Loading...
HomeMy WebLinkAboutAPPROVED DRAWING Zayne (2) M.A. CORSON & ASSOCIATES, Inc. ARCHITECTURE * STRUCTURAL DESIGN 412 Colorado Ave., Stuart, Fl. 34994 (772) 223-8227 * Lic. #AR91665 To: St. Lucie County - Building & Code Regulation Division Date: November 12, 2021 Re: Mathew & Pamela Zane 9900 S. Ocean Drive / Oceana N. II /Middle Unit 1204 Jensen Beach, Fl. , 34957 It is acceptable to replace existing window,entry door, sliding glass door, and mullion bars for the address listed above with the units as follows: 1) S.H. - The PGT systems Series "SH 5500A" L.M.I. the pvc single hung window has a Florida number NOA-#20-0401.03. It has a +65 /-70 design pressure and has a L.M.I. & S.M.I. "D" approval and HVHZ. 2) FIBERGL. DR. - The Jeld-Wen Design Pro / Smooth Pro impact glazed fiberglass door has a FL #16708.1 R13. It has a +65 /-65 design pressure and has a small missile "D" approval and HVHZ . 3) S.G.D. - The International Impact Building Products Series " Titan 90 " aluminum sliding glass door with reinforcements has a Miami Dade NOA # 20-1202.12. It has a +90 / -90 design pressure. It has a small and large missile "D" approval HVHZ. 4) MULL. BARS - The Series "PGT" Clipped Extruded Aluminum Tube Mullion - L.M.I has a Miami Dade NOA # 20-0406.03. It has a +170.0 /-170.0 design pressure and has a large missile "D" approval and HVHZ . The worst case scenario building design pressures of addr ess listed above in Zone 4 is +58.7 / - 63.7 and Zone 5 is +58.7 / -78.5. The building has a type II classification and exposure category "D" for the 7th Edition of the FBC (2020). SCOPE OF WORK: New window, entry door, sliding glass door, and mullion bars. DESIGN PARAMETERS AND ASSUMPTIONS USED: 1.DESIGN CODE: Florida Building Code Seventh Edition (2020) 2. Structure Designed: Enclosed 3. Risk Category: II Exposure Category: D 4. Design Wind Velocity 170 mph Nominal Wind Speed 132 mph End Zone Width: 4 ft 5. Mean Roof Height 153 ft Roof Pitch: 0:12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: Zone 4: +58.7 / -63.7 P.S.F. & Zone 5: +58.7 / -78.5 P.S.F. Worst case scenario has been calculated. 7. Design Loads: Floor: N/A Roof/Dead: N/A Roof/Live: N/A Balcony: N/A Dock: N/A Deck: N/A Stairs: N/A Fence: N/A Railings: N/A 8. Were Shear Walls Considered For Structure? N/A Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? N/A 10. Design Soil Bearing Pressure: N/A Soil Test Reports Submitted? N/A Thank you for your time and consideration. If you have any questions please call. Respectfully, Mark A Corson Mark A. Corson A.I.A., NCARB President Mark A Corson Digitally signed by Mark A Corson Date: 2021.11.12 10:56:02 -05'00'