Loading...
HomeMy WebLinkAboutNEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM19.72 KWSYSTEM SIZE :23.12 KW DC STCVICINITY MAPSITE MAP (N.T.S)A-01SITE MAP &VICINITY MAPGARY & CHERI RHODESNEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEMDC SYSTEM SIZE (23.12 KW)33°C0°C0 PSF160MPH (ASCE 7-16)IC82.28 A(68) ENPHASE IQ7PLUS-72-2-USMICROINVERTERSLINE SIDE TAP IN THE MSP-1WIND FLOW MAP(4) BRANCHES OF 11 MODULES(2) BRANCHES OF 12 MODULESSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809DC RATING OF SYSTEMAC RATING OF SYSTEMAC OUTPUT CURRENTNO. OF MODULESNO. OF INVERTERSPOINTS OF CONNECTIONARRAY STRINGINGDESCRIPTIONNEW GRID-INTERACTIVE PHOTOVOLTAICSYSTEM WITH NO BATTERY STORAGESYSTEM DETAILSGOVERNING CODESFLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)NATIONAL ELECTRIC CODE, NEC 2017 CODE BOOK, NFPA 70SITE MAP & VICINITY MAPA - 01A - 02S - 01SINGLE LINE DIAGRAMWIRING CALCULATIONSSYSTEM LABELINGMODULE DATASHEETE - 02E - 03E - 04STRUCTURAL ATTACHMENT DETAILSINVERTER DATASHEETCOMBINER BOX DATASHEETATTACHMENT DATASHEETDS - 01DS - 02DS - 03DS - 04S - 02SHEET INDEXSHEET NO.SHEET NAMEROOF PLAN & MODULESARRAY LAYOUTSITE DETAILSASHRAE EXTREME LOWASHRAE 2% HIGHGROUND SNOW LOADWIND SPEEDRISK CATEGORYWIND EXPOSURE CATEGORY(68) HANWHA Q.PEAK DUO BLK-G8 340WMODULESRACKING DATASHEETDS - 05THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MINDY NICOLE O'NEAL, PE ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.LAYOUT SUBJECT TO CHANGEBASED ON SIDE CONDITIONS40.55"68.50"REPORTDS - 06STRUCTURAL ANALYSIS REPORT 1DS - 07DS - 08STRUCTURAL ANALYSIS REPORT 2COOLIDGE RDUMMSPUMMSPCP2CP 1ACD 1ACD 4TRENCHING 250'TRENCHING 50'(E) MAIN SERVICE PANEL 1(INSIDE HOUSE)(E) UTILITY METER 1(OUTSIDE HOUSE)(E) MAIN SERVICE PANEL 2(INSIDE BARN)(E) UTILITY METER 2(OUTSIDE BARN)DRIVEWAYPV ARRAY359'-6"106'-4"676'-10"394'-3"540'-2"JB 2JB 1ACD 2ACD 3SINGLE LINE DIAGRAME - 01 LINE SIDE TAP IN THE MSP-2 A-02 & MODULESROOF PLANMODULE TYPE, DIMENSIONS & WEIGHTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809LEGENDSUMACDPMMSP- UTILITY METERJB- AC DISCONNECT- PRODUCTION METER-MAIN SERVICE PANEL- VENT, ATTIC FAN(ROOF OBSTRUCTION)- JUNCTION BOXCP- COMBINER PANEL- CONDUIT- MICROINVERTER- FIRE SETBACKNUMBER OF MODULES = 68 MODULESMODULE TYPE = HANWHA Q.PEAK DUO BLK-G8 340W MODULESWEIGHT = 43.87 LBS / 19.9 KG.MODULE DIMENSIONS = 68.50" X 40.55" = 19.29 SFNUMBER OF INVERTER = 68 MICROINVERTERSINVERTER TYPE = ENPHASE IQ7PLUS-72-2-US MICROINVERTERSDC SYSTEM SIZE: 23.12 KWAC SYSTEM SIZE: 19.72 KWM- METER MAIN COMBO(N) AC DISCONNECT 2UMMSPUMMSPCP2CP 1ACD 1ACD 4TRENCHING 250'(E) MAIN SERVICE PANEL 1(INSIDE HOUSE)(E) UTILITY METER 1(OUTSIDE HOUSE)(E) MAIN SERVICE PANEL 2(INSIDE BARN)(E) UTILITY METER 2(OUTSIDE BARN)PV ARRAY(N) AC DISCONNECT 4JB 2JB 1ACD 3ACD 2(N) AC DISCONNECT 1(N) AC DISCONNECT 3(N) COMBINER PANEL 2(N) COMBINER PANEL 1TRENCHING 50'(N) JUNCTION BOX 2(N) JUNCTION BOX 1GENERAL INSTALLATION PLAN NOTES:1)GROUND ATTACHMENTS SHALL BE INSTALLED PER MANUFACTURER'S INSTALLATION MANUAL. REFER TOSHEET S-01 FOR APPROXIMATE ARRAY LAYOUT.2)GROUND MOUNT SYSTEM IS A NEW STAND ALONE STRUCTURE. CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANS AND IN FIELD CONDITIONS.TEST REPORT DATA PROVIDED BY SML PROVIDED TO CERTIFY STRUCTURAL INTEGRITY OF MODULE SUPPORTS IN COMPLIANCE WITH IBC: BUILDING CHAPTER 16. STRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFT