HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETST. LUCIE
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: Certainteed
Product Approval No.: FL2533-R2-12
Design Wind Pressures, From RAS 128 or Calculations:
Zone 1':-34.6Zone 1: 60.3Zone 2: Zone 3: 108.4
Max. Design Pressure, from the specific product approval
system: -127.5
Deck:
V►y•0f
Gauge Thickness: 1 /$"
Slope:
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:.
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No_ of Ply(s):_ FjIntIaStIC
Base Sheet Fastener/Bonding Material:
SA
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply: Flintlastic
Top Ply Fastener/Bonding Material:
SA
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':—"
oc @ Lap, # Rows o ' as
Zone 1.—"
oc @ Lap, # Rows ® ' oc
Zone 2:._._."
oc @ Lap, # Rows o woo
Zone 3:—"
oc @ Lap, # Rows_____ 0 700
Number of Fasteners Per Insulation Board:
Zone 1': —Zone 1: Zone 2: Zone 3:
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc..,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
Flintlastic
Flintlastic
FT.
Parapet
Height
FT.
15$
Mean
Roof
Drip Edge: 3" X 3" Galy Alum Height
3T. LUCIE WORKS
Master Permit No.
Section A (General Information)
Process No.
Contractors Name: Total Home Roofing License # CCC1330489
Job Address 6910 Shannon Dr Fort Pierce FL 34951
D Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles
® Asphaltic Shingles ❑Metal Panel/Shingles DWoodShingles/Shakes
D Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
D New roof D Repair ❑ Maintenance OQ Reroofing ORecovering
. ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) 0 Steep Sloped Roof Area (SF) 2532 Total (SF) 2532
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include
dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
11/16/21, 9:01 AM
3222_3316_1.1p9 (512x384)
(4B)
https,J/paslc.gov/lmageSketchestsketch/3/3222_3316_1.jpg 1/1
3T. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: Owens Corning
Notice of Acceptance Number:
FL10674-R16
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1:-747one 2e: -7�one 2n-1one 2r-108one 3e. 108one 3r: 128
�� " /
Roof Slope
\71
Underisyme12 nsuiatiorc N/A
Fire Barrier: N/A
Ridge Yettfladon? Fastener Type & Spacing: t > Ring Shank Nails
n//a
Adhesive Type: N/A
Type Cap Sheet I N/A
Mean Roof Height: 15' RoofCovedng I Asphalt Shingles
Type & Sim Drip 3" X 3" Galy Alum
Edge: