.8 -41.0 36 x 36 31x18 No No 16 Int Window 7/8"Lami 20-1103.09 55 55 37.6 -40.8 74 x 63 47x33 No No 17 Int Window 7/8"Lami 20-1103.09 55 55 36.9 -40.1 74 x 63 6203 No No 18 Int Window 7/8"Lami 20-1103.09 55 55 36.9 -40.1 74 x 63 62x33 No No 19 Int Window 7/8"Lami 20-1103.09 55 55 37.5 -40.7 74 x 63 47x34 No No 20 Int Window 7/8"Lami 20-1103.09 55 55 37.5 -40.7 74 x 63 4704 No No