WIND LOADS, AND EQUIPMENT DEAD LOADS. REFER TO STRUCTURAL ANALYSIS DATA SHEETS IN APPENDIX FOR MORE INFORMATION. S-01ARRAYLAYOUTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809(GROUND MOUNT)MODULES - 68ARRAY TILT - 15°ARRAY AZIMUTH - 180°LEGENDS- IRONRIDGE TOP CAPS- PIPE- RAIL CONNECTOR- RAILCANTILEVERE-W PIER SPACINGN-S PIER SPACINGCROSS PIPE9'-10"1'-3"7'-6"51'-8"CANTILEVERE-W PIER SPACINGN-S PIER SPACINGCROSS PIPE9'-10"1'-3"7'-6"51'-8"14'RAIL CONNECTORIRONRIDGE XR1000 RAILSHANWHA Q.PEAK DUO BLK-G8340W PV SOLAR MODULESNEW GROUNDMOUNT SYSTEMGROUND MOUNTIRONRIDGE TOP CAP9'-10"9'-10"9'-10" S-02STRUCTURAL ATTACHMENTDETAILSSTRUCTURAL ATTACHMENT DETAILSSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809CLEARANCENORTH15°LENGTHSCREWN-S PIER SPACINGRAIL14'IRONRIDGE XR1000 RAILSIRONRIDGE UNIVERSALFASTENING OBJECTIRONRIDGE STOPPER SLEEVEPV MODULE1'-10" 2'-4" 3'-11"7'-6"1'-10" 4'-4" 5'-6" 5'-3" 5'FINALGRADE3" CROSS PIPE3" PIER PIPE NOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017, NFPA 70 AND THOSE SET FORTH BYTHE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDINGMAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OFMODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURERAND MODEL NUMBER, INVERTER MANUFACTURER AND MODELNUMBER, AS APPLICABLE.2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTERSPACE IS INADEQUATE.E-01SINGLELINE DIAGRAMSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809SOLAR ARRAY (11.56KW-DC STC)(34) HANWHA Q.PEAK DUO BLK-G8 340W MODULES(2) BRANCHES OF 11 MODULES(1) BRANCH OF 12 MODULESINVERTER SPECIFICATIONSMANUFACTURERENPHASEMODEL NO.IQ7PLUS-72-2-USMAX DC INPUT VOLTAGE60 VMAX OUTPUT POWER290 VANOMINAL AC OUTPUT VOLTAGE 240 VNOMINAL AC OUTPUT CURRENT1.21 AMODULE SPECIFICATIONMODEL NO.HANWHA Q PEAK DUO BLK-G8 340PEAK POWER340WRATED VOLTAGE (Vmpp)34.34 VRATED CURRENT (Impp)9.90 AOPEN CIRCUIT VOLTAGE (Voc)40.70 VSHORT CIRCUIT CURRENT (Isc)10.40 APER FL. STATUE 377.705 (REVISED 7/1/2017) I, MINDY NICOLE O'NEAL PE#69779, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE.G(N)JUNCTIONBOX-11 STRING OF11 MODULES WITH MICROINVERTERS1 STRING OF11 MODULES WITHMICROINVERTERS1 STRING OF12 MODULES WITHMICROINVERTERS20A/2PG20A/2PENVOY IQ15A/2P(N)IQ ACCOMBINER PANEL-1(3) #10 AWG THWN-2 - L1(3) #10 AWG THWN-2 - L2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(E)200APANEL-1 120/240V(N)60A ACDISCONNECT-2FUSEDUM1GNG60A/2P200A(E)MAIN SERVICE(3) #3 AWG THWN-2(1) #6 AWG THWN-2 GND IN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC, LFNC, FMT, ENT OR EMT CONDUIT RUNLINE SIDE TAP20A/2PTRENCHING 250'FUSED(N)60A ACDISCONNECT-1G60A/2PENPHASE Q CABLES(1) #6 AWG BARE COPPER GND(3) #6 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC, LFNC, FMT, ENT OR EMT CONDUIT RUNGROUND MOUNTED PV SYSTEM TO SERVE HOUSE(3) #3 AWG THWN-2 IN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC, LFNC, FMT, ENT OR EMT CONDUIT RUN NOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017, NFPA 70 AND THOSE SET FORTH BYTHE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDINGMAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OFMODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURERAND MODEL NUMBER, INVERTER MANUFACTURER AND MODELNUMBER, AS APPLICABLE.2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTERSPACE IS INADEQUATE.E-02SINGLELINE DIAGRAMSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809SOLAR ARRAY (11.56KW-DC STC)(34) HANWHA Q.PEAK DUO BLK-G8 340W MODULES(2) BRANCHES OF 11 MODULES(1) BRANCH OF 12 MODULESINVERTER SPECIFICATIONSMANUFACTURERENPHASEMODEL NO.IQ7PLUS-72-2-USMAX DC INPUT VOLTAGE60 VMAX OUTPUT POWER290 VANOMINAL AC OUTPUT VOLTAGE 240 VNOMINAL AC OUTPUT CURRENT1.21 AMODULE SPECIFICATIONMODEL NO.HANWHA Q PEAK DUO BLK-G8 340PEAK POWER340WRATED VOLTAGE (Vmpp)34.34 VRATED CURRENT (Impp)9.90 AOPEN CIRCUIT VOLTAGE (Voc)40.70 VSHORT CIRCUIT CURRENT (Isc)10.40 APER FL. STATUE 377.705 (REVISED 7/1/2017) I, MINDY NICOLE O'NEAL PE#69779, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE.G(N)JUNCTIONBOX-21 STRING OF11 MODULES WITH MICROINVERTERS1 STRING OF11 MODULES WITHMICROINVERTERS1 STRING OF12 MODULES WITHMICROINVERTERS20A/2P20A/2PG20A/2PENVOY IQ15A/2P(N)IQ ACCOMBINER PANEL-2(3) #10 AWG THWN-2 - L1(3) #10 AWG THWN-2 - L2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(E)200APANEL-2 120/240V(N)60A ACDISCONNECT-4FUSEDUM-2GNG60A/2P200A(E)MAIN SERVICE(3) #6 AWG THWN-2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNLINE SIDE TAPTRENCHING 50'(N)60A ACDISCONNECT-3FUSEDG60A/2PENPHASE Q CABLES(1) #6 AWG BARE COPPER GND(3) #6 AWG THWN-2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNGROUND MOUNTED PV SYSTEM TO SERVE BARN(3) #6 AWG THWN-2 IN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC, LFNC, FMT, ENT OR EMT CONDUIT RUN ELECTRICAL NOTES1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION.2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR75 DEGREE C.3. CONDUCTOR TERMINATION AND SPLICING AS PER NEC 110.144. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPSSHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE ASPOSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.5.WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLECODES AND STANDARDS.7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITSARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELEDAND READILY VISIBLE.9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE310.10 (D).16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLEFOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).E-02WIRINGCALCULATIONSSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809ELECTRICAL CALCULATIONS:1. CURRENT CARRYING CONDUCTOR(A)BEFORE IQ COMBINER PANELAMBIENT TEMPERATURE = 33°CCONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF .....NEC 310.15(B)(3)(c)TEMPERATURE DERATE FACTOR - 0.96 ...NEC 310.15(B)(2)(a)GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a)CONDUCTOR AMPACITY= (INV O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B)= [(12 x 1.21) x 1.25] / 0.96 / 0.8= 23.63 ASELECTED CONDUCTOR - #10THWN-2 ...NEC 310.15(B)(16)(B) AFTER IQ COMBINER PANEL (1)TEMPERATURE DERATE FACTOR - 0.96GROUPING FACTOR - 1 CONDUCTOR AMPACITY=(TOTAL INV O/P CURRENT) x 1.25 / 0.96 / 1 ...NEC 690.8(B)=[(34x 1.21) x 1.25] /0.96 / 1=53.56 ASELECTED CONDUCTOR - #3 THWN-2 ...NEC 310.15(B)(16)(C) AFTER IQ COMBINER PANEL (2)TEMPERATURE DERATE FACTOR - 0.96GROUPING FACTOR - 1 CONDUCTOR AMPACITY=(TOTAL INV O/P CURRENT) x 1.25 / 0.96 / 1 ...NEC 690.8(B)=[(34x 1.21) x 1.25] /0.96 / 1=53.56 ASELECTED CONDUCTOR - #6 THWN-2 ...NEC 310.15(B)(16)2. PV OVER CURRENT PROTECTION ..NEC 690.9(B)=TOTAL INVERTER O/P CURRENT x 1.25=(34 x 1.21) x 1.25 = 51.425ASELECTED OCPD = 60APV SYSTEM -1 