HomeMy WebLinkAboutPRODUCT DESCRIPTION -
'File Kpy
�1 56 R
EXTR E ME M ETALcODE COMPLIANCE
FABRICATORS ST. L CIE COUNTY
SKILLED CRAFTERS OF METAL ROOFING SYSTEMS ��'
032 Aluminum ( min ) TOP Azov/er, 15/32" (min )
plywood
Extreme Metal Fabricators
2120 SW Poma Dr I Palm City FL 34990
Product Description
Nailstrip, snaplock style panel with a 16" maximum panel width and a
nominal rib height of 1.5"
Product Material
Nominally 0.032" aluminum or, thicker
Fastener
#10 x 1-inch pancake style fastener
Compliant with FBC 1506.6 where required.
Substrate/Deck
RECEIVED 15/32" (min) plywood or
DEC 07 2021 3/4" (min) thick wood plank (min S.G. of 0.42)
St.Lucie County Evaluated by,
Permitting David E n g, PE
Timberlake Cove, LLC
3324 W Univ Ave #206 1 Gainesville FL
FL PE 81377 1 FL CA 33344
www.TimberLakeCove.com
. ..
,..........
E . . (,
No.81377 =_
David E Eng
2310:26+01'00'- * cc
_ 0 • STATE OF 40
P<•ORIO P•. G\=�
!0NAk 1a�\0��\
This item has been digitally ,
and sealed by D.E.Eng,PE,on the
date indicated. Printed copies of this
AX
document
copiesand sealed and the signature must be
verified on any electronic
i
TOP ENGINEERING LOAD •
I 1
Instructions:
Select the appropriate load table that applies to the OK.-a
structure in question. e.
Determine the design wind speed for the project a' 2 2 3
location. 2,
1 1 2
Use the attachment method Indicated for that \2
2 3
windsP eed within each roof zone. 2 1 �. 2 � a _11
.—�-- 2 2 -- --�3 -a
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. - ---
For the load tables below, the worst case was taken
for each zone and reported using the standard zones j2 '. 2
1-2-3:
a 2
._ 3 L...=._..___...._..__.. HIP ROOF L._......................._... _..... ..........__._._.. ._......_._....�
Zone 1 includes zones 1 and 1 II ... ...._..... .._
I
Zone 2 includes zones 2e, 2r, and 2n a- I GABLE ROOF -Ja�'
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple LESS IN4 EITER4or LE TR'TORONTRD ENSIONOR R09VEN BUT NOT
scheme, at the expense of some design efficiency. OR AS OEIEI NLD BY DESIGN 011 OTHER i1FNLIC"LL CODE.
Contact the manufacturer for further information, ROOF ZONES FOR GENERIC BUILDING
or consult a licensed design professional.
METHOD A
NR: NOT RATED
ho FEMALE LEG SNAPS CONSULT DESIGN
ONTO MALE LEG
SEALANT APPLIED TO PROFESSIONAL AS
BASE OF MALE LEG NECESSARY
3910 FASTENER
AT 6"O.C.
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposur'e area
Have either a flat roof,or gablelhip roof with max slope of 12:12 Have either a flat roof,or gablelh'ip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL25621.10: 032 To Max on 15/32" plywood FL25621.10: 032 To Max on 15132" Plywood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130!140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A
Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A A A
Zone 3: A A A A A A A A A A A Zone 3: A A A A A A A A
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof less than 70,hip roof with Have either a flat roof less than 7°,hip roof with
max slope of 12:12,or gable roof with slope between 4.4:12&12:12 max slope of 12:12,or gable roof with slope between 4.4:12&12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL25621.10: 032 To Max on 15/32" Plywood FL25621.10: 032 To' Max on 15/32" Plywood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 1301140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A . A A A A A A A
Zone 2: A A A A A A A A A A A Zone 2: A A A A ' A A A A A A A
Zone 3: A A A A A A A A A A A Zone 3: A 'A A A ; A A A A A