Loading...
HomeMy WebLinkAboutWind Load Calculation - File COPY 9 500 SW 12th Ave Deeifleld'Beach,FL 33442 W' SW I �,` Ph.561`922-6747 Fax.561-292-3562 Property Information Building Ilfonnation Owner: MICHAEL PATTERSON&DAWNA HARRIS Wind Zone: 170 MPH. Address: 216 RIOMAR DR Exposure Category: { C PORT ST LUCIE.FL 34952 Minimum Building Dimension: 42 ft. Mean Roof Height: 12 ft. Risk Category: I1 I Design Pressure Calculations Opening Location Device Device Device Max Positive I Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressilire(psf) Pressure(pst) 1 Int 73 49 7 35.6 18.8 --- .--- - _" .. I ----- ------ --- 2 Int 73 49 7 35.6 38 8 --------------- --------------- 3 Int 36 49 7 37.3 -40.5 ---- --- ——--- -- -- --- --- --- ---- ----....------------ ---------- - _---- - - --- ------ - -------- 4 Int 36 24 7 37.8 -41.0 5 Int 73 - --- 37 ---- ----- 7 36.3 -39.5 6 Int 36 49 7 37.3 -40.5 7 Int 36 37 7 37.8 -41.0 8 Int 73 62 7 35.0 -38.2 9 Int 36 37 7 37.8 -41.0 10 End 73 49 7 35.6 -46.1 11 End 73 49 7 3 ------ --- - --- 5.6 -46.1 -- 12 End 73 49 7 35.6 -46.1 13 Int 110 49 7 34.6 -37.8 {i I I RECEIVED DEC 0 12-0 1 ST. Lucie County, Permitting 1 1 Prepared in accordance with:ASCE 7-16.Chapter 30. Wind Loads-Components and Cladding. %th Edition(20 q)Florida Building Code. Page 1 of 1 I i 5 : Illt • ® � • ® INFORMATION. A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%.of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N SIZE REQ Y/N/NA 1 Int Window 7/8"Lami 20-11.03.09 55 55 35.6 -38.8 74 x 63 73x49 No No window 7/8"LTa 20_1 103.09 55 55 35.6 -38.8 74 x 63 - 73x49 No No *� 3 Int window 7/8"Lami 20-1.103.07 55 55 37.3 -40.5 36 x 68 36x49 No 'No 4 Int Window 7/8"Lami 20-1.103.08 55 55 37.8 -41.0 53 x 77 36x24 No No 5 Int Window 7/8"Lanii 20-1 .103.09 55 55 36.3 -39.5 74 x 63 7307 No No 6 Int Window 7/8"Lami 20-1 1,03.07 55 55 37.3 -40.5 36 x 68 36x49 No No 7 Int window 7/8"Lami 20-1103.08 55 55 37.8 -41.0 53 x 77 3607 No No 8 Int Window 7/8"Lami 20-1103.09 55 55 35.0 -38.2 74 x 63 73x62 No No 9 Int Window 7/8"Lami 20-1103.08 55 55 37.8 -41.0 53 x 77 3607 No No 10 End Window 7/8"Lami 20-1.103.09 55 55 35.6 -46.1 74 x 63 73x49 No No 11 End Window 7/8"Lami 20-1103.09 55 55 35.6 -46.1 74 x 63 73x49 No No 12 End Window 7/8"Lami 20-1103.09 55 55 35.6 -46.1 74 x 63 73x49 No No 1.3 Int window 7/8"Lami 20-1103.04 55 55 34.6 -37.8 111 x 63 11Ox49 No No M M B E