SELECTED EQUIPMENT GROUND CONDUCTOR (EGC) = #6 THWN-2 ... NEC 250.166PV SYSTEM -2SELECTED EQUIPMENT GROUND CONDUCTOR (EGC) = #10 THWN-2 ... NEC 250.122(A)MAX VOLTAGE DROP CALCULATIONCABLE SIZECABLE DESCRIPTIONONE WAYDISTANCE INFEET (D)BRANCHCURRENT (I)RESISTANCE OFCONDUCTOR(R)VOLTAGE (V)% VOLTAGEDROP=(0.2*D*I*R)/V#3 THWN-2AC DISCONNECT 1 TOAC DISCONNECT 225041.140.2452402.10#6 THWN-2AC DISCONNECT 3 TOAC DISCONNECT 45041.140.512400.874 WARNINGELECTRIC SHOCK HAZARD!DO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNINGINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICEPHOTOVOLTAIC SYSTEMEQUIPPED WITH RAPIDE-03WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNING PHOTOVOLTAICPOWER SOURCE!727-571-4141EMERGENCY CONTACTWARNING!INVERTER OUTPUT CONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICEWARNING!DEDICATED SOLAR PANELS DONOT CONNECT ANY OTHER LOADSSHUTDOWNSOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWNSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809SYSTEMLABELINGLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION, COMBINER PANEL(PER CODE: NEC 690.13(B))LABEL LOCATION:CONDUIT RUNWAY(PER CODE: NEC690.31(G)(3)(4))LABEL LOCATION:MAIN SERVICE DISCONNECT(NEC 705.12(B)(3-4) & NEC 690.59)ADHESIVE FASTENED SIGNS:·ANSI Z535.4-2011 PRODUCT SAFETY SIGNS AND LABELS, PROVIDESGUIDELINES FOR SUITABLE FONT SIZES, WORDS, COLORS, SYMBOLS, ANDLOCATION REQUIREMENTS FOR LABELS. NEC 110.21(B)(1)·THE LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THEENVIRONMENT INVOLVED. NEC 110.21(B)(3)·ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLYADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT. IFC 605.11.1.3LABEL LOCATION:COMBINER PANEL, AC DISCONNECT(PER CODE: NEC 690.52)LABEL LOCATION:POINT OF INTERCONNECTION, MAIN SERVICE DISCONNECT(PER CODE: NEC 705.12 (B)(2)(c))[Not required if panelboard is rated not less than sum of ampere ratingsof all overcurrent devices supplying it]DATA PER PANELLABEL LOCATION:AC DISCONNECT, DC DISCONNECT, POINT OFINTERCONNECTION(PER CODE: NEC 690.56(C)(3))IFC 605.11.3.1(1) & 690.56(C)(1)(a) Label for PV Systems thatShut down the array and the conductors leaving the arrayNOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATINGFOR AC MODULE PROTECTION PER CIRCUIT-2402901.2120VVA 60 HzAAPHOTOVOLTAIC SYSTEM AC DISCONNECT-2RATED AC OPERATING CURRENT 41.14 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTSLABEL LOCATION:AC DISCONNECT, INVERTER(PER CODE: NEC 690.54)PHOTOVOLTAIC SYSTEM AC DISCONNECT-1 RATED AC OPERATING CURRENT 41.14 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTSLABEL LOCATION:AC DISCONNECT, INVERTER(PER CODE: NEC 690.54) DS-01DATASHEETMODULESHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 DS-02DATASHEETINVERTERSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 DS-03DATASHEETCOMBINER BOXSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 DS-04DATASHEETATTACHMENTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 DS-05DATASHEETRACKINGSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 DS-06REPORTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 DS-07STRUCTURAL ANALYSISREPORT (1)SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROAM09/29/2021DESIGNERREVIEWERDATEGARY & CHERI RHODES 2405 COOLIDGE RD, FORT PIERCE, FL 34945, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809STRUCTURAL ANALYSISREPORT (2)DS-08