HomeMy WebLinkAboutWind Load Calculation - File COPY
9
500 SW 12th Ave
Deeifleld'Beach,FL 33442
W' SW I �,` Ph.561`922-6747
Fax.561-292-3562
Property Information Building Ilfonnation
Owner: MICHAEL PATTERSON&DAWNA HARRIS Wind Zone: 170 MPH.
Address: 216 RIOMAR DR Exposure Category: { C
PORT ST LUCIE.FL 34952 Minimum Building Dimension: 42 ft.
Mean Roof Height: 12 ft.
Risk Category: I1
I
Design Pressure Calculations
Opening Location Device Device Device Max Positive I Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressilire(psf) Pressure(pst)
1 Int 73 49 7 35.6 18.8
--- .--- - _" .. I ----- ------ ---
2 Int 73 49 7 35.6 38 8
--------------- ---------------
3 Int 36 49 7 37.3 -40.5
---- --- ——--- -- -- --- --- --- ---- ----....------------ ---------- - _---- - - --- ------ - --------
4 Int 36 24 7 37.8 -41.0
5 Int 73 - --- 37 ---- ----- 7 36.3 -39.5
6 Int 36 49 7 37.3 -40.5
7 Int 36 37 7 37.8 -41.0
8 Int 73 62 7 35.0 -38.2
9 Int 36 37 7 37.8 -41.0
10 End 73 49 7 35.6 -46.1
11 End 73 49 7 3
------ --- - --- 5.6 -46.1 --
12 End 73 49 7 35.6 -46.1
13 Int 110 49 7 34.6 -37.8
{i
I
I
RECEIVED
DEC 0 12-0 1
ST. Lucie County, Permitting
1
1
Prepared in accordance with:ASCE 7-16.Chapter 30. Wind Loads-Components and Cladding. %th Edition(20 q)Florida Building Code.
Page 1 of 1
I
i
5 : Illt • ® � • ® INFORMATION.
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%.of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N
SIZE REQ Y/N/NA
1 Int Window 7/8"Lami 20-11.03.09 55 55 35.6 -38.8 74 x 63 73x49 No No
window 7/8"LTa 20_1 103.09 55 55 35.6 -38.8 74 x 63 - 73x49 No No
*� 3 Int window 7/8"Lami 20-1.103.07 55 55 37.3 -40.5 36 x 68 36x49 No 'No
4 Int Window 7/8"Lami 20-1.103.08 55 55 37.8 -41.0 53 x 77 36x24 No No
5 Int Window 7/8"Lanii 20-1 .103.09 55 55 36.3 -39.5 74 x 63 7307 No No
6 Int Window 7/8"Lami 20-1 1,03.07 55 55 37.3 -40.5 36 x 68 36x49 No No
7 Int window 7/8"Lami 20-1103.08 55 55 37.8 -41.0 53 x 77 3607 No No
8 Int Window 7/8"Lami 20-1103.09 55 55 35.0 -38.2 74 x 63 73x62 No No
9 Int Window 7/8"Lami 20-1103.08 55 55 37.8 -41.0 53 x 77 3607 No No
10 End Window 7/8"Lami 20-1.103.09 55 55 35.6 -46.1 74 x 63 73x49 No No
11 End Window 7/8"Lami 20-1103.09 55 55 35.6 -46.1 74 x 63 73x49 No No
12 End Window 7/8"Lami 20-1103.09 55 55 35.6 -46.1 74 x 63 73x49 No No
1.3 Int window 7/8"Lami 20-1103.04 55 55 34.6 -37.8 111 x 63 11Ox49 No No
M
M
B
E