Property Information Building Iilforination
Owner: SHIRLEY GOLDBERG Wind Zone: 170 MPH.
Address: 1950 CORTEZ BLVD Exposure Category: C
FORT PIERCE,FL 34982 Minimum Building Dimension: 33 ft.
Mean Roof Height: 12 ft.
Risk Category:, II
d
Design Pressure Calculations
Opening Location Device Device Device Max iPositive �� Max Negative
Number ZILone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 110 49 7 34.6 -37.8
2 Int 52 37 7 37.1 -40.3
3 Int 36 37 7 37.8 -41.0
4 Int 26 37 7 37.8 -41.0
5 Int 36 37 7 37.8 -41.0
6 Int 52 37 7 i 7.1 -40.3
7 Int 36 37 7 37.8 -41.0
8 Int 36 37 7 37.8 -41.0
9 End 52 37 - ------7 37.1 -49?
----------- -- --- - - ------ -- --- - - — ----- -1 ------ - ---
10 Int 73 49 7 35.6 -38.8
a
i
i
I
I
d
Prepared in accordance wilh:ASCE%-16,Chapter 30. Wind Loads-Components and Cladding. %air Edition(2021))Florida Building Code.
Page 1 of 1
RMATION
WINDOW & DOOR OPENING INFO
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height;whichever is smaller,but not less than 4°/.of least horizontal dimension or 3 ft.
PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
OPENING (Location) IS THIS A GLAZING PRODUCT APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR TYPE NUMBER + TESTED DIMENSIONS MULLION REQY/N
{ )PSF (-)PSF (+)PSF (-)PSF SIZE REQ Y/N/NA
1 Int window 7/8"Lami 20-1.103.04 55 55 34.6 -37.8 111 x 63 110x49 No No
2 Int Window 7/8"Lami 20-11.03.09 55 55 37.1. -40.3 74 x 63 52x37 No No
3 Int Window 7/8"Lami 20-1103.07 55 55 37.8 -41..0 36 x 68 3607 No No
4 Int Window 7/8"Lami 20-1103.08 55 55 37.8 -41.0 53 x 77 2607 No No
5 Int Window 7/8"Lami 20-1103.08 55 55 37.8 -41.0 53 x 77 36x37 No No
6 Int Window 7/8"Lami 20-1103.09 55 55 37.1. -40.3 74 x 63 5207 No No
7 Int Window 7/8"Lami 20-1103.07 55 55 37.8 -41.0 36 x 68 3607 No No
8 Int Window 7/8"Lami 20-1103.07 55 55 37.8 -41.0 36 x 68 3607 No No
9 End Window 7/8"Lami 20-1103.09 55 55 37.1 -49.2 74 x 63 5207 No No
10 Int Window 7/8"Lami 20-1.103.09 55 55 35.6 -38.8 74 x 63 73x49 No No