HomeMy WebLinkAboutpilings reportHeadquarters 11345 U.S. Highway 1 Sebastian, FL, 32958 Orlando 723 Progress Way Sanford, FL. 32771 DATE MOLDED: CONTRACTOR: JOB LOCATION it CA1 t ENGINEERING Z% AVL AND TESTING REPORT OF COMPRESSIVE STRENGTH OF CONCRETE SPECIMENTS (ASTM C-31, ASTM C-39, ASTM C-143) 10/14/2021 JWN Construction 1106 Nettles Boulevard Jensen Beach, Florida KSM #: 218416-1c/ah Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A,# 5693 KSMengineering. net PLACEMENT: Auger Cast -In -Place Pilings SET NUMBER: 1 MIX: 5,000 Grout Specimen Number Age Test Date Broken Average Cylinder Diameter (in) CylinderArea (in Compressive Force (LBS) Compressive Strength rent) Fracture Type Capping Method Tested By 1 7 28 10/21/2021 11/11/2021 3.01 3.00 7.11 7.07 26200 47480 3680 6720 4 5 U U DM DS 28 11/11/2021 3.00 7.07 48770 6900 5 U DS 28 11/11/2021 3.00 7.07 49630 7020 3 U DS FIELD MEASUREMENTS WEATHER CONDITIONS: N/A SLUMP (IN). N/A TEMPERATURE (°F): AIR: 80° LOAD VOLUME (YARDS) 9/35 AIR CONTENT: N/A CONCRETE: N/A MIN. / MAX. N/A MIN. / MAX. N/A SAMPLED BY: KSM NV BATCH INFORMATION SUPPLIER: Cemex TIME BATCHED: 8:27 TRUCK No.: 71737 TICKET No.: 38122777 TIMED SAMPLED 9:36 ON -SITE ADMIXTURES: GENERAL REMARKS U: Unbonded Caps (ASTM C1231) S: Sulfer (ASTM C617) (AASHTO T231) UNLESS NOTED ABOVE, MINIMUM AND MAXIMUM TEMPERATURE AND AIR CONTENT WERE NOT TAKE PER ASTM C31 FRACTURE TYPES TYPE: 1 TYPE 2 TYPE 3 TYPE: 4 TYPE 6 T`IfPE 6 Respectfully Submitted: PE # 68366 11/13/2021 Test report shall not be reproduced, except in full, without the written appravaI of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business- WBE heduyualtet5 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 DATE MOLDED CONTRACTOR: JOB LOCATION 1W C Z t ENGINEERING 4 ANZ AND TESTING REPORT OF COMPRESSIVE STRENGTH OF CONCRETE SPECIMENTS (ASTM C-31, ASTM C-39, ASTM C-143) 10/14/2021 JWN Construction 1106 Nettles Boulevard Jensen Beach, Florida KSM #: 218416-1c/ah Ivlalling PO Box 78-1377 Sebastian, FL, 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net PLACEMENT: Auger Cast -In -Place Pilings SET NUMBER: 1 MIX: 5,000 Grout Specimen Average Cylinder Cylinder Area Con Number Age Test Date Broken Diameter (in} (in2) For 1 7 10/21/2021 3.01 7.11 28 11/11/2021 3.00 7.07 28 11/11/2021 3.00 7.07 28 11/11/2021 3.00 7.07 pressive ce LBS ( } 6200 Compressive Strength (PSI) 3680 Fracture Type Capping Method Tested By 4 U DM 7480 6720 5 U DS 8770 6900 5 U DS 9630 7020 3 U DS FIELD MEASUREMENTS WEATHER CONDITIONS: N/A SLUMP (IN): N/A TEMPERATURE (°F): LOAD VOLUME (YARD S3) 9/35 AIR CONTENT: N/A AIR: CONCRETE: 80' N/A MIN. / MAX. N/A MIN. / MAX. N/A SAMPLED BY: KSM NV BATCH INFORMATION SUPPLIER: Cemex TIME BATCHED: 8:27 TRUCK No.: 71737 TICKET No.: 38122777 TIMED SAMPLED 9:36 ON -SITE ADMIXTURES: GENERAL REMARKS U: Unbonded Caps (ASTM C1231) S: Sulfer (ASTM C617) (AASHTO T231) UNLESS NOTED ABOVE, MINIMUM AND MAXIMUM TEMPERATURE AND AIR CONTENT WERE NOT TAKE PER ASTM C31 FRACTURE TYPES Respectfully Submitted: S�"1111 11 ► 1 1"0, K EL IYPI=1 llt'PE 2 TYPE 3 TYPE: 4 TyPE 6 TYPE 6 ,: �`•i y�C�� �` S� ''••,� :,� � 3�6 ro SASE O �0 •' S Presi, ONP�-�,6,`• I�IIa1e1111�� - PE # 68366 11/13/2021 Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business- WBE