HomeMy WebLinkAboutWind Load Calculation Coo
ST �IGHT
M
= 500 8W 12th Ave
= Deerfield Beach,FL 33442
WrN �,4 Ph.561"922-6747
'0 W; S Fex.5q l-292=3562
Property Infonnation Building Information
Owner: LINDA BOWMAN Wind Zone: 170 MPH.
Address: 5699 TRAVELERS WAY :} Exposure Category: C
FORT PIERCE,FL 34982 Minimum Building Dimension: 36 ft.
( Mean Roof Height: f 12 ft.
Jet Risk Category: II
1
Design Pressure Calculations
Opening Location Device Device li Device Max Positive Max Negative
Number Zone Width(in) Height(in) i Elevation(ft) Pressure(psf) Pressure(psf)
I Int 73 62 7 85.0 -38.2
2 Int 36 37 7 37.8 -41.0
3 Int 52 49 7 36.4 -39.6
-- -- -- ---- ----- ------ ----- — ---------- --- ----;--- - ---------
4 Int 52 49 7 36.4 -39.6
{
RECEIVED
DEC 0 t 2021
ST. Lucie County, Peri-nitting
I
i
Prepared is accordance wil{r:ASCE 7-16.Chapter;p. Wind Loads-Components and Cladding. %th Edition(101f))Florida Building Code.
Page 1 of 1
® ® o ® ® ® ® S
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE
OPENING (Location) IS THIS A PRODUCT ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR TYPE NUMBER (+)PSF (-)PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLION REQ'Y/N
SIZE REQ Y/N/NA
I Int Window 7/3"Lami 20-11.03.09 55 55 35.0 -38.2 74 x 63 73x62 No No
2 1nt Window 7/8"Lami 20-1103.08 55 55 37.8 -41.0 53 x 77 36x37 No No
3 Int Window 7/8"Lami 20-11.03.08 55 55 36.4 -39.6 53 x 77 52x49 No No
4 Int Window 7/8"'.a,,,i 20-1,103.08 55 55 36.4 -39.6 1
53 x 77 52x49 No No
m
fl
E
M
I T) CD .
i � w