Loading...
HomeMy WebLinkAboutAPPROVED Site plan© 2021 Microsoft Corporation © 2021 Maxar ©CNES (2021) Distribution Airbus DS 8846© 2021 Microsoft Corporation © 2021 Maxar ©CNES (2021) Distribution Airbus DS 21-315CONCEPTUAL SITE PLAN REVISION COMMENTSDATE10250 VILLAGE PARKWAYUNIT 201PORT ST. LUCIE, FL 34987' 772-462-24558 www.edc-inc.comF.B.P.E. CERTIFICATE OF AUTHORIZATION 9935L.B. CERTIFICATE OF AUTHORIZATION 8098ENGINEERS SURVEYORSENVIRONMENTAL10250 VILLAGE PARKWAYUNIT 201PORT ST. LUCIE, FL 34987' 772-462-2455KENWORTH - ENVIRONMENT DRIVE ST. LUCIE COUNTY FLORIDAOF 1Z:\EDC-2021\21-315 - Kenworth - CD Hair Architect\ENGINEERING\AutoCAD\DWGs\21-315 Conceptual Plan R2.dwg, 9/1/2021 8:49 AMCOPYRIGHT: 2020 BY EDC-INC: THIS FIRM EXPRESSLY RESERVES THEIR EXCLUSIVE COMMON LAW COPYRIGHT AND INTELLECTUAL PROPERTY RIGHTS TO THESE DRAWINGS WHICH MAY NOT BE DISPERSED, REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER, NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT THE WRITTEN CONSENT OF THIS FIRM.THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY EDC, INC. SHALL BE WITHOUT LIABILITY TO EDC, INC.1SF AT 21-315 Conceptual Plan R2.dwg JW August 30, 2021 CHECKED BY DRAWN BY FILENAME AS SHOWN DATE FIELD CREW SCALESITE DATAPROPERTY DATALEGAL DESCRIPTION:THE SOUTH 1/2 OF LOT 8 IN THE NORTHWEST 1/4 OF SECTION 6, TOWNSHIP 36 SOUTH, RANGE 40 EAST, MODEL LAND COMPANY, ACCORDING TOTHE PLAT THEREOF RECORDED IN PLAT BOOK 4, PAGE 34, PUBLIC RECORDS OF ST'.LUCIE COUNTY, FLORIDA.CONTAINING 4.61 ACRES, MORE OR LESS.PROPERTY SIZE:4.61 ACFUTURE LAND USE:INDUSTRIAL (IND)ZONING:INDUSTRIAL HEAVY (IH)PARCEL ID3406-501-0040-000-5ADDRESS:5690 ENVIRONMENT DRIVEFORT PIERCE, FL 34981BUILDING DATAGROSS AREA:12,212 SFEXISTING BUILDING A:3,616 SFEXISTING BUILDING B:763 SFEXISTING BUILDING C:406 SFEXISTING BUILDING D:2,427 SFPROPOSED BUILDING E:5,000 SFBUILDING SETBACKSFRONT:50SIDE:30REAR:40BUILDING COVERAGEPROPOSED:12,212 SF6.08%MAXIMUM ALLOWED:100,405 SF50%PARKING DATAREQUIRED PARKING:22 SPACESAUTO SERVICE(943):13OFFICE (712):9PROPOSED PARKING:26 SPACESREQUIRED HANDICAP:2 SPACESPROPOSED HANDICAP:2 SPACESPROJECT NOTESDRAINAGE:THE SITE LIES IN A MASTER DRAINAGE SYSTEM. IT TREATS THE FIRST HALF-INCH OF STORMWATER RUNOFF FROM THE SITE BEFOREDISCHARGING TO THE MASTER SYSTEM (SFWMD PERMIT 56-01444-P)40HANDICAP STALLMITERED END SECTIONLEGENDEXISTING PAVEMENTEXISTING CONCRETELOCATION MAPSCALE: 1:1000FLORIDA TURNPIKEW MIDWAY ROADG L A D E S C U T O F F R O A D S JENKINS RDPARKING STALL COUNTSPACESZ:\EDC-2021\21-315 - Kenworth - CD Hair Architect\ENGINEERING\AutoCAD\DWGs\21-315 Conceptual Plan R2.dwg, 24 x 36, 9/1/2021 8:49:08 AM, victo, EDC, Inc.